Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39056469

RESUMO

Ion mobility (IM) is often combined with LC-MS experiments to provide an additional dimension of separation for complex sample analysis. While highly complex samples are better characterized by the full dimensionality of LC-IM-MS experiments to uncover new information, downstream data analysis workflows are often not equipped to properly mine the additional IM dimension. For many samples the data acquisition benefits of including IM separations are all that is necessary to uncover sample information and the full dimensionality of the data is not required for data analysis. Postacquisition reduction and adaptation of the dimensions of LC-IM-MS and IM-MS experiments into an LC-MS format opens the possibility to use a plethora of existing software tools. In this work, we developed data file conversion tools to reduce the complexity of IM data analysis. Three data file transformations are introduced in the PNNL PreProcessor software: (1) mapping the IM axis to the LC axis for IM-MS data, (2) converting the drift time vs m/z space to CCS/z vs m/z space, and (3) transforming All Ions IM/MS mobility aligned fragmentation data to a standard LC-MS DDA data file format. These new data file conversions are demonstrated with corresponding lipidomics and proteomics workflows that leverage existing LC-MS data analysis software to highlight the benefits of the data transformations.

2.
Nat Commun ; 14(1): 6795, 2023 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-37880209

RESUMO

O-acetylation is a common modification of sialic acids that has been implicated in a multitude of biological and disease processes. A lack of analytical methods that can determine exact structures of sialic acid variants is a hurdle to determine roles of distinct O-acetylated sialosides. Here, we describe a drift tube ion mobility-mass spectrometry approach that can elucidate exact O-acetylation patterns as well as glycosidic linkage types of sialosides isolated from complex biological samples. It is based on the use of a library of synthetic O-acetylated sialosides to establish intrinsic collision cross section (CCS) values of diagnostic fragment ions. The CCS values were used to characterize O-acetylated sialosides from mucins and N-linked glycans from biologicals as well as equine tracheal and nasal tissues. It uncovered contrasting sialic acid linkage types of acetylated and non-acetylated sialic acids and provided a rationale for sialic acid binding preferences of equine H7 influenza A viruses.


Assuntos
Glicosídeos Cardíacos , Ácido N-Acetilneuramínico , Animais , Cavalos , Ácido N-Acetilneuramínico/metabolismo , Glicosídeos , Acetilação , Ácidos Siálicos/metabolismo , Espectrometria de Massas
3.
J Mass Spectrom ; 58(1): e4902, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36694312

RESUMO

High-throughput screening (HTS) is a technique mostly used by pharmaceutical companies to rapidly screen multiple libraries of compounds to find drug hits with biological or pharmaceutical activity. Mass spectrometry (MS) has become a popular option for HTS given that it can simultaneously resolve hundreds to thousands of compounds without additional chemical derivatization. For this application, it is convenient to do direct analysis from well plates. Herein, we present the development of an infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) source coupled directly to an Agilent 6545 for direct analysis from well plates. The source is coupled to a quadrupole time-of-flight (Q-TOF) mass spectrometer to take advantage of the high acquisition rates without sacrificing resolving power as required with Orbitrap or Fourier-transform ion cyclotron resonance (FTICR) instruments. The laser used for this source operates at 100 Hz, firing 1 pulse-per-burst, and delivers around 0.7 mJ per pulse. Continuously firing this laser for an extended duration makes it a quasi-continuous ionization source. Additionally, a metal capillary was constructed to extend the inlet of the mass spectrometer, increase desolvation of electrospray charged droplets, improve ion transmission, and increase sensitivity. Its efficiency was compared with the conventional dielectric glass capillary by measured signal and demonstrated that the metal capillary increased ionization efficiency due to its more uniformly distributed temperature gradient. Finally, we present the functionality of the source by analyzing tune mix directly from well plates. This source is a proof of concept for HTS applications using IR-MALDESI coupled to a different MS platform.

