Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Chem Commun (Camb) ; 58(11): 1752-1755, 2022 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-35029616

RESUMO

The two-dimensional self-assembly of rufigallol derivatives and their metal coordination were studied by scanning tunnelling microscopy. Ex situ Cu(II)-coordinated rufigallol derivatives exhibited columnar structures with some defects, whereas regular and linear structures were formed upon in situ metal coordination at solid/liquid interfaces.

2.
Environ Sci Technol ; 56(2): 974-983, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-34961317

RESUMO

Firefighter turnout gear is essential for reducing occupational exposure to hazardous chemicals during training and fire events. Per-and polyfluoroalkyl substances (PFASs) are observed in firefighter serum, and possible occupational sources include the air and dust of fires, aqueous film-forming foam, and turnout gear. Limited data exist for nonvolatile and volatile PFASs on firefighter turnout gear and the disposition of fluorine on the individual layers of turnout gear. Further implications for exposure to fluorine on turnout gear are not well understood. Three unused turnout garments purchased in 2019 and one purchased in 2008, were analyzed for 50 nonvolatile and 15 volatile PFASs by liquid chromatography quadrupole time-of-flight mass spectrometry (LC-qTOF-MS) and gas chromatography-mass spectrometry (GC-MS), respectively. Particle-induced gamma ray emission (PIGE), a surface technique, and instrumental neutron activation analysis (INAA), a bulk technique, were used to measure total fluorine. Bulk characterization of the layers by pyrolysis-GC/MS (py-GC/MS) was used to differentiate fluoropolymer (e.g., PTFE) films from textile layers finished with side-chain polymers. The outer layer, moisture barrier, and thermal layers of the turnout gear all yielded measured concentrations of volatile PFASs that exceeded nonvolatile PFAS concentrations, but the summed molar concentrations made up only a small fraction of total fluorine (0.0016-6.7%). Moisture barrier layers comprised a PTFE film, as determined by py-GC-MS, and gave the highest individual nonvolatile (0.159 mg F/kg) and volatile PFAS (20.7 mg F/kg) as well as total fluorine (122,000 mg F/kg) concentrations. Outer and thermal layers comprised aromatic polyamide-based fibers (aramid) treated with side-chain fluoropolymers and had lower levels of individual nonvolatile and volatile PFASs. Equal concentrations of total fluorine by both PIGE and INAA on the outer and thermal layers is consistent with treatment with a side-chain fluoropolymer coating. New turnout gear should be examined as a potential source of firefighter occupational exposure to nonvolatile and volatile PFASs in future assessments.


Assuntos
Bombeiros , Fluorocarbonos , Exposição Ocupacional , Cromatografia Líquida , Flúor/análise , Fluorocarbonos/análise , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Exposição Ocupacional/análise
3.
Anal Chem ; 93(35): 12041-12048, 2021 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-34431672

RESUMO

Because of its speed, sensitivity, and ability to scrutinize individual species, mass spectrometry (MS) has become an essential tool in analytical strategies aimed at studying the degradation behavior of polyesters. MS analyses can be performed prior to the degradation event for structural characterization of initial substrates or after it has occurred to measure the decreasing size of products as a function of time. Here, we show that MS can also be usefully employed during the degradation process by online monitoring the chain solvolysis induced by reactive desorption electrospray ionization (DESI). Cleavage of ester bonds in random copolymers of lactic acid (LA) and glycolic acid (GA) was achieved by electrospraying methanol-containing NaOH onto the substrates. Experimental conditions were optimized to generate methanolysis products of high abundance so that mass spectra can be conveniently processed using Kendrick-based approaches. The same reactive-DESI performance was demonstrated for two sample preparations, solvent casting for soluble samples or pressed pellets for highly crystalline substrates, permitting to compare polymers with LA/GA ratios ranging from 100/0 to 5/95. Analysis of sample fractions collected by size exclusion chromatography showed that methanolysis occurs independently of the original chain size, so data recorded for poly(LA-co-GA) (PLAGA) copolymers with the average molecular weight ranging from 10 to 180 kDa could be safely compared. The average mass of methanolysis products was observed to decrease linearly (R2 = 0.9900) as the GA content increases in PLAGA substrates, consistent with the susceptibility of ester bonds toward solvolysis being higher in GA than in LA. Because DESI only explores the surface of solids, these data do not reflect bulk degradability of the copolymers but, instead, their relative degradability at the molecular level. Based on a "reactive-DESI degradability scale" such as that established here for PLAGA, the proposed method offers interesting perspectives to qualify intrinsic degradability of different polyesters and evaluate their erosion susceptibility or to determine the degradability of those polymers known to degrade via erosion only.


