Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
1.
J Clin Transl Endocrinol ; 36: 100352, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38860154

RESUMO

Objectives: To report the safety and side effects associated with taking verapamil for beta-cell preservation in children with newly-diagnosed T1D. Research Design and Methods: Eighty-eight participants aged 8.5 to 17.9 years weighing ≥ 30 kg were randomly assigned to verapamil (N = 47) or placebo (N = 41) within 31 days of T1D diagnosis and followed for 12 months from diagnosis, main CLVer study. Drug dosing was weight-based with incremental increases to full dosage. Side effect monitoring included serial measurements of pulse, blood pressure, liver enzymes, and electrocardiograms (ECGs). At study end, participants were enrolled in an observational extension study (CLVerEx), which is ongoing. No study drug is provided during the extension, but participants may use verapamil if prescribed by their diabetes care team. Results: Overall rates of adverse events were low and comparable between verapamil and placebo groups. There was no difference in the frequency of liver function abnormalities. Three CLVer participants reduced or discontinued medication due to asymptomatic ECG changes. One CLVerEx participant (18 years old), treated with placebo during CLVer, who had not had a monitoring ECG, experienced complete AV block with a severe hypotensive episode 6 weeks after reaching his maximum verapamil dose following an inadvertent double dose on the day of the event. Conclusions: The use of verapamil in youth newly-diagnosed with T1D appears generally safe and well tolerated with appropriate monitoring. We strongly recommend monitoring for potential side effects including an ECG at screening and an additional ECG once full dosage is reached.ClinicalTrials.gov number: NCT04233034.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38846748

RESUMO

Learning personalized self-management routines is pivotal for people with type 1 diabetes (T1D), particularly early in diagnosis. Context-aware technologies, such as hybrid closed-loop (HCL) insulin pumps, are important tools for diabetes self-management. However, clinicians have observed that practices using these technologies involve significant individual differences. We conducted interviews with 20 adolescents and young adults who use HCL insulin pump systems for managing T1D, and we found that these individuals leverage both technological and non-technological means to maintain situational awareness about their condition. We discuss how these practices serve to infrastructure their self-management routines, including medical treatment, diet, and glucose measurement-monitoring routines. Our study provides insights into adolescents' and young adults' lived experiences of using HCL systems and related technology to manage diabetes, and contributes to a more nuanced understanding of how the HCI community can support the contextualized management of diabetes through technology design.

3.
Diabetes Spectr ; 37(2): 118-123, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38756430

RESUMO

Background: Meeting glycemic recommendations is challenging for youth with type 1 diabetes. Diabetes technology, including continuous glucose monitoring (CGM) and hybrid closed-loop (HCL) automated insulin delivery systems, significantly increase achievement of glycemic targets; however, many youth struggle to sustain use of early HCL systems. Nocturnal alarm fatigue contributes to disrupted sleep and device discontinuation. Methods: We examined the frequency and causes of nocturnal (10:00 p.m. to 6:00 a.m.) alarms in pediatric patients (N = 76, median age 14.5 years [interquartile range 11.8-17.0 years, range 7-24 years]) starting on a first-generation HCL system in a prospective observational study. Device data were analyzed with linear mixed-effects models to examine change across time at 3-month intervals for 12 months. Results: At baseline (HCL system in nonautomated mode), participants averaged 3.3 ± 0.6 alarms per night. In the 2 weeks after starting HCL (automated) mode, alarm frequency significantly increased to 5.4 ± 0.5 times per night (P <0.001). Alarm frequency decreased through the remainder of the observational period; however, CGM sensor and HCL system use also declined. The types of alarms were evenly distributed among sensor maintenance, sensor threshold, pump, and HCL-specific alarms. Conclusion: These data show that HCL system nocturnal alarms are frequent and may be barriers to sleep quality and device use. Further research is needed to assess the impact of diabetes technology on sleep and to determine method to improve sleep quality with technology use.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38669472

