Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
J Prosthodont ; 32(5): 445-451, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35942518

RESUMO

PURPOSE: To analyze the in vitro efficacy of a surface conditioning liquid facilitating ceramic repairs of saliva-contaminated metal-ceramic and all-ceramic restorations. MATERIALS AND METHODS: Specimens constructed from nonprecious alloy (NPA), precious alloy (PA), lithium-disilicate (LD), zirconia (ZI), veneering ceramics for zirconia (VZI), veneering ceramics for lithium-disilicate (VLD), and veneering ceramics for metal alloys (VM) were manufactured (total: n = 168; each material n = 24). Veneering ceramic cylinders (thickness: 2 mm) were hand-layered on top of the specimens. Shear bond strength (SBS) tests were performed, measuring the maximum bond strength (MBS) of the cylinders on the specimens. Following this, the specimens were artificially aged and stored in artificial saliva for 30 days at 37°C. After physical cleaning using aluminum oxide air abrasion, a new surface conditioning liquid was applied (test, n = 84) or not (control, n = 84). New ceramic cylinders were hand-layered followed by a second SBS test. Descriptive statistics, linear regression analyses, and a one-sample t-test (α = 0.05) were used to ascertain the differences within (prerepair vs. postrepair) and between the groups. RESULTS: All specimens in the test group could be repaired, whereas 18 repairs in the control group failed. After the repairs, an MBS decrease was observed for the NPA specimens of the control group (-15.5 MPa, p = 0.004) but not among any of the test groups. Comparing the change in MBS between the test and control groups, the reduction was significantly higher in the repaired NPA specimens of the control group (mean difference 11.8 MPa, p = 0.017). CONCLUSIONS: Using the analyzed surface conditioning liquid, metal-ceramic and all-ceramic materials can be repaired, while some repairs failed without the liquid. The initial bond strengths between core and veneering materials could be restored in all specimens when the new surface conditioning liquid was applied.


Assuntos
Colagem Dentária , Saliva , Abrasão Dental por Ar , Lítio , Propriedades de Superfície , Porcelana Dentária/química , Cerâmica/química , Zircônio/química , Ligas , Teste de Materiais , Resistência ao Cisalhamento , Facetas Dentárias , Análise do Estresse Dentário
2.
Swiss Dent J ; 131(12): 988-997, 2021 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-33764037

RESUMO

The objective was to systematically analyse clinical studies on restorative procedures for teeth affected by molar-incisor hypomineralisation (MIH). The databases PubMed, Embase, and Cochrane Library were searched. Only retrospective and prospective clinical studies dealing with sealing or restoration of MIH-affected teeth were included. The language was restricted to English or German. Thirteen of 36 potentially eligible studies were included focusing on the following subjects: extension of enamel preparation, adhesive procedures prior to restoration, application of fissure sealants as well as restoration with conventional glass ionomer cements (GIC), resin modified glass ionomer cements (RMGIC), resin composites, and indirect restorations. Seven clinical studies were controlled trials. However, only two included MIH-unaffected teeth as control. No meta-analysis was performed due to the heterogeneity of study designs (e.g. severity of MIH or the restorative materials investigated). Based on the present analysis, the annual failure rates were in average 21% for fissure sealants, 22% for GIC, 1-6% for RMGIC, 13-32% for resin composites, and 0-7% for indirect restorations. In summary, only few tendencies can be deduced from this review at a low level of evidence (number of studies): 1) preparation margins in sound enamel seem to be superior to preparations in hypomineralised enamel (1 study), 2) RMGIC seems to be superior to GIC (3 studies), 3) resin composites may be used for restoring all severities of MIH (7 studies) with self-etch and etch-and-rinse adhesive systems generally not performing differently (3 studies), and 4) in cases of severe MIH, indirect restorations showed a good clinical success (4 studies).


Assuntos
Hipoplasia do Esmalte Dentário , Incisivo , Hipoplasia do Esmalte Dentário/terapia , Restauração Dentária Permanente , Humanos , Dente Molar , Estudos Prospectivos , Estudos Retrospectivos
3.
Swiss Dent J ; 130(3): 244-225, 2020 Mar 09.
Artigo em Alemão | MEDLINE | ID: mdl-32162857
4.
Dent Mater ; 35(9): 1205-1213, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31146960

