Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 129(1-3): 119-22, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18487616

RESUMO

Recent advances in semiconductor pixel detectors and read-out electronics allowed to build the first prototypes of single photon-counting imaging systems that represent the last frontier of digital radiography. Among the advantages with respect to commercially available digital imaging systems, there are direct conversion of photon energy into electrical charge and the effective rejection of electronic noise by means of a thresholding process. These features allow the photon-counting systems to achieve high imaging performances in terms of spatial and contrast resolution. Moreover, the now available deep integration techniques allow the reduction of the pixel size and the improvement of the functionality of the single cell and the read-out speed so as to cope with the high fluxes found in diagnostic radiology. In particular, the single photon-counting system presented in this paper is based on a 300-microm thick silicon pixel detector bump-bonded to the Medipix2 read-out chip to form an assembly of 256 x 256 square pixels at a pitch of 55 microm. Each cell comprises a low-noise preamplifier, two pulse height discriminators and a 14-bit counter. The maximum counting rate per pixel is 1 MHz. The chip can operate in two modalities: it records the events with energy above a threshold (single mode) or between two energy thresholds (window mode). Exploiting this latter feature, a possible application of such a system as a fast spectrometer is presented to study the energy spectrum of diagnostic beams produced by X-ray tubes.


Assuntos
Diagnóstico por Imagem , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Fótons , Tomografia Computadorizada por Raios X/métodos , Humanos , Aumento da Imagem/instrumentação , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Radiometria , Tomografia Computadorizada por Raios X/instrumentação
2.
Radiat Prot Dosimetry ; 129(1-3): 227-30, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18375463

RESUMO

The work presented here was developed in the framework of the SENTINEL Project and is devoted to the analysis of dental radiology dosimetric data. The procedure of data processing allows the analysis of some important aspects related to the protection of the patient and the staff because of the position of the operators near the patient and their exposure to the radiation scattered by the patient. Dental radiology data was collected in an Italian hospital. Following the Italian quality assurance (QA) protocols and suggestions by the leaders of the SENTINEL Project, X-ray equipment performances have been analysed in terms of: kVp accuracy, exposure time accuracy and precision, tube output, dose reproducibility and linearity, beam collimation, artefacts and light tightness. Referring to these parameters the physical quality index (QI) was analysed. In a single numerical value between 0 and 1, QI summarises the results of quality tests for radiological devices. The actual impact of such a figure (as suggested by international QA protocols or as adopted by local QA routine) on the policy of machine maintenance and replacement is discussed.


Assuntos
Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/normas , Proteção Radiológica/normas , Radiografia Dentária/métodos , Serviço Hospitalar de Radiologia/normas , Radiometria/métodos , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Controle de Qualidade , Radiografia Dentária/instrumentação , Radiometria/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...