RESUMO

In the last decade, technology developed by people with diabetes and their loved ones has added to the options for diabetes management. One such example is that of automated insulin delivery (AID) algorithms, which were created and shared as open source by people living with type 1 diabetes (T1D) years before commercial systems were first available. Now, numerous options for commercial systems exist in some countries, yet tens of thousands of people with diabetes are still choosing Open-Source AID (OS-AID), previously called "do-it-yourself" (DIY) systems, which are noncommercial versions of these open-source AID systems. In this article, we provide point and counterpoint perspectives regarding (1) safety and efficacy, (2) regulation and support, (3) user choice and flexibility, (4) access and affordability, and (5) patient and provider education, for open source and commercial AID systems. The perspectives reflected here include that of a person living with T1D who uses and has developed OS-AID systems, a physician-researcher based in the United States who conducts clinical trials to support development of commercial AID systems and supports people with diabetes using all types of AID, and an endocrinologist with T1D who uses both systems and treats people with diabetes using all types of AID.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38441904

RESUMO

Objective: Continuous glucose monitoring (CGM) devices are integral in the outpatient care of people with type 1 diabetes, although they lack inpatient labeling. Food and Drug Administration began allowing inpatient use during the coronavirus disease 2019 (COVID-19) pandemic, with some accuracy data now available, primarily from adult hospitals. Pediatric inpatient data remain limited, particularly during diabetic ketoacidosis (DKA) admissions and for patients receiving intravenous (IV) insulin. Design and Methods: This retrospective chart review compared point-of-care glucose values to personal Dexcom G6 sensor data during pediatric hospitalizations. Accuracy was assessed using mean absolute relative difference (MARD), Clarke Error Grids, and the percentage of values within 15/20/30% if glucose value >100 mg/dL and 15/20/30 mg/dL if glucose value ≤100 mg/dL. Results: Matched paired glucose values (N = 612) from 36 patients (median age 14 years, 58.3% non-Hispanic White, 47.2% male) and 42 inpatient encounters were included in this subanalysis of DKA admissions. The MARDs for DKA and non-DKA admissions (N = 503) were 11.8% and 11.7%, with 97.6% and 98.6% of pairs falling within A and B zones of the Clarke Error Grid, respectively. Severe DKA admissions (pH <7.15 and/or bicarbonate <5 mmol/L) had a MARD of 8.9% compared to 14.3% for nonsevere DKA admissions. The MARD during administration of IV insulin (N = 266) was 13.4%. Conclusions: CGM accuracy is similar between DKA and non-DKA admissions and is maintained in severe DKA and during IV insulin administration, suggesting potential usability in pediatric hospitalizations. Further study on the feasibility of implementation of CGM in the hospital is needed.

7.
Diabetes Technol Ther ; 26(S3): 7-16, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38377321

RESUMO

Background: The MiniMed™ 780G advanced hybrid closed-loop system (MM780G) builds on the basal automation and low-glucose protection features of the MiniMed™ 670G and 770G systems. While previous publications have focused on glycemic control improvements with MM780G, burden reduction has not been fully described. Methods: Data from two 3-month pivotal trials for the MM670G with Guardian™ Sensor 3 (GS3) (104 adults; 125 children) and MM780G with Guardian™ 4 Sensor (G4S) (67 adults;109 children) were compared. Real-world data (RWD) from United States users (N = 3851) transitioning from MM770G+GS3 to MM780G+G4S were also analyzed. Analyses included a new metric for diabetes management burden (i.e., pentagon composite metric), glycemic outcomes and system burden (e.g., closed-loop exits and fingersticks per day). Results: Diabetes burden metric (-22.8% and -28.5%), time in range (+3.1% [*P = 0.035] and +6.4% [P < 0.001]) and time below range (-1.8% [*P < 0.001] and -0.7% [*P < 0.001]) significantly improved, compared to MM670G for adult and pediatric participants, respectively. The pediatric mean sensor glucose (SG) reduced by -8.6 mg/dL (*P < 0.001), while the adults' saw no change. Closed-loop use significantly increased for both cohorts (+17.1% [*P < 0.001] and +20.5% [*P < 0.001]). Closed-loop exits were significantly reduced to about 1 per week (-0.5 [*P < 0.001] and -0.7 [*P < 0.001]); fingerstick tests were also reduced (-6.2 [*P < 0.001] and -6.9 [*P < 0.001]). Similar outcomes were observed from U.S. RWD. Conclusions: MiniMed™ 780G with G4S use was associated with significant reduction in diabetes management burden with fewer closed-loop exits, fingersticks and other interactions, and improvements in glycemic control when compared to the MiniMed™ 670G with GS3.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Adulto , Humanos , Criança , Hipoglicemiantes/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Glicemia , Automonitorização da Glicemia , Sistemas de Infusão de Insulina , Glucose
8.
Artigo em Inglês | MEDLINE | ID: mdl-38375861