Assuntos
Glicóis , Espectrometria de Massas por Ionização por Electrospray , Peso Molecular , Poliésteres , Copolímero de Ácido Poliláctico e Ácido Poliglicólico
4.
J Oleo Sci ; 69(8): 871-882, 2020 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-32641614

RESUMO

In this study, an N-heterocyclic carbene (NHC)-based metal coordinate surfactant (MCS), NHC-Au-MCS, in which the NHC framework afforded the bonding of the Au(I) at the linkage of the hydrophilic and hydrophobic moieties, was synthesized. The structure of NHC-Au-MCS was confirmed by 1H and 13C NMR spectroscopic measurements together with elemental analysis. Matrix-assisted laser desorption/ionization (MALDI), laser desorption/ionization (LDI), and electrospray ionization mass spectrometry (ESI-MS) indicated the distinct reactivity of NHC-Au-MCS, such as the exchange of Br to Cl and the formation of a cationic Au complex, where the two NHC ligands were coordinated to an Au(I) center upon laser activation. The surface tension and dynamic light scattering (DLS) measurements revealed that the coordination of Au(I) to NHC reduced the critical micelle concentration (CMC) of NHC-Au-MCS (1.3×10-5 M), which resulted in the formation of micelles at concentrations higher than the CMC in water. We also confirmed that the surface-active Au(I) complex of NHC-Au-MCS catalyzed the hydration of 1-dodecyne to 2-dodecanone in water in the absence of an organic solvent. On the basis of the detailed mechanistic investigations regarding the reactivity of NHC-Au-MCS, we revealed that NHC-Au-MCS partially translated into Au nanoparticles (AuNPs), which facilitated alkyne hydration. These mechanistic studies were supported by UV-vis measurements, transmission electron microscopy (TEM), and LDI-MS.


Assuntos
Alcinos/química , Ouro/química , Compostos Heterocíclicos/síntese química , Nanopartículas Metálicas/química , Metano/análogos & derivados , Tensoativos/síntese química , Catálise , Compostos Heterocíclicos/química , Hidrogenação , Interações Hidrofóbicas e Hidrofílicas , Metano/síntese química , Metano/química , Micelas , Tensoativos/química , Água
5.
J Am Soc Mass Spectrom ; 31(7): 1554-1562, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32510219

RESUMO

An analytical methodology with mass spectrometry as the core technique was developed for precise characterization of end groups, size, and co-monomeric composition of poly(lactic-co-glycolic acid) (PLGA) copolymers, as a preliminary step to qualify their biodegradability. Four PLGA samples were studied, with GA molar content varying from 0 to 50% and Mw ranging from 18 to 75 kg mol-1 according to the supplier. Size exclusion chromatography (SEC) and liquid state nuclear magnetic resonance (NMR) were used as either complementary or validation techniques. As confirmed by tandem mass spectrometry (MS/MS) experiments, macrocycles were most prominent in the low mass range. Nevertheless, elemental compositions derived from high resolution (HR) mass measurements of linear species were consistent with chain terminations revealed by NMR. Off-line coupling of SEC with matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) permitted calibration curves to be built based on absolute molecular weights and, although slightly overestimated, so-obtained Mn and Mw values compared well with SEC and NMR results. Homogeneity of the co-monomeric content of all chains within each PLGA sample was demonstrated using surface-assisted laser desorption/ionization in a reactive mode (reactive-SALDI), a newly developed technique that takes advantage of residual acid on desorption ionization using through-hole alumina membrane (DIUTHAME) chips to induce dissociation of high-molecular-weight polymers containing cleavable C-O bonds. All HRMS data were best handled with Kendrick analysis, which helped reveal minor species and allowed automated computation of congested mass spectra.