4.
Analyst ; 148(2): 391-401, 2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36537590

RESUMO

Native ion mobility-mass spectrometry (IM-MS) has emerged as an information-rich technique for gas phase protein structure characterization; however, IM resolution is currently insufficient for the detection of subtle structural differences in large biomolecules. This challenge has spurred the development of collision-induced unfolding (CIU) which utilizes incremental gas phase activation to unfold a protein in order to expand the number of measurable descriptors available for native protein ions. Although CIU is now routinely used in native mass spectrometry studies, the interlaboratory reproducibility of CIU has not been established. Here we evaluate the reproducibility of the CIU data produced across three laboratories (University of Michigan, Texas A&M University, and Vanderbilt University). CIU data were collected for a variety of protein ions ranging from 8.6-66 kDa. Within the same laboratory, the CIU fingerprints were found to be repeatable with root mean square deviation (RMSD) values of less than 5%. Collision cross section (CCS) values of the CIU intermediates were consistent across the laboratories, with most features exhibiting an interlaboratory reproducibility of better than 1%. In contrast, the activation potentials required to induce protein CIU transitions varied between the three laboratories. To address these differences, three source assemblies were constructed with an updated ion activation hardware design utilizing higher mechanical tolerance specifications. The production-grade assemblies were found to produce highly consistent CIU data for intact antibodies, exhibiting high precision ion CCS and CIU transition values, thus opening the door to establishing databases of CIU fingerprints to support future biomolecular classification efforts.


Assuntos
Desdobramento de Proteína , Proteínas , Humanos , Reprodutibilidade dos Testes , Proteínas/química , Espectrometria de Massas/métodos , Íons/química
5.
Anal Bioanal Chem ; 414(18): 5683-5693, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35426495

RESUMO

Isomerization of aspartic acid (Asp) residues in long-lived proteins is a key feature associated with neurodegenerative proteinopathies such as Alzheimer's disease (AD). Recently, using ultra high-performance liquid chromatography (UHPLC) coupled with drift tube ion mobility mass spectrometry (DTIMS-MS), we documented the extensive Asp isomerization in amyloid-beta (Aß) peptides depositing in the extracellular cortical plaques (senile plaques) of the AD brain. Aß1-15 was estimated to be ~ 85% isomerized, while Aß4-15 another major constituent of these senile plaques was ~ 50% isomerized in AD brain. Low resolution on the standard demultiplexed ion mobility resulted in poor separation of these N-truncated Aß isomers in the ion mobility domain. Here, using the same ion multiplexed dataset, we applied new post-acquisition data reconstruction technique, high-resolution demultiplexing (HRdm), to improve the resolution of these Aß isomers in the ion mobility dimension. We demonstrate that for the complex proteomic AD brain digests, HRdm could successfully resolve three out of four major Asp isomers of Aß1-15. For Aß2-15 and Aß4-15, the significant resolution enhancement in the HRdm data resulted in baseline peak separation of the respective Asp isomers. An analysis of two-peak resolution (Rpp) and peak-to-peak separation (ΔP) indicated twofold enhancement for the Asp-isomerized Aß species. HRdm performed with an effective resolving power (Rp) of between 150 and 160 for the highest deconvolution settings in comparison to ~ 40 to 65 in the standard settings. These major resolution improvements in the ion mobility domain for the endogenous Aß isomers demonstrate the feasibility of in situ measurement of peptide isomers and their role in the mechanism of amyloid plaque formation in AD.


Assuntos
Doença de Alzheimer , Placa Amiloide , Doença de Alzheimer/metabolismo , Peptídeos beta-Amiloides/química , Encéfalo/metabolismo , Humanos , Isomerismo , Placa Amiloide/metabolismo , Proteômica , Software
6.
Anal Chim Acta ; 1191: 339297, 2022 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-35033277

RESUMO

Hydrophilic interaction liquid chromatography (HILIC) coupled to drift tube ion mobility spectrometry (DTIMS) was used to separate diastereomers of five-unit oligonucleotides containing 0, 1, 2 or 3 phosphorothioate (PS) linkages. Multiplexed DTIMS (where ions are pulsed into the drift tube according to a pre-encoded sequence) and post-acquisition processing using an innovative demultiplexing tool were investigated. The electric field inside the drift tube was optimized to achieve the highest resolving power. The entrance voltage providing the best two-peak resolution was -1000V with 3-bit multiplexing. Under optimized conditions, the eight diastereomers of an oligonucleotide with three PS linkages (5'-TC∗G∗T∗G-3') could be separated unambiguously. Indeed, those diastereomers differed in their collision cross section (CCS) values. The minimal CCS values difference between two adjacent diastereomers was 0.9% with maximal RSD on CCS values of 0.3%. The use of multiplexed ion mobility and the novel high-resolution demultiplexing tool represents a real breakthrough for resolution enhancement of diastereomers in linear DTIMS.


