Asian J Urol ; 10(3): 364-371, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37538155

RESUMO

Objective: To design a device to increase the accuracy of the targeting process and reduce the radiation exposure to both the patients and the medical staff. Methods: We analyzed the inherent problem and designed the External Assist Targeting Device (EATD) to assist in the alignment of needle targeting on the desired renal calyx under fluoroscopic guidance. The EATD was designed to allow rapid and precise access to calyces at all angles, with a simple two-step puncture protocol developed for puncturing a target renal calyx. We then tested the device in a pilot human trial with four patients. Results: In experiments with phantom models, the time for successful targeting was reduced by 31% using the device. The mean fluoroscopic time was reduced by 40%. In initial human trial, the puncture time was shortened by 66% and the radiation dose was decreased by 65% compared to free-hand technique. No complication was observed during the trial. Conclusion: The EATD was found to be cost effective, portable, simple to set up, and safe to operate for assisting in the percutaneous nephrolithotomy procedures. Our preliminary tests showed high degree of accuracy in gaining precise access to a targeted renal calyx with much shorter time and lesser radiation dose. The EATD also has the potential to be used to access other organs with precision under fluoroscopic guidance.

2.
Bioengineering (Basel) ; 5(1)2018 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-29466289

RESUMO

The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...