RESUMO

OBJECTIVES: To investigate short- and long-term bond strength ("repair bond strength"; RBS) of a resin composite to six restorative materials using either a silane and a bonding agent or a universal "one-step self-etch" adhesive system. METHODS: Specimens were produced from an amalgam, a direct resin composite, two indirect resin composites, a hybrid ceramic, and a feldspar ceramic and stored for 3 months in tap water (37 °C). All specimens were then sandblasted (Al2O3; 25 µm) and either treated with Monobond Plus and OptiBond FL Adhesive (MP-OFL) or with Scotchbond Universal (SBU). Filtek Z250 was used as "repair composite", and RBS was measured by means of a micro shear bond strength test after 24 h or after 1 year. RBS values (n = 15/group) were statistically analyzed (α = 0.05). RESULTS: RBS (MPa; mean values (standard deviations)) after 24 h for MP-OFL: 18.6 (3.2)-23.9 (5.0) and for SBU: 12.5 (4.9)-18.1 (4.6); after 1 year for MP-OFL: 8.9 (4.6)-19.8 (4.3) and for SBU: 5.6 (2.3)-18.8 (3.5). After 24 h, MP-OFL showed significantly higher RBS to the hybrid ceramic and the feldspar ceramic than did SBU (p ≤ 0.0001) whereas there was no significant difference in RBS for the other four restorative materials. After 1 year, MP-OFL showed significantly higher RBS to the feldspar ceramic than did SBU (p = 0.043) whereas there was no significant difference in RBS for the other five restorative materials. SIGNIFICANCE: The use of a silane and a bonding agent seems more versatile for repairing restorations than the use of a universal "one-step self-etch" adhesive system.


Assuntos
Colagem Dentária , Cerâmica , Resinas Compostas , Materiais Dentários , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Silanos , Propriedades de Superfície
5.
Biomed Res Int ; 2018: 3895356, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29850511

RESUMO

This study investigated the effect of SnCl2/AmF pretreatment on short- and long-term bond strength of resin composite to eroded dentin mediated by two self-etch, MDP-containing adhesive systems. 184 dentin specimens were produced from extracted human molars. Half the specimens (n = 92) were artificially eroded, and half were left untreated. For both substrates, half the specimens were pretreated with SnCl2/AmF, and half were left untreated. The specimens were treated with Clearfil SE Bond or Scotchbond Universal prior to application of resin composite. Microtensile bond strength (µTBS) was measured after 24 h or 1 year. Failure mode was detected and EDX was performed. µTBS results were statistically analyzed (α = 0.05). µTBS was significantly influenced by the dentin substrate (eroded < noneroded dentin) and storage time (24 h > 1 year; p < 0.0001) but not by pretreatment with SnCl2/AmF or adhesive system. The predominant failure mode was adhesive failure at the dentin-adhesive interface. The content of Sn was generally below detection limit. Pretreatment with SnCl2/AmF did not influence short- and long-term bond strength to eroded dentin. Bond strength was reduced after storage for one year, was lower to eroded dentin than to noneroded dentin, and was similar for the two adhesive systems.


Assuntos
Colagem Dentária , Dentina/efeitos dos fármacos , Fluoretos Tópicos/farmacologia , Compostos de Estanho/farmacologia , Erosão Dentária/patologia , Análise do Estresse Dentário , Humanos , Resistência à Tração , Desmineralização do Dente/patologia , Remineralização Dentária
6.
Biomed Res Int ; 2017: 1207208, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28875148

RESUMO

This study investigated the effect of benzalkonium chloride (BAC) modification of two adhesive systems on long-term bond strength to normal and artificially eroded dentin. A total of 128 extracted human molars were sectioned and the buccal and oral surfaces of each molar were ground until the dentin. One half was left untreated (normal dentin) while the other half underwent artificial erosion. Resin composite was bonded to the buccal or oral surface following treatment with Adper Scotchbond 1XT or OptiBond FL without or with 1% BAC incorporation. Shear bond strength (SBS) was measured after 24 h (100% humidity, 37°C) or 1 year (tap water, 37°C). SBS results were statistically analyzed (α = 0.05). SBS was significantly lower to artificially eroded dentin than to normal dentin (p < 0.001). Storage for 1 year had no effect on SBS to normal dentin but led to a significant decrease in SBS to artificially eroded dentin (p < 0.001). BAC incorporation decreased the 24 h SBS to normal dentin (p = 0.018), increased the 24 h SBS to eroded dentin (p = 0.001), and had no effect on the 1-year SBS for either substrate. Consequently, BAC incorporation did not improve bond durability.


Assuntos
Compostos de Benzalcônio/uso terapêutico , Materiais Dentários/uso terapêutico , Erosão Dentária/terapia , Compostos de Benzalcônio/química , Colagem Dentária , Materiais Dentários/química , Análise do Estresse Dentário , Dentina/química , Dentina/patologia , Humanos , Resistência ao Cisalhamento , Erosão Dentária/patologia
7.
J Adhes Dent ; 19(2): 169-176, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28439578