Assuntos
Espectrometria de Mobilidade Iônica , Oligonucleotídeos , Cromatografia Líquida , Íons , Espectrometria de Massas
7.
J Proteome Res ; 21(3): 798-807, 2022 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-34382401

RESUMO

The ability to improve the data quality of ion mobility-mass spectrometry (IM-MS) measurements is of great importance for enabling modular and efficient computational workflows and gaining better qualitative and quantitative insights from complex biological and environmental samples. We developed the PNNL PreProcessor, a standalone and user-friendly software housing various algorithmic implementations to generate new MS-files with enhanced signal quality and in the same instrument format. Different experimental approaches are supported for IM-MS based on Drift-Tube (DT) and Structures for Lossless Ion Manipulations (SLIM), including liquid chromatography (LC) and infusion analyses. The algorithms extend the dynamic range of the detection system, while reducing file sizes for faster and memory-efficient downstream processing. Specifically, multidimensional smoothing improves peak shapes of poorly defined low-abundance signals, and saturation repair reconstructs the intensity profile of high-abundance peaks from various analyte types. Other functionalities are data compression and interpolation, IM demultiplexing, noise filtering by low intensity threshold and spike removal, and exporting of acquisition metadata. Several advantages of the tool are illustrated, including an increase of 19.4% in lipid annotations and a two-times faster processing of LC-DT IM-MS data-independent acquisition spectra from a complex lipid extract of a standard human plasma sample. The software is freely available at https://omics.pnl.gov/software/pnnl-preprocessor.


Assuntos
Espectrometria de Mobilidade Iônica , Lipídeos , Cromatografia Líquida/métodos , Humanos , Espectrometria de Mobilidade Iônica/métodos , Íons , Espectrometria de Massas/métodos , Fluxo de Trabalho
8.
Anal Chem ; 93(48): 16166-16174, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34808055

RESUMO

Ion mobility-mass spectrometry (IM-MS) and collision-induced unfolding (CIU) assays of monoclonal antibody (mAb)-based biotherapeutics have proven sensitive to disulfide bridge structures, glycosylation patterns, and small molecule conjugation levels. Despite promising prior reports detailing the capabilities of IM-MS and CIU to differentiate biosimilars, generic mAb therapeutics, there remain questions surrounding the sensitivity of CIU to mAb structure changes that occur upon stress, the reproducibility of such measurements across IM-MS platforms, and the correlation between CIU and differential scanning calorimetry (DSC) datasets. In this report, we describe a comprehensive IM-MS and CIU dataset acquired for three Infliximabs: Remicade, Inflectra, and Renflexis. We subject each infliximab sample to forced degradation through heat stress and observe broadly similar yet subtly different stability patterns for these three biotherapeutics. We find that CIU is capable of tracking differences in mAb higher-order structure (HOS) imparted during forced heat stress degradation and that DSC is less sensitive to these alterations in comparison. Furthermore, we collected our comprehensive IM-MS and CIU data across two instrument platforms (Waters G2 and Agilent 6560), with both producing similar abilities to differentiate mAbs while also revealing minor differences between the results obtained on the two instruments. Finally, we demonstrate that CIU-based heatmaps and classification allow for rapid assessment of the most differentiating charge states for the analysis of infliximab, and using multiplexed classification, we conservatively estimate a 30-fold improvement in the time required to perform mAb stability and HOS measurements over standard DSC tools.