6.
Anal Chem ; 92(11): 7399-7403, 2020 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-32437129

RESUMO

Residual acid found in the desorption ionization using through-holes alumina membranes (DIUTHAME) induces a reproducible protonation/in-source dissociation of polymers made of ester, amide, or siloxane moieties during their surface-assisted laser desorption ionization (SALDI) mass analysis. Deposited on the DIUTHAME chips in solution (solvent-based) or in pure form by melting the polymer powder in situ (solvent-free), high-molecular-weight nylons, silicone, or functionalized celluloses among other polymers are instantly fingerprinted by laser DIUTHAME high-resolution mass spectrometry (MS) with specific patterns resembling their direct analysis in real-time (DART) single-stage or tandem mass spectra. Depending on the polymer, two main types of fingerprints are observed with either the protonated monomer or product ions revealing the nature of the repeating unit or its functionalization. This technique allows a rapid molecular analysis of industrial homopolymers regardless of their molecular weight and complementary to DART with simple or no sample preparation and also promisingly applicable for copolymers.

7.
Mass Spectrom (Tokyo) ; 9(1): A0079, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32158630

RESUMO

The Kendrick analysis is used for the processing and visualization of mass spectra obtained from polymers containing C, H, O and/or Si with simple isotopic patterns (monoisotope=lightest isotope=most intense isotope for short chains). In the case of heteroatoms with complex isotopic patterns, the impact of the chosen isotope on point alignments in Kendrick plots has not been examined extensively. Rich isotopic patterns also make the evaluation of the mass and nature of the repeating unit and end-groups more difficult from the mass spectrum in the case of unknown samples due to the number of peaks and the absence of a monoisotopic peak. Using a polybrominated polycarbonate as running example, we report that horizontal point alignments can be obtained in a Kendrick plot using the mass of the most abundant isotope instead of the monoisotopic mass as is usually done. Rotating the plot ("reverse Kendrick analysis") helps to accurately evaluate the mass of the most abundant isotope of the repeating unit, as well as the nature of the brominated neutral expelled upon gentle heating (debromination or dehydrobromination). The whole procedure is then applied to the characterization of an unknown polybrominated flame retardant in an industrial formulation before and after heating.

8.
Org Biomol Chem ; 18(13): 2538, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32186572

RESUMO

Correction for 'Base-catalyzed C-alkylation of potassium enolates with styrenes via a metal-ene reaction: a mechanistic study' by Joshua P. Barham et al., Org. Biomol. Chem., 2020, DOI: 10.1039/c9ob02495f.

9.
Org Biomol Chem ; 18(11): 2063-2075, 2020 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-32100777

RESUMO

Base-catalyzed, C-alkylation of potassium (K) enolates with styrenes (CAKES) has recently emerged as a highly practical and convenient method for elaboration or synthesis of pharmaceutically-relevant cores. K enolate-type precursors such as alkyl-substituted heterocycles (pyridines, pyrazines and thiophenes), ketones, imines, nitriles and amides undergo C-alkylation reactions with styrene in the presence of KOtBu or KHMDS. Surprisingly, no studies have probed the reaction mechanism beyond the likely initial formation of a K enolate. Herein, a synergistic approach of computational (DFT), kinetic and deuterium labelling studies rationalizes various experimental observations and supports a metal-ene-type reaction for amide CAKES. Moreover, our approach explains experimental observations in other reported C-alkylation reactions of other enolate-type precursors, thus implicating a general mechanism for CAKES.

10.
J Am Soc Mass Spectrom ; 31(2): 298-307, 2020 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-32031406

RESUMO

The analysis of additives and polymers was performed by desorption ionization using through-hole alumina membrane (DIUTHAME) as a functional substrate for both sample pretreatment and surface-assisted laser desorption/ionization (SALDI) mass spectrometry. Using the unique absorbing/filtering capabilities of DIUTHAME and investigating the solubility of analytes/bulk materials in some solvents, three pretreatment techniques were demonstrated with (1) the selective removal of hydrophilic poly(ethylene oxide) (PEO)-based components from a "PEO-monostearate" sample, (2) the on-chip filtration of solubilized decabromodiphenylether (DBDE) from a solution of polystyrene that had been preliminarily precipitated, and (3) the on-chip extraction of antioxidants (Irganox 1010, Irgafos 168, and dimyristyl 3,3'-thiodipropionate) from a suspension of polypropylene powder or from the powder itself. The extracted analytes were further mass-analyzed using a spiral high-resolution time-of-flight analyzer to assess their elemental composition or molecular distribution.

