Additive manufacturing is a promising technology for the rapid and economical fabrication of portable electroanalytical devices. In this paper we seek to determine how our bespoke additive manufacturing feedstocks act as the basis of an electrochemical sensing platform towards the sensing of manganese(ii) via differential pulse cathodic stripping voltammetry (DPCSV), despite the electrode comprising only 25 wt% nanographite and 75 wt% plastic (polylactic acid). The Additive Manufactured electrodes (AM-electrodes) are also critically compared to graphite screen-printed macroelectrodes (SPEs) and both are explored in model and real tap-water samples. Using optimized DPCSV conditions at pH 6.0, the analytical outputs using the AM-electrodes are as follows: limit of detection, 1.6 × 10-9 mol L-1 (0.09 µg L-1); analytical sensitivity, 3.4 µA V µmol-1 L; linear range, 9.1 × 10-9 mol L-1 to 2.7 × 10-6 mol L-1 (R2 = 0.998); and RSD 4.9% (N = 10 for 1 µmol L-1). These results are compared to screen-printed macroelectrodes (SPEs) giving comparable results providing confidence that AM-electrodes can provide the basis for useful electrochemical sensing platforms. The proposed electroanalytical method (both AM-electrodes and SPEs) is shown to be successfully applied for the determination of manganese(ii) in tap water samples and in the analysis of a certified material (drinking water). The proposed method is feasible to be applied for in-loco analyses due to the portability of sensing; in addition, the use of AM-printed electrodes is attractive due to their low cost.

3.
Nanoscale Adv ; 2(1): 264-273, 2020 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-36133988

RESUMO

Monolayer hexagonal-boron nitride films (2D-hBN) are typically reported within the literature to be electrochemically inactive due to their considerable band gap (ca. 5.2-5.8 eV). It is demonstrated herein that introducing physical linear defects (PLDs) upon the basal plane surface of 2D-hBN gives rise to electrochemically useful signatures. The reason for this transformation from insulator to semiconductor (inferred from physicochemical and computational characterisation) is likely due to full hydrogenation and oxygen passivation of the boron and/or nitrogen at edge sites. This results in a decrease in the band gap (from ca. 6.11 to 2.36/2.84 eV; theoretical calculated values, for the fully hydrogenated oxygen passivation at the N or B respectively). The 2D-hBN films are shown to be tailored through the introduction of PLDs, with the electrochemical behaviour dependent upon the surface coverage of edge plane-sites/defects, which is correlated with electrochemical performance towards redox probes (hexaammineruthenium(iii) chloride and Fe2+/3+) and the hydrogen evolution reaction. This manuscript de-convolutes, for the first time, the fundamental electron transfer properties of 2D-hBN, demonstrating that through implementation of PLDs, one can beneficially tailor the electrochemical properties of this nanomaterial.

4.
ACS Omega ; 4(11): 14439-14450, 2019 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-31528797

RESUMO

The emergence of a new class of novel psychoactive substances, N-benzyl-substituted phenethylamine derivatives so-called "NBOMes" or "Smiles", in the recreational drug market has forced the development of new sensitive analytical methodologies for their detection and quantitation. NBOMes' hallucinogenic effects mimic those of the illegal psychedelic drug lysergic acid diethylamide (LSD) and are typically sold as LSD on blotter papers, resulting in a remarkable number of fatalities worldwide. In this article, four halide derivatives of NBOMe, namely, 2-(4-fluoro-2,5-dimethoxyphenyl)-N-(2-methoxybenzyl)ethan-1-amine, 2-(4-chloro-2,5-dimethoxyphenyl)-N-(2-methoxybenzyl)ethan-1-amine, 2-(4-bromo-2,5-dimethoxyphenyl)-N-(2-methoxybenzyl)ethan-1-amine, and 2-(4-iodo-2,5-dimethoxyphenyl)-N-(2-methoxybenzyl)ethan-1-amine, were detected and quantified simultaneously using a high-performance liquid chromatographic method, and two detection systems were compared: photodiode array detection (detection system I) and amperometric detection via a commercially available impinging jet flow-cell system incorporating embedded graphite screen-printed macroelectrodes (detection system II). Under optimized experimental conditions, linear calibration plots were obtained in the concentration range of 10-300 and 20-300 µg mL-1, for detection systems I and II, respectively. Detection limit (limit of detection) values were between 4.6-6.7 and 9.7-18 µg mL-1, for detection systems I and II, respectively. Both detectors were employed for the analysis of the four NBOMe derivatives in the bulk form, in the presence of LSD and adulterants commonly found in street samples (e.g. paracetamol, caffeine, and benzocaine). Furthermore, the method was applied for the analysis of simulated blotter papers, and the obtained percentage recoveries were satisfactory, emphasizing its advantageous applicability for the routine analysis of NBOMes in forensic laboratories.