RESUMO

Background: The Omnipod® 5 Automated Insulin Delivery System was associated with favorable glycemic outcomes for people with type 1 diabetes (T1D) in two pivotal clinical trials. Real-world evidence is needed to explore effectiveness in nonstudy conditions. Methods: A retrospective analysis of the United States Omnipod 5 System users (aged ≥2 years) with T1D and sufficient data (≥90 days of data; ≥75% of days with ≥220 continuous glucose monitor readings/day) available in Insulet Corporation's device and person-reported datasets as of July 2023 was performed. Target glucose setting usage (i.e., 110-150 mg/dL in 10 mg/dL increments) was summarized and glycemic outcomes were examined. Subgroup analyses of those using the lowest average glucose target (110 mg/dL) and stratification by baseline characteristics (e.g., age, prior therapy, health insurance coverage) were conducted. Results: In total, 69,902 users were included. Multiple and higher glucose targets were more commonly used in younger age groups. Median percentage of time in range (TIR; 70-180 mg/dL) was 68.8%, 61.3%, and 53.6% for users with average glucose targets of 110, 120, and 130-150 mg/dL, respectively, with minimal time <70 mg/dL (all median <1.13%). Among those with an average glucose target of 110 mg/dL (n = 37,640), median TIR was 65.0% in children and adolescents (2-17 years) and 69.9% in adults (≥18 years). Subgroup analyses of users transitioning from Omnipod DASH or multiple daily injections and of Medicaid/Medicare users demonstrated favorable glycemic outcomes among these groups. Conclusion: These glycemic outcomes from a large and diverse sample of nearly 70,000 children and adults demonstrate effective use of the Omnipod 5 System under real-world conditions.

9.
Diabetes Technol Ther ; 26(6): 383-393, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38277156

RESUMO

Background: To evaluate the long-term safety and effectiveness of the Omnipod® 5 Automated Insulin Delivery (AID) System in very young children with type 1 diabetes with up to 2 years of use. Methods: Following a 13-week single-arm, multicenter, pivotal trial that took place after 14 days of standard therapy data collection, participating children (2-5.9 years of age at study enrollment) were provided the option to continue use of the AID system in an extension phase. HbA1c was measured every 3 months, up to 15 months of total use, and continuous glucose monitor metrics were collected through the completion of the extension study (for up to 2 years). Results: Participants (N = 80) completed 18.2 [17.4, 23.4] (median [interquartile range]) total months of AID, inclusive of the 3-month pivotal trial. During the pivotal trial, HbA1c decreased from 7.4% ± 1.0% (57 ± 10.9 mmol/mol) to 6.9% ± 0.7% (52 ± 7.7 mmol/mol, P < 0.0001) and was maintained at 7.0% ± 0.7% (53 ± 7.7 mmol/mol) after 15 months total use (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 57.2% ± 15.3% during standard therapy to 68.1% ± 9.0% during the pivotal trial (P < 0.0001) and was maintained at 67.2% ± 9.3% during the extension phase (P < 0.0001 from standard therapy). Participants spent a median 97.1% of time in Automated Mode during the extension phase, with one episode of severe hypoglycemia and one episode of diabetic ketoacidosis. Conclusion: This evaluation of the Omnipod 5 AID System indicates that long-term use can safely maintain improvements in glycemic outcomes with up to 2 years of use in very young children with type 1 diabetes. Clinical Trials Registration Number: NCT04476472.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hemoglobinas Glicadas , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Pré-Escolar , Insulina/administração & dosagem , Insulina/uso terapêutico , Feminino , Masculino , Glicemia/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas/análise , Hipoglicemia/prevenção & controle , Resultado do Tratamento , Controle Glicêmico/métodos , Automonitorização da Glicemia
10.
Diabetes Technol Ther ; 26(2): 119-124, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38194229

