Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Diagn Interv Imaging ; 101(7-8): 489-497, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32007470

RESUMO

PURPOSE: The purpose of this study was to compare an established postmortem contrast medium mixture based on polyethylene glycol (PEG) to an isotonic crystalloid with acetated Ringer solution (AR) as the base, both mixed with water-soluble iodinated contrast medium for postmortem computed tomography angiography (PMCTA) with the aim to avoid alterations of the corpse during autopsy. MATERIALS AND METHODS: The study included 20 cadavers; 10 had PMCTA with AR and 10 with PEG. PMCTA images were analyzed with respect to image quality, vascular contrast patterns and artifacts. Autopsy was evaluated for visual, organ, vessel and haptic alterations. The Wilcoxon rank sum test was used to search for differences in image quality between the two groups. Statistical significance was set at P<0.05. RESULTS: AR provided excellent contrast within the right coronary artery (P<0.001) but a lack of contrast within the left coronary artery (P=0.008) whereas PEG showed the opposite. A better image quality was observed in the PEG group by comparison with the AR group for right common carotid artery (P=0.03), left common carotid artery (P=0.01) and left coronary artery (P=0.008). No differences were found for ascending aorta (P=0.65), aortic arch (P=0.09), right circle of Willis (P=0.17), left circle of Willis (P=0.08), inferior vena cava (P=0.07) and abdominal aorta (P=0.08). Severe extravasation occurred in all (10/10; 100%) cadavers in the AR group but in none (0/10; 0%) in the PEG group (P<0.001). At autopsy, visual alteration with lilac discoloration of the face was observed in 4/10 cadavers (40%) in the AR group and in 9/10 cadavers (90%) in the PEG group (P=0.057). Haptic alterations were observed in 3/10 cadavers (30%) in the AR group and 10/10 cadavers (100%) in the PEG group (P=0.003). CONCLUSION: AR results in contrast medium mixture extravasation in all cadavers, but PEG altered the autopsy more severely. Both carrier substances result in specific substance-related artifacts and dependent opacification of the coronary arteries, but PEG is recommended for PMCTA exclusively with regard to diagnostic imaging.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Angiografia , Autopsia , Humanos , Tomografia Computadorizada por Raios X
2.
Leg Med (Tokyo) ; 16(5): 274-82, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25017308

RESUMO

OBJECTIVES: The purpose of this study was to correlate the occurrence of retrobulbar hemorrhage (RBH) with mechanism of injury, external signs and autopsy findings to postmortem computed tomography (PMCT). METHODS: Six-teen subjects presented with RBH and underwent PMCT, external inspection and conventional autopsy. External inspection was evaluated for findings of the bulbs, black eye, raccoon eyes and Battle's sign. Fractures of the viscerocranium, orbital lesions and RBH were evaluated by PMCT. Autopsy and PMCT was evaluated for orbital roof and basilar skull fracture. RESULTS: The leading manner of death was accident with central regulatory failure in cases of RBH (31.25%). Imaging showed a high sensitivity in detection of orbital roof and basilar skull fractures (100%), but was less specific compared to autopsy. Volume of RBH (0.1-2.4ml) correlated positively to the presence of Battle's sign (p<0.06) and the postmortem interval. Ecchymosis on external inspection correlated with RBH. There was a statistical significant correlation between bulbar lesion and RBH. Orbital roof fracture count weakly correlated with the total PMCT derived RBH volume. Maxillary hemosinus correlated to maxillary fractures, but not to RBH. CONCLUSIONS: RBH are a specific finding in forensically relevant head trauma. PMCT is an excellent tool in detecting and quantifying morphological trauma findings particularly in the viscerocranium, one of the most relevant "blind spots" of classic autopsy. PMCT was superior in detecting osseous lesions, scrutinizing autopsy as the gold standard.


