Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Health Psychol ; 34(7): 775-8, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25365412

RESUMO

OBJECTIVE: Extant research has previously found several benefits of community Men's Sheds. Drawing on social identity theory, we examine the extent to which membership in Men's Sheds can influence the quality of life of Men's Sheds users. METHOD: We surveyed 322 Men's Sheds users in Australia on 4 quality of life domains and their willingness to take health advice offered at the sheds. RESULTS: Social identity was found to be a significant predictor of physical health, psychological, social relationships, and environmental domains of quality of life, as well as willingness to accept health advice. CONCLUSIONS: Our exploratory findings enrich the existing knowledge on the benefits of community men's groups. We highlight the potential importance of social identity (particularly ingroup ties) among Men's Sheds members. These initial insights may be beneficial for future research and the promotion of men's engagement with health information and practice.


Assuntos
Comportamentos Relacionados com a Saúde , Promoção da Saúde , Homens/psicologia , Qualidade de Vida/psicologia , Identificação Social , Adulto , Idoso , Idoso de 80 Anos ou mais , Austrália , Humanos , Masculino , Pessoa de Meia-Idade , Grupos Populacionais
2.
Science ; 321(5886): 217, 2008 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-18621662

RESUMO

Analysis of seismograms from a magnitude 3.9 seismic event on 6 August 2007 in central Utah reveals an anomalous radiation pattern that is contrary to that expected for a tectonic earthquake and which is dominated by an implosive component. The results show that the seismic event is best modeled as a shallow underground collapse. Interestingly, large transverse surface waves require a smaller additional noncollapse source component that might represent either faulting in the rocks above the mine workings or deformation of the medium surrounding the mine. Seismic moment tensor results for nuclear explosions, explosion and other mining cavity collapses, and tectonic earthquakes are compared, and the separation of the different populations indicates that the seismic moment tensor may be used for source-type discrimination.

3.
Anal Chem ; 75(13): 2975-84, 2003 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-12964741

RESUMO

In this manuscript, we discuss the use of photoactivated polycarbonate (PC) for purification of dye-labeled terminator sequencing fragments using solid-phase reversible immobilization (SPRI) prior to gel electrophoretic sorting of these DNAs. An immobilization bed for the DNA purification was produced by exposing a posted microchannel to UV radiation, which induced a surface photooxidation reaction, resulting in the production of carboxylate groups. The immobilization microchannel contained microposts to increase the loading level of DNAs to improve signal intensity without the need for preconcentration. By suspending the sequencing cocktail in an immobilization buffer (TEG/ethanol), the DNA fragments demonstrated a high affinity for this carboxylated surface. The loading density of DNAs to this activated surface was found to be 3.9 pmol cm(-2). The captured DNA could be subsequently released from the surface by incubation with ddH2O. SPRI cleanup of dye-terminator sequencing fragments using the photoactivated PC chip and slab gel electrophoresis produced a read length comparable to the conventional SPRI format, which utilized carboxylated magnetic beads and a magnetic field. The read length for the PC-SPRI format was found to be 620 bases with a calling accuracy of 98.9%. The PC-SPRI cleanup format was also integrated to a capillary gel electrophoresis (CGE) system. The PC-SPRI method was shown to effectively remove excess dye terminator from the CGE tract, but yielded lower plate numbers, as compared to a direct injection method with purification accomplished off-chip. The loss in efficiency was found to result primarily from the extended injection time associated with the microchip purification method.


Assuntos
DNA/isolamento & purificação , Análise de Sequência de DNA/métodos , Sequência de Bases , DNA/química , DNA de Cadeia Simples/química , DNA de Cadeia Simples/isolamento & purificação , Eletroforese Capilar/instrumentação , Eletroforese Capilar/métodos , Corantes Fluorescentes , Géis , Microquímica/métodos , Dados de Sequência Molecular , Oligodesoxirribonucleotídeos/química , Oligodesoxirribonucleotídeos/isolamento & purificação , Análise de Sequência de DNA/instrumentação , Raios Ultravioleta
4.
Anal Chem ; 74(10): 2407-15, 2002 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-12038768

RESUMO

An on-column contact conductivity detector was developed for the analysis of various mono- and polyanionic compounds separated by electrophoresis chips fabricated in poly(methyl methacrylate) (PMMA) using hot embossing techniques from Ni electroforms. The detector consisted of a pair of Pt wires (127 microm diameter) with an end-to-end spacing of approximately 20 microm and situated within the fluidic channel. The waveform applied to the electrode pair was a bipolar pulse with a frequency of 5.0 kHz and was used to reduce the charging current from measurement so that the current recorded at the end of one pulse is more representative of the solution conductivity. Using the detector, separations of amino acids, peptides, proteins, and oligonucleotides were demonstrated. For the amino acids and peptides, free-solution zone electrophoresis was performed. A calibration plot for the amino acid alanine was found to be linear from approximately 10 to 100 nM in a carrier electrolyte consisting of 10 mM triethylamonium acetate. The concentration detection limit was found to be 8.0 nM, with the corresponding mass detection limit equal to 3.4 amol (injection volume = 425 pL). The protein separations with conductivity detection were performed using MEKC, in which the carrier electrolyte contained the anionic surfactant sodium dodecyl sulfate (SDS) above its cmc. Near baseline resolution was achieved in the PMMA microchip for a solution containing 8 different proteins. In the case of the DNA fragments, capillary electrochromatography was used with a C18-modified PMMA chip and a carrier electrolyte containing an ion-pairing agent.


Assuntos
Condutividade Elétrica , Eletroforese/instrumentação , Polimetil Metacrilato , Aminoácidos/análise , Ânions/análise , Calibragem , Eletroforese/métodos , Microquímica/instrumentação , Miniaturização , Oligonucleotídeos/análise , Peptídeos/análise , Proteínas/análise
5.
Lab Chip ; 2(2): 88-95, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-15100840

RESUMO

High-aspect-ratio microstructures have been prepared using hot-embossing techniques in poly(methyl methacrylate) (PMMA) from Ni-based molding dies prepared using LIGA (Lithographie, Galvanoformung, Abformung). Due to the small amount of mask undercutting associated with X-ray lithography and the high energy X-ray beam used during photoresist patterning, deep structures with sharp and smooth sidewalls have been prepared. The Ni-electroforms produced devices with minimal replication errors using hot-embossing at a turn around time of approximately 5 min per device. In addition, several different polymers (with different glass transition temperatures) could be effectively molded with these Ni-electroforms and many devices (>300) molded with the same master without any noticeable degradation. The PMMA devices consisted of deep and narrow channels for insertion of a capillary for the automated electrokinetic loading of sample into the microfluidic device and also, a pair of optical fibers for shuttling laser light to the detection zone and collecting the resulting emission for fluorescence analysis. Electrophoretic separations of double-stranded DNA ladders Phi X174 digested with Hae III) were performed with fluorescence detection accomplished using near-IR excitation. It was found that the narrow width of the channels did not contribute significantly to electrophoretic zone broadening and the plate numbers generated in the extended length separation channel allowed sorting of the 271/281 base pair fragments associated with this sizing ladder when electrophoresed in methylcellulose entangled polymer solutions. The dual fiber detector produced sub-attomole detection limits with the entire detector, including laser source, electronics and photon transducer, situated in a single box measuring 3'' x 10" x 14".


Assuntos
Tecnologia de Fibra Óptica , Microfluídica/instrumentação , Polimetil Metacrilato/química , Espectrometria de Fluorescência/métodos , Dinitrobenzenos/isolamento & purificação , Microscopia Eletrônica de Varredura , Fibras Ópticas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...