Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Prenat Diagn ; 21(7): 571-4, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11494294

RESUMO

In 45 cases of trisomy 18 and 493 control pregnancies at 10-14 weeks of gestation, maternal serum inhibin A, total activin A, free beta-hCG and PAPP-A were measured. In the trisomy 18 pregnancies the median values were 0.74 MoM for inhibin A, 1.23 MoM for activin A, 0.38 MoM for free beta-hCG and 0.16 MoM for PAPP-A. The degree of deviation from normal in the levels of inhibin and activin is small in comparison with free beta-hCG and PAPP-A and they are therefore unlikely to be of value in improving the sensitivity of 90% for a 1% false-positive rate achieved by screening with fetal nuchal translucency and maternal serum free beta-hCG and PAPP-A.


Assuntos
Cromossomos Humanos Par 18 , Inibinas/sangue , Diagnóstico Pré-Natal/normas , Trissomia/diagnóstico , Ativinas , Adulto , Estudos de Casos e Controles , Gonadotropina Coriônica Humana Subunidade beta/sangue , Feminino , Idade Gestacional , Humanos , Valor Preditivo dos Testes , Gravidez , Primeiro Trimestre da Gravidez , Proteína Plasmática A Associada à Gravidez/metabolismo , Sensibilidade e Especificidade
2.
Am J Obstet Gynecol ; 173(6): 1788-92, 1995 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8610763

RESUMO

OBJECTIVE: Our purpose was to examine the potential of color flow imaging to assess the presence of renal arteries in second-trimester pregnancies complicated by severe oligohydramnios. STUDY DESIGN: Thirty-three consecutive second-trimester pregnancies referred with severe oligohydramnios were prospectively studied with high-resolution color Doppler ultrasonography to establish the presence or absence of renal arteries. Prenatal findings were correlated with the presence or absence of fetal kidneys at postmortem or postnatal examination. RESULTS: Neither renal artery was visualized in eight fetuses; postmortem examination confirmed bilateral renal agenesis in seven and unilateral renal agenesis with a contralateral atrophic multicystic kidney in the other. Only one renal artery was seen in three; postmortem examination demonstrated unilateral renal agenesis in two fetuses and bilateral multicystic dysplastic kidneys in the other. Postmortem or postnatal evaluation confirmed the presence of both kidneys in all 22 fetuses in which both renal arteries were identified prenatally. CONCLUSIONS: Color Doppler ultrasonography is useful in the prenatal evaluation of fetuses with severe second-trimester oligohydramnios to demonstrate the presence or absence of renal arteries. This technique should be added to the armamentarium of prenatal tests to evaluate second-trimester fetuses with severe oligohydramnios.


Assuntos
Doenças Fetais/diagnóstico por imagem , Rim/anormalidades , Oligo-Hidrâmnio , Ultrassonografia Doppler em Cores , Feminino , Humanos , Rim/diagnóstico por imagem , Gravidez , Segundo Trimestre da Gravidez , Estudos Prospectivos , Artéria Renal/diagnóstico por imagem
3.
Am J Obstet Gynecol ; 173(4): 1186-91, 1995 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-7485317

RESUMO

OBJECTIVE: Our purpose was to determine whether acute maternal hydration in pregnancies with third-trimester oligohydramnios (1) increases amniotic fluid index and hourly fetal urine production rate and (2) alters uteroplacental perfusion and fetal blood flow. STUDY DESIGN: Ten women with third-trimester oligohydramnios (amniotic fluid index < or = 5 cm) and 10 controls with normal amniotic fluid volume (amniotic fluid index > 7 cm) were prospectively recruited for this study. Maternal plasma and urine osmolality, amniotic fluid index, hourly fetal urine production rate, and Doppler flow velocimetry of maternal uterine artery and fetal umbilical, descending aorta, middle cerebral, and renal arteries were determined before and after oral hydration by having the patient drink 2 L of water over 2 hours. RESULTS: There was a significant reduction in maternal plasma (p < 0.05) and urine osmolality (p < 0.0001) in both groups after short-term oral hydration. Hydration increased amniotic fluid volume in women with oligohydramnios (mean change in amniotic fluid index 3.2 cm, 95% confidence intervals 1.1 to 5.3; p < 0.02) but not in those with normal amniotic fluid volume (mean change in amniotic fluid index -2.0, 95% confidence intervals -4.1 to +0.2). The hourly fetal urine production rate, however, did not increase in either group (mean change in hourly fetal urine production rate 3.5 ml/hr, 95% confidence intervals -11.7 to +18.7 and -6.8 ml/hr, 95% confidence intervals -2.9 to -10.7, respectively). Hydration was associated with an increase in uterine artery mean velocity in the oligohydramnios group (mean change in mean velocity 16.7 cm/sec, 95% confidence intervals 8.0 to 25.3; p < 0.006) but not in controls (mean change in mean velocity 1.2 cm/sec, 95% confidence intervals -19.7 to +22.1). There was no change in pulsatility index or in velocity in any of the fetal vessels studied in either group. CONCLUSIONS: Short-term maternal oral hydration increases the amniotic fluid index in women with third-trimester oligohydramnios. Although the mechanism for this effect remains unclear, it could not be accounted for by fetal urination in this study but instead was associated with improved uteroplacental perfusion.