Assuntos
Autopsia , Traumatismos Oculares/diagnóstico por imagem , Patologia Legal/métodos , Hemorragia Retrobulbar/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Humanos , Interpretação de Imagem Assistida por Computador , Hemorragia Retrobulbar/etiologia , Sensibilidade e Especificidade
3.
Br J Radiol ; 87(1036): 20130472, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24472728

RESUMO

OBJECTIVE: The purpose of this study was to retrospectively evaluate the sensitivity, specificity and accuracy of identifying methamphetamine (MA) internal payloads in "drug mules" by plain abdominal digital radiography (DR). METHODS: The study consisted of 35 individuals suspected of internal MA drug containers. A total of 59 supine digital radiographs were collected. An overall calculation regarding the diagnostic accuracy for all "drug mules" and a specific evaluation concerning the radiological appearance of drug packs as well as the rate of clearance and complications in correlation with the reader's experience were performed. The gold standard was the presence of secured drug packs in the faeces. RESULTS: There were 16 true-positive "drug mules" identified. DR of all drug carriers for Group 1 (forensic imaging experienced readers, n = 2) exhibited a sensitivity of 100%, a mean specificity of 76.3%, positive predictive value (PPV) of 78.5%, negative predictive value (NPV) of 100% and a mean accuracy 87.2%. Group 2 (inexperienced readers, n = 3) showed a lower sensitivity (93.7%), a mean specificity of 86%, a PPV of 86.5%, an NPV of 94.1% and a mean accuracy of 89.5%. The interrater agreement within Group 1 was 0.72 and within Group 2 averaged to 0.79, indicating a fair to very good agreement. CONCLUSION: DR is a valuable screening tool in cases of MA body packers with huge internal payloads being associated with a high diagnostic insecurity. Diagnostic insecurity on plain films may be overcome by low-dose CT as a cross-sectional imaging modality and addressed by improved radiological education in reporting drug carriers on imaging. ADVANCES IN KNOWLEDGE: Diagnostic signs (double-condom and halo signs) on digital plain radiography are specific in MA "drug mules", although DR is associated with high diagnostic insecurity and underreports the total internal payload.


Assuntos
Tráfico de Drogas , Metanfetamina , Intensificação de Imagem Radiográfica , Radiografia Abdominal/métodos , Adulto , Animais , Estudos Transversais , Tráfico de Drogas/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
4.
Leg Med (Tokyo) ; 11(6): 267-71, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19736034

RESUMO

Fractures and soft-tissue injuries of the neck are of great importance in forensic pathology, as they help in assessing whether strangulation took place, and if so, how severely. In this study, we examined the usefulness of post-mortem imaging with multislice computed tomography (MSCT) in detecting lesions of the laryngohyoid structures and the surrounding soft-tissues. For this purpose, we examined MSCT images of the neck of eight deceased persons who had suffered different types of strangulation and compared the findings with those obtained at the subsequent forensic autopsy. In six of the eight cases (75%), the fracture findings at autopsy were concordant with those found with MSCT. In the two non-congruent cases, MSCT revealed fractures, which were not discovered at autopsy. Soft-tissue haemorrhages were detected by autopsy in five cases, but only in one case with MSCT. MSCT does not suffice in detecting soft-tissue injuries. These preliminary results are promising regarding the detection of fractures in strangulation cases. If these results can be confirmed in larger studies, we believe that post-mortem MSCT may serve - in combination with a thorough external examination and a profound incident-scene investigation - as a useful decision-making tool regarding the necessity of further examinations, i.e. autopsy.


Assuntos
Asfixia/diagnóstico por imagem , Cartilagem Cricoide/lesões , Diagnóstico , Fraturas Ósseas/diagnóstico por imagem , Homicídio , Osso Hioide/lesões , Lesões do Pescoço/diagnóstico por imagem , Cartilagem Tireóidea/lesões , Adulto , Idoso , Autopsia , Cartilagem Cricoide/diagnóstico por imagem , Feminino , Humanos , Osso Hioide/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Suicídio , Cartilagem Tireóidea/diagnóstico por imagem , Tomografia Computadorizada por Raios X
5.
Eur Radiol ; 17(8): 2149-59, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17119974