Assuntos
Medicamentos Biossimilares , Desdobramento de Proteína , Resposta ao Choque Térmico , Infliximab , Espectrometria de Massas , Reprodutibilidade dos Testes
9.
J Am Soc Mass Spectrom ; 32(10): 2592-2603, 2021 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34515480

RESUMO

Ion mobility as an additional separation dimension can help to resolve and annotate metabolite and lipid biomarkers and provides important information about the components in a sample. Identifying relevant information in the resulting data is challenging because of the complexity of the data and data evaluation strategies for both targeted or nontargeted workflows. Frequently, feature analysis is used as a first step to search for differences between samples in discovery workflows. However, follow-up experimentation often leads to more targeted data extraction methods. In both cases, optimizing data sets for data extraction can make an important contribution to the overall results. In this work, we evaluate the effect of experimental conditions including acquisition sampling rate and data pretreatment on lipid standards and lipid extracts as examples of complex biological samples analyzed by liquid chromatography coupled to drift time ion mobility quadrupole time-of-flight mass spectrometry. The results show that a reduction of both peak variation and background noise can be achieved by optimizing the sampling rate. The use of data pretreatment including data smoothing, intensity thresholding, and spike removal also play an important role in improving detection and annotation of analytes from complex biological samples, whereas nonoptimal data sampling rates and preprocessing can lead to adverse effects including the loss or alternation of small, or closely eluting, low-abundant peaks.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Mobilidade Iônica/métodos , Lipídeos/análise , Células Hep G2 , Humanos , Limite de Detecção , Lipídeos/química , Manejo de Espécimes
10.
Bioinformatics ; 37(22): 4193-4201, 2021 11 18.
Artigo em Inglês | MEDLINE | ID: mdl-34145874

RESUMO

MOTIVATION: Ion mobility spectrometry (IMS) separations are increasingly used in conjunction with mass spectrometry (MS) for separation and characterization of ionized molecular species. Information obtained from IMS measurements includes the ion's collision cross section (CCS), which reflects its size and structure and constitutes a descriptor for distinguishing similar species in mixtures that cannot be separated using conventional approaches. Incorporating CCS into MS-based workflows can improve the specificity and confidence of molecular identification. At present, there is no automated, open-source pipeline for determining CCS of analyte ions in both targeted and untargeted fashion, and intensive user-assisted processing with vendor software and manual evaluation is often required. RESULTS: We present AutoCCS, an open-source software to rapidly determine CCS values from IMS-MS measurements. We conducted various IMS experiments in different formats to demonstrate the flexibility of AutoCCS for automated CCS calculation: (i) stepped-field methods for drift tube-based IMS (DTIMS), (ii) single-field methods for DTIMS (supporting two calibration methods: a standard and a new enhanced method) and (iii) linear calibration for Bruker timsTOF and non-linear calibration methods for traveling wave based-IMS in Waters Synapt and Structures for Lossless Ion Manipulations. We demonstrated that AutoCCS offers an accurate and reproducible determination of CCS for both standard and unknown analyte ions in various IMS-MS platforms, IMS-field methods, ionization modes and collision gases, without requiring manual processing. AVAILABILITY AND IMPLEMENTATION: https://github.com/PNNL-Comp-Mass-Spec/AutoCCS. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online. Demo datasets are publicly available at MassIVE (Dataset ID: MSV000085979).


Assuntos
Espectrometria de Mobilidade Iônica , Software , Espectrometria de Massas/métodos , Íons
11.
J Am Soc Mass Spectrom ; 32(8): 2019-2032, 2021 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-33835810

