1.
Fam Med ; 28(3): 189-92, 1996 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8900551

RESUMO

BACKGROUND AND OBJECTIVES: Automated finger blood pressure devices are marketed to consumers as accurate devices to monitor blood pressure. Our study compared the accuracy of these devices to standard blood pressure cuffs. METHODS: Three models were purchased and tested against standard cuff measurement. With the patient relaxed and seated for at least 5 minutes, cuff measurement was performed. The blood pressure was then measured by the three finger devices in quick succession. RESULTS: No statistically significant correlation was shown between cuff measurement and the finger device measurements. CONCLUSIONS: Patients should be cautioned that these devices may not be able to perform as they are marketed.


Assuntos
Determinação da Pressão Arterial/instrumentação , Dedos/irrigação sanguínea , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Estudos de Avaliação como Assunto , Feminino , Humanos , Hipertensão/diagnóstico , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade