Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Inhal Toxicol ; 21(6): 488-96, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19259884

RESUMO

We developed and validated an ion chromatography method to assay iodide in serum sampled from rats and rabbits that had been exposed to iodomethane. Iodomethane is of interest because it is a volatile liquid pre-plant soil crop protection fumigant that has been proposed as a non-ozone-depleting alternative to methyl bromide. Serum was prepared from whole blood collected on wet ice at the time of sacrifice and kept frozen at less than -65 degrees C. For analysis, serum samples were thawed unassisted at ambient temperature. Proteins were separated from the serum samples by ultrafiltration. A 100-microl filtered serum sample was then injected into the ion chromatograph without additional sample preparation. Iodide was separated in <20 min by anion-exchange chromatography using a 25-mM nitric acid eluent. The analyte of interest was detected by pulsed amperometry using a silver working electrode. The method showed linear response over the concentration range of 100 to 5000 ng/ml iodide (r2>.998) with a lower limit of quantitation of 100 ng/ml iodide. The accuracy of the procedure, determined by spiked recovery measurements at 100 ng/ml iodide, was between 90 and 110%. A method detection limit of 20 ng/ml for iodide in serum samples was demonstrated using the method of standard additions.


Assuntos
Iodetos/sangue , Animais , Cromatografia por Troca Iônica/instrumentação , Cromatografia por Troca Iônica/métodos , Cromatografia por Troca Iônica/normas , Eletroquímica/instrumentação , Eletroquímica/métodos , Eletroquímica/normas , Hidrocarbonetos Iodados/análise , Hidrocarbonetos Iodados/sangue , Iodetos/análise , Masculino , Coelhos , Ratos , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas por Ionização por Electrospray/normas
2.
J Chromatogr A ; 1123(1): 10-4, 2006 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-16814306

RESUMO

The determination of perfluorooctanoate (PFO) in articles of commerce has become increasingly important to understand if treated products are a possible source of PFO. An LC-MS/MS method for the determination of PFO in paper and textile using a dual labeled 13C-PFOA internal standard was successfully developed and validated. Residues of PFO were determined using an isocratic, reversed-phase high-performance liquid chromatography (HPLC) method with an ammonium acetate/methanol buffer. Ions monitored were 413 (parent) and 369 (daughter) for PFO and 415 (parent) and 370 (daughter) for dual labeled 13C-PFOA internal standard. As a precaution against ubiquitous PFO that occasionally occurs in mobile phase or instrument components, two Hypercarb cartridges (4 mm) were placed before the HPLC injector. Any PFO that was captured by the cartridges was removed before each injection by flushing the system with 100% methanol prior to equilibration with the isocratic mobile phase. Overall recovery and standard deviation over a 3 day validation regimen for samples (n=54-55) fortified with PFOA at 5, 50, and 200 ng g(-1) were 114+/-4.9% for textile and 110+/-7.6% for paper. The results also established a limit of detection (LOD) of 1 ng g(-1) in textile and 2 ng g(-1) in paper based upon S/N of the 5.0 ng g(-1) fortification versus the untreated paper and textile.


Assuntos
Caprilatos/análise , Cromatografia Líquida de Alta Pressão/métodos , Fluorocarbonos/análise , Espectrometria de Massas/métodos , Papel , Têxteis/análise , Padrões de Referência , Sensibilidade e Especificidade
3.
Artigo em Inglês | MEDLINE | ID: mdl-15833298

RESUMO

A selective and sensitive method for analysis of perfluorooctanoic acid (PFOA) in human serum and plasma, utilizing liquid chromatography tandem mass spectrometry (LC-MS/MS), has been developed and thoroughly validated to satisfy strict FDA guidelines for bioanalytical methods. A simple, automated sample preparation procedure, involving extraction of the target analyte with acetonitrile on protein precipitation media in a 96-well plate format was developed, allowing efficient handling of large numbers of samples. The proposed method uses the calibration standards prepared in a surrogate matrix (rabbit serum or plasma) and (13)C-labeled PFOA as the internal standard to account for matrix effects, instrument drift, and extraction efficiency. Human serum and plasma could not be used for matrix matching of calibration standards as endogenous levels of PFOA observed in the control human serum and plasma significantly exceeded the targeted lower limit of quantitation (LLOQ) of the method. Precision and accuracy of the method were demonstrated by analysis of rabbit serum and plasma control samples fortified at 0.5, 5, and 40 ng/mL PFOA and human serum and plasma fortified at 1.0, 5.0, 40 ng/mL PFOA. The LLOQ of 0.5 ng/mL PFOA was experimentally demonstrated for rabbit and human serum and plasma. Within-day precision and accuracy, short-term stability, freeze-thaw stability, equivalence of response between PFOA and APFO (the ammonium salt of PFOA), and dilution of concentrated samples were also investigated. The results of the validation experiments comply with the precision and accuracy limits defined by the FDA guidance document: "Guidance for Industry, Bioanalytical Method Validation", May 2001.


