Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
1.
Lab Chip ; 14(16): 3011-20, 2014 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-24947654

RESUMO

This paper looks at the design, fabrication and characterization of stackable microfluidic emulsion generators, with coefficients of variation as low as ~6% and with production rates as high as ~1 L h(-1). This work reports the highest throughput reported in the literature for a microfluidic device with simultaneous operation of liquid-liquid droplet generators. The device was achieved by stacking several layers of 128 flow-focusing droplet generators, organized in a circular array. These layers are interconnected via through-holes and fed with designated fractal distribution networks. The proposed layers were milled on poly(methylmethacrylate) (PMMA) sheets and the stack was thermo-compression bonded to create a three-dimensional device with a high density of generators and an integrated hydraulic manifold. The effect of stacking multiple layers was studied and the results show that fabrication accuracy has a greater impact on the dispersity of the emulsion than the addition of more layers to the stack. Particle crystallization of drugs was also demonstrated as a possible application of this technology in industry.

2.
Br J Dermatol ; 171(4): 813-8, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24814652

RESUMO

BACKGROUND: Skin protective creams (PCs) are used widely in industrial work environments to prevent irritant contact dermatitis. However, workplace studies remain equivocal in terms of their effectiveness, which may be partly owing to whether the PC remains on the skin. OBJECTIVES: To assess the practicability of using skin occlusion testing in a workplace as a method to determine whether PCs applied under controlled conditions can reduce skin damage against known irritants. This study also compares two methods of skin evaluation: clinical dermatological assessment and bioengineering techniques. METHODS: Daily occlusion testing for 1 h (over two consecutive weeks) was conducted in an engineering company on the volar forearm of 21 healthy volunteer engineers with sodium lauryl sulfate (SLS) and a PC that was used on site. The engineers conducted their normal work activities during the occlusion testing period. The skin areas tested were assessed using transepidermal water loss (TEWL), Chroma Meter and by visual dermatological scoring. RESULTS: Testing with PC and SLS together showed that PC does not prevent irritant contact dermatitis but significantly reduced skin damage compared with SLS alone (P < 0.01). The changes in skin were evident earlier with the biophysical measurements when compared with the dermatological assessment. CONCLUSIONS: Occlusion testing is a useful method for assessing the potential effectiveness of protective creams and can be used in a workplace without affecting work practices. TEWL and the Chroma Meter provide useful objective information and should be used in combination with dermatological examinations.


Assuntos
Anti-Inflamatórios/administração & dosagem , Dermatite Irritante/prevenção & controle , Dermatite Ocupacional/prevenção & controle , Fármacos Dermatológicos/administração & dosagem , Creme para a Pele/administração & dosagem , Administração Cutânea , Adulto , Combinação de Medicamentos , Interações Medicamentosas , Eritema/prevenção & controle , Humanos , Umidade , Caulim/administração & dosagem , Masculino , Pessoa de Meia-Idade , Óleos/administração & dosagem , Testes do Emplastro , Dodecilsulfato de Sódio/administração & dosagem , Tensoativos/administração & dosagem , Temperatura , Perda Insensível de Água , Ceras , Local de Trabalho
3.
Artigo em Inglês | MEDLINE | ID: mdl-19163380

RESUMO

Experiments using single cells are valuable for revealing individual cell behaviour, which is of interest to many biomedical researchers. In such experiments, various types of devices capable of aligning cells into organized arrays are often used. In this paper, we present a novel Single Cell Micro Array device that makes use of magnetic forces. Prototypes of this device have been fabricated, and successfully tested using Jurkat cells that have been labelled with nano-magnetic particles. Experimental results show that the prototypes are effective on capturing and placing the labelled cells in an array.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Algoritmos , Ligas , Materiais Biocompatíveis/química , Células Cultivadas , Simulação por Computador , Desenho de Equipamento , Humanos , Separação Imunomagnética , Células Jurkat , Magnetismo , Miniaturização , Tamanho da Partícula , Software , Fatores de Tempo
4.
Contact Dermatitis ; 55(6): 374-5, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17101022

RESUMO

We present the case of an employee of a chemical production factory who became sensitized to 2-vinylpyridine despite wearing full protective polyvinyl chloride clothing. He developed severe dermatitis at the site of contact, secondary eczematization over the flexures and periungual areas, as well as marked systemic upset. Pyridines are known sensitizers although this reaction pattern has not previously been described.


