Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(8)2022 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-35459069

RESUMO

A water supply system is considered an essential service to the population as it is about providing an essential good for life. This system typically consists of several sensors, transducers, pumps, etc., and some of these elements have high costs and/or complex installation. The indirect measurement of a quantity can be used to obtain a desired variable, dispensing with the use of a specific sensor in the plant. Among the contributions of this technique is the design of the pressure controller using the adaptive control, as well as the use of an artificial neural network for the construction of nonlinear models using inherent system parameters such as pressure, engine rotation frequency and control valve angle, with the purpose of estimating the flow. Among the various contributions of the research, we can highlight the suppression in the acquisition of physical flow meters, the elimination of physical installation and others. The validation was carried out through tests in an experimental bench located in the Laboratory of Energy and Hydraulic Efficiency in Sanitation of the Federal University of Paraiba. The results of the soft sensor were compared with those of an electromagnetic flux sensor, obtaining a maximum error of 10%.


Assuntos
Redes Neurais de Computação , Água , Dinâmica não Linear , Transdutores , Abastecimento de Água
2.
Sensors (Basel) ; 21(15)2021 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-34372393

RESUMO

Water supply systems are constantly improving their operation through energy efficiency actions that involve the use of advanced measurement, control, and automation techniques. The maintenance and reliability of water distribution is directly associated with hydraulic pressure control. The main challenges encountered in hydraulic pressure control are associated with random changes in the supply plant and the presence of noise and outliers in the sensor measurements. These undesired characteristics cause inefficiency and instability in the control system of the pumping stations. In this scenario, this paper proposes an indirect adaptive control methodology by reference model for modeling and controlling water supply systems. The criterion adopted in the parametric estimation mechanism and the controller adaptation is the Maximum Correntropy. Experimental results obtained with an experimental bench plant showed that the maximum tracking error was 15% during demand variation, percentage overshoot less than 5%, and steady-state error less than 2%, and the control system became robust to noise and outliers. In comparison to the Mean Squared Error criterion, when noise and outliers influence the sensor signal, the proposed methodology stands out, reducing the mean error and the standard deviation, in the worst-case scenario, by more than 1500%. The proposed methodology, therefore, allows for increased reliability and efficiency of an advanced pump control system, avoiding downtime and equipment damage.


Assuntos
Reprodutibilidade dos Testes
3.
Sensors (Basel) ; 21(1)2020 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-33375561

RESUMO

Indirect measurement can be used as an alternative to obtain a desired quantity, whose physical positioning or use of a direct sensor in the plant is expensive or not possible. This procedure can been improved by means of feedback control strategies of a secondary variable, which can be measured and controlled. Its main advantage is a new form of dynamic response, with improvements in the response time of the measurement of the quantity of interest. In water pumping networks, this methodology can be employed for measuring the flow indirectly, which can be advantageous due to the high price of flow sensors and the operational complexity to install them in pipelines. In this work, we present the use of artificial intelligence techniques in the implementation of the feedback system for indirect flow measurement. Among the contributions of this new technique is the design of the pressure controller using the Fuzzy logic theory, which rules out the need for knowing the plant model, as well as the use of an artificial neural network for the construction of nonlinear models with the purpose of indirectly estimating the flow. The validation of the proposed approach was carried out through experimental tests in a water pumping system, fully automated and installed at the Laboratory of Hydraulic and Energy Efficiency in Sanitation at the Federal University of Paraiba (LENHS/UFPB). The results were compared with an electromagnetic flow sensor present in the system, obtaining a maximum relative error of 10%.

SELEÇÃO DE REFERÊNCIAS