Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Toxicon ; 175: 19-27, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31833475

RESUMO

INTRODUCTION: Pit viper bites are a source of significant morbidity and mortality. Pit viper bites can cause venom-induced consumptive coagulopathy (VICC), typically evaluated with laboratory-based conventional coagulation tests (CCTs). However, CCTs require a laboratory and average 1 h to conduct. Thromboelastography (TEG) provides real-time, point-of-care tests of coagulation that are fast and require no separate laboratory facilities, which could be advantageous in both hospital and austere settings. However, the relative efficacy of TEG versus CCTs was unclear, particularly at low venom concentrations. Therefore, the objectives of this study were to test human blood with various concentrations of pit viper venom using CCTs and TEG to determine dose-dependent changes, lowest observed effect concentration (LOEC), and sensitivity to detecting samples out of normal diagnostic range. METHODS: Blood samples from 20 volunteers were mixed with varying concentrations of western diamond back rattlesnake (Crotalus atrox) venom based on the mouse LD50IV (none, 0.5%, 1%, 2%, 33%, 66%, and 100% LD50IV). Samples were split and assessed with both CCTs including prothrombin time (PT), international normalized ratio (INR), partial thromboplastin time (PTT), fibrinogen, and D-dimer, along with TEG measures of reaction time (R), kinetic time (K), rate of clot formation (α-angle), and clot strength (MA). Data were analyzed as dose-dependent concentration-based changes in raw values and in percent of samples exceeding diagnostic thresholds using ANOVA and nonparametric statistics at the p < .05 threshold. RESULTS: All evaluations showed significant concentration-dependent changes, and 100% of samples exceeded diagnostic thresholds at 33%LD50IV and above, save D-dimer. At 0.5%LD50IV, R, K, α-angle, PT, and INR were significantly different from controls, and at 1%LD50IV, mean values exceeded diagnostic thresholds for R, K, α-angle, MA, PT, and INR, but not for PTT, D-dimer, or fibrinogen. At 2%LD50IV, 100% of samples were out of normal range for K, α-angle, and PT. CONCLUSION: TEG is effective in coagulopathy evaluations of in vitro simulated pit viper envenomation. At low venom concentrations, TEG performed as well or better than the majority of CCTs. These findings provide empirical evidence supporting the use of TEG to rapidly and accurately evaluate VICC.


Assuntos
Testes de Coagulação Sanguínea , Crotalus , Mordeduras de Serpentes , Tromboelastografia , Animais , Humanos , Camundongos
2.
J Spec Oper Med ; 18(3): 50-56, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30222837

RESUMO

BACKGROUND: Intraosseous (IO) access is used by military first responders administering fluids, blood, and medications. Current IO transfusion strategies include gravity, pressure bags, rapid transfusion devices, and manual push-pull through a three-way stopcock. In a swine model of hemorrhagic shock, we compared flow rates among four different IO blood transfusion strategies. METHODS: Nine Yorkshire swine were placed under general anesthesia. We removed 20 to 25mL/kg of each animal's estimated blood volume using flow of gravity. IO access was obtained in the proximal humerus. We then autologously infused 10 to 15mL/kg of the animal's estimated blood volume through one of four randomly assigned treatment arms. RESULTS: The average weight of the swine was 77.3kg (interquartile range, 72.7kg-88.8kg). Infusion rates were as follows: gravity, 5mL/min; Belmont rapid infuser, 31mL/min; single-site pressure bag, 78mL/min; double-site pressure bag, 103mL/min; and push-pull technique, 109mL/min. No pulmonary arterial fat emboli were noted. CONCLUSION: The optimal IO transfusion strategy for injured Servicemembers appears to be single-site transfusion with a 10mL to 20mL flush of normal saline, followed immediately by transfusion under a pressure bag. Further study, powered to detect differences in flow rate and clinical complications. is required.


Assuntos
Transfusão de Sangue/instrumentação , Transfusão de Sangue/métodos , Choque Hemorrágico/terapia , Animais , Volume Sanguíneo , Modelos Animais de Doenças , Feminino , Gravitação , Infusões Intraósseas/métodos , Projetos Piloto , Pressão , Distribuição Aleatória , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...