RESUMO

PURPOSE: To investigate the effect of relative humidity and saliva contamination on short- and long-term bond strength of two self-etch adhesives to normal and artificially eroded dentin. MATERIALS AND METHODS: A total of 480 dentin specimens were produced from extracted human molars. Half of the specimens (n = 240) were left untreated (normal dentin) whereas the other half (n = 240) were artificially eroded. The specimens were treated with Clearfil SE Bond (CSE) or Scotchbond Universal (SBU), and composite (Filtek Z250) was applied to the treated dentin surface under four experimental conditions: at a relative humidity of 45% or 85% without/with human saliva contamination. Shear bond strength (SBS) was measured after storage for 24 h (100% humidity; 37°C) or 1 year (tap water; 37°C). SBS results were statistically analyzed with a nonparametric ANOVA followed by Wilcoxon-Mann-Whitney tests (significance level: α = 0.05). RESULTS: SBS was significantly influenced by the dentin substrate (normal or artificially eroded dentin) and adhesive (p < 0.001) but not by relative humidity, saliva contamination, or storage. SBS significantly differed (all p < 0.001) following the ranking (MPa; medians [pooled]): SBU on normal dentin (21.1) > CSE on normal dentin (19.2) > SBU on artificially eroded dentin (17.1) > CSE on artificially eroded dentin (10.9). CONCLUSION: On normal dentin, the two self-etch adhesives showed stable bond strength over time even under adverse conditions such as high relative humidity and saliva contamination. However, erosively altered dentin had a detrimental effect on the bond strength of both the adhesives investigated.


Assuntos
Colagem Dentária , Adesivos Dentinários , Resinas Compostas , Cimentos Dentários , Dentina , Humanos , Umidade , Teste de Materiais , Saliva
8.
PLoS One ; 12(1): e0169680, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28081572

RESUMO

PURPOSE: To compare various pre-treatments serving as cleaning procedures of dentin on the bond strength of resin composite promoted by a universal adhesive system applied either in the absence or presence of simulated pulpal pressure. MATERIALS AND METHODS: Prior to application of the adhesive system (Scotchbond Universal) and resin composite (Filtek Z250), ground dentin surfaces were given one of five pre-treatments either without or with simulated pulpal pressure: 1) no pre-treatment, adhesive system in "self-etch" mode, 2) phosphoric acid etching, adhesive system in "total-etch" mode, 3) polishing with pumice on prophylaxis cup, 4) air abrasion with AIR-FLOW PLUS powder, 5) air abrasion with AIR-FLOW PERIO powder; n = 20/group of pre-treatment. After storage (37°C, 100% humidity, 24 h), micro shear bond strength was measured and data analyzed with parametric ANOVA including Bonferroni-Holm correction for multiple testing followed by Student's t tests (significance level: α = 0.05). RESULTS: The ANOVA found type of pre-treatment and simulated pulpal pressure to have no significant effect on dentin bond strength. The explorative post-hoc tests showed a negative effect of simulated pulpal pressure for phosphoric acid etching (adhesive system in "total-etch" mode; p = 0.020), but not for the other four pre-treatments (all p = 1.000). CONCLUSION: Air abrasion with powders containing either erythritol and chlorhexidine (AIR-FLOW PLUS) or glycine (AIR-FLOW PERIO) yielded dentin bond strengths similar to no pre-treatment, phosphoric acid etching, or polishing with pumice. Simulated pulpal pressure reduced the bond strength only when the self-etch adhesive system was used in total-etch mode.


Assuntos
Cimentos Dentários/química , Dentina/fisiologia , Pressão , Clorexidina/química , Colagem Dentária , Dentina/química , Higienizadores de Dentadura/química , Higienizadores de Dentadura/farmacologia , Eritritol/química , Glicina/química , Humanos , Microscopia Eletrônica de Varredura , Resistência ao Cisalhamento/efeitos dos fármacos , Propriedades de Superfície
9.
J Prosthet Dent ; 117(6): 767-774, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27836147

RESUMO

STATEMENT OF PROBLEM: Because of the different composition of resin-ceramic computer-aided design and computer-aided manufacturing (CAD-CAM) materials, their polishability and their micromechanical properties vary. Moreover, depending on the composition of the materials, their surface roughness and micromechanical properties are likely to change with time. PURPOSE: The purpose of this in vitro study was to investigate the effect of artificial toothbrushing and water storage on the surface roughness (Ra and Rz) and the micromechanical properties, surface hardness (Vickers [VHN]) and indentation modulus (EIT), of 5 different tooth-colored CAD-CAM materials when polished with 2 different polishing systems. MATERIAL AND METHODS: Specimens (n=40 per material) were cut from a composite resin (Paradigm MZ100; 3M ESPE), a feldspathic ceramic (Vitablocs Mark II; Vita Zahnfabrik), a resin nanoceramic (Lava Ultimate; 3M ESPE), a hybrid dental ceramic (Vita Enamic; Vita Zahnfabrik), and a nanocomposite resin (Ambarino High-Class; Creamed). All specimens were roughened in a standardized manner and polished either with Sof-Lex XT discs or the Vita Polishing Set Clinical. Surface roughness, VHN, and EIT were measured after polishing and after storage for 6 months (tap water, 37°C) with periodic, artificial toothbrushing. The surface roughness, VHN, and EIT results were analyzed with a nonparametric ANOVA followed by Kruskal-Wallis and exact Wilcoxon rank sum tests (α=.05). RESULTS: Irrespective of polishing system and of artificial toothbrushing and storage, Lava Ultimate generally showed the lowest surface roughness and Vitablocs Mark II the highest. As regards micromechanical properties, the following ranking of the CAD-CAM materials was found (from highest VHN/EIT to lowest VHN/EIT): Vitablocs Mark II > Vita Enamic > Paradigm MZ100 > Lava Ultimate > Ambarino High-Class. Irrespective of material and of artificial toothbrushing and storage, polishing with Sof-Lex XT discs resulted in lower surface roughness than the Vita Polishing Set Clinical (P≤.016). However, the polishing system generally had no influence on the micromechanical properties (P>.05). The effect of artificial toothbrushing and storage on surface roughness depended on the material and the polishing system: Ambarino High-Class was most sensitive to storage, Lava Ultimate and Vita Enamic were least sensitive. Artificial toothbrushing and storage generally resulted in a decrease in VHN and EIT for Paradigm MZ100, Lava Ultimate, and Ambarino High-Class but not for Vita Enamic and Vitablocs Mark II. CONCLUSIONS: Tooth-colored CAD-CAM materials with lower VHN and EIT generally showed better polishability. However, these materials were more prone to degradation by artificial toothbrushing and water storage than materials with higher VHN and EIT.


