Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Comput Assist Radiol Surg ; 19(5): 841-849, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38704793

RESUMO

PURPOSE: Deep learning-based analysis of micro-ultrasound images to detect cancerous lesions is a promising tool for improving prostate cancer (PCa) diagnosis. An ideal model should confidently identify cancer while responding with appropriate uncertainty when presented with out-of-distribution inputs that arise during deployment due to imaging artifacts and the biological heterogeneity of patients and prostatic tissue. METHODS: Using micro-ultrasound data from 693 patients across 5 clinical centers who underwent micro-ultrasound guided prostate biopsy, we train and evaluate convolutional neural network models for PCa detection. To improve robustness to out-of-distribution inputs, we employ and comprehensively benchmark several state-of-the-art uncertainty estimation methods. RESULTS: PCa detection models achieve performance scores up to 76 % average AUROC with a 10-fold cross validation setup. Models with uncertainty estimation obtain expected calibration error scores as low as 2 % , indicating that confident predictions are very likely to be correct. Visualizations of the model output demonstrate that the model correctly identifies healthy versus malignant tissue. CONCLUSION: Deep learning models have been developed to confidently detect PCa lesions from micro-ultrasound. The performance of these models, determined from a large and diverse dataset, is competitive with visual analysis of magnetic resonance imaging, the clinical benchmark to identify PCa lesions for targeted biopsy. Deep learning with micro-ultrasound should be further studied as an avenue for targeted prostate biopsy.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias da Próstata/diagnóstico , Biópsia Guiada por Imagem/métodos , Ultrassonografia/métodos , Redes Neurais de Computação , Ultrassonografia de Intervenção/métodos
2.
Int J Comput Assist Radiol Surg ; 19(6): 1121-1128, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38598142

RESUMO

PURPOSE: The standard of care for prostate cancer (PCa) diagnosis is the histopathological analysis of tissue samples obtained via transrectal ultrasound (TRUS) guided biopsy. Models built with deep neural networks (DNNs) hold the potential for direct PCa detection from TRUS, which allows targeted biopsy and subsequently enhances outcomes. Yet, there are ongoing challenges with training robust models, stemming from issues such as noisy labels, out-of-distribution (OOD) data, and limited labeled data. METHODS: This study presents LensePro, a unified method that not only excels in label efficiency but also demonstrates robustness against label noise and OOD data. LensePro comprises two key stages: first, self-supervised learning to extract high-quality feature representations from abundant unlabeled TRUS data and, second, label noise-tolerant prototype-based learning to classify the extracted features. RESULTS: Using data from 124 patients who underwent systematic prostate biopsy, LensePro achieves an AUROC, sensitivity, and specificity of 77.9%, 85.9%, and 57.5%, respectively, for detecting PCa in ultrasound. Our model shows it is effective for detecting OOD data in test time, critical for clinical deployment. Ablation studies demonstrate that each component of our method improves PCa detection by addressing one of the three challenges, reinforcing the benefits of a unified approach. CONCLUSION: Through comprehensive experiments, LensePro demonstrates its state-of-the-art performance for TRUS-based PCa detection. Although further research is necessary to confirm its clinical applicability, LensePro marks a notable advancement in enhancing automated computer-aided systems for detecting prostate cancer in ultrasound.


Assuntos
Redes Neurais de Computação , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias da Próstata/diagnóstico , Biópsia Guiada por Imagem/métodos , Sensibilidade e Especificidade , Ultrassonografia/métodos , Aprendizado Profundo , Ultrassonografia de Intervenção/métodos
3.
Int J Comput Assist Radiol Surg ; 19(6): 1129-1136, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38600411