5.
Anal Chem ; 91(20): 12844-12851, 2019 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-31535844

RESUMO

Herein, we report a complete additively manufactured (AM) electrochemical sensing platform. In this approach, a fully AM/3D-printed electrochemical system, using a conventional low-cost 3D printer (fused deposition modeling) fabricating both the conductive electrodes and the nonconductive/chemically inert electrochemical cell is reported. The electrodes (working, counter, and pseudo-reference) are AM using a conductive fused-filament comprised of a mixture of carbon black nanoparticles and polylactic acid (CB/PLA). AM components partially coated with silver ink presented a similar behavior to a conventional Ag/AgCl reference electrode. The performance of the AM working electrode was evaluated after a simple and fast polishing procedure on sandpaper and electrochemical activation in a NaOH solution (0.5 mol L-1). Following the electrochemical activation step, a considerable improvement in the electrochemical behavior (current intensity and voltammetric profile) was obtained for model analytes, such as dopamine, hexaammineruthenium(III) chloride, ferricyanide/ferrocyanide, uric acid, and ascorbic acid. Excellent repeatability (RSD = 0.4%, N = 10) and limit of detection (0.1 µmol L-1) were obtained with the all complete AM electrochemical system for dopamine analysis. The electrochemical performance of the developed system (after simple electrochemical activation of the working electrode) was similar or better than those obtained using commercial glassy carbon and screen-printed carbon electrodes. The results shown here represents a significant advance in AM (3D printing) technology for analytical chemistry.

6.
Sci Rep ; 9(1): 12814, 2019 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-31492903

RESUMO

The origin of electron transfer at Chemical Vapour Deposition (CVD) grown monolayer graphene using a polymer-free transfer methodology is explored through the selective electrodeposition of Molybdenum (di)oxide (MoO2). The electrochemical decoration of CVD monolayer graphene with MoO2 is shown to originate from the edge plane like- sites/defects. Edge plane decoration of MoO2 nanowires upon monolayer graphene is observed via electrochemical deposition over short time periods only (ca. -0.6 V for 1 second (vs. Ag/AgCl)). At more electrochemically negative potentials (ca. -1.0 V) or longer deposition times, a large MoO2 film is created/deposited on the graphene sheet, originating and expanding from the original nucleation points at edge plane like- sites/defects/wrinkles. Nanowire fabrication along the edge plane like- sites/defects of graphene is confirmed with Cyclic Voltammetry, Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM) and Raman Spectroscopy. Monitoring the electrochemical response towards [Ru(NH3)6]3+/2+ and comparing the heterogeneous electron transfer (HET) kinetics at CVD grown monolayer graphene prior and post nanowire fabrication reveals key understandings into the fundamental electrochemical properties of carbon materials. The HET kinetics ([Formula: see text]) at MoO2 nanowire decorated monolayer graphene sheets, when edge plane like- sites/defects have been coated/blocked with MoO2, are significantly reduced in comparison to the unmodified graphene alternative. Interestingly, MoO2 nucleation originates on the edge plane like- sites/defects of the graphene sheets, where the basal plane sites remain unaltered until the available edge plane like- sites/defects have been fully utilised; after which MoO2 deposition propagates towards and onto the basal planes, eventually covering the entire surface of the monolayer graphene surface. In such instances, there is no longer an observable electrochemical response. This work demonstrates the distinct electron transfer properties of edge and basal plane sites on CVD grown monolayer graphene, inferring favourable electrochemical reactivity at edge plane like- sites/defects and clarifying the origin of graphene electro-activity.