Assuntos
Desenho Assistido por Computador , Prótese Dentária , Escovação Dentária/efeitos adversos , Cerâmica/uso terapêutico , Resinas Compostas/uso terapêutico , Polimento Dentário/efeitos adversos , Polimento Dentário/métodos , Prótese Dentária/efeitos adversos , Prótese Dentária/métodos , Planejamento de Prótese Dentária , Dureza , Humanos , Técnicas In Vitro , Pigmentação em Prótese/métodos , Propriedades de Superfície , Água
10.
Dent Mater J ; 35(5): 728-735, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27546861

RESUMO

The aim was to investigate dentin bond strength of two resin-ceramic materials and five cements after 24 h and six months storage. Cylinders (n=15/group) of Lava Ultimate (3M ESPE) and VITA ENAMIC (VITA Zahnfabrik) were cemented to mid-coronal dentin of 300 extracted human molars with RelyX Ultimate (3M ESPE), PANAVIA F2.0 (Kuraray), Variolink II (Ivoclar Vivadent), els cem (Saremco Dental), or Ketac Cem Plus (3M ESPE). Shear bond strength (SBS) was measured after 24 h or six months storage (37°C, 100% humidity) and statistically analyzed (significance level: α=0.05). SBS varied markedly between Lava Ultimate and VITA ENAMIC, between the five cements, and between storage of either 24 h or six months. After six months, SBS was highest when Lava Ultimate was cemented with RelyX Ultimate and when VITA ENAMIC was cemented with RelyX Ultimate or with Variolink II. Lava Ultimate was somewhat more sensitive to storage than was VITA ENAMIC.


Assuntos
Desenho Assistido por Computador , Colagem Dentária , Dentina , Cerâmica , Porcelana Dentária , Análise do Estresse Dentário , Adesivos Dentinários , Humanos , Teste de Materiais , Cimentos de Resina
11.
Biomed Res Int ; 2016: 4894653, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28044129

RESUMO

This study investigated the influence of light-curing at high irradiances on micromechanical properties of resin cements. Three dual-curing resin cements and a light-curing flowable resin composite were light-cured with an LED curing unit in Standard mode (SM), High Power mode (HPM), or Xtra Power mode (XPM). Maximum irradiances were determined using a MARC PS radiometer, and exposure duration was varied to obtain two or three levels of radiant exposure (SM: 13.2 and 27.2 J/cm2; HPM: 15.0 and 30.4 J/cm2; XPM: 9.5, 19.3, and 29.7 J/cm2) (n = 17). Vickers hardness (HV ) and indentation modulus (EIT) were measured at 15 min and 1 week. Data were analyzed with nonparametric ANOVA, Wilcoxon-Mann-Whitney tests, and Spearman correlation analyses (α = 0.05). Irradiation protocol, resin-based material, and storage time and all interactions influenced HV and EIT significantly (p ≤ 0.0001). Statistically significant correlations between radiant exposure and HV or EIT were found, indicating that high-irradiance light-curing has no detrimental effect on the polymerization of resin-based materials (p ≤ 0.0021). However, one resin cement was sensitive to the combination of irradiance and exposure duration, with high-irradiance light-curing resulting in a 20% drop in micromechanical properties. The results highlight the importance of manufacturers issuing specific recommendations for the light-curing procedure of each resin cement.