11.
Nanoscale Adv ; 2(10): 4895-4901, 2020 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-36132910

RESUMO

The fabrication of supramolecularly engineered two-dimensional (2D) networks using simple molecular building blocks is an effective means for studying host-guest chemistry at surfaces toward the potential application of such systems in nanoelectronics and molecular devices. In this study, halogen-bonded molecular networks were constructed by the combination of linear halogen-bond donor and acceptor ligands, and their 2D structures at the highly oriented pyrolytic graphite/1-phenyloctane interface were studied by scanning tunneling microscopy. The bi-component blend of the molecular building blocks possessing tetradecyloxy chains formed a lozenge structure via halogen bonding. Upon the introduction of an appropriate guest molecule (e.g., coronene) into the system, the 2D structure transformed into a hexagonal array, and the central pore of this array was occupied by the guest molecules. Remarkably, the halogen bonding of the original structure was maintained after the introduction of the guest molecule. Thus, the halogen-bonded molecular networks are applicable for assembling guest species on the substrate without the requirement of the conventional rigid molecular building blocks with C 3 symmetry.

12.
Rapid Commun Mass Spectrom ; 34(5): e8597, 2020 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-31520435

RESUMO

RATIONALE: Molecular characterization of industrial oligomeric products is performed using surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS), termed desorption ionization using a through-hole alumina membrane (DIUTHAME). This paper describes the unique feature of a DIUTHAME chip applying active SALDI, which generates specific types of fragments of polyglycol samples. METHODS: Polyethylene oxide (PEO) and PEO-based materials were subjected to SALDI-MS. The influence of the presence or absence of a cationization salt on the mass spectrum was investigated. The resulting mass spectra composed of fragment ions were compared with those obtained by collision-induced dissociation (CID)-MS/MS. The specific fragment ions generated using the DIUTHAME chip were further subjected to high-energy CID-MS/MS. RESULTS: The addition of a cationization salt resulted in SALDI mass spectra with fewer fragment peaks. The mass spectra obtained without adding the cationization salt were composed of many more fragment ions caused by in-source decay. The fragmentation pattern was similar to that seen with low-energy CID. The resulting fragment ions were formed by selective cleavage at the C-O bond. High-energy CID-MS/MS can be performed for the specific fragment ions generated by in-source decay fragmentation. CONCLUSIONS: Molecular characterization of PEO-based oligomers by SALDI-MS using the DIUTHAME chip was successfully demonstrated. The selective fragmentation and high-energy CID-MS/MS of the in-source decay fragments made it possible to provide more detailed structural information. This unique feature of DIUTHAME gives it potential for use in new molecular characterization techniques.

13.
Rapid Commun Mass Spectrom ; 34 Suppl 2: e8653, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31721332

RESUMO

RATIONALE: Matrix-assisted laser desorption/ionization mass spectrometric imaging (MSI) is considered to be a powerful tool for visualizing the spatial distribution of synthetic polymers. However, a conventional method extracting an image of a specific m/z value is not suitable for polymers, which have a mass distribution. It is necessary to develop the visualization method to show the spatial distribution of entire polymer series. METHODS: The mass peaks included in polymer series were specified from the average mass spectrum of the entire MSI measurement region by using Kendrick mass defect analysis. The images of those mass peaks were extracted and the number average molecular weight (Mn ), the weight average molecular weight (Mw ) and dispersity (D) were calculated for each pixel. Finally, the spatial distribution of the polymer series was summarized to images using Mn , Mw and D as indices. RESULTS: The effects of the methods were investigated by (i) polymers with different mass distributions and (ii) polymers with different repeat units and end-groups. In both cases, the spatial distribution of specific polymer series including several dozens to hundreds of mass peaks was summarized into three images related to Mn , Mw and D, which are familiar indices in polymer analysis. The results are able to provide an overview of the spatial variation of each polymer more intuitively. CONCLUSIONS: The visualization of Mn , Mw and D will help provide an overview of the spatial distribution of polymer series combined with ion intensity distribution made by conventional methods. It can be also applied to other mass spectrometric imaging methods such as desorption electrospray ionization (DESI) or time-of-flight secondary ion mass spectrometry (TOF-SIMS).