7.
Sensors (Basel) ; 19(5)2019 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-30857285

RESUMO

The accurate detection of biological materials has remained at the forefront of scientific research for decades. This includes the detection of molecules, proteins, and bacteria. Biomimetic sensors look to replicate the sensitive and selective mechanisms that are found in biological systems and incorporate these properties into functional sensing platforms. Molecularly imprinted polymers (MIPs) are synthetic receptors that can form high affinity binding sites complementary to the specific analyte of interest. They utilise the shape, size, and functionality to produce sensitive and selective recognition of target analytes. One route of synthesizing MIPs is through electropolymerization, utilising predominantly constant potential methods or cyclic voltammetry. This methodology allows for the formation of a polymer directly onto the surface of a transducer. The thickness, morphology, and topography of the films can be manipulated specifically for each template. Recently, numerous reviews have been published in the production and sensing applications of MIPs; however, there are few reports on the use of electrosynthesized MIPs (eMIPs). The number of publications and citations utilising eMIPs is increasing each year, with a review produced on the topic in 2012. This review will primarily focus on advancements from 2012 in the use of eMIPs in sensing platforms for the detection of biologically relevant materials, including the development of increased polymer layer dimensions for whole bacteria detection and the use of mixed monomer compositions to increase selectivity toward analytes.


Assuntos
Técnicas Biossensoriais/métodos , Impressão Molecular/métodos , Polímeros/química , Proteínas/análise
8.
ACS Appl Mater Interfaces ; 10(50): 43669-43681, 2018 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-30489056

RESUMO

The transition-metal sulfide, CuS, is deemed a promising material for energy storage, mainly derived from its good chemisorption and conductivity, although serious capacity fading limits its advancement within reversible lithium storage. Learning from the gold extraction method utilizing the lime-sulfur-synthetic-solution, a CuS@S hybrid utilizing CaS x as both sulfur resource and reductant-oxidant is prepared, which is an efficient approach to apply the metallurgy for the preparation of electrode materials. Regulating the amount of CuCl2, the CuS@S is induced to reach a molecular-level hybrid. When utilized as an anode within a lithium-ion battery, it presents the specific capacity of 514.4 mA h g-1 at 0.1 A g-1 over 200 cycles. Supported by the analyses of pseudo-capacitive behaviors, it is confirmed that the CuS matrix with the suitable content of auxiliary sulfur could improve the durability of the CuS-based anode. Expanding the wider application within lithium-sulfur batteries, the synchronous growth of CuS@S exhibits stronger chemisorption with polysulfides than the mechanical mixture of CuS and S. A suite of in situ electrochemical impedance spectroscopy studies further investigates the stable resistances of the CuS@S within the charge/discharge process, corresponding to the reversible structure evolution. This systematic work may provide a practical fabricating route of metal sulfides for scalable energy storage applications.

9.
Adv Sci (Weinh) ; 5(7): 1800241, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30027054

RESUMO

Hierarchical nanoscale carbons have received wide interest as electrode materials for energy storage and conversion due to their fast mass transfer processes, outstanding electronic conductivity, and high stability. Here, heteroatom (S, P, and N) doped hierarchical vesicular carbon (HHVC) materials with a high surface area up to 867.5 m2 g-1 are successfully prepared using a surface polymerization of hexachloro-cyclotriphosphazene (HCCP) and 4,4'-sulfonyldiphenol (BPS) on the ZIF-8 polyhedrons. Significantly, it is the first time to achieve a controllability of the wall thickness for this unique carbon, ranging from 18 to 52 nm. When utilized as anodes for sodium ion batteries, these novel carbon materials exhibit a high specific capacity of 327.2 mAh g-1 at 100 mA g-1 after 100 cycles, which can be attributed to the expanded interlayer distance and enhanced conductivity derived from the doping of heteroatoms. Importantly, a high capacity of 142.6 mAh g-1 can be obtained even at a high current density of 5 A g-1, assigning to fast ion/electronic transmission processes stemming from the unique hierarchical vesicular structure. This work offers a new route for the fabrication/preparation of multi-heteroatom doped hierarchical vesicular materials.

10.
Biosensors (Basel) ; 8(2)2018 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-29890706

RESUMO

Screen-printed electrochemical sensing platforms, due to their scales of economy and high reproducibility, can provide a useful approach to translate laboratory-based electrochemistry into the field. An important factor when utilising screen-printed electrodes (SPEs) is the determination of their real electrochemical surface area, which allows for the benchmarking of these SPEs and is an important parameter in quality control. In this paper, we consider the use of cyclic voltammetry and chronocoulometry to allow for the determination of the real electrochemical area of screen-printed electrochemical sensing platforms, highlighting to experimentalists the various parameters that need to be diligently considered and controlled in order to obtain useful measurements of the real electroactive area.


