Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Stroke ; 18(1): 102-108, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35361018

RESUMO

BACKGROUND AND AIMS: Cerebral small vessel disease (CSVD) is the main cause of intracerebral hemorrhage (ICH) in older individuals but has not been systematically studied in younger people. We aimed to evaluate the prevalence and characteristics of CSVD in young adults with symptomatic ICH. METHODS: We conducted a cohort study of consecutive adults aged 18-50 years with non-traumatic ICH. All patients were evaluated with brain and vascular imaging. Using validated imaging markers (cerebral microbleeds (CMBs), white matter hyperintensities and/or lacunes), patients were categorized as having CSVD-related ICH or non-CSVD-related ICH. Factors associated with CSVD were evaluated using multivariable analyses. CSVD subtypes were characterized using pre-specified criteria. RESULTS: Of 146 young adults with ICH (mean age = 37.7), CSVD was present in 41 patients (28.1%; 95% confidence interval (CI) = 21.0-36.1). In multivariable analysis, older age, male sex, and hypertension were independently associated with the presence of CSVD. Deep perforator arteriopathy (48.8%) and mixed CSVD (31.7%) were the most common CSVD subtypes. CONCLUSION: Our results suggest that CSVD is a frequent cause of ICH in young adults and provide new insights into the characterization of the disease. These findings may have important implications since the treatment and management differ from other causes of ICH.


Assuntos
Doenças de Pequenos Vasos Cerebrais , Acidente Vascular Cerebral , Humanos , Masculino , Adulto Jovem , Idoso , Adulto , Estudos de Coortes , Prevalência , Acidente Vascular Cerebral/complicações , Imageamento por Ressonância Magnética/métodos , Hemorragia Cerebral/complicações , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/epidemiologia , Doenças de Pequenos Vasos Cerebrais/complicações , Doenças de Pequenos Vasos Cerebrais/diagnóstico por imagem , Doenças de Pequenos Vasos Cerebrais/epidemiologia
2.
J Neuroimaging ; 32(5): 894-901, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35811446

RESUMO

BACKGROUND AND PURPOSE: Carotid web (CaW) is a cause of recurrent ischemic stroke that remains underdiagnosed using Duplex ultrasound (DUS). Improved methods and description of its ultrasound's features could allow better detection of CaW. Ultrasound microflow imaging (MFI) is a blood flow imaging technique sensitive to slow flow that could increase CaW detection. This study aimed to describe ultrasound features of CaW using B-mode imaging and MFI. METHODS: In a retrospective monocentric study, patients with CaW on CT angiography who underwent DUS examination of carotid arteries were included. DUS was performed by two nonblinded experienced neurosonologists. The specificity of CaW ultrasound features was evaluated using a group of patients with carotid atherosclerotic plaque (AP). RESULTS: Twenty-four patients with CaW were included. Mean age (standard deviation) was 48 years (11). Seventeen (71%) were females. Fifteen (63%) CaWs were symptomatic. MFI was available for 22 patients. B-mode imaging demonstrated the characteristic CaW appearance in 19/24 (79%) patients as a protruding triangular iso-hypoechoic lesion on longitudinal view. CaW were detected on axial view in only 9/24 (38%) patients. MFI displayed slow blood flow above CaW during systole and allowed it delineation, appearing as a thin triangular endoluminal defect in 18/22 (82%) cases. Based on MFI and B-mode, 21/22 (95%) CaWs were visible, including three CaWs only with MFI. These ultrasound features were not found among 24 patients with AP. CONCLUSION: We report the ultrasound features from a series of 24 CaW. The use of MFI in addition to B-mode imaging improved the detection rate of CaW.


Assuntos
Estenose das Carótidas , Placa Aterosclerótica , Artérias Carótidas/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Criança , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Estudos Retrospectivos , Ultrassonografia , Ultrassonografia Doppler Dupla
3.
Stroke ; 53(11): 3429-3438, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35862225

