Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Comp Med ; 72(4): 243-247, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35803708

RESUMO

This report describes an anesthesia technique that we used to study cardiovascular anatomy and physiology with echocardiography and cardiac magnetic resonance (CMR) in 46 African clawed frogs (Xenopus laevis) (n = 24 for electrocardiography and n = 22 for CMR). For administration of anesthesia, 3 holding tanks, one each for transportation, sedation, and recovery, were filled with filtered water, with 0.05% buffered tricaine methasulfonate solution (MS-222) added into the sedation tank. Fifteen minutes after the frog was placed in the sedation tank, a paper towel was soaked in MS-222 solution, and the frog was placed in a supine position and rolled 3 to 4 times in the soaked paper with the head and legs exposed. Vital signs were monitored and recorded throughout the procedure. After imagining, frogs were unrolled from the paper towel, placed in the recovery tank, and later returned to their home tank. Monitoring was discontinued when the frogs resumed typical activity. No mortality or complications were observed in frogs that underwent this procedure. Mean duration ±1 SD of anesthesia induction was 12 ± 5 min in the echocardiography group and 14 ± 6 min in the CMR group. The mean duration of anesthesia maintenance was 60 ± 18 min in the echocardiography group and 118 ± 37 min in the CMR group. An additional dose of anesthesia was necessary during maintenance for 9 of 24 (37%) frogs in the echocardiography group and 6 of 22 (27%) frogs in the CMR group. At the end of the procedure, the mean oxygen saturation was 66 ± 9% in the echocardiography group and 85 ± 6% in the CMR group, and heart rate was 48 ± 13 beats/min in the echocardiography group and 42 ± 7 beats/min in the CMR group. We conclude that the anesthesia technique of immersion in MS-222 is suitable for performing echocardiography and CMR imaging in this species without complications.


Assuntos
Anestesia Geral , Imageamento por Ressonância Magnética , Animais , Ecocardiografia , Frequência Cardíaca , Xenopus laevis
2.
Arch Psychiatr Nurs ; 25(5): e9-17, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21978811

RESUMO

In agreement with the new paradigm of supports, this study examines the adequacy and psychometric properties of the Supports Intensity Scale (SIS) in a sample of 182 participants with severe mental illness (mean Global Assessment of Functioning [GAF] score = 60.2). The measure focuses on identifying the profile and intensities of support needs and on the planning and service delivery rather than on weaknesses and limitations. Internal consistency indexes ranged from .83 to .97; interrater reliability indexes ranged from .67 to .98. Intercorrelations among SIS subscales supported its construct validity. SIS scores correlated to GAF scores and length of disease. Discriminant analysis correctly classified 60.9% of participants. Therefore, the SIS demonstrated adequate reliability and validity, and it can be used by nursing professionals to plan for required supports in this population.


Assuntos
Transtornos Mentais/diagnóstico , Transtornos Mentais/terapia , Pessoas Mentalmente Doentes/psicologia , Psicometria/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cuidadores/psicologia , Atenção à Saúde , Avaliação da Deficiência , Feminino , Humanos , Masculino , México , Pessoa de Meia-Idade , Avaliação das Necessidades , Inquéritos e Questionários , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...