RESUMO

Characterization and monitoring of post-translational modifications (PTMs) by peptide mapping is a ubiquitous assay in biopharmaceutical characterization. Often, this assay is coupled to reversed-phase liquid chromatographic (LC) separations that require long gradients to identify all components of the protein digest and resolve critical modifications for relative quantitation. Incorporating ion mobility (IM) as an orthogonal separation that relies on peptide structure can supplement the LC separation by providing an additional differentiation filter to resolve isobaric peptides, potentially reducing ambiguity in identification through mobility-aligned fragmentation and helping to reduce the run time of peptide mapping assays. A next-generation high-resolution ion mobility (HRIM) technique, based on structures for lossless ion manipulations (SLIM) technology with a 13 m ion path, provides peak capacities and higher resolving power that rivals traditional chromatographic separations and, owing to its ability to resolve isobaric peptides that coelute in faster chromatographic methods, allows for up to 3× shorter run times than conventional peptide mapping methods. In this study, the NIST monoclonal antibody IgG1κ (NIST RM 8671, NISTmAb) was characterized by LC-HRIM-MS and LC-HRIM-MS with collision-induced dissociation (HRIM-CID-MS) using a 20 min analytical method. This approach delivered a sequence coverage of 96.5%. LC-HRIM-CID-MS experiments provided additional confidence in sequence determination. HRIM-MS resolved critical oxidations, deamidations, and isomerizations that coelute with their native counterparts in the chromatographic dimension. Finally, quantitative measurements of % modification were made using only the m/z-extracted HRIM arrival time distributions, showing good agreement with the reference liquid-phase separation. This study shows, for the first time, the analytical capability of HRIM using SLIM technology for enhancing peptide mapping workflows relevant to biopharmaceutical characterization.


Assuntos
Espectrometria de Massas/métodos , Mapeamento de Peptídeos/métodos , Peptídeos/análise , Peptídeos/metabolismo , Anticorpos Monoclonais/análise , Anticorpos Monoclonais/química , Produtos Biológicos/análise , Produtos Biológicos/química , Ensaios de Triagem em Larga Escala , Espectrometria de Mobilidade Iônica , Íons/química , Isomerismo , Peptídeos/química , Processamento de Proteína Pós-Traducional , Controle de Qualidade
12.
Anal Chem ; 92(23): 15489-15496, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33166123

RESUMO

Native ion mobility-mass spectrometry (IM-MS) is capable of revealing much that remains unknown within the structural proteome, promising such information on refractory protein targets. Here, we report the development of a unique drift tube IM-MS (DTIM-MS) platform, which combines high-energy source optics for improved collision induced unfolding (CIU) experiments and an electromagnetostatic cell for electron capture dissociation (ECD). We measured a series of high precision collision cross section (CCS) values for protein and protein complex ions ranging from 6-1600 kDa, exhibiting an average relative standard deviation (RSD) of 0.43 ± 0.20%. Furthermore, we compare our CCS results to previously reported DTIM values, finding strong agreement across similarly configured instrumentation (average RSD of 0.82 ± 0.73%), and systematic differences for DTIM CCS values commonly used to calibrate traveling-wave IM separators (-3% average RSD). Our CIU experiments reveal that the modified DTIM-MS instrument described here achieves enhanced levels of ion activation when compared with any previously reported IM-MS platforms, allowing for comprehensive unfolding of large multiprotein complex ions as well as interplatform CIU comparisons. Using our modified DTIM instrument, we studied two protein complexes. The enhanced CIU capabilities enable us to study the gas phase stability of the GroEL 7-mer and 14-mer complexes. Finally, we report CIU-ECD experiments for the alcohol dehydrogenase tetramer, demonstrating improved sequence coverage by combining ECD fragmentation integrated over multiple CIU intermediates. Further improvements for such native top-down sequencing experiments were possible by leveraging IM separation, which enabled us to separate and analyze CID and ECD fragmentation simultaneously.


Assuntos
Elétrons , Espectrometria de Massas/métodos , Desdobramento de Proteína , Proteínas/química
13.
J Am Soc Mass Spectrom ; 31(12): 2437-2442, 2020 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-32841564

RESUMO

Mass spectrometry imaging (MSI) is a powerful technique for the label-free spatially resolved analysis of biological tissues. Coupling ion mobility (IM) separation with MSI allows for separation of isobars in the mobility dimension and increases confidence of peak assignments. Recently, imaging experiments have been implemented on several commercially available and custom-designed ion mobility instruments, making IM-MSI experiments more broadly accessible to the MS community. However, the absence of open access data analysis software for IM-MSI systems presents a bottleneck. Herein, we present an imaging workflow to visualize IM-MSI data produced on the Agilent 6560 ion mobility quadrupole time-of-flight system. Specifically, we have developed a Python script, the ion mobility-mass spectrometry image creation script (IM-MSIC), which interfaces Agilent's Mass Hunter Mass Profiler software with the MacCoss lab's Skyline software and generates drift time and mass-to-charge-selected ion images. In the workflow, Mass Profiler is used for an untargeted feature detection. The IM-MSIC script mediates user input of data, extracts ion chronograms utilizing Skyline's command-line interface, and then proceeds toward ion image generation within a single user interface. Ion image postprocessing is subsequently performed using different tools implemented in accompanying scripts. Though the current work only showcases Agilent IM-MSI data, this workflow can be readily adapted for use with most major instrument vendors.