RESUMO

PURPOSE: Real-time assessment of surgical margins is critical for favorable outcomes in cancer patients. The iKnife is a mass spectrometry device that has demonstrated potential for margin detection in cancer surgery. Previous studies have shown that using deep learning on iKnife data can facilitate real-time tissue characterization. However, none of the existing literature on the iKnife facilitate the use of publicly available, state-of-the-art pretrained networks or datasets that have been used in computer vision and other domains. METHODS: In a new framework we call ImSpect, we convert 1D iKnife data, captured during basal cell carcinoma (BCC) surgery, into 2D images in order to capitalize on state-of-the-art image classification networks. We also use self-supervision to leverage large amounts of unlabeled, intraoperative data to accommodate the data requirements of these networks. RESULTS: Through extensive ablation studies, we show that we can surpass previous benchmarks of margin evaluation in BCC surgery using iKnife data, achieving an area under the receiver operating characteristic curve (AUC) of 81%. We also depict the attention maps of the developed DL models to evaluate the biological relevance of the embedding space CONCLUSIONS: We propose a new method for characterizing tissue at the surgical margins, using mass spectrometry data from cancer surgery.


Assuntos
Carcinoma Basocelular , Margens de Excisão , Espectrometria de Massas , Neoplasias Cutâneas , Humanos , Espectrometria de Massas/métodos , Carcinoma Basocelular/cirurgia , Carcinoma Basocelular/diagnóstico por imagem , Carcinoma Basocelular/patologia , Neoplasias Cutâneas/cirurgia , Neoplasias Cutâneas/diagnóstico por imagem , Aprendizado de Máquina Supervisionado , Aprendizado Profundo
4.
Artigo em Inglês | MEDLINE | ID: mdl-37478033

RESUMO

Deep learning-based analysis of high-frequency, high-resolution micro-ultrasound data shows great promise for prostate cancer (PCa) detection. Previous approaches to analysis of ultrasound data largely follow a supervised learning (SL) paradigm. Ground truth labels for ultrasound images used for training deep networks often include coarse annotations generated from the histopathological analysis of tissue samples obtained via biopsy. This creates inherent limitations on the availability and quality of labeled data, posing major challenges to the success of SL methods. However, unlabeled prostate ultrasound data are more abundant. In this work, we successfully apply self-supervised representation learning to micro-ultrasound data. Using ultrasound data from 1028 biopsy cores of 391 subjects obtained in two clinical centers, we demonstrate that feature representations learned with this method can be used to classify cancer from noncancer tissue, obtaining an AUROC score of 91% on an independent test set. To the best of our knowledge, this is the first successful end-to-end self-SL (SSL) approach for PCa detection using ultrasound data. Our method outperforms baseline SL approaches, generalizes well between different data centers, and scales well in performance as more unlabeled data are added, making it a promising approach for future research using large volumes of unlabeled data. Our code is publicly available at https://www.github.com/MahdiGilany/SSL_micro_ultrasound.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Ultrassonografia/métodos , Aprendizado de Máquina Supervisionado
5.
Int J Comput Assist Radiol Surg ; 18(7): 1193-1200, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37217768

RESUMO

PURPOSE: A large body of previous machine learning methods for ultrasound-based prostate cancer detection classify small regions of interest (ROIs) of ultrasound signals that lie within a larger needle trace corresponding to a prostate tissue biopsy (called biopsy core). These ROI-scale models suffer from weak labeling as histopathology results available for biopsy cores only approximate the distribution of cancer in the ROIs. ROI-scale models do not take advantage of contextual information that are normally considered by pathologists, i.e., they do not consider information about surrounding tissue and larger-scale trends when identifying cancer. We aim to improve cancer detection by taking a multi-scale, i.e., ROI-scale and biopsy core-scale, approach. METHODS: Our multi-scale approach combines (i) an "ROI-scale" model trained using self-supervised learning to extract features from small ROIs and (ii) a "core-scale" transformer model that processes a collection of extracted features from multiple ROIs in the needle trace region to predict the tissue type of the corresponding core. Attention maps, as a by-product, allow us to localize cancer at the ROI scale. RESULTS: We analyze this method using a dataset of micro-ultrasound acquired from 578 patients who underwent prostate biopsy, and compare our model to baseline models and other large-scale studies in the literature. Our model shows consistent and substantial performance improvements compared to ROI-scale-only models. It achieves [Formula: see text] AUROC, a statistically significant improvement over ROI-scale classification. We also compare our method to large studies on prostate cancer detection, using other imaging modalities. CONCLUSIONS: Taking a multi-scale approach that leverages contextual information improves prostate cancer detection compared to ROI-scale-only models. The proposed model achieves a statistically significant improvement in performance and outperforms other large-scale studies in the literature. Our code is publicly available at www.github.com/med-i-lab/TRUSFormer .