Assuntos
Alérgenos/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Ocupacional/diagnóstico , Toxidermias/diagnóstico , Piridinas/efeitos adversos , Dermatite Alérgica de Contato/etiologia , Dermatite Alérgica de Contato/patologia , Dermatite Ocupacional/etiologia , Dermatite Ocupacional/patologia , Diagnóstico Diferencial , Toxidermias/etiologia , Toxidermias/patologia , Humanos , Joelho/patologia , Masculino , Pessoa de Meia-Idade , Testes do Emplastro
5.
Br J Dermatol ; 155(4): 737-47, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16965423

RESUMO

BACKGROUND: Photoallergic contact dermatitis can be difficult to diagnose if not appropriately investigated. Currently, the most common U.K. photoallergens appear to be sunscreen chemicals. The investigation of choice is photopatch testing (PPT), which is probably underused. In part, this is due to differences in methodology and results interpretation. OBJECTIVES: To conduct PPT using a group of sunscreen chemicals, defined indications and a standardized methodology including interpretation and relevance of reactions in patients attending for investigation at 17 centres across the U.K., Ireland and the Netherlands. METHODS: Patients (n = 1155) who fulfilled the inclusion criteria were investigated with PPT using sunscreen chemicals in addition to suspected topical products. Readings were taken at 24, 48 and 72 h following standardized ultraviolet A irradiation (5 J cm(-2)). The clinical relevance of any reaction was recorded. RESULTS: Of the 1155, 130 had allergic reactions (11.3%). Of these, 51 had photoallergy (PA) (4.4%), 64 had contact allergy (CA) (5.5%), and 15 patients had combined PA and CA (1.3%). Multiple PA was seen in some. The most common photoallergen was benzophenone-3 (27 reactions; 21%). Most reactions (60%) were clinically relevant. The most common indication for testing in patients found to have PA was a history of reacting to a sunscreen (41%). The other 59% had an exposed-site dermatitis/skin problem or a photodermatosis. Some centres (n = 8) performed readings after the standard 48-h reading, and an extra 32 PA and 22 CA reactions were detected, which were not evident at 48 h. A new photoallergen (octyl triazone) was detected in two patients. CONCLUSIONS: Sunscreen PA and CA are probably equally uncommon. Most reactions, of both reaction types, were relevant clinically. A large proportion of patients (59%) found to have PA was unaware of reacting to a sunscreen chemical, suggesting that PA should be considered as an explanation in any exposed-site dermatitis. Although this study focused on reactions at 48 h postirradiation, readings performed up to 96 h, while inconvenient, add value by detecting additional relevant responses. A previously unknown photoallergen was found, highlighting the need for awareness of novel photoallergens in the marketplace. A standardized PPT method not only encourages more use of this investigation, but also facilitates comparison of results between centres and so will improve our understanding of PA.