Assuntos
Líquido Amniótico/metabolismo , Feto/irrigação sanguínea , Hidratação , Oligo-Hidrâmnio/terapia , Placenta/irrigação sanguínea , Micção , Útero/irrigação sanguínea , Velocidade do Fluxo Sanguíneo , Feminino , Feto/fisiopatologia , Humanos , Oligo-Hidrâmnio/sangue , Oligo-Hidrâmnio/urina , Concentração Osmolar , Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Fluxo Sanguíneo Regional , Reologia
4.
Am J Obstet Gynecol ; 173(2): 502-7, 1995 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-7645627

RESUMO

OBJECTIVE: Our purpose was to investigate whether acute alterations of amniotic fluid volume affect uteroplacental perfusion. STUDY DESIGN: Three groups of patients of comparable gestational age were studied in a fetal medicine referral unit: (1) eight pregnancies with severe polyhydramnios because of twin-twin transfusion syndrome undergoing therapeutic amnioreduction, (2) seven with severe oligohydramnios undergoing diagnostic amnioinfusion, and (3) six control women having invasive procedures of similar duration without manipulation of amniotic fluid volume. Color Doppler imaging was used to measure uterine artery impedance index values and quantitative blood flow before and within 15 minutes of the end of the procedure. RESULTS: Quantitative flow measurements increased after amnioreduction (74% median increase of volume flow, range 22% to 329%, p < 0.01) and decreased after amnioinfusion (33% median decrease of volume flow, range 17% to 51%, p < 0.05). Impedance index values increased after amnioinfusion (25% median increase in pulsatility index, range 4% to 71%, p < 0.05) and did not alter with amnioreduction. There were no significant changes in the control group. CONCLUSION: Acute changes in amniotic fluid volume alter uteroplacental perfusion. In twin-twin transfusion syndrome amelioration in uterine flow may improve fetal condition and explain in part the success of serial amnioreduction therapy.


Assuntos
Líquido Amniótico/fisiologia , Útero/irrigação sanguínea , Artérias/fisiopatologia , Velocidade do Fluxo Sanguíneo , Volume Sanguíneo , Feminino , Transfusão Feto-Fetal/fisiopatologia , Transfusão Feto-Fetal/terapia , Humanos , Oligo-Hidrâmnio/fisiopatologia , Oligo-Hidrâmnio/terapia , Circulação Placentária , Poli-Hidrâmnios/fisiopatologia , Poli-Hidrâmnios/terapia , Gravidez , Pulso Arterial , Resistência Vascular
6.
Am J Obstet Gynecol ; 171(2): 521-5, 1994 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8059834

RESUMO

OBJECTIVE: The aim of this study was to investigate pelvic and femoral arterial flow velocity waveforms in fetuses with a single umbilical artery. STUDY DESIGN: Seven fetuses with single umbilical artery and no other ultrasonographically detected anomalies were studied with color Doppler ultrasonography at a median gestational age of 24 weeks (range 18 to 34 weeks). Flow velocity waveforms from the relevant vessels were obtained as follows: (1) umbilical artery from a free loop of cord, (2) common iliac artery from both sides just below the aortic bifurcation, (3) internal iliac artery and intraabdominal portion of the umbilical artery from the vessel visualized alongside the fetal bladder, and (4) femoral artery on both sides from the upper third of the fetal thigh. The pulsatility index was measured, and comparisons were made with the paired t test. A p value < 0.05 was considered significant. RESULTS: The pulsatility index in the umbilical artery was normal in all cases. There were highly significant differences between the common iliac arteries in each side (difference in pulsatility index 2.7, 95% confidence interval 2.0 to 3.5, p < 0.001). Significant differences between both femoral arteries were also noted (difference in pulsatility index 1.0, 95% confidence interval 0.3 to 1.7, p < 0.001). In both vessels the pulsatility index was always higher in the side that did not participate in the placental circuit. CONCLUSION: This study demonstrates that fetuses with single umbilical artery have asymmetric arterial blood flow patterns in the pelvic and lower extremities.