Assuntos
Resinas Compostas/química , Materiais Dentários/química , Cimentos de Resina/química , Lâmpadas de Polimerização Dentária , Dureza , Teste de Materiais/métodos , Polimerização , Propriedades de Superfície
12.
J Adhes Dent ; 17(3): 249-56, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26114164

RESUMO

PURPOSE: To investigate the influence of relative humidity and application time on bond strength to dentin of different classes of adhesive systems. MATERIALS AND METHODS: A total of 360 extracted human molars were ground to mid-coronal dentin. The dentin specimens were treated with one of six adhesive systems (Syntac Classic, OptiBond FL, Clearfil SE Bond, AdheSE, Xeno Select, or Scotchbond Universal), and resin composite (Filtek Z250) was applied to the treated dentin surface under four experimental conditions (45% relative humidity/application time according to manufacturers' instructions; 45% relative humidity/reduced application time; 85% relative humidity/application time according to manufacturers' instructions; 85% relative humidity/reduced application time). After storage (37°C, 100% humidity, 24 h), shear bond strength (SBS) was measured and data analyzed with nonparametric ANOVA followed by Kruskal-Wallis tests and Mann-Whitney U-tests with Bonferroni-Holm correction for multiple testing (level of significance: α = 0.05). RESULTS: Increased relative humidity and reduced application time had no effect on SBS for Clearfil SE Bond and Scotchbond Universal (p = 1.00). For Syntac Classic, OptiBond FL, AdheSE, and Xeno Select there was no effect on SBS of reduced application time of the adhesive system (p ≥ 0.403). However, increased relative humidity significantly reduced SBS for Syntac Classic, OptiBond FL, and Xeno Select irrespective of application time (p ≤ 0.003), whereas for AdheSE, increased relative humidity significantly reduced SBS at recommended application time only (p = 0.002). CONCLUSION: Generally, increased relative humidity had a detrimental effect on SBS to dentin, but reduced application time had no effect.


Assuntos
Resinas Compostas/química , Colagem Dentária , Materiais Dentários/química , Adesivos Dentinários/química , Dentina/ultraestrutura , Resinas Acrílicas/química , Humanos , Umidade , Teste de Materiais , Cimentos de Resina/química , Resistência ao Cisalhamento , Estresse Mecânico , Temperatura , Fatores de Tempo
13.
PLoS One ; 10(6): e0131056, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26121365

RESUMO

BACKGROUND AND AIM: There is a lack of suitable in vitro models to evaluate various treatment modalities intending to remove subgingival bacterial biofilm. Consequently, the aims of this in vitro-study were: a) to establish a pocket model enabling mechanical removal of biofilm and b) to evaluate repeated non-surgical periodontal treatment with respect to biofilm removal and reformation, surface alterations, tooth hard-substance-loss, and attachment of periodontal ligament (PDL) fibroblasts. MATERIAL AND METHODS: Standardized human dentin specimens were colonized by multi-species biofilms for 3.5 days and subsequently placed into artificially created pockets. Non-surgical periodontal treatment was performed as follows: a) hand-instrumentation with curettes (CUR), b) ultrasonication (US), c) subgingival air-polishing using erythritol (EAP) and d) subgingival air-polishing using erythritol combined with chlorhexidine digluconate (EAP-CHX). The reduction and recolonization of bacterial counts, surface roughness (Ra and Rz), the caused tooth substance-loss (thickness) as well as the attachment of PDL fibroblasts were evaluated and statistically analyzed by means of ANOVA with Post-Hoc LSD. RESULTS: After 5 treatments, bacterial reduction in biofilms was highest when applying EAP-CHX (4 log10). The lowest reduction was found after CUR (2 log10). Additionally, substance-loss was the highest when using CUR (128±40 µm) in comparison with US (14±12 µm), EAP (6±7 µm) and EAP-CHX (11±10) µm). Surface was roughened when using CUR and US. Surfaces exposed to US and to EAP attracted the highest numbers of PDL fibroblasts. CONCLUSION: The established biofilm model simulating a periodontal pocket combined with interchangeable placements of test specimens with multi-species biofilms enables the evaluation of different non-surgical treatment modalities on biofilm removal and surface alterations. Compared to hand instrumentation the application of ultrasonication and of air-polishing with erythritol prevents from substance-loss and results in a smooth surface with nearly no residual biofilm that promotes the reattachment of PDL fibroblasts.


Assuntos
Biofilmes , Fibroblastos/patologia , Modelos Biológicos , Ligamento Periodontal/microbiologia , Ligamento Periodontal/patologia , Bolsa Periodontal/microbiologia , Bactérias/crescimento & desenvolvimento , Adesão Celular , Contagem de Colônia Microbiana , Dentina/patologia , Humanos , Ligamento Periodontal/cirurgia , Bolsa Periodontal/patologia , Bolsa Periodontal/cirurgia , Propriedades de Superfície , Dente/patologia
14.
J Adhes Dent ; 17(1): 51-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25625136