Assuntos
Dermatite Fotoalérgica/diagnóstico , Testes do Emplastro/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Alérgenos/efeitos adversos , Criança , Pré-Escolar , Dermatite Fotoalérgica/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes do Emplastro/normas , Fatores Sexuais , Protetores Solares/efeitos adversos , Protetores Solares/química , Raios Ultravioleta/efeitos adversos
6.
Contact Dermatitis ; 55(2): 119-20, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16930241

RESUMO

We present the case of an 80-year-old lady known to be sensitive to chlorocresol (4-chloro-3-methyl phenol) who developed severe erythrodermic exfoliative dermatitis with atypical features 2 weeks after commencing subcutaneous insulin. All medications except insulin were stopped, without major improvement. It was noted that the insulin contained m-cresol (m-methyl phenol) so a parabens-based insulin was substituted. There was a significant improvement in her clinical condition within 72 hr. Further patch and intradermal testing to the insulin and m-cresol was planned, but she developed a nosocomial infection and died. We hypothesize that the adverse cutaneous reaction was a systemic manifestation of cresol sensitivity, given the rapid clinical resolution on changing insulins and the previously demonstrated sensitivity to chlorocresol, particularly as cross-reactivity between different low molecular weight methyl phenols is documented. Local injection site reactions and systemic side-effects including nausea, diarrhoea and vomiting have previously been reported with cresol-containing insulins, although to our knowledge, this is the first reported case of a severe cutaneous reaction. It is important to be aware of m-cresol as a potential allergen, as it is contained in most commercially available insulins.


Assuntos
Cresóis/efeitos adversos , Cresóis/análise , Toxidermias/etiologia , Hipoglicemiantes/química , Insulina/química , Idoso de 80 Anos ou mais , Cresóis/administração & dosagem , Feminino , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Injeções Subcutâneas , Insulina/administração & dosagem , Insulina/efeitos adversos
13.
J Appl Microbiol ; 93(5): 825-34, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12392529

RESUMO

AIMS: 5'-Nuclease (real-time, quantitative) PCR methodologies were developed and applied as diagnostic tools for the detection of microcystin-producing cyanobacteria and Escherichia coli in water. METHODS AND RESULTS: PCR was used to detect regions of the lacZ gene in E. coli, and the microcystin synthetase gene in microcystin-producing cyanobacteria. In environmental water samples, natural inhibitors to PCR were effectively removed with a prefiltration step and an EDTA wash. A lower detection limit of 10 cells ml(-1) was obtained with endpoint PCR detection. 5'-Nuclease PCR was used for microbial quantification of 1 ml inoculated water samples. We were able to detect down to three copies of our target genes per sample within about 2 h (post-DNA isolation) for both E. coli and microcystin-producing cyanobacteria. CONCLUSIONS: 5'-Nuclease PCR offers a rapid and sensitive method of bacterial quantification in water samples. SIGNIFICANCE AND IMPACT OF THE STUDY: 5'-Nuclease PCR can be adopted as an effective diagnostic tool for monitoring microbiological water quality, through coliform quantification, and detection of other waterborne microbial pathogens.


Assuntos
Cianobactérias/isolamento & purificação , Escherichia coli/isolamento & purificação , Peptídeos Cíclicos/biossíntese , Reação em Cadeia da Polimerase/métodos , Microbiologia da Água , Cianobactérias/metabolismo , DNA/análise , DNA/isolamento & purificação , Primers do DNA , Escherichia coli/genética , Escherichia coli/metabolismo , Água Doce/química , Microcistinas , Sensibilidade e Especificidade
16.
Plant J ; 27(1): 1-12, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11489178

