Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
NMR Biomed ; 35(5): e4656, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34962689

RESUMO

In this study, the performance of an integrated body-imaging array for 7 T with 32 radiofrequency (RF) channels under consideration of local specific absorption rate (SAR), tissue temperature, and thermal dose limits was evaluated and the imaging performance was compared with a clinical 3 T body coil. Thirty-two transmit elements were placed in three rings between the bore liner and RF shield of the gradient coil. Slice-selective RF pulse optimizations for B1 shimming and spokes were performed for differently oriented slices in the body under consideration of realistic constraints for power and local SAR. To improve the B1+ homogeneity, safety assessments based on temperature and thermal dose were performed to possibly allow for higher input power for the pulse optimization than permissible with SAR limits. The results showed that using two spokes, the 7 T array outperformed the 3 T birdcage in all the considered regions of interest. However, a significantly higher SAR or lower duty cycle at 7 T is necessary in some cases to achieve similar B1+ homogeneity as at 3 T. The homogeneity in up to 50 cm-long coronal slices can particularly benefit from the high RF shim performance provided by the 32 RF channels. The thermal dose approach increases the allowable input power and the corresponding local SAR, in one example up to 100 W/kg, without limiting the exposure time necessary for an MR examination. In conclusion, the integrated antenna array at 7 T enables a clinical workflow for body imaging and comparable imaging performance to a conventional 3 T clinical body coil.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Temperatura
2.
NMR Biomed ; 34(7): e4515, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33942938

RESUMO

The aim of the current study was to investigate the performance of integrated RF transmit arrays with high channel count consisting of meander microstrip antennas for body imaging at 7 T and to optimize the position and number of transmit elements. RF simulations using multiring antenna arrays placed behind the bore liner were performed for realistic exposure conditions for body imaging. Simulations were performed for arrays with as few as eight elements and for arrays with high channel counts of up to 48 elements. The B1+ field was evaluated regarding the degrees of freedom for RF shimming in the abdomen. Worst-case specific absorption rate (SARwc ), SAR overestimation in the matrix compression, the number of virtual observation points (VOPs) and SAR efficiency were evaluated. Constrained RF shimming was performed in differently oriented regions of interest in the body, and the deviation from a target B1+ field was evaluated. Results show that integrated multiring arrays are able to generate homogeneous B1+ field distributions for large FOVs, especially for coronal/sagittal slices, and thus enable body imaging at 7 T with a clinical workflow; however, a low duty cycle or a high SAR is required to achieve homogeneous B1+ distributions and to exploit the full potential. In conclusion, integrated arrays allow for high element counts that have high degrees of freedom for the pulse optimization but also produce high SARwc , which reduces the SAR accuracy in the VOP compression for low-SAR protocols, leading to a potential reduction in array performance. Smaller SAR overestimations can increase SAR accuracy, but lead to a high number of VOPs, which increases the computational cost for VOP evaluation and makes online SAR monitoring or pulse optimization challenging. Arrays with interleaved rings showed the best results in the study.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Ondas de Rádio , Simulação por Computador , Humanos , Masculino , Modelos Biológicos
3.
PLoS One ; 14(9): e0222452, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31513637

RESUMO

PURPOSE: A 32-channel parallel transmit (pTx) add-on for 7 Tesla whole-body imaging is presented. First results are shown for phantom and in-vivo imaging. METHODS: The add-on system consists of a large number of hardware components, including modulators, amplifiers, SAR supervision, peripheral devices, a control computer, and an integrated 32-channel transmit/receive body array. B1+ maps in a phantom as well as B1+ maps and structural images in large volunteers are acquired to demonstrate the functionality of the system. EM simulations are used to ensure safe operation. RESULTS: Good agreement between simulation and experiment is shown. Phantom and in-vivo acquisitions show a field of view of up to 50 cm in z-direction. Selective excitation with 100 kHz sampling rate is possible. The add-on system does not affect the quality of the original single-channel system. CONCLUSION: The presented 32-channel parallel transmit system shows promising performance for ultra-high field whole-body imaging.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído
4.
Magn Reson Imaging ; 53: 164-172, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30053430

RESUMO

Prostate MRI is an important tool to diagnose and characterize cancer. High local sensitivity and good parallel imaging performance are of paramount importance for diagnostic quality and efficiency. The purpose of this work was to evaluate stacked resonators as part of a surface receiver array for prostate MRI at 3 Tesla. A base array of 6-channels consisting of a flexible anterior and a rigid posterior part were built each with three loop coils. A pair of stacked resonators was added concentrically to the center loops (anterior and posterior) of the base array. The evaluated stacked resonators were butterflies, composites and dipoles which yielded a total of three 8-channel arrays. The arrays were compared using noise correlations and single-channel signal-to-noise ratio maps in a phantom. Combined signal-to-noise ratio maps and parallel imaging performances were measured and compared in vivo in 6 healthy volunteers. The results were compared to the base and a commercial array. The SNR values in the prostate yielded by all the arrays were not statistically different using fully sampled k-space. However, significant differences were found in the parallel imaging performance of the arrays. More specifically, up to 88% geometric factor reduction was found compared to the commercial array and up to 83% reduction compared to the base array using butterfly coils. Thus, signal-to-noise ratio improvements were observed with stacked resonators when using parallel imaging. The use of stacked elements, in particular butterfly coils, can improve the performance of a base array consisting solely of single loops when using parallel imaging. We expect prostate MRI at 3 Tesla to benefit from using combinations of single loops and stacked resonators.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Desenho de Equipamento , Voluntários Saudáveis , Humanos , Masculino , Imagens de Fantasmas , Sensibilidade e Especificidade , Razão Sinal-Ruído
5.
Phys Rev Lett ; 107(17): 176806, 2011 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-22107558

RESUMO

We use a general diagrammatic formalism based on a local conductivity approach to compute electronic transport in continuous media with long-range disorder, in the absence of quantum interference effects. The method allows us then to investigate the interplay of dissipative processes and random drifting of electronic trajectories in the high-temperature regime of quantum Hall transitions. We obtain that the longitudinal conductance σ(xx) scales with an exponent κ=0.767±0.002 in agreement with the value κ=10/13 conjectured from analogies to classical percolation. We also derive a microscopic expression for the temperature-dependent peak value of σ(xx), useful to extract κ from experiments.