Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 32(8): 14471-14489, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38859391

RESUMO

We propose a method to analyze the characteristics of scintillator screens for neutron imaging applications. Using calculations based on the theory of cascaded linear steps as well as experimental measurements, we compared the characteristics of different lithium- and gadolinium-based scintillator screens. Our results show that, despite their much lower light output, gadolinium-based scintillators outperform lithium-based scintillators in terms of noise characteristics for a variety of imaging setups. However, the relative performance of scintillator screens is highly dependent on the other setup characteristics such as the beam spectrum, field of view, used optical lens and size of the camera sensor. Consequently, the selection of the best scintillator screen - as well as the scintillator characteristics assessment in new developments - requires a systematic consideration of all these elements, as enabled by the framework presented here.

2.
Z Med Phys ; 14(1): 25-34, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15104007

RESUMO

PSI is still the only location in which proton therapy is applied using a dynamic beam scanning technique on a very compact gantry. Recently, this system is also being used for the application of intensity-modulated proton therapy (IMPT). This novel technical development and the success of the proton therapy project altogether have led PSI in Year 2000 to further expand the activities in this field by launching the project PROSCAN. The first step is the installation of a dedicated commercial superconducting cyclotron of a novel type. The second step is the development of a new gantry, Gantry 2. For Gantry 2 we have chosen an iso-centric compact gantry layout. The diameter of the gantry is limited to 7.5 m, less than in other gantry systems (approximately 10-12 m). The space in the treatment room is comfortably large, and the access on a fixed floor is possible any time around the patient table. Through the availability of a faster scanning system, it will be possible to treat the target volume repeatedly in the same session. For this purpose, the dynamic control of the beam intensity at the ion source and the dynamic variation of the beam energy will be used directly for the shaping of the dose.


Assuntos
Ciclotrons , Neoplasias/radioterapia , Terapia com Prótons , Radioterapia de Alta Energia/instrumentação , Radioterapia de Alta Energia/métodos , Desenho de Equipamento , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...