RESUMO

Previous studies on cold-triggered events leading to Ca2+ influx during cold acclimatization have been conducted on either unicellular cyanobacterium Synechocystis or plant cell suspensions, and used transcript levels of cold-induced genes as end-point markers. Whether the results of these studies are valid for intact plants or their organs is not known. Here we examine cold signaling in transgenic Brassica napus seedlings carrying, in addition to the endogenous cold-inducible BN115 gene, the beta-glucuronidase (GUS) gene placed under control of the BN115 promoter. The activity of BN115 promoter was monitored at the transcriptional and translational levels by determining accumulation of BN115 transcripts and by histochemical assay of GUS activity. Cold-activation of BN115 was strongly inhibited by the membrane fluidizer benzyl alcohol, but mimicked at 25 degrees C by the membrane rigidifier dimethylsulfoxide (DMSO). The cold induction of BN115 was also inhibited by stabilizers of microtubules and actin microfilaments, taxol and jasplakinolide, respectively, but was mimicked at 25 degrees C by microtubule destabilizer oryzalin or colchicine, or by microfilament destabilizer latrunculin B. Gd3+ or ruthenium red prevented the cold activation of BN115, but Ca2+ ionophore A23187 or cyclic ADP-ribose activated it at 25 degrees C. Inhibitors of tyrosine kinases, protein kinase C and phosphoinositide kinases prevented the cold activation of BN115, but inhibitors of protein phosphatases (PP) 1 and 2 A activated BN115 at 25 degrees C. Constitutively expressed GUS activity in another transgenic line of the same cultivar of B. napus, was not affected by cold or any of the chemical treatments used in the experimentation. Activation of BN115 at 25 degrees C by DMSO, Ca2+ ionophore, cADPR, and by inhibitors of PP1 and 2A was accompanied by an increased freezing tolerance. It was concluded that the cold-activation of BN115 requires membrane rigidification, cytoskeleton reorganization, Ca2+ influx and action of several types of protein kinases.


Assuntos
Brassica/genética , Temperatura Baixa , Citoesqueleto/ultraestrutura , Genes de Plantas , Regiões Promotoras Genéticas , Brassica/enzimologia , Brassica/metabolismo , Cálcio/metabolismo , Membrana Celular/enzimologia , Membrana Celular/metabolismo , Membrana Celular/ultraestrutura , Citoesqueleto/enzimologia , Citoesqueleto/metabolismo , Glucuronidase/genética , Fosfoproteínas Fosfatases/antagonistas & inibidores , Plantas Geneticamente Modificadas/enzimologia , Plantas Geneticamente Modificadas/genética , Plantas Geneticamente Modificadas/metabolismo , Proteínas Quinases/metabolismo
17.
Occup Environ Med ; 58(6): 386-91, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11351054

RESUMO

OBJECTIVES: To estimate the prevalence of sensitisation to natural rubber latex in latex tappers and latex glove factory workers, and to relate this to airborne exposure to latex. METHODS: Five hundred workers employed in three latex glove factories, 314 tappers, and 144 college students (control group) were studied. The workers in the glove factories were classified into three exposure groups; high, moderate, and low. Personal exposures to natural rubber latex aeroallergens were measured by immunoassay. Symptom questionnaires and skin prick tests with latex allergens (Stallergènes 1:200 w/v) and other common environmental allergens were performed. The criterion for positivity was a wheal reaction at least 3 mm in diameter greater than that to a diluent control. RESULTS: The geometric mean (GM) concentration of latex in air was 15.4 microg/m(3) for those employed in glove stripping, glove inspections, and packing of powdered gloves. The moderate exposure glove manufacturing group and the tappers had GM concentrations of 2.3 and 2.4 microg/m(3) respectively, compared with United Kingdom users of latex powdered gloves,who had GM concentrations of 0.5 microg/m(3). The prevalence of sensitisation to latex in the tappers and latex glove factory workers was 1.3% and 1.7% respectively. No positive cases were found among the college students. Workers who showed a positive skin prick test to latex were more likely to be atopic. Work related respiratory and dermatological symptoms were found in about 20% of each population studied, but were not related to the presence of positive latex prick tests. CONCLUSIONS: This study suggests that in the Thai latex industries, latex sensitisation is rare despite high concentrations of airborne exposure and is less prevalent than in the healthcare sector in Europe where skin exposure is greater.


Assuntos
Luvas Protetoras , Hipersensibilidade ao Látex/epidemiologia , Doenças Profissionais/epidemiologia , Adulto , Poluentes Ocupacionais do Ar/análise , Alérgenos/análise , Estudos Transversais , Feminino , Humanos , Látex/análise , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional , Prevalência , Testes Cutâneos , Tailândia/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...