Assuntos
Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Eletrodos/estatística & dados numéricos
11.
Analyst ; 143(14): 3360-3365, 2018 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-29893756

RESUMO

Screen-printed electrodes (SPEs) are ubiquitous with the field of electrochemistry allowing researchers to translate sensors from the laboratory to the field. In this paper, we report an electrochemically driven intercalation process where an electrochemical reaction uses an electrolyte as a conductive medium as well as the intercalation source, which is followed by exfoliation and heating/drying via microwave irradiation, and applied to the working electrode of screen-printed electrodes/sensors (termed EDI-SPEs) for the first time. This novel methodology results in an increase of up to 85% of the sensor area (electrochemically active surface area, as evaluated using an outer-sphere redox probe). Upon further investigation, it is found that an increase in the electroactive area of the EDI-screen-printed based electrochemical sensing platforms is critically dependent upon the analyte and its associated electrochemical mechanism (i.e. adsorption vs. diffusion). Proof-of-concept for the electrochemical sensing of capsaicin, a measure of the hotness of chillies and chilli sauce, within both model aqueous solutions and a real sample (Tabasco sauce) is demonstrated in which the electroanalytical sensitivity (a plot of signal vs. concentration) is doubled when utilising EDI-SPEs over that of SPEs.

12.
Analyst ; 142(19): 3674-3679, 2017 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-28836639

RESUMO

An effective electrochemical sensing platform for the simultaneous determination of benzocaine (BEN) and antipyrine (ANT) based upon titanium dioxide nanoparticle (TiO2)/graphene oxide nanosheet (GO) bulk modified carbon paste electrodes (TiO2-GO/CPE) is reported. The TiO2-GO/CPE electrochemical sensing platform is found to exhibit linear ranges from 1.0 × 10-6 to 1.0 × 10-4 M and 1.2 × 10-8 to 8.0 × 10-5 M for BEN and ANT, respectively. The TiO2-GO/CPE sensor is explored towards the analysis of BEN and ANT in oral fluid (saliva) and pharmaceutical products. The synergy between the graphene oxide nanosheets and titanium dioxide nanoparticles results in a dramatic enhancement in the sensitivity of the sensor through a combination of increased surface area and improved electron transfer kinetics compared to other electrode alternatives. The fabricated TiO2-GO/CPE exhibits high sensitivity and good stability towards the sensing of BEN and ANT and has the potential to be utilised as a clinical assay and QA in pharmaceutical products.


Assuntos
Antipirina/análise , Benzocaína/análise , Grafite/química , Nanopartículas , Titânio/química , Técnicas Eletroquímicas , Eletrodos , Óxidos
13.
Talanta ; 174: 420-427, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28738602

RESUMO

This work presents a portable electrochemical system for the continuous monitoring of corrosion inhibitors in a wide range of matrices including ethanol, seawater and mineral oil following simple dilution of the samples. Proof-of-concept is demonstrated for the sensing of 2,5-dimercapto-1,3,5-thiadiazole (DMCT), an important corrosion inhibitor. Disposable screen-printed graphitic electrodes (SPGEs) associated with a portable batch-injection cell are proposed for the amperometric determination of DMCT following sample dilution with electrolyte (95% v/v ethanol + 5% v/v 0.1molL-1 H2SO4 solution). This electrolyte was compatible with all samples and the organic-resistant SPGE could be used continuously for more than 200 injections (100µL injected at 193µLs-1) free from effects of adsorption of DMCT, which have a great affinity for metallic surfaces, and dissolution of the other reported SPGE inks which has hampered prior research efforts. Fast (180h-1) and precise responses (RSD < 3% n = 10) with a detection limit of 0.3µmolL-1 was obtained. The accuracy of the proposed method was attested through recovery tests (93-106%) and the reasonable agreement of results of DMCT concentrations in samples analyzed by both proposed and spectrophotometric (comparative) methods.