RESUMO

PURPOSE: To evaluate the effects of human saliva contamination and two decontamination procedures at different stages of the bonding procedure on the bond strength of two one-step self-etching adhesives to primary and permanent dentin. MATERIALS AND METHODS: Extracted human primary and permanent molars (210 of each) were ground to mid-coronal dentin. The dentin specimens were randomly divided into 7 groups (n = 15/group/molar type) for each adhesive (Xeno V+ and Scotchbond Universal): no saliva contamination (control); saliva contamination before or after light curing of the adhesives followed by air drying, rinsing with water spray/air drying, or by rinsing with water spray/air drying/reapplication of the adhesives. Resin composite (Filtek Z250) was applied on the treated dentin surfaces. The specimens were stored at 37°C and 100% humidity for 24 h. After storage, shear bond strength (SBS) was measured and data analyzed with nonparametric ANOVA followed by exact Wilcoxon rank sum tests. RESULTS: Xeno V+ generated significantly higher SBS than Scotchbond Universal when no saliva contamination occurred. Saliva contamination reduced SBS of Xeno V+, with the reduction being more pronounced when contamination occurred before light curing than after. In both situations, decontamination involving reapplication of the adhesive restored SBS. Saliva contamination had no significant effect on Scotchbond Universal. There were no differences in SBS between primary and permanent teeth. CONCLUSION: Rinsing with water and air drying followed by reapplication of the adhesive restored bond strength to saliva-contaminated dentin.


Assuntos
Colagem Dentária , Adesivos Dentinários/química , Dentina/ultraestrutura , Saliva/química , Dente Decíduo/ultraestrutura , Adesividade , Ar , Resinas Compostas/química , Cimentos Dentários/química , Análise do Estresse Dentário/instrumentação , Dessecação , Humanos , Umidade , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Cimentos de Resina/química , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo , Água/química
15.
Am J Dent ; 28(6): 362-6, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26846043

RESUMO

PURPOSE: To investigate the effect of airborne-particle abrasion or diamond bur preparation as pre-treatment steps of non-carious cervical root dentin regarding substance loss and bond strength. METHODS: 45 dentin specimens-produced from crowns of extracted human incisors by grinding the labial surfaces with silicon carbide papers (control) were treated with one of three adhesive systems (Group 1A-C; A: OptiBond FL, B: Clearfil SE Bond, or C: Scotchbond Universal; n= 15/adhesive system). Another 135 dentin specimens (n = 15/group) produced from the labial, non-carious cervical root part of extracted human incisors were treated with one of the adhesive systems after either no pre-treatment (Group 2A-C), pre-treatment with airborne-particle abrasion (CoJet Prep and 50 µm aluminum oxide powder; Group 3A-C), or pre-treatment with diamond bur preparation (40 µm grit size; Group 4A-C). Substance loss caused by the pre-treatment was measured in Groups 3 and 4. After treatment with the adhesive systems, resin composite was applied and all specimens were stored (37°C, 100% humidity, 24 hours) until measurement of micro-shear bond strength (µSBS). Data were analyzed with a nonparametric ANOVA followed by Kruskal-Wallis and Wilcoxon rank sum tests (level of significance: α = 0.05). RESULTS: Overall substance loss was significantly lower in Group 3 (median: 19 µm) than in Group 4 (median: 113 µm; P < 0.0001). There were no significant differences in µSBS between the adhesive systems (A-C) in Group 1, Group 3, and Group 4 (P 0.133). In Group 2, OptiBond FL (Group 2A) and Clearfil SE Bond (Group 2B) yielded significantly higher µSBS than Scotchbond Universal (Group 2C; P ≤ 0.032). For OptiBond FL and Clearfil SE Bond, there were no significant differences in µSBS between the ground crown dentin and the non-carious cervical root dentin regardless of any pre-treatment of the latter (both P = 0.661). For Scotchbond Universal, the µSBS to non-carious cervical root dentin without pre-treatment was significantly lower than to ground crown dentin and to non-carious cervical root dentin pre-treated with airborne-particle abrasion or diamond bur preparation (P ≤ 0.014).


Assuntos
Colagem Dentária , Corrosão Dentária/métodos , Dentina/ultraestrutura , Raiz Dentária/ultraestrutura , Óxido de Alumínio/química , Compostos Inorgânicos de Carbono/química , Resinas Compostas/química , Materiais Dentários/química , Diamante/química , Humanos , Umidade , Teste de Materiais , Cimentos de Resina/química , Resistência ao Cisalhamento , Compostos de Silício/química , Estresse Mecânico , Temperatura , Fatores de Tempo
16.
Dent Mater ; 30(10): 1104-12, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25086481

