Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
MAGMA ; 19(2): 78-87, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16779563

RESUMO

OBJECTIVE: Quantification of the cerebrospinal fluid (CSF) flow through the aqueduct of Sylvius by means of magnetic resonance imaging (MRI) is subject to interobserver variability due to the region of interest (ROI) selection. Our objective is to develop a semiautomatic measurement method to achieve reproducible quantitative analysis of CSF flow rate and stroke volume. MATERIAL AND METHODS: MR examinations were performed using a 1.5 T scanner with a phase contrast sequence (velocity encoding [V(enc)] of 20 cm/s, FOV = 160, 3 mm slice thickness, image matrix size = 256x256, TR = 53 ms, TE = 11 ms, NSA = 2, flip angle = 15 degrees and 23 frames per cardiac cycle with peripheral retrospective pulse gating). Our method was developed using MATLAB R7. Errors introduced by background offset and possible aliased pixels were automatically detected and corrected if necessary in order to calculate the flow parameters that characterize CSF dynamics. The semiautomatic seed method reproducibility was evaluated and compared with the radius method by two observers analysing 21 healthy subjects. RESULTS: The measurements using the semiautomatic seed method reduced the interobservers variability (intra-class correlation [ICC] = 1.0 for stroke volume and for volumetric flow rate) versus the radius method (ICC = 0.46 for stroke volume and 0.65 for flow rate). Normal stroke volume (39.19 +/- 20.13 microl/cycle), flow rate (3.81 +/- 2.81 ml/min), maximal mean systolic velocity (5.27 +/- 1.3 cm/s) and maximal mean diastolic velocity (4.20 +/- 1.4 cm/s) were calculated with the half moon and aliasing corrected seed method. CONCLUSIONS: Semiautomatic measurements (seed method with half moon background and aliasing correction) allow a generalization of the calculus of flow parameters with great consistency and independency of the operator.


Assuntos
Algoritmos , Aqueduto do Mesencéfalo/fisiologia , Líquido Cefalorraquidiano/fisiologia , Imageamento por Ressonância Magnética/métodos , Volume Sistólico/fisiologia , Aqueduto do Mesencéfalo/anatomia & histologia , Pressão do Líquido Cefalorraquidiano/fisiologia , Circulação Cerebrovascular/fisiologia , Meios de Contraste , Humanos , Aumento da Imagem , Imageamento por Ressonância Magnética/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...