RESUMO

Objective: Continuous glucose monitors (CGMs) used for type 1 diabetes management are associated with lower hemoglobin A1c. CGMs are not approved for inpatient use, when close glucose monitoring and intensive insulin management are essential for optimal health. Accuracy data from adult hospitalizations have been published, but pediatric data are limited. Design and Methods: This retrospective review of Dexcom G6 data from youth with type 1 diabetes during hospitalization assessed CGMs and matched (within 5 min) point-of-care (POC) and laboratory glucose values. Glucose values >400 and <40 mg/dL were excluded due to sensor reporting capabilities. Standard methods for CGM accuracy were used including mean absolute relative difference (MARD), Clarke Error Grids, and percentage of CGM values within 15%/20%/30% if glucose value is >100 mg/dL and 15/20/30 mg/dL if value is ≤100 mg/dL. Results: A total of 1120 POC and 288 laboratory-matched pairs were collected from 83 unique patients (median age 12.0 years, 68.7% non-Hispanic white, 54.2% male) during 100 admissions. For POC values, overall, MARD was 11.8%, that on the medical floor was 13.5%, and that in the intensive care unit was 7.9%. The MARD for all laboratory values was 6.5%. In total, 98% of matched pairs were within Clarke Error Grid A and B zones. Conclusions: Findings from our pediatric population were similar to accuracy reported in hospitalized adults, indicating the potential role for CGM use during pediatric hospitalizations. Additional research is needed to assess accuracy under various conditions, including medication use, as well as development of safe hospital protocols for successful CGM implementation for routine inpatient care.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Adolescente , Humanos , Masculino , Criança , Feminino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/complicações , Glicemia , Automonitorização da Glicemia/métodos , Pacientes Internados , Reprodutibilidade dos Testes , Hospitalização
11.
Diabetes Technol Ther ; 26(1): 11-23, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37850941

RESUMO

Background: The Omnipod® 5 Automated Insulin Delivery (AID) System was shown to be safe and effective following 3 months of use in people with type 1 diabetes (T1D); however, data on the durability of these results are limited. This study evaluated the long-term safety and effectiveness of Omnipod 5 use in people with T1D during up to 2 years of use. Materials and Methods: After a 3-month single-arm, multicenter, pivotal trial in children (6-13.9 years) and adolescents/adults (14-70 years), participants could continue system use in an extension phase. HbA1c was measured every 3 months for up to 15 months; continuous glucose monitor metrics were collected for up to 2 years. Results: Participants (N = 224) completed median (interquartile range) 22.3 (21.7, 22.7) months of AID. HbA1c was reduced in the pivotal trial from 7.7% ± 0.9% in children and 7.2% ± 0.9% in adolescents/adults to 7.0% ± 0.6% and 6.8% ± 0.7%, respectively, (P < 0.0001), and was maintained at 7.2% ± 0.7% and 6.9% ± 0.6% after 15 months (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 52.4% ± 15.6% in children and 63.6% ± 16.5% in adolescents/adults at baseline to 67.9% ± 8.0% and 73.8% ± 10.8%, respectively, during the pivotal trial (P < 0.0001) and was maintained at 65.9% ± 8.9% and 72.9% ± 11.3% during the extension (P < 0.0001 from baseline). One episode of diabetic ketoacidosis and seven episodes of severe hypoglycemia occurred during the extension. Children and adolescents/adults spent median 96.1% and 96.3% of time in Automated Mode, respectively. Conclusion: Our study supports that long-term use of the Omnipod 5 AID System can safely maintain improvements in glycemic outcomes for up to 2 years of use in people with T1D. Clinical Trials Registration Number: NCT04196140.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Criança , Humanos , Adolescente , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Hemoglobinas Glicadas , Sistemas de Infusão de Insulina , Glicemia , Automonitorização da Glicemia
12.
Diabetes Technol Ther ; 26(4): 246-251, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38133643

