BACKGROUND: We report on the first use of a digital 3-dimensional (3D) exoscope equipped with a 5-aminolevulinic acid (5-ALA) fluorescence visual system. METHODS: We conducted a prospective clinical trial to evaluate the utility and sensitivity/specificity of the Olympus Orbeye 3D digital exoscope when used to visualize 5-ALA-induced fluorescence in patients with high-grade glioma undergoing a clinically indicated craniotomy. At least 2 tissue samples were each obtained from regions of strong, weak. and no fluorescence and evaluated in a blinded manner by a neuropathologist. RESULTS: Twenty patients were enrolled. Intraoperative fluorescence was observed in 100% of subjects. One hundred twenty-one surgical specimens were collected for histopathological analysis; 40 with strong, 40 weak, and 41 with no visible fluorescence. Histopathology demonstrated 62.8% of samples (n = 76) contained abundant, 20.7% (n = 25) scarce, and 16.5% (n = 20) no tumor cells. Thirty-three of the 40 specimens (82.5%) in the strong fluorescence group correlated with abundant tumor cells and 7 (17.5%) with scarce. Twenty-nine of the 40 specimens (72.5%) in the weak fluorescence group correlated with abundant tumor cells, 7 (17.5%) with scarce, and 4 (10%) with none. Fourteen of the 41 (34.2%) specimens in the no fluorescence group had abundant tumor cells, 11 (26.8%) had scarce, and 16 (39%) had none. The sensitivity was 75% and specificity was 80%. The positive predictive value was 95% and negative predictive value was 39%. CONCLUSIONS: Visualization of 5-ALA-induced tumor fluorescence with use of the Orbeye 3D digital exoscope was feasible and associated with a high positive predictive value.


Assuntos
Ácido Aminolevulínico/metabolismo , Neoplasias Encefálicas/metabolismo , Glioma/metabolismo , Monitorização Intraoperatória/métodos , Imagem Óptica/métodos , Fármacos Fotossensibilizantes/metabolismo , Adulto , Idoso , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Feminino , Seguimentos , Glioma/diagnóstico por imagem , Glioma/cirurgia , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Imageamento Tridimensional/normas , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação , Monitorização Intraoperatória/normas , Gradação de Tumores/instrumentação , Gradação de Tumores/métodos , Neuronavegação/instrumentação , Neuronavegação/métodos , Neuronavegação/normas , Imagem Óptica/instrumentação , Imagem Óptica/normas , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...