RESUMO

BACKGROUND: Whether bridging therapy (intravenous thrombolysis [IVT] followed by mechanical thrombectomy) is superior to IVT alone in minor stroke with large vessel occlusion is unknown. Perfusion imaging may identify subsets of large vessel occlusion-related minor stroke patients with distinct response to bridging therapy. METHODS: We conducted a multicenter international observational study of consecutive IVT-treated patients with minor stroke (National Institutes of Health Stroke Scale score ≤5) who had an anterior circulation large vessel occlusion and perfusion imaging performed before IVT, with a subset undergoing immediate thrombectomy. Propensity score with inverse probability of treatment weighting was used to account for baseline between-groups differences. The primary outcome was 3-month modified Rankin Scale score 0 to 1. We searched for an interaction between treatment group and mismatch volume (critical hypoperfusion-core volume). RESULTS: Overall, 569 patients were included (172 and 397 in the bridging therapy and IVT groups, respectively). After propensity-score weighting, the distribution of baseline variables was similar across the 2 groups. In the entire population, bridging was associated with lower odds of achieving modified Rankin Scale score 0 to 1: odds ratio, 0.73 [95% CI, 0.55-0.96]; P=0.03. However, mismatch volume modified the effect of bridging on clinical outcome (Pinteraction=0.04 for continuous mismatch volume); bridging was associated with worse outcome in patients with, but not in those without, mismatch volume <40 mL (odds ratio, [95% CI] for modified Rankin Scale score 0-1: 0.48 [0.33-0.71] versus 1.14 [0.76-1.71], respectively). Bridging was associated with higher incidence of symptomatic intracranial hemorrhage in the entire population, but this effect was present in the small mismatch subset only (Pinteraction=0.002). CONCLUSIONS: In our population of large vessel occlusion-related minor stroke patients, bridging therapy was associated with lower rates of good outcome as compared with IVT alone. However, mismatch volume was a strong modifier of the effect of bridging therapy over IVT alone, notably with worse outcome with bridging therapy in patients with mismatch volume ≤40 mL. Randomized trials should consider adding perfusion imaging for patient selection.


Assuntos
Arteriopatias Oclusivas , Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/terapia , Isquemia Encefálica/complicações , Resultado do Tratamento , Acidente Vascular Cerebral/terapia , Acidente Vascular Cerebral/tratamento farmacológico , Trombectomia/métodos , Imagem de Perfusão , Arteriopatias Oclusivas/complicações , Terapia Trombolítica/métodos , Fibrinolíticos/uso terapêutico
4.
Stroke ; 52(12): e769-e772, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34702062

RESUMO

BACKGROUND AND PURPOSE: Determining the mechanism of large vessel occlusion related acute ischemic stroke is of major importance to initiate a tailored secondary prevention strategy. We investigated using the atherosclerosis, small vessel disease, cardiac source, other cause, dissection (ASCOD) classification the distribution of the causes of large vessel occlusion related acute ischemic stroke treated by mechanical thrombectomy. METHODS: This was a predefined substudy of the FRAME (French Acute Multimodal Imaging to Select Patient for Mechanical Thrombectomy). Each patient underwent a systematic etiological workup including brain and vascular imaging, electrocardiogram monitoring lasting at least 24 hours and routine blood tests. Stroke mechanisms were systematically evaluated using the atherosclerosis, small vessel disease, cardiac source, other cause, dissection grading system at 3 months. We defined single potential cause by one cause graded 1 in a single domain, possible cause as a cause graded 1 or 2 regardless of overlap, and no identified cause without grade 1 nor 2 causes. RESULTS: A total of 215 patients (mean age 70±14; 50% male) were included. A single potential cause was identified in 148 (69%). Cardio-embolism (53%) was the most frequent, followed by atherosclerosis (9%), dissection (5%) and other causes (1%). Atrial fibrillation accounted for 88% of C1. Overlap between grade 1 causes was uncommon (3%). Possible causes were identified in 168 patients (83%) and 16 (7%) had no cause identified after the initial evaluation. CONCLUSIONS: Cardio-embolism, especially atrial fibrillation, was the major cause of large vessel occlusion related acute ischemic stroke. This finding emphasizes the yield of paroxysmal atrial fibrillation detection in those patients. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03045146.


Assuntos
Dissecção Aórtica/complicações , Aterosclerose/complicações , Fibrilação Atrial/complicações , Embolia/complicações , AVC Isquêmico/etiologia , Idoso , Transtornos Cerebrovasculares/complicações , Feminino , Humanos , AVC Isquêmico/cirurgia , Masculino , Pessoa de Meia-Idade , Fenótipo , Trombectomia
5.
Forensic Sci Int ; 247: 126-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25575014

RESUMO

Hexagon Obti immunological blood test and flocked swab are widely used in forensic laboratories. Nevertheless, up to now, no compatibility tests have been published between sampling with the ethylene oxide treated flocked swab and the Hexagon Obti blood detection strip. In this study, we investigated this compatibility. Our work shows that sampling with ethylene oxide treated flocked swab reduces by a factor of at least 100 the detection threshold of blood using the Hexagon Obti immunological test.


Assuntos
Coleta de Amostras Sanguíneas/instrumentação , Manchas de Sangue , Óxido de Etileno , Nylons , Fitas Reagentes , Medicina Legal/instrumentação , Humanos , Testes Imunológicos/instrumentação , Masculino , Antígeno Prostático Específico/isolamento & purificação , Análise Espectral Raman
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...