RESUMO

OBJECTIVES: To investigate the influence of increment thickness on Vickers microhardness (HV) and shear bond strength (SBS) to dentin of a conventional and four bulk fill resin composites. METHODS: HV and SBS were determined on specimens of the conventional resin composite Filtek Supreme XTE (XTE) and the bulk fill resin composites SDR (SDR), Filtek Bulk Fill (FBF), x-tra fil (XFIL), and Tetric EvoCeram Bulk Fill (TEBF) after 24h storage. HV was measured either as profiles at depths up to 6mm or at the bottom of 2mm/4mm/6mm thick resin composite specimens. SBS of 2mm/4mm/6mm thick resin composite increments was measured to dentin surfaces of extracted human molars treated with the adhesive system OptiBond FL, and the failure mode was stereomicroscopically determined at 40× magnification. HV profiles and failure modes were descriptively analysed whereas HV at the bottom of resin composite specimens and SBS were statistically analysed with nonparametric ANOVA followed by Wilcoxon rank sum tests (α=0.05). RESULTS: HV profiles (medians at 2mm/4mm/6mm): XTE 105.6/88.8/38.3, SDR 34.0/35.5/36.9, FBF 36.4/38.7/37.1, XFIL 103.4/103.9/101.9, TEBF 63.5/59.7/51.9. HV at the bottom of resin composite specimens (medians at 2mm/4mm/6mm): XTE (p<0.0001) 105.5>85.5>31.1, SDR (p=0.10) 25.8=21.9=26.0, FBF (p=0.16) 26.6=25.3=28.9, XFIL (p=0.18) 110.5=107.2=101.9, TEBF (p<0.0001) 63.0>54.9>48.2. SBS (MPa, medians at 2mm/4mm/6mm): XTE (p<0.0001) 23.9>18.9=16.7, SDR (p=0.26) 24.6=22.7=23.4, FBF (p=0.11) 21.4=20.3=22.0, x-tra fil (p=0.55) 27.0=24.0=23.6, TEBF (p=0.11) 21.0=20.7=19.0. The predominant SBS failure mode was cohesive failure in dentin. SIGNIFICANCE: At increasing increment thickness, HV and SBS decreased for the conventional resin composite but generally remained constant for the bulk fill resin composites.


Assuntos
Resinas Compostas , Dentina , Testes de Dureza , Resistência ao Cisalhamento
17.
J Dent ; 42(9): 1185-92, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25019363

RESUMO

OBJECTIVE: To investigate how the modulus of elasticity of resin composites influences marginal quality in restorations submitted to thermocyclic and mechanical loading. METHODS: Charisma, Filtek Supreme XTE and Grandio were selected as they were found to possess different moduli of elasticity but quite similar polymerization contraction. MOD cavities (n=30) were prepared in extracted premolars, restored and then subjected to thermocyclic and mechanical loading. Marginal quality of the restorations before and after loading was analyzed on epoxy replicas under a scanning electron microscope. The percentage of gap-free margins and occurrence of paramarginal fractures were registered. Modulus of elasticity and polymerization contraction were analyzed with parametric and margins with nonparametric ANOVA and post hoc Tukey HSD or Wilcoxon rank-sum tests, respectively. The number of paramarginal fractures was analyzed with exact Fisher tests (α=0.05). RESULTS: Grandio demonstrated significantly more gap-free enamel margins than Charisma and Filtek Supreme XTE, before and after loading (p<0.01), whereas there was no difference between Charisma and Filtek Supreme XTE (p>0.05). No significant effect of resin composite (p=0.81) on the quality of dentine margins was observed, before or after loading. Deterioration of all margins was evident after loading (p<0.0001). More paramarginal enamel fractures were observed after loading in teeth restored with Grandio when compared to Charisma (p=0.008). CONCLUSIONS: The resin composite with the highest modulus of elasticity resulted in the highest number of gap-free enamel margins but with an increased incidence of paramarginal enamel fractures. CLINICAL SIGNIFICANCE: The results from this study suggest that the marginal quality of restorations can be improved by the selection of a resin composite with modulus of elasticity close to that of dentine, although an increase in paramarginal enamel fractures can result as a consequence.


Assuntos
Resinas Compostas/química , Adaptação Marginal Dentária , Materiais Dentários/química , Condicionamento Ácido do Dente/métodos , Preparo da Cavidade Dentária/classificação , Esmalte Dentário/ultraestrutura , Restauração Dentária Permanente/classificação , Restauração Dentária Permanente/normas , Dentina/ultraestrutura , Módulo de Elasticidade , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Polimerização , Técnicas de Réplica , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo , Água/química
18.
Dent Mater ; 30(4): 442-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24522149

RESUMO

OBJECTIVES: The aim of this study was to forecast trends in restorative dentistry over the next 20 years and to identify treatment goals and corresponding properties of restorative materials. METHODS: Using the Delphi method, a panel of 3 experts identified 8 key questions, which were sent to experts in restorative and preventive dentistry. In round 1 of this survey, 15 international experts devised a clearer semantic definition of the key questions and the completion of respective items for two additional rounds. In round 2, 125 experts from 35 countries rated the items developed in round 1 using a Likert scale. In round 3, the same 125 experts received the ratings of round 2 and were asked to agree or disagree to these ratings by re-voting on all key questions and items. A total of 105 experts re-voted and finally took part in the complete survey. Among the 8 key questions, two questions were selected for the present report: (Q1) "What will be the future role of restorative treatment?" and (Q6) "What will be the key qualities for clinical success of restorations?" For both questions and the respective items, the experts were asked to evaluate the importance and the feasibility for later calculation of the scientific value (i.e. the opportunity, where opportunity=importance+[importance-feasibility]). RESULTS: The three items of highest importance for Q1 were "preservation of existing enamel and dentin tissue," "prevention of secondary caries," and "maintenance of the pulp vitality," and for Q6 they were "optimization of adhesion," "biocompatibility," and "minimizing technical sensitivity." SIGNIFICANCE: Bioactivity toward the pulp-dentin complex and prevention of secondary caries were the items generally rated as having the highest opportunity.