Assuntos
Caprilatos/sangue , Cromatografia Líquida/métodos , Fluorocarbonos/sangue , Espectrometria de Massas/métodos , Animais , Coelhos , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Occup Environ Hyg ; 1(9): 559-69, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15559328

RESUMO

The widespread use of semi- and nonvolatile organofluorochemicals in industrial facilities, concern about their persistence, and relatively recent advancements in liquid chromatography/mass spectrometry (LC/MS) technology have led to the development of new analytical methods to assess potential worker exposure to airborne organofluorochemicals. Techniques were evaluated for the determination of 19 organofluorochemicals and for total fluorine in ambient air samples. Due to the potential biphasic nature of most of these fluorochemicals when airborne, Occupational Safety and Health Administration (OSHA) versatile sampler (OVS) tubes were used to simultaneously trap fluorochemical particulates and vapors from workplace air. Analytical methods were developed for OVS air samples to quantitatively analyze for total fluorine using oxygen bomb combustion/ion selective electrode and for 17 organofluorochemicals using LC/MS and gas chromatography/mass spectrometry (GC/MS). The experimental design for this validation was based on the National Institute of Occupational Safety and Health (NIOSH) Guidelines for Air Sampling and Analytical Method Development and Evaluation, with some revisions of the experimental design. The study design incorporated experiments to determine analytical recovery and stability, sampler capacity, the effect of some environmental parameters on recoveries, storage stability, limits of detection, precision, and accuracy. Fluorochemical mixtures were spiked onto each OVS tube over a range of 0.06-6 microg for each of 12 compounds analyzed by LC/MS and 0.3-30 microg for 5 compounds analyzed by GC/MS. These ranges allowed reliable quantitation at 0.001-0.1 mg/m3 in general for LC/MS analytes and 0.005-0.5 mg/m3 for GC/MS analytes when 60 L of air are sampled. The organofluorochemical exposure guideline (EG) is currently 0.1 mg/m3 for many analytes, with one exception being ammonium perfluorooctanoate (EG is 0.01 mg/m3). Total fluorine results may be used to determine if the individual compounds quantified provide a suitable mass balance of total airborne organofluorochemicals based on known fluorine content. Improvements in precision and/or recovery as well as some additional testing would be needed to meet all NIOSH validation criteria. This study provided valuable information about the accuracy of this method for organofluorochemical exposure assessment.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental/métodos , Fluorocarbonos/análise , Exposição Ocupacional , Cromatografia Líquida , Cromatografia Gasosa-Espectrometria de Massas , National Institute for Occupational Safety and Health, U.S. , Estados Unidos , Volatilização
5.
Environ Sci Technol ; 37(1): 107-15, 2003 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-12542298

RESUMO

Total cyanide analysis by distillation is used most commonly to assess cyanide content of water samples. This manual method is robust but slow and provides no information about cyanide speciation, a significant limitation in that cyanide species have substantially different toxicity characteristics. Seven alternative methods for the analysis of cyanide species or groups of species were evaluated in reagent water and five different contaminated water matrices, including five species-specific methods--weak acid dissociable (WAD) cyanide, free cyanide by microdiffusion, available cyanide, automated WAD cyanide by thin film distillation, metal cyanides by ion chromatography--and two automated techniques for total cyanide--total cyanide bythin film distillation and total cyanide by low-power UV digestion. The species-specific cyanide analytical techniques achieved low, ppb-level detection limits and exhibited satisfactory accuracy and precision for most contaminated waters. Analysis of low concentrations of cyanide species in raw wastewater was problematical for the available cyanide and ion chromatography methods, which experienced significant interference problems and/or low recoveries. There was recovery of significant diffusible cyanide in microdiffusion tests with nickel-cyanide-spiked samples, reflecting dissociation of this weak metal-cyanide complex during the test and demonstrating that the test can recover some fraction of WAD cyanide in addition to free cyanide. The automated total cyanide methods, which involve UV digestion, achieved low detection limits for most waters but exhibited low recoveries for some waters.


Assuntos
Cianetos/análise , Cianetos/química , Monitoramento Ambiental/métodos , Resíduos Industriais , Poluentes da Água/análise , Cromatografia por Troca Iônica , Difusão , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...