14.
Rapid Commun Mass Spectrom ; 34 Suppl 2: e8584, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31517411

RESUMO

RATIONALE: Electrospray ionization (ESI) favors the multiple charging of high molecular weight polymer samples and allows their high-resolution mass analysis in the low-mass range. It also induces the detection of numerous ion series at different charge states with different adducts complicating the interpretation of the mass spectrum which should be facilitated by an appropriate data processing. METHODS: An arsenal of tools based on the Kendrick mass defect (KMD) is proposed to process congested ESI high-resolution mass spectra of poly(propylene oxide) (PPO) samples. The combination of regular, charge-dependent, and resolution-enhanced KMD plots in addition to a "remainders" plot and a new three-dimensional plot offers unrivaled capabilities of filtering for any minor series among thousands of points. The sequential data processing is conducted using Kendo, a spreadsheet developed in-house for an advanced KMD analysis. RESULTS: The charge-state distribution is easily evaluated by counting the parallel lines in a regular KMD plot. A charge-dependent resolution-enhanced KMD plot instantly reveals the variation of adducted ions at a given charge state, helping the user to choose the best analytical conditions. Ion series at different charge states from PPO oligomers carrying different end-groups are also efficiently extracted using several combinations of KMD and remainders plots and assigned using a new simulator tool. CONCLUSIONS: The innovative combination of existing and new KMD-related plots, selection tools, and simulator all combined in a single spreadsheet dramatically facilitates the processing and interpretation of complex ESI mass spectral data. The presented tools may be extended to any other class of homo-, co- and terpolymers.

15.
Rapid Commun Mass Spectrom ; 34 Suppl 2: e8687, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31797453

RESUMO

RATIONALE: Direct analysis in real time mass spectrometry (DART-MS) provides qualitative information about additives and polymer composition. However, the observed mass spectra are dependent on sampling conditions, in particular the DART gas temperature. This report describes the combination of a heated sample stage with DART-MS for polymer characterization. METHODS: Industrial polymers with different compositions were examined by thermal desorption and pyrolysis (TDPy) DART. Samples were heated on disposable copper stages from ambient temperature to 600°C, and the evolved gases were introduced directly into a DART ion source through a glass tee. Time- and temperature-dependent mass spectra were acquired using a high-resolution time-of-flight mass spectrometer. Kendrick mass analysis was applied to the interpretation of complex mass spectra observed for fluorinated polymers. RESULTS: Positive-ion DART mass spectra of common polymers exhibited peak series differing by monomer masses, often accompanied by a peak corresponding to the protonated monomer. Even polymers that did not exhibit a clear series of peaks produced characteristic mass spectra. Positive-ion and negative-ion mass spectra were recorded for fluorinated polymers, with polytetrafluoroethylene (PTFE) producing only negative ions. Thermal desorption provided characteristic temperature profiles for volatile species such as polymer additives and polymer pyrolysis products. CONCLUSIONS: In comparison with direct analysis by positioning sample directly in the heated DART gas stream, TDPy DART provides a more versatile sampling method and provides thermal separation and profiling of polymer additives, intact short polymer chains, and pyrolysis fragments.

16.
Anal Chem ; 92(1): 628-633, 2020 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-31801022

RESUMO

Technological advances in mass spectrometry (MS) toward more accurate and faster data acquisition result in highly informative but also more complex data sets. Especially the hyphenation of liquid chromatography (LC) and MS yields large data files containing a high amount of compound specific information. Using electrospray-ionization for compounds such as polymers enables highly sensitive detection, yet results in very complex spectra, containing multiply charged ions and adducts. Recent years have seen the development of novel or updated data mining strategies to reduce the MS spectra complexity and to ultimately simplify the data analysis workflow. Among other techniques, the Kendrick mass defect analysis, which graphically highlights compounds containing a given repeating unit, has been revitalized with applications in multiple fields of study, such as lipids and polymers. Especially for the latter, various data mining concepts have been developed, which extend regular Kendrick mass defect analysis to multiply charged ion series. The aim of this work is to collect and subsequently implement these concepts in one of the most popular open-source MS data mining software, i.e., MZmine 2, to make them rapidly available for different MS based measurement techniques and various vendor formats, with a special focus on hyphenated techniques such as LC-MS. In combination with already existing data mining modules, an example data set was processed and simplified, enabling an ever faster evaluation and polymer characterization.

17.
J Mass Spectrom ; 54(12): 933-947, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31758605

RESUMO

The mass spectrum of a polymer often displays repetitive patterns with peak series spaced by the repeating unit(s) of the polymeric backbones, sometimes complexified with different adducts, chain terminations, or charge states. Exploring the complex mass spectral data or filtering the unwanted signal is tedious whether performed manually or automatically. In contrast, the now 60-year-old Kendrick (mass defect) analysis, when adapted to polymer ions, produces visual two-dimensional maps with intuitive alignments of the repetitive patterns and favourable deconvolution of features overlaid in the one-dimensional mass spectrum. This special feature article reports on an up-to-date and theoretically sound use of Kendrick plots as a data processing tool. The approach requires no prior knowledge of the sample but offers promising dynamic capabilities for visualizing, filtering, and sometimes assigning congested mass spectra. Examples of applications of the approach to polymers are discussed throughout the text, but the same tools can be readily extended to other applications, including the analysis of polymers present as pollutants/contaminants, and to other analytes incorporating a repetitive moiety, for example, oils or lipids. In each of these instances, data processing can benefit from the application of an updated and interactive Kendrick analysis.