Assuntos
Técnica Delphi , Materiais Dentários , Restauração Dentária Permanente/tendências , Previsões , Humanos
19.
Clin Oral Investig ; 18(2): 535-43, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23592063

RESUMO

OBJECTIVES: To determine the effect on resin composite-to-dentin bond strength of incorporation of an acidic tin-chloride pretreatment in two adhesive systems. MATERIALS AND METHODS: Human molars were ground to expose mid-coronal dentin. For microtensile bond strength (µTBS) testing, dentin was treated with Optibond FL or Clearfil SE according to one of six protocols (n = 22/group). Group 1: Phosphoric acid etching, Optibond FL Prime, Optibond FL Adhesive (manufacturer's instructions; control); Group 2: Tin-chloride pretreatment, Optibond FL Prime, Optibond FL Adhesive; Group 3: Phosphoric acid etching, tin-chloride pretreatment, Optibond FL Prime, Optibond FL Adhesive; Group 4: Clearfil SE Primer, Clearfil SE Bond (manufacturer's instructions; control); Group 5: Phosphoric acid etching, Clearfil SE Primer, Clearfil SE Bond; and Group 6: Tin-chloride pretreatment, Clearfil SE Primer, Clearfil SE Bond. The molars were then built up with resin composite (Clearfil Majesty Esthetic). After storage (1 week, 100 % humidity, 37 °C) the µTBS was measured and failure mode was determined. Additionally, pretreated dentin surfaces were evaluated using SEM and EDX. The µTBS results were analyzed statistically by a Welch Two Sample t-test and a Kruskal-Wallis test followed by exact Wilcoxon rank sum tests with Bonferroni-Holm adjustment for multiple testing (α = 0.05). RESULTS: When Optibond FL was used, partial or total replacement of phosphoric acid with tin-chloride decreased µTBS significantly. In contrast, when Clearfil SE was used, inclusion of a tin-chloride pretreatment in the adhesive procedure increased µTBS significantly. CONCLUSIONS: Tin-chloride pretreatment had a beneficial influence on the bond promoting capacity of the MDP-containing adhesive system Clearfil SE.


Assuntos
Cimentos Dentários , Dentina/química , Compostos de Estanho/química , Humanos , Microscopia Eletrônica de Varredura , Espectrometria por Raios X , Propriedades de Superfície
20.
Clin Oral Investig ; 18(3): 809-18, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23929361

RESUMO

OBJECTIVES: The aim of this study was to investigate micromechanical properties of five dual-curing resin cements after different curing modes including light curing through glass ceramic materials. MATERIALS AND METHODS: Vickers hardness (VH) and indentation modulus (Y HU) of Panavia F2.0, RelyX Unicem 2 Automix, SpeedCEM, BisCem, and BeautiCem SA were measured after 1 week of storage (37 °C, 100 % humidity). The resin cements were tested following self-curing or light curing with the second-generation light-emitting diode (LED) curing unit Elipar FreeLight 2 in Standard Mode (1,545 mW/cm(2)) or with the third-generation LED curing unit VALO in High Power Mode (1,869 mW/cm(2)) or in XtraPower Mode (3,505 mW/cm(2)). Light curing was performed directly or through glass ceramic discs of 1.5 or 3 mm thickness of IPS Empress CAD or IPS e.max CAD. VH and Y HU were analysed with Kruskal-Wallis tests followed by pairwise Wilcoxon rank sum tests (α = 0.05). RESULTS: RelyX Unicem 2 Automix resulted in the highest VH and Y HU followed by BeautiCem SA, BisCem, SpeedCEM, and finally Panavia F2.0. Self-curing of RelyX Unicem 2 Automix and SpeedCEM lowered VH and Y HU compared to light curing whereas self-curing of Panavia F2.0, BisCem, and BeautiCem SA led to similar or significantly higher VH and Y HU compared to light curing. Generally, direct light curing resulted in similar or lower VH and Y HU compared to light curing through 1.5-mm-thick ceramic discs. Light curing through 3-mm-thick discs of IPS e.max CAD generally reduced VH and Y HU for all resin cements except SpeedCEM, which was the least affected by light curing through ceramic discs. CONCLUSIONS: The resin cements responded heterogeneously to changes in curing mode. The applied irradiances and light curing times adequately cured the resin cements even through 1.5-mm-thick ceramic discs. CLINICAL RELEVANCE: When light curing resin cements through thick glass ceramic restorations, clinicians should consider to prolong the light curing times even with LED curing units providing high irradiances.


Assuntos
Cerâmica , Resinas Compostas , Lâmpadas de Polimerização Dentária , Vidro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...