RESUMO

The purpose of this study is to investigate the diagnostic potential of color-coded Doppler sonography (CCDS), power-Doppler (PD) and B-flow ultrasound in assessing the degree of extracranial internal carotid artery (ICA) stenosis in comparison to CT-angiography (MD-CTA). Thirty-two consecutive patients referred for CTA with 41 ICA-stenoses were included in this prospective study. MD-CTA was performed using a 64 row scanner with a CTDIvol of 13.1 mGy/cm. In CTA, CCDS, PD and B-flow, the degree of stenosis was evaluated by the minimal intrastenotic diameter in comparison to the poststenotic diameter. Two radiologists performed a quantitative evaluation of the stenoses in consensus blinded to the results of ultrasound. These were correlated to CTA, CCDS, PD and B-flow, intraoperative findings and clinical follow-up. Grading of the stenoses in B-flow ultrasound outperformed the other techniques in terms of accuracy with a correlation coefficient to CTA of 0.88, while PD and CCDS measurements yield coefficients of 0.74 and 0.70. Bland-Altman analysis additionally shows a very little bias of the three US methods between 0.5 and 3.2 %. There is excellent correlation (coefficient 0.88, CI 0.77-0.93) with 64-MD-CTA and B-flow ultrasound in terms of accuracy for intrastenotic and poststenotic diameter. Duplex sonography is useful for screening purposes.


Assuntos
Artéria Carótida Interna , Estenose das Carótidas/diagnóstico por imagem , Angiografia Cerebral/métodos , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Análise de Regressão , Sensibilidade e Especificidade , Ultrassonografia Doppler em Cores
6.
Eur J Radiol ; 60(3): 379-86, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16920314

RESUMO

PURPOSE: The objective of this study was to determine the agreement and diagnostic accuracy of high-resolution contrast enhanced magnetic resonance angiography (MRA) with integrated parallel acquisition techniques (iPAT), color coded duplex ultrasound (CCDS) and power Doppler ultrasound (PD) in the assessment of high-grade stenoses of the internal carotid artery (ICA). METHODS: Forty-four patients with 52 known or suspected stenoses of the internal carotid artery (ICA) were included in this prospective study. High-resolution MRA scans with a spatial resolution of 0.9 mm x 0.7 mm x 0.9 mm were acquired with an iPAT acceleration factor of 2 on a 1.5T MR system (Sonata Maestro Class, Siemens Medical Solutions, Erlangen, Germany) with a head, neck and body coil. For the 3D-CE MRA a fast spoiled gradient echo sequence (FLASH) was used. To compensate for the inherent signal loss with parallel imaging, a 1M contrast agent (gadobutrol, Gadovist, Schering, Berlin, Germany) was used. Stenoses were quantified by two readers in consensus in cross-sectional area measurements and graded according to the NASCET criteria. Using color coded duplex ultrasound (CCDS) and power Doppler (PD; Logiq 9, GE), the stenoses were also graded by two readers in consensus according to the NASCET criteria from intra- and post-stenotic diameter measurements. The results of MRA, CCDS and PD were compared to intraoperative findings or to follow-up examinations. RESULTS: High-resolution MRA allowed an excellent grading of vascular stenoses. In 70-90% degrees of stenosis there was an underestimation of the degree of stenosis in MRA as well as in CCDS. However, there was an overestimation of 90% stenoses in both MRA and CCDS. Pseudoocclusions with a lumen of less than one millimeter were occasionally rated as a complete occlusion in MRA. CONCLUSION: A combination of MRA and duplex sonography seems reasonable for the accurate grading of stenoses and determination of distal stenoses downstream. However, the accuracy of duplex ultrasound depends on the examiner's experience.


Assuntos
Artéria Carótida Interna , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/diagnóstico , Imageamento Tridimensional , Angiografia por Ressonância Magnética/métodos , Ultrassonografia Doppler Dupla , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Prospectivos , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia Doppler em Cores
7.
Radiologe ; 46(7): 596-603, 2006 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-16151727

RESUMO

Percutaneous catheter interventions are performed increasingly often for the purposes of both diagnosis and therapy. The incidence of local complications reported after transfemoral catheterization in the literature is 0.1-9%. Such complications should be detected as early and reliably as possible, and sonography is a good means of finding them during follow-up, not least because it is suitable for use in examinations at the bedside. The clinical value of sonography compared with other examination techniques is made clear with reference to specimen cases.


Assuntos
Cateterismo Periférico/estatística & dados numéricos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/lesões , Punções/estatística & dados numéricos , Ultrassonografia/estatística & dados numéricos , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/epidemiologia , Humanos , Incidência , Padrões de Prática Médica/estatística & dados numéricos , Medição de Risco/métodos , Fatores de Risco , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...