Assuntos
Espectrometria de Mobilidade Iônica/métodos , Software , Humanos , Processamento de Imagem Assistida por Computador/métodos , Fluxo de Trabalho
14.
Anal Chem ; 92(14): 9482-9492, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32628451

RESUMO

A combined data acquisition and data processing strategy for improving the sensitivity and resolution of ion mobility measurements is described. This strategy is implemented on a commercially available drift tube ion mobility-mass spectrometry (IM-MS) instrument and utilizes both an existing ion multiplexing strategy to achieve up to an 8-fold gain in ion signal and a new postacquisition data reconstruction technique, termed "high resolution demultiplexing" (HRdm), to improve resolution in the ion mobility dimension. A series of isomeric mixtures were qualitatively investigated with HRdm, including biologically relevant lipids and carbohydrates, which were successfully resolved by HRdm, including two monosaccharide regioisomers which differed in drift time by only 0.8%. For a complex trisaccharide isomer mixture, HRdm was able to resolve 5 out of 6 components. An analysis of two-peak resolution (Rpp) and peak-to-peak separation (ΔP) indicated that HRdm performs with an effective resolving power (Rp) of between 180 to 250 for the highest deconvolution settings. Overall analysis times and drift time measurement precision were found to be unaffected between standard and HRdm processed data sets, which allowed statistically identical collision cross section values to be directly determined from all ion mobility spectra.


Assuntos
Carboidratos/química , Espectrometria de Mobilidade Iônica/instrumentação , Espectrometria de Mobilidade Iônica/métodos , Lipídeos/química , Isomerismo , Espectrometria de Massas , Software , Fatores de Tempo
15.
Anal Bioanal Chem ; 411(24): 6265-6274, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31302708

RESUMO

This study of ion accumulation/release behavior relevant to ion mobility-mass spectrometry (IM-MS) as employed for non-targeted metabolomics involves insight from theoretical studies, and controlled reference experiments involving measurement of low and high molecular mass metabolites in varying concentrations within a complex matrix (yeast extracts). Instrumental settings influencing ion trapping (accumulation time) and release conditions in standard and multiplexed operation have been examined, and translation of these insights to liquid chromatography (LC) in combination with drift tube IM-MS measurements has been made. The focus of the application is non-targeted metabolomics using carefully selected samples to allow quantitative interpretations to be made. Experimental investigation of the IM-MS ion utilization efficiency particularly focusing on the use of the Hadamard transform multiplexing with 4-bit pseudo-random pulsing sequence for assessment of low and high molecular mass metabolites is compared with theoretical modeling of gas-phase behavior of small and large molecules in the IM trapping funnel. Increasing the trapping time for small metabolites with standard IM-MS operation is demonstrated to have a deleterious effect on maintaining a quantitative representation of the metabolite abundance. The application of these insights to real-world non-targeted metabolomics assessment of intracellular extracts from biotechnologically relevant production processes is presented, and the results were compared to LC×IM-MS measurements of the same samples. Spiking of a uniformly 13C-labeled yeast extract (as a standard matrix) with varying amounts of natural metabolites is used to assess the linearity and sensitivity according to the instrument mode of operation (i.e., LC-MS, LC×IM-MS, and LC×[multiplexed]IM-MS). When comparing metabolite quantification using standard and multiplexed operation, sensitivity gain factors of 2-8 were obtained for metabolites with m/z below 250. Taken together, the simulation and experimental results of this study provide insight for optimizing measurement conditions for metabolomics and highlight the need for implementation of multiplexing strategies using short trapping times as relative quantification (e.g., in the context with non-targeted differential analysis) with sufficient sensitivity and working range is a requirement in this field of application.