18.
Appl Environ Microbiol ; 85(22)2019 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-31492671

RESUMO

Glycoside hydrolase family 30 subfamily 7 (GH30-7) enzymes include various types of xylanases, such as glucuronoxylanase, endoxylanase, xylobiohydrolase, and reducing-end xylose-releasing exoxylanase. Here, we characterized the mode of action and gene expression of the GH30-7 endoxylanase from the cellulolytic fungus Talaromyces cellulolyticus (TcXyn30C). TcXyn30C has a modular structure consisting of a GH30-7 catalytic domain and a C-terminal cellulose binding module 1, whose cellulose-binding ability has been confirmed. Sequence alignment of GH30-7 xylanases exhibited that TcXyn30C has a conserved Phe residue at the position corresponding to a conserved Arg residue in GH30-7 glucuronoxylanases, which is required for the recognition of the 4-O-methyl-α-d-glucuronic acid (MeGlcA) substituent. TcXyn30C degraded both glucuronoxylan and arabinoxylan with similar kinetic constants and mainly produced linear xylooligosaccharides (XOSs) with 2 to 3 degrees of polymerization, in an endo manner. Notably, the hydrolysis of glucuronoxylan caused an accumulation of 22-(MeGlcA)-xylobiose (U4m2X). The production of this acidic XOS is likely to proceed via multistep reactions by putative glucuronoxylanase activity that produces 22-(MeGlcA)-XOSs (X n U4m2X, n ≥ 0) in the initial stages of the hydrolysis and by specific release of U4m2X from a mixture containing X n U4m2X. Our results suggest that the unique endoxylanase activity of TcXyn30C may be applicable to the production of linear and acidic XOSs. The gene xyn30C was located adjacent to the putative GH62 arabinofuranosidase gene (abf62C) in the T. cellulolyticus genome. The expression of both genes was induced by cellulose. The results suggest that TcXyn30C may be involved in xylan removal in the hydrolysis of lignocellulose by the T. cellulolyticus cellulolytic system.IMPORTANCE Xylooligosaccharides (XOSs), which are composed of xylose units with a ß-1,4 linkage, have recently gained interest as prebiotics in the food and feed industry. Apart from linear XOSs, branched XOSs decorated with a substituent such as methyl glucuronic acid and arabinose also have potential applications. Endoxylanase is a promising tool in producing XOSs from xylan. The structural variety of XOSs generated depends on the substrate specificity of the enzyme as well as the distribution of the substituents in xylan. Thus, the exploration of endoxylanases with novel specificities is expected to be useful in the provision of a series of XOSs. In this study, the endoxylanase TcXyn30C from Talaromyces cellulolyticus was characterized as a unique glycoside hydrolase belonging to the family GH30-7, which specifically releases 22-(4-O-methyl-α-d-glucuronosyl)-xylobiose from hardwood xylan. This study provides new insights into the production of linear and branched XOSs by GH30-7 endoxylanase.


Assuntos
Endo-1,4-beta-Xilanases/genética , Proteínas Fúngicas/genética , Talaromyces/enzimologia , Xilanos/metabolismo , Domínio Catalítico , Endo-1,4-beta-Xilanases/metabolismo , Proteínas Fúngicas/metabolismo , Glucuronatos/metabolismo , Hidrólise , Cinética , Oligossacarídeos/metabolismo , Especificidade por Substrato , Talaromyces/genética , Madeira/microbiologia , Xilose/metabolismo
20.
J Am Soc Mass Spectrom ; 30(7): 1321-1324, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31062289

RESUMO

Elemental compositions are commonly determined from the exact m/z of the monoisotopic peak, which is often the lightest isotope. However, the lightest isotope peak is often weak or absent and the monoisotopic peak can be difficult to identify for organometallics, polyhalogenated compounds, or large molecules. An alternative approach using the abundant isotope for elemental composition determinations is presented here.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...