RESUMO

Abstract Objective: To evaluate the association between continuous glucose monitoring (CGM)-based time in various ranges and the subsequent development of diabetic retinopathy (incident DR) in adults with type 1 diabetes. Methods: Between June 2018 and March 2022, adults with type 1 diabetes with incident DR or no retinopathy (control) were identified. CGM data were collected retrospectively for up to 7 years before the date of eye examination defining incident DR or control. Associations between incident DR and CGM metrics were evaluated using logistic regression models. Results: This analysis included 71 adults with incident DR (mean age 27 years, 52% females, and mean diabetes duration 15 years) and 92 adults without DR (mean age 38 years, 48% females, and mean diabetes duration 20 years). Adjusting for age, diabetes duration, and CGM type, each 0.5% increase in glycated hemoglobin (HbA1c), 10 mg/dL increase in mean glucose, 5% decrease in time in target range 70-180 mg/dL (TIR), 5% decrease in time in tight target range 70-140 mg/dL (TITR), and 5% increase in time above 180 mg/dL (TAR) were associated with 24%, 22%, 18%, 28%, and 20% increase in odds of incident DR, respectively. Spearman correlations of TIR, TITR, TAR, and mean glucose with each other were all ≥0.97. Conclusion: Similar to HbA1c, TIR, TITR, TAR, and mean glucose were associated with increased risk for incident DR in adults with type 1 diabetes. These CGM metrics are highly correlated indicating that they provide similar information on glycemic control and diabetic retinopathy risk.


Assuntos
Diabetes Mellitus Tipo 1 , Retinopatia Diabética , Adulto , Feminino , Humanos , Masculino , Diabetes Mellitus Tipo 1/complicações , Hemoglobinas Glicadas , Glicemia , Estudos Longitudinais , Retinopatia Diabética/epidemiologia , Retinopatia Diabética/etiologia , Retinopatia Diabética/diagnóstico , Automonitorização da Glicemia/efeitos adversos , Estudos Retrospectivos
13.
Diabetes Technol Ther ; 25(11): 755-764, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37782145

RESUMO

Background: During MiniMed™ advanced hybrid closed-loop (AHCL) use by adolescents and adults in the pivotal trial, glycated hemoglobin (A1C) was significantly reduced, time spent in range (TIR) was significantly increased, and there were no episodes of severe hypoglycemia or diabetic ketoacidosis (DKA). The present study investigated the same primary safety and effectiveness endpoints during AHCL use by a younger cohort with type 1 diabetes (T1D). Methods: An intention-to-treat population (N = 160, aged 7-17 years) with T1D was enrolled in a single-arm study at 13 investigational centers. There was a run-in period (∼25 days) using HCL or sensor-augmented pump with/without predictive low-glucose management, followed by a 3-month study period with AHCL activated at two glucose targets (GTs; 100 and 120 mg/dL) for ∼45 days each. The mean ± standard deviation values of A1C, TIR, mean sensor glucose (SG), coefficient of variation (CV) of SG, time at SG ranges, and insulin delivered between run-in and study were analyzed (Wilcoxon signed-rank test or t-test). Results: Compared with baseline, AHCL use was associated with reduced A1C from 7.9 ± 0.9% (N = 160) to 7.4 ± 0.7% (N = 136) (P < 0.001) and overall TIR increased from the run-in 59.4 ± 11.8% to 70.3 ± 6.5% by end of study (P < 0.001), without change in CV, time spent below range (TBR) <70 mg/dL, or TBR <54 mg/dL. Relative to longer active insulin time (AIT) settings (N = 52), an AIT of 2 h (N = 19) with the 100 mg/dL GT increased mean TIR to 73.4%, reduced TBR <70 mg/dL from 3.5% to 2.2%, and reduced time spent above range (TAR) >180 mg/dL from 28.7% to 24.4%. During AHCL use, there was no severe hypoglycemia or DKA. Conclusions: In children and adolescents with T1D, MiniMed AHCL system use was safe, A1C was lower, and TIR was increased. The lowest GT and shortest AIT were associated with the highest TIR and lowest TBR and TAR, all of which met consensus-recommended glycemic targets. ClinicalTrials.gov ID: NCT03959423.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Hipoglicemia , Adolescente , Adulto , Criança , Humanos , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/complicações , Cetoacidose Diabética/etiologia , Glucose , Hemoglobinas Glicadas , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemia/complicações , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Resultado do Tratamento
14.
Sensors (Basel) ; 23(16)2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37631595

RESUMO

Blood glucose monitoring is an essential aspect of disease management for individuals with diabetes. Unfortunately, traditional methods require collecting a blood sample and thus are invasive and inconvenient. Recent developments in minimally invasive continuous glucose monitors have provided a more convenient alternative for people with diabetes to track their glucose levels 24/7. Despite this progress, many challenges remain to establish a noninvasive monitoring technique that works accurately and reliably in the wild. This review encompasses the current advancements in noninvasive glucose sensing technology in vivo, delves into the common challenges faced by these systems, and offers an insightful outlook on existing and future solutions.