Assuntos
Artéria Femoral/fisiologia , Feto/fisiologia , Artéria Ilíaca/fisiologia , Fluxo Pulsátil/fisiologia , Ultrassonografia Pré-Natal , Artérias Umbilicais/anormalidades , Velocidade do Fluxo Sanguíneo , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Artéria Ilíaca/diagnóstico por imagem , Gravidez
7.
Am J Obstet Gynecol ; 171(1): 218-22, 1994 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8030702

RESUMO

OBJECTIVE: Our purpose was to study the effect of operator transducer pressure on amniotic fluid index and single deepest pool measurements and their intraobserver and interobserver variability. STUDY DESIGN: Forty subjects in the third trimester with intact membranes were studied by two observers at three predetermined operator pressures. Pressure was measured by interfacing a flexible water-filled reservoir connected to a manometer between the maternal abdomen and the ultrasonography transducer. The amniotic fluid index and single deepest pool were measured on screen by another operator, and data were analyzed by calculating components of variance. RESULTS: Compared with medium pressure, low pressure resulted in a 13% increase in amniotic fluid index (p < 0.001), and high pressure resulted in a 21% fall in amniotic fluid index (p < 0.001). The single deepest pool was less sensitive to pressure, with a 11% increase at low pressure (p < 0.001) and a 16% fall at high pressure (p < 0.001). Intraobserver error was 17% for amniotic fluid index and 18% for single deepest pool when operator pressure was controlled at medium pressure; this increased to 28% and 24%, respectively, when pressure was not controlled (p < 0.01). Interobserver error was consistently very low. CONCLUSION: Both techniques are highly sensitive to the pressure applied to the maternal abdomen during scanning. The reproducibility of amniotic fluid index and single deepest pool is comparable. The use of the same observer for serial measurements of amniotic fluid index would appear to be less important than careful attention to transducer pressure.


Assuntos
Líquido Amniótico/diagnóstico por imagem , Ultrassonografia Pré-Natal/estatística & dados numéricos , Análise de Variância , Feminino , Humanos , Variações Dependentes do Observador , Gravidez , Terceiro Trimestre da Gravidez , Pressão , Reprodutibilidade dos Testes , Ultrassonografia Pré-Natal/instrumentação , Ultrassonografia Pré-Natal/métodos
8.
Am J Obstet Gynecol ; 170(4): 1160-3, 1994 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8166203

RESUMO

OBJECTIVE: Our purpose was to investigate the relationship between amniotic fluid volume and semiquantitative ultrasonographic assessment of amniotic fluid in the midtrimester. STUDY DESIGN: Sixteen pregnancies between 16 and 28 weeks with minimal amniotic fluid (severe oligohydramnios or anhydramnios) and intact membranes were studied at the time of clinically indicated amnioinfusion. The amniotic fluid index and deepest pool measurement were determined before and immediately after the procedure. Correlations were sought by means of standard regression techniques with amniotic fluid volume (i.e., volume infused) on the basis of the assumption that amniotic fluid volume before amnioinfusion was effectively nil. RESULTS: There was a significant linear relationship between amniotic fluid index and volume infused (y = 7.336 + 0.015x; R2 = 0.30, p < 0.05). However, no correlation with the deepest pool measurement technique was found (R2 = 0.11, p > 0.05). CONCLUSION: Amniotic fluid index is preferable to deepest pool measurement in assessing amniotic fluid volume in the second trimester of pregnancy. The low variance (30%) suggests that better predictors of amniotic fluid volume are still required.


Assuntos
Líquido Amniótico/diagnóstico por imagem , Ultrassonografia Pré-Natal , Feminino , Idade Gestacional , Humanos , Gravidez , Segundo Trimestre da Gravidez
9.
Ultrasound Obstet Gynecol ; 4(2): 143-6, 1994 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-12797209

RESUMO

The prenatal diagnosis of hypoplastic umbilical artery has recently been reported, based on the visualization of discordant size between both umbilical arteries in association with discordant umbilical artery flow velocity waveforms. In this report we present two cases of hypoplastic umbilical artery and describe the use of color flow imaging and Doppler ultrasound in the prenatal evaluation of this condition. The principal advantages of these techniques include the confirmation of blood flow within the hypoplastic artery, thus ruling out the possibility of an atrophic non-functional artery, and the demonstration of size discrepancy at the level of the intra-abdominal portion of the umbilical arteries, validating the intra-amniotic cord findings. Color Doppler ultrasound is an important tool for diagnosing and evaluating vascular anomalies affecting the umbilical cord.

10.
Obstet Gynecol ; 82(4 Pt 2 Suppl): 714-6, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8378024

RESUMO

BACKGROUND: We describe the concurrent administration of amiodarone using three different routes in order to provide: 1) rapid and adequate fetal loading without giving unduly high doses to the mother, and 2) a maintenance dose to the fetus without risking repeated invasive procedures. CASE: Rapid atrial flutter was seen on ultrasound in a fetus with severe hydrops at 27 weeks' gestation. Following failed transplacental therapy with sotalol and flecainide, amiodarone was administered to the fetus via the intravenous, intraperitoneal, and transplacental routes. Conversion to sinus rhythm and resolution of hydrops followed this treatment. CONCLUSION: Combined triple-route administration of amiodarone to the fetus can be effective in treating supraventricular tachycardia and may have a role in the management of life-threatening fetal arrhythmias refractory to transplacental therapy.


Assuntos
Amiodarona/administração & dosagem , Flutter Atrial/tratamento farmacológico , Edema/tratamento farmacológico , Adulto , Amiodarona/uso terapêutico , Flutter Atrial/complicações , Vias de Administração de Medicamentos , Edema/complicações , Feminino , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...