Assuntos
Espectrometria de Mobilidade Iônica/métodos , Espectrometria de Massas/métodos , Metabolômica , Aminoácidos/metabolismo , Íons , Padrões de Referência
16.
Anal Chem ; 91(13): 8137-8146, 2019 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-31194508

RESUMO

Collision-induced unfolding (CIU) of protein ions and their noncovalent complexes offers relatively rapid access to a rich portfolio of biophysical information, without the need to tag or purify proteins prior to analysis. Such assays have been characterized extensively for a range of therapeutic proteins, proving exquisitely sensitive to alterations in protein sequence, structure, and post-translational modification state. Despite advantages over traditional probes of protein stability, improving the throughput and information content of gas-phase protein unfolding assays remains a challenge for current instrument platforms. In this report, we describe modifications to an Agilent 6560 drift tube ion mobility-mass spectrometer in order to perform robust, simultaneous CIU across all precursor ions detected. This approach dramatically increases the speed associated with typical CIU assays, which typically involve mass selection of narrow m/ z regions prior to collisional activation, and thus their development requires a comprehensive assessment of charge-stripping reactions that can unintentionally pollute CIU data with chemical noise when more than one precursor ion is allowed to undergo simultaneous activation. By studying the unfolding and dissociation of intact antibody ions, a key analyte class associated with biotherapeutics, we reveal a predictive relationship between the precursor charge state, the amount of buffer components bound to the ions of interest, and the amount of charge stripping detected. We then utilize our knowledge of antibody charge stripping to rapidly capture CIU data for a range of antibody subclasses and subtypes across all charge states simultaneously, demonstrating a strong charge state dependence on the information content of CIU. Finally, we demonstrate that CIU data collection times can be further reduced by scanning fewer voltage steps, enabling us to optimize the throughput of our improved CIU methods and confidently differentiate antibody variant ions using ∼20% of the data typically collected during CIU. Taken together, our results characterize a new instrument platform for biotherapeutic stability measurements with dramatically improved throughput and information content.

17.
Anal Chem ; 91(13): 8025-8035, 2019 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-31074960

RESUMO

Analysis of oxylipins by liquid chromatography mass spectrometry (LC/MS) is challenging because of the small mass range occupied by this diverse lipid class, the presence of numerous structural isomers, and their low abundance in biological samples. Although highly sensitive LC/MS/MS methods are commonly used, further separation is achievable by using drift tube ion mobility coupled with high-resolution mass spectrometry (DTIM-MS). Herein, we present a combined analytical and computational method for the identification of oxylipins and fatty acids. We use a reversed-phase LC/DTIM-MS workflow able to profile and quantify (based on chromatographic peak area) the oxylipin and fatty acid content of biological samples while simultaneously acquiring full scan and product ion spectra. The information regarding accurate mass, collision-cross-section values in nitrogen (DTCCSN2), and retention times of the species found are compared to an internal library of lipid standards as well as the LIPID MAPS Structure Database by using specifically developed processing tools. Features detected within the DTCCSN2 and m/ z ranges of the analyzed standards are flagged as oxylipin-like species, which can be further characterized using drift-time alignment of product and precursor ions distinctive of DTIM-MS. This not only helps identification by reducing the number of annotations from LIPID MAPS but also guides discovery studies of potentially novel species. Testing the methodology on Salmonella enterica serovar Typhimurium-infected murine bone-marrow-derived macrophages and thrombin activated human platelets yields results in agreement with literature. This workflow has also annotated features as potentially novel oxylipins, confirming its ability in providing further insights into lipid analysis of biological samples.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Eicosanoides/análise , Ácidos Graxos/análise , Oxilipinas/análise , Espectrometria de Massas em Tandem/métodos , Animais , Células Cultivadas , Humanos , Espectrometria de Mobilidade Iônica/métodos , Camundongos Endogâmicos C57BL
18.
Rapid Commun Mass Spectrom ; 33 Suppl 2: 66-74, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30801790

