Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Res Pract Thromb Haemost ; 8(4): 102422, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38840662

RESUMO

Background: To overcome deficiencies of the traditional von Willebrand factor (VWF) ristocetin cofactor activity assay (VWF:RCo), several automated assays for VWF platelet-binding activity have been developed. Information on the performance of these assays and their diagnostic utility remains limited. Objectives: To validate the VWF:glycoprotein IbM assay INNOVANCE VWF Ac and compare it with an automated VWF:RCo assay as well as with an automated assay and a manual VWF:Ab assay and to generate reference ranges and analyze reproducibility of the VWF:glycoprotein IbM assay. Methods: Clinical sites enrolled healthy subjects and patients representing the intended use population; VWF activity assays were performed, and results were analyzed. The performance of the INNOVANCE VWF Ac assay was also compared between the BCS XP System and the CS-2500 and CS-5100 analyzers. Results: The INNOVANCE VWF Ac assay correlated well with the VWF:RCo assay and the automated HemosIL VWF:Ab assay, with Pearson coefficients of >.9 and a predicted bias of ≤5.0 IU/dL at VWF levels of 30 IU/dL and ≤5.8 IU/dL at the levels of 50 IU/dL, but correlation and bias were not as good when compared with the REAADS manual VWF:Ab assay. Reference ranges observed for healthy subjects correlated well with previously published findings. Reproducibility of the INNOVANCE VWF Ac assay on the BCS XP System and the CS analyzers was excellent, as was correlation among devices. Conclusion: The characteristics of the INNOVANCE VWF Ac assay regarding comparability with other VWF activity assays, reference ranges, and precision support the use of this assay for evaluation of patients with concern for von Willebrand disease.

2.
Immunohematology ; 38(4): 142, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36789460
3.
Blood Adv ; 5(3): 737-744, 2021 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-33560383

RESUMO

Chronically transfused patients with thalassemia are at risk for red cell alloimmunization. No studies have specifically examined alloimmunization after implementation of prophylactic Rh (D, C, E) and K matched red cells in a racially diverse population of thalassemia patients and donors. This retrospective study examined Rh antibodies among 40 chronically transfused patients (Asian, White, Black, Indian, Middle Eastern) with thalassemia receiving a mean of 174 serologic prophylactic RhD, C, E, and K matched red cell units. We examined the patients' RH genotype, as well as donor race and Rh phenotypes over 3 transfusion events preceding antibody detection. Eighteen alloantibodies were detected in 13 of 40 patients (32.5%), with an alloimmunization rate of 0.26 antibodies per 100 units transfused. Thirteen antibodies (72.2%) were directed against Rh (5 anti-D, 4 anti-C, 2 anti-E, 1 anti-e, 1 anti-V), despite donor phenotypes that confirmed lack of transfusion of D, C, or E antigens to patients lacking the corresponding antigen(s). Ten of 40 patients had an altered RH genotype, but the Rh antibodies were not associated with patients with variant RH. Black donors with a known high frequency of RH variants provided 63% of the units transfused in the 3 visits preceding unexplained anti-Rh detection. Rh alloimmunization not explained by the thalassemia patients' RH genotype or the donors' serologic phenotype suggests more precise matching is needed, and the role of donor RH genotypes on alloimmunization should be explored. Extending Rh D, C, and E matching to include c and e would result in better-matched units and further minimize Rh alloimmunization.


Assuntos
Antígenos de Grupos Sanguíneos , Talassemia , Transfusão de Sangue , Eritrócitos , Humanos , Estudos Retrospectivos , Talassemia/terapia
6.
Transfus Med Hemother ; 41(5): 342-5, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25538535

RESUMO

The American Rare Donor Program (ARDP) was formed in 1998 to provide rare blood units for patients in need. Members of the program identify rare donors and submit donor information for entrance into a database, REGGI. Information on patients in need of rare blood is also submitted and entered into REGGI. REGGI serves to match phenotypes of registered donors with patients having the respective antibodies. A search process for available units ensues, and blood is provided to the patient. This report provides information on REGGI and its use in the ARDP.

7.
J Crit Care ; 28(1): 110.e9-110.e18, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22520495

RESUMO

The American Rare Donor Program (ARDP), headquartered in Philadelphia, Pennsylvania, maintains a comprehensive database of donors with "rare blood types." The ARDP secures blood and blood products for difficult-to-transfuse patients. Remarkably, a significant number of physicians, both in the United States and abroad, remain unaware of the unique and critical services that the ARDP provides to critical care specialists and their patients.


Assuntos
Bancos de Sangue , Antígenos de Grupos Sanguíneos , Incompatibilidade de Grupos Sanguíneos/prevenção & controle , Transfusão de Sangue , Bases de Dados Factuais , Bancos de Sangue/organização & administração , Doadores de Sangue/provisão & distribuição , Humanos , Deficiência de IgA , Sistema de Registros , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...