14.
Analyst ; 142(10): 1756-1764, 2017 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-28418064

RESUMO

Surfactant exfoliated 2D hexagonal Boron Nitride (2D-hBN) nanosheets are explored as a potential electrochemical sensing platform and evaluated towards the electroanalytical sensing of dopamine (DA) in the presence of the common interferents, ascorbic acid (AA) and uric acid (UA). Surfactant exfoliated 2D-hBN nanosheets (2-4 layers) fabricated using sodium cholate in aqueous media are electrically wired via a drop-casting modification process onto disposable screen-printed graphite electrodes (SPEs). We critically evaluate the performance of these 2D-hBN modified SPEs and demonstrate the effect of 'mass coverage' towards the detection of DA, AA and UA. Previous studies utilising surfactant-free (pristine) 2D-hBN modified SPEs have shown a beneficial effect towards the detection of DA, AA and UA when compared to the underlying/unmodified graphite-based electrode. We show that the fabrication route utilised to prepare 2D-hBN is a vital experimental consideration, such that the beneficial effect previously reported is considerably reduced when surfactant exfoliated 2D-hBN is utilised. We demonstrate for the first time, through implementation of control experiments in the form of surfactant modified graphite electrodes, that sodium cholate is a major contributing factor to the aforementioned detrimental behaviour. The significance here is not in the material per se, but the fundamental knowledge of the surfactant and surface coverage changing the electrochemical properties of the material under investigation. Given the wide variety of ionic and non-ionic surfactants that are utilised in the manufacture of novel 2D materials, the control experiments reported herein need to be performed in order to de-convolute the electrochemical response and effectively evaluate the 'underlying surface/surfactant/2D materials' electrocatalytic contribution.


Assuntos
Compostos de Boro/química , Dopamina/análise , Técnicas Eletroquímicas , Tensoativos/química , Ácido Ascórbico , Eletrodos , Grafite , Ácido Úrico
15.
Sci Rep ; 7: 42233, 2017 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-28256602

RESUMO

3D printing technology provides a unique platform for rapid prototyping of numerous applications due to its ability to produce low cost 3D printed platforms. Herein, a graphene-based polylactic acid filament (graphene/PLA) has been 3D printed to fabricate a range of 3D disc electrode (3DE) configurations using a conventional RepRap fused deposition moulding (FDM) 3D printer, which requires no further modification/ex-situ curing step. To provide proof-of-concept, these 3D printed electrode architectures are characterised both electrochemically and physicochemically and are advantageously applied as freestanding anodes within Li-ion batteries and as solid-state supercapacitors. These freestanding anodes neglect the requirement for a current collector, thus offering a simplistic and cheaper alternative to traditional Li-ion based setups. Additionally, the ability of these devices' to electrochemically produce hydrogen via the hydrogen evolution reaction (HER) as an alternative to currently utilised platinum based electrodes (with in electrolysers) is also performed. The 3DE demonstrates an unexpectedly high catalytic activity towards the HER (-0.46 V vs. SCE) upon the 1000th cycle, such potential is the closest observed to the desired value of platinum at (-0.25 V vs. SCE). We subsequently suggest that 3D printing of graphene-based conductive filaments allows for the simple fabrication of energy storage devices with bespoke and conceptual designs to be realised.

16.
ACS Omega ; 2(10): 6628-6635, 2017 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-30023526

RESUMO

Cesium-gold (Cs-Au) nanoparticles are shown to be analytically advantageous for the electroanalytical sensing of dapoxetine (DPX), a serotonin reuptake inhibitor used for the treatment of premature ejaculation. The Cs-Au nanoparticles are electrically wired and supported upon mass producible, economical screen-printed electrochemical sensing platforms and are characterized electrochemically (cyclic voltammetry and electrochemical impedance spectroscopy) and physiochemically (field emission scanning electron microscopy and energy dispersive X-ray analysis). The face-centered design was applied to optimize the significant experimental factors by using square wave voltammetry. The Cs-Au-based sensor is found to exhibit a large linear range (10-7 to 10-4 M) with a good analytical linearity with the limits of detection and quantification corresponding to 2.50 × 10-10 and 8.33 × 10-8 M, respectively. The developed sensor was successfully applied in the quantification of DPX in the presence of sildenafil, both of which are commonly found within combined dose tablet pharmaceutical formulations. The proposed DPX electrochemical Cs-Au-based sensor has the advantages of being single-shot and disposable and is shown to be successful in determining DPX in pharmaceutical formulations, human urine, and serum samples with acceptable recoveries.