RESUMO

RATIONALE: The wide chemical diversity and complex matrices inherent to metabolomics still pose a challenge to current analytical approaches for metabolite screening. Although dedicated front-end separation techniques combined with high-resolution mass spectrometry set the benchmark from an analytical point of view, the increasing number of samples and sample complexity demand for a compromise in terms of selectivity, sensitivity and high-throughput analyses. METHODS: Prior to low-field drift tube ion mobility (IM) separation and quadrupole time-of-flight mass spectrometry (QTOFMS) detection, rapid ultrahigh-performance liquid chromatography separation was used for analysis of different concentration levels of dansylated metabolites present in a yeast cell extract. For identity confirmation of metabolites at the MS2 level, an alternating frame approach was chosen and two different strategies were tested: a data-independent all-ions acquisition and a quadrupole broad band isolation (Q-BBI) directed by IM drift separation. RESULTS: For Q-BBI analysis, the broad mass range isolation was successfully optimized in accordance with the distinctive drift time to m/z correlation of the dansyl derivatives. To guarantee comprehensive sampling, a broad mass isolation window of 70 Da was employed. Fragmentation was performed via collision-induced dissociation, applying a collision energy ramp optimized for the dansyl derivatives. Both approaches were studied in terms of linear dynamic range and repeatability employing ethanolic extracts of Pichia pastoris spiked with 1 µM metabolite mixture. Example data obtained for histidine and glycine showed that drift time precision (<0.01 to 0.3% RSD, n = 5) compared very well with the data reported in an earlier IM-TOFMS-based study. CONCLUSIONS: Chimeric mass spectra, inherent to data-independent analysis approaches, are reduced when using a drift time directed Q-BBI approach. Additionally, an improved linear dynamic working range was observed, representing, together with a rapid front-end separation, a powerful approach for metabolite screening.


Assuntos
Espectrometria de Massas/métodos , Metabolômica/métodos , Proteínas de Saccharomyces cerevisiae/química , Saccharomyces cerevisiae/química , Metaboloma , Saccharomyces cerevisiae/genética , Saccharomyces cerevisiae/metabolismo , Proteínas de Saccharomyces cerevisiae/genética , Proteínas de Saccharomyces cerevisiae/metabolismo
19.
Mass Spectrom Rev ; 38(3): 291-320, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30707468

RESUMO

Here we present a guide to ion mobility mass spectrometry experiments, which covers both linear and nonlinear methods: what is measured, how the measurements are done, and how to report the results, including the uncertainties of mobility and collision cross section values. The guide aims to clarify some possibly confusing concepts, and the reporting recommendations should help researchers, authors and reviewers to contribute comprehensive reports, so that the ion mobility data can be reused more confidently. Starting from the concept of the definition of the measurand, we emphasize that (i) mobility values (K0 ) depend intrinsically on ion structure, the nature of the bath gas, temperature, and E/N; (ii) ion mobility does not measure molecular surfaces directly, but collision cross section (CCS) values are derived from mobility values using a physical model; (iii) methods relying on calibration are empirical (and thus may provide method-dependent results) only if the gas nature, temperature or E/N cannot match those of the primary method. Our analysis highlights the urgency of a community effort toward establishing primary standards and reference materials for ion mobility, and provides recommendations to do so. © 2019 The Authors. Mass Spectrometry Reviews Published by Wiley Periodicals, Inc.

20.
Metabolomics ; 14(4): 52, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29576760

RESUMO

INTRODUCTION: Data processing is one of the biggest problems in metabolomics, given the high number of samples analyzed and the need of multiple software packages for each step of the processing workflow. OBJECTIVES: Merge in the same platform the steps required for metabolomics data processing. METHODS: KniMet is a workflow for the processing of mass spectrometry-metabolomics data based on the KNIME Analytics platform. RESULTS: The approach includes key steps to follow in metabolomics data processing: feature filtering, missing value imputation, normalization, batch correction and annotation. CONCLUSION: KniMet provides the user with a local, modular and customizable workflow for the processing of both GC-MS and LC-MS open profiling data.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...