Assuntos
Automonitorização da Glicemia , Glicemia , Humanos , Gerenciamento Clínico
15.
Pediatr Diabetes ; 20232023.
Artigo em Inglês | MEDLINE | ID: mdl-37614410

RESUMO

Background: Adolescents and young adults with type 1 diabetes have high HbA1c levels and often struggle with self-management behaviors and attention to diabetes care. Hybrid closed-loop systems (HCL) like the t:slim X2 with Control-IQ technology (Control-IQ) can help improve glycemic control. The purpose of this study is to assess adolescents' situational awareness of their glucose control and engagement with the Control-IQ system to determine significant factors in daily glycemic control. Methods: Adolescents (15-25 years) using Control-IQ participated in a 2-week prospective study, gathering detailed information about Control-IQ system engagements (boluses, alerts, and so on) and asking the participants' age and gender about their awareness of glucose levels 2-3 times/day without checking. Mixed models assessed which behaviors and awareness items correlated with time in range (TIR, 70-180 mg/dl, 3.9-10.0 mmol/L). Results: Eighteen adolescents/young adults (mean age 18 ± 1.86 years and 86% White non-Hispanic) completed the study. Situational awareness of glucose levels did not correlate with time since the last glucose check (p = 0.8). In multivariable modeling, lower TIR was predicted on days when adolescents underestimated their glucose levels (r = -0.22), received more CGM alerts (r = -0.31), and had more pump engagements (r = -0.27). A higher TIR was predicted when adolescents responded to CGM alerts (r = 0.20) and entered carbohydrates into the bolus calculator (r = 0.49). Conclusion: Situational awareness is an independent predictor of TIR and may provide insight into patterns of attention and focus that could positively influence glycemic outcomes in adolescents. Proactive engagements predict better TIR, whereas reactive engagement predicted lower TIR. Future interventions could be designed to train users to develop awareness and expertise in effective diabetes self-management.


Assuntos
Conscientização , Diabetes Mellitus Tipo 1 , Humanos , Adolescente , Adulto Jovem , Adulto , Estudos Prospectivos , Controle Glicêmico , Diabetes Mellitus Tipo 1/terapia , Glucose
16.
Diabetes Technol Ther ; 25(10): 741-751, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37471068

RESUMO

Numerous studies have demonstrated the clinical benefits of continuous glucose monitoring (CGM) in individuals with type 1 diabetes (T1D) and type 2 diabetes (T2D) who are treated with intensive insulin regimens. Based on this evidence, CGM is now a standard of care for individuals within these diabetes populations and widely covered by commercial and public insurers. Moreover, recent clinical guidelines from the American Diabetes Association and American Association of Clinical Endocrinology now endorse CGM use in individuals treated with nonintensive insulin regimens. However, despite increasing evidence supporting CGM use for individuals treated with less-intensive insulin therapy or noninsulin medications, insurance coverage is limited or nonexistent. This narrative review reports key findings from recent randomized, observational, and retrospective studies investigating use of CGM in T2D individuals treated with basal insulin only and/or noninsulin therapies and presents an evidence-based rationale for expanding access to CGM within this population.