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Biópsia Guiada por Imagem/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Ultrassonografia/métodos , Pelve
6.
Int J Comput Assist Radiol Surg ; 17(12): 2305-2313, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36175747

RESUMO

PURPOSE: Rapid evaporative ionization mass spectrometry (REIMS) is an emerging technology for clinical margin detection. Deployment of REIMS depends on construction of reliable deep learning models that can categorize tissue according to its metabolomic signature. Challenges associated with developing these models include the presence of noise during data acquisition and the variance in tissue signatures between patients. In this study, we propose integration of uncertainty estimation in deep models to factor predictive confidence into margin detection in cancer surgery. METHODS: iKnife is used to collect 693 spectra of cancer and healthy samples acquired from 91 patients during basal cell carcinoma resection. A Bayesian neural network and two baseline models are trained on these data to perform classification as well as uncertainty estimation. The samples with high estimated uncertainty are then removed, and new models are trained using the clean data. The performance of proposed and baseline models, with different ratios of filtered data, is then compared. RESULTS: The data filtering does not improve the performance of the baseline models as they cannot provide reliable estimations of uncertainty. In comparison, the proposed model demonstrates a statistically significant improvement in average balanced accuracy (75.2%), sensitivity (74.1%) and AUC (82.1%) after removing uncertain training samples. We also demonstrate that if highly uncertain samples are predicted and removed from the test data, sensitivity further improves to 88.2%. CONCLUSIONS: This is the first study that applies uncertainty estimation to inform model training and deployment for tissue recognition in cancer surgery. Uncertainty estimation is leveraged in two ways: by factoring a measure of input noise in training the models and by including predictive confidence in reporting the outputs. We empirically show that considering uncertainty for model development can help improve the overall accuracy of a margin detection system using REIMS.


Assuntos
Margens de Excisão , Neoplasias , Humanos , Incerteza , Teorema de Bayes , Espectrometria de Massas/métodos , Neoplasias/diagnóstico , Neoplasias/cirurgia
7.
Int J Comput Assist Radiol Surg ; 17(5): 841-847, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35344123

RESUMO

PURPOSE: Ultrasound-guided biopsy plays a major role in prostate cancer (PCa) detection, yet is limited by a high rate of false negatives and low diagnostic yield of the current systematic, non-targeted approaches. Developing machine learning models for accurately identifying cancerous tissue in ultrasound would help sample tissues from regions with higher cancer likelihood. A plausible approach for this purpose is to use individual ultrasound signals corresponding to a core as inputs and consider the histopathology diagnosis for the entire core as labels. However, this introduces significant amount of label noise to training and degrades the classification performance. Previously, we suggested that histopathology-reported cancer involvement can be a reasonable approximation for the label noise. METHODS: Here, we propose an involvement-based label refinement (iLR) method to correct corrupted labels and improve cancer classification. The difference between predicted and true cancer involvements is used to guide the label refinement process. We further incorporate iLR into state-of-the-art methods for learning with noisy labels and predicting cancer involvement. RESULTS: We use 258 biopsy cores from 70 patients and demonstrate that our proposed label refinement method improves the performance of multiple noise-tolerant approaches and achieves a balanced accuracy, correlation coefficient, and mean absolute error of 76.7%, 0.68, and 12.4, respectively. CONCLUSIONS: Our key contribution is to leverage a data-centric method to deal with noisy labels using histopathology reports, and improve the performance of prostate cancer diagnosis through a hierarchical training process with label refinement.


Assuntos
Próstata , Neoplasias da Próstata , Humanos , Biópsia Guiada por Imagem/métodos , Aprendizado de Máquina , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...