17.
Mil Med ; 181(10): 1294-1299, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27753566

RESUMO

BACKGROUND: Many medical institutions have moved forward with curricular objectives aimed at teaching professionalism, but the question remains: are we teaching the most appropriate content at the most opportune times to maximize sustained learning? The students' point of view of professionalism is helpful in addressing this question. AIM: To describe the views of professionalism held by students and faculty at the Uniformed Services University of the Health Sciences. METHODS: In e-mailed surveys, students and faculty free-texted the three most important characteristics of a professional. Qualitative analysis was used to analyze the results. Data were compared on the basis of the percentage of each group affirming one of the characteristics. RESULTS: Fourteen characteristics of professionalism were found. There were significant differences across all participant groups in the characteristics that each indicated were most important. CONCLUSION: Differences emerge between definitions of professionalism that appear to relate to training and experience. Students' views of professionalism reflect the immediate context of their educational environment. Curricula targeted to the students' foci are relevant in teaching professionalism.


Assuntos
Atitude do Pessoal de Saúde , Currículo/tendências , Educação de Graduação em Medicina/métodos , Educação de Graduação em Medicina/normas , Profissionalismo/normas , Humanos , Assistência Centrada no Paciente/métodos , Pesquisa Qualitativa , Estudantes de Medicina/estatística & dados numéricos , Inquéritos e Questionários , Universidades/normas
18.
Biosensors (Basel) ; 6(3)2016 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-27589815

RESUMO

We explore the fabrication, physicochemical characterisation (SEM, Raman, EDX and XPS) and electrochemical application of hand-drawn pencil electrodes (PDEs) upon an ultra-flexible polyester substrate; investigating the number of draws (used for their fabrication), the pencil grade utilised (HB to 9B) and the electrochemical properties of an array of batches (i.e, pencil boxes). Electrochemical characterisation of the PDEs, using different batches of HB grade pencils, is undertaken using several inner- and outer-sphere redox probes and is critically compared to screen-printed electrodes (SPEs). Proof-of-concept is demonstrated for the electrochemical sensing of dopamine and acetaminophen using PDEs, which are found to exhibit competitive limits of detection (3σ) upon comparison to SPEs. Nonetheless, it is important to note that a clear lack of reproducibility was demonstrated when utilising these PDEs fabricated using the HB pencils from different batches. We also explore the suitability and feasibility of a pencil-drawn reference electrode compared to screen-printed alternatives, to see if one can draw the entire sensing platform. This article reports a critical assessment of these PDEs against that of its screen-printed competitors, questioning the overall feasibility of PDEs' implementation as a sensing platform.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Eletrodos , Acetaminofen/química , Dopamina/química , Eletroquímica , Reprodutibilidade dos Testes
19.
Adv Mater ; 28(42): 9391-9399, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27573868

RESUMO

Carbon dots inducing petal-like rutile TiO2 wrapped by ultrathin graphene-rich layers are proposed to fabricate superior anodes for sodium-ion batteries, featuring high-rate capabilities and long-term cyclelife, benefiting from promoted electron transport and a shortened Na+ diffusion length. High capacities of 144.4 mA h g-1 (at 837.5 mA g-1 ) after 1100 cycles and 74.6 mA h g-1 (at 3350 mA g-1 ) after 4000 cycles are delivered outstandingly.

20.
Anal Chim Acta ; 934: 1-8, 2016 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-27506338

RESUMO

This work presents the potential application of organic-resistant screen-printed graphitic electrodes (SPGEs) for fuel analysis. The required analysis of the antioxidant 2,6-di-tert-butylphenol (2,6-DTBP) in biodiesel and jet fuel is demonstrated as a proof-of-concept. The screen-printing of graphite, Ag/AgCl and insulator inks on a polyester substrate (250 µm thickness) resulted in SPGEs highly compatible with liquid fuels. SPGEs were placed on a batch-injection analysis (BIA) cell, which was filled with a hydroethanolic solution containing 99% v/v ethanol and 0.1 mol L(-1) HClO4 (electrolyte). An electronic micropipette was connected to the cell to perform injections (100 µL) of sample or standard solutions. Over 200 injections can be injected continuously without replacing electrolyte and SPGE strip. Amperometric detection (+1.1 V vs. Ag/AgCl) of 2,6-DTBP provided fast (around 8 s) and precise (RSD = 0.7%, n = 12) determinations using an external calibration curve. The method was applied for the analysis of biodiesel and aviation jet fuel samples and comparable results with liquid and gas chromatographic analyses, typically required for biodiesel and jet fuel samples, were obtained. Hence, these SPGE strips are completely compatible with organic samples and their combination with the BIA cell shows great promise for routine and portable analysis of fuels and other organic liquid samples without requiring sophisticated sample treatments.