Assuntos
Diabetes Mellitus Tipo 2 , Humanos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Glicemia , Estudos Retrospectivos , Automonitorização da Glicemia , Insulina/uso terapêutico , Insulina Regular Humana/uso terapêutico , Hipoglicemiantes/uso terapêutico
17.
Clin Diabetes ; 41(3): 386-398, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37456091

RESUMO

Despite evidence of improved diabetes outcomes with diabetes technology such as continuous glucose monitoring (CGM) systems, insulin pumps, and hybrid closed-loop (HCL) insulin delivery systems, these devices are underutilized in clinical practice for the management of insulin-requiring diabetes. This low uptake may be the result of health care providers' (HCPs') lack of confidence or time to prescribe and manage devices for people with diabetes. We administered a survey to HCPs in primary care, pediatric endocrinology, and adult endocrinology practices in the United States. Responding HCPs expressed a need for device-related insurance coverage tools and online data platforms with integration to electronic health record systems to improve diabetes technology uptake in these practice settings across the United States.

19.
Diabetes Technol Ther ; 25(9): 652-658, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37252734

RESUMO

Background: Safety and significant improvement in overall glycated hemoglobin (A1C) and percentage of time spent in (TIR), below (TBR), and above (TAR) glucose range were demonstrated in the pivotal trial of adolescents and adults using the MiniMed™ advanced hybrid closed-loop (AHCL) system with the adjunctive, calibration-required Guardian™ Sensor 3. The present study evaluated early outcomes of continued access study (CAS) participants who transitioned from the pivotal trial investigational system to the approved MiniMed™ 780G system with the non-adjunctive, calibration-free Guardian™ 4 Sensor (MM780G+G4S). Study data were presented alongside those of real-world MM780G+G4S users from Europe, the Middle East, and Africa. Methods: The CAS participants (N = 109, aged 7-17 years and N = 67, aged >17 years) used the MM780G+G4S for 3 months and data of real-world MM780G+G4S system users (N = 10,204 aged ≤15 years and N = 26,099 aged >15 years) were uploaded from September 22, 2021 to December 02, 2022. At least 10 days of real-world continuous glucose monitoring (CGM) data were required for analyses. Glycemic metrics, delivered insulin and system use/interactions underwent descriptive analyses. Results: Time in AHCL and CGM use were >90% for all groups. AHCL exits averaged 0.1/day and there were few blood glucose measurements (BGMs) (0.8/day-1.0/day). Adults in both cohorts met most consensus recommendations for glycemic targets. Pediatric groups met recommendations for %TIR and %TBR, although not those for mean glucose variability and %TAR, possibly due to low use of recommended glucose target (100 mg/dL) and active insulin time (2 h) settings (28.4% in the CAS cohort and 9.4% in the real-world cohort). The CAS pediatric and adult A1C were 7.2% ± 0.7% and 6.8% ± 0.7%, respectively, and there were no serious adverse events. Conclusions: Early clinical use of the MM780G+G4S was safe and involved minimal BGMs and AHCL exits. Consistent with real-world pediatric and adult use, outcomes were associated with achievement of recommended glycemic targets. Clinical Trial Registration number: NCT03959423.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Criança , Humanos , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose , Hemoglobinas Glicadas , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
20.
Diabetes Care ; 46(6): 1218-1222, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37023293

RESUMO

OBJECTIVE: While continuous glucose monitors (CGMs), insulin pumps, and hybrid closed-loop (HCL) systems each improve glycemic control in type 1 diabetes, it is unclear how the use of these technologies impacts real-world pediatric care. RESEARCH DESIGN AND METHODS: We found 1,455 patients aged <22 years, with type 1 diabetes duration >3 months, and who had data from a single center in between both 2016-2017 (n = 2,827) and 2020-2021 (n = 2,731). Patients were grouped by multiple daily injections or insulin pump, with or without an HCL system, and using a blood glucose monitor or CGM. Glycemic control was compared using linear mixed-effects models adjusting for age, diabetes duration, and race/ethnicity. RESULTS: CGM use increased from 32.9 to 75.3%, and HCL use increased from 0.3 to 27.9%. Overall A1C decreased from 8.9 to 8.6% (P < 0.0001). CONCLUSIONS: Adoption of CGM and HCL was associated with decreased A1C, suggesting promotion of these technologies may yield glycemic benefits.


Assuntos
Diabetes Mellitus Tipo 1 , Insulinas , Humanos , Criança , Hemoglobinas Glicadas , Etnicidade , Sistemas de Infusão de Insulina , Tecnologia , Glicemia , Automonitorização da Glicemia , Insulina , Hipoglicemiantes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...