1.
Ann Cardiol Angeiol (Paris) ; 52(6): 353-7, 2003 Dec.
Artigo em Francês | MEDLINE | ID: mdl-14752917

RESUMO

Cardiac echodoppler is an efficient tool to analyse cardiac mechanic loop. Diastolic and systolic desynchronisation criteria are analysed. It should allow a more efficient selection of patients who could take benefit of resynchronization therapy, but also to choose resynchronization system, to program optimal atrioventricular delay, interventricular delay and to evaluate resynchronization efficiency. However, this tool should be evaluated in large studies in order to compare it to electrocardiogram.


Assuntos
Estimulação Cardíaca Artificial , Ecocardiografia Doppler , Insuficiência Cardíaca/terapia , Seleção de Pacientes , Diástole/fisiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Sístole/fisiologia
2.
Ann Cardiol Angeiol (Paris) ; 51(5): 289-95, 2002 Nov.
Artigo em Francês | MEDLINE | ID: mdl-12515106

RESUMO

Cardiac pacing has been proposed for patients with advanced heart failure refractory to optimal drug treatment and having conduction disorders to resynchronize mechanical activity of the heart. Activation asynchronism as caused by bundle branch block results in alteration of systolic function and arrhythmias. A too short or too long atrio-ventricular delay can also affect diastolic ventricular filling. Early clinical studies showed a benefit of very long atrioventricular delays shortening, not confirmed by further studies. Direct stimulation of the left ventricle was beneficial in acute hemodynamic studies. Three controlled clinical studies now completed, PATH-CHF, MYSTIC and MIRACLE have showed a functional benefit. Other studies (COMPANION, CARE-HF) are currently in process to evaluate the effect on survival and the interest to associate an automatic defibrillator. Technical aspects are also under investigation: optimal lead placement in the coronary venous system, types of leads, special pacing devices. This paper reports the experience of the first 50 patients treated with multisite pacing in Aix-en-Provence general hospital, 33 men and 17 women, 71 years of mean age, on NYHA class III or IV, and showing QRS width above 120 ms. During the follow-up (mean duration 16 months) 15 deaths (30%) happened. The benefit on NYHA class was 1.34; rehospitalization rate was low. Coronary sinus access was successful in 100% of cases. Sixteen per cent had a reintervention for lead displacement or threshold elevation. Left atrioventricular crosstalk, observed in six patients, supports the use of devices with three independent channels. Echocardiography is of interest for responders identification, optimal device programming and follow-up.


Assuntos
Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Bloqueio de Ramo/complicações , Estimulação Cardíaca Artificial/métodos , Desfibriladores Implantáveis , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
3.
Arch Mal Coeur Vaiss ; 91 Spec No 1: 61-9, 1998 Mar.
Artigo em Francês | MEDLINE | ID: mdl-9749286

RESUMO

Some electrocardiographic appearances in cardiac pacing may suggest pacemaker dysfunction but in fact the unit may be functioning normally or have a minor fault which is easy to correct by reprogramming. A pacing rate different to that programmed may be due to the rate-response hysteresis or rate smoothing functions. Irregular pacing is often due to phenomena of inappropriate sensing. A pacemaker in the bipolar AAI mode may seem to have no output if the spike is not visible: function in AAI mode should not be interpreted as pacing catheter displacement. The practician may wrongly interpret faulty ventricular sensing in patients with AAI pacemakers and atrial fibrillation when irregular pacing is observed or when ventricular extrasystoles do not inhibit the pacemaker. In dual chamber pacing, the blanking period may result in inadequate ventricular stimulation. The phenomenon of crossed detection or cross-talk is a cause of inappropriate inhibition. Applications of the magnet blocks the sensing function: the magnet pacemaker rate is an indicator of pacemaker end of life. In fact, the magnet induces different behaviours depending on the model of pacemaker which makes it essential to know the special characteristics of each pacemaker. The application of the magnet may trigger arrhythmias or no output of pacemakers at the end of life. The A-V interval may vary with respect to its response to the heart rate, when there is a hysteresis function of the A-V interval, sensing in the "safety" gap or when anti-atrial trachycardia algorithms are activated. The acceleration of a dual-chamber pacemaker may be related to electronic reentrant tachycardia or to an atrial tachycardia: a fault or delayed activation of various anti-arrhythmic algorithms may also cause difficulties in the interpretation of the electrocardiogram.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Eletrocardiografia , Arritmias Cardíacas/fisiopatologia , Eletrofisiologia , Humanos
4.
Arch Mal Coeur Vaiss ; 90(11): 1545-8, 1997 Nov.
Artigo em Francês | MEDLINE | ID: mdl-9539830

RESUMO

A seventeen year old girl with anorexia nervosa (32 kg; 165 cm) was admitted as an emergency after syncope with severe bradycardia resistant to atropine monitored over a one week period. Autonomic blockade confirmed the intrinsic character of the sinus node dysfunction with chronotropic incompetence on exercise. Secondarily, a Mobitz I second degree AVB was observed. A DDDR pacemaker was implanted with an excellent functional result. With a one year follow-up, the bradycardia persists but body weight has increased. The authors discuss the physiopathology of this case: in the literature, the classical bradycardia of anorexia nervosa is sensitive to vagolytic drugs and only exceptionally as intense as in this patient. Sinus node dysfunction is very rare in the young in the absence of congenital heart disease. It is possible that the bradycardia had become chronic in this case.


Assuntos
Anorexia Nervosa/complicações , Bradicardia/etiologia , Bradicardia/terapia , Marca-Passo Artificial , Adolescente , Anorexia Nervosa/fisiopatologia , Diagnóstico Diferencial , Feminino , Frequência Cardíaca , Humanos , Nó Sinoatrial/fisiopatologia , Síncope/etiologia , Resultado do Tratamento