Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Int J Cardiovasc Imaging ; 35(7): 1199-1210, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31053981

RESUMO

We aimed to evaluate feasibility, early healing and self-correcting properties of the Desolve 150 bioresorbable scaffold (BRS) implanted in bifurcation lesions, using the simple, provisional side branch (SB) stenting technique. BIFSORB pilot was a proof-of-concept study enrolling 10 patients with stable angina pectoris and a bifurcation lesion with SB ≥ 2.5 mm and less than 50% diameter stenosis. Procedure and 1-month outcome was evaluated by optical coherence tomography (OCT) to assess scaffold performance and healing patterns. Nine patients were treated with Desolve 150 BRS and one delivery to the target bifurcation failed. Thrombus formation in the jailed SB ostium was seen in three cases, but was completely resolved at 1-month. OCT confirmed acute self-correcting properties. No clinical events were reported after six months. Scaffold diameter by OCT increased in the proximal main vessel from 3.09 ± 0.16 mm to 3.34 ± 0.18 mm (p = 0.01) and in distal main vessel from 2.82 ± 0.26 mm to 3.02 ± 0.29 mm (p < 0.01) at one-month follow-up. SB ostial diameter stenosis improved from 42 ± 15% to 34 ± 12% (p = 0.01). Malapposition was effectively reduced after 1 month from 4.1 (1.4; 6.1)% to 0.1 (0; 0.6)% (p = 0.002). Treatment of bifurcation lesions using Desolve 150 BRS was feasible except for a delivery failure and unsettling thrombus formation behind jailing SB struts, which was completely resolved at 1-month. Self-correcting and even self-expanding properties were confirmed.


Assuntos
Implantes Absorvíveis , Angina Estável/cirurgia , Doença da Artéria Coronariana/cirurgia , Estenose Coronária/cirurgia , Vasos Coronários/cirurgia , Intervenção Coronária Percutânea/instrumentação , Cicatrização , Idoso , Angina Estável/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Projetos Piloto , Estudo de Prova de Conceito , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento
2.
Open Heart ; 6(1): e000941, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30997130

RESUMO

Objectives: We aimed to evaluate the mechanical properties and healing patterns 6 and 9 months after implantation of the sirolimus-eluting Fantom bioresorbable scaffold (BRS). Background: The Fantom BRS (Reva Medical, San Diego, USA) has differentiating properties including radiopacity, strut thickness of 125 µm, high expansion capacity and has demonstrated favourable mid-term clinical and angiographic outcomes. Methods and results: FANTOM II was a prospective, single arm study with implantation of the Fantom BRS in 240 patients with stable angina pectoris. Guidance by optical coherence tomography (OCT) was encouraged and was repeated at 6-month (cohort A) or 9-month follow-up (cohort B). Matched baseline and follow-up OCT recordings were available in 152 patients. In-scaffold mean lumen area in cohort A was 6.8±1.7 mm2 and 5.7±1.4 mm2 at baseline and follow-up (p<0.0001) and was 7.2±1.6 mm2 and 5.6±1.4 mm2 in cohort B (p<0.0001). Mean scaffold area remained stable from 7.1±1.5 mm2 at baseline to 7.2±1.4 mm2 at 6 months (p=0.12), and from 7.4±1.5 mm2 to 7.3±1.4 mm2 at 9 months. Strut malapposition was median 0.8 (IQR 0.0;3.5)% and 1.8 (IQR 0.3;6.0)% at baseline and was 0.0 (IQR 0.0;0.0)% in both groups at 6-month and 9-month follow-up. Strut tissue coverage was 98.1 (IQR 95.9;99.4)% at 6 months and 98.9 (IQR 98.3;100.0)% at 9 months. Conclusions: The novel Fantom BRS had favourable healing patterns at 6-month and 9-month follow-up as malapposition was effectively resolved and strut coverage was almost complete. The scaffold remained stable through follow-up with no signs of systematic late recoil.

3.
Circ Cardiovasc Imaging ; 11(3): e007107, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29555835

RESUMO

BACKGROUND: Quantitative flow ratio (QFR) is a novel diagnostic modality for functional testing of coronary artery stenosis without the use of pressure wires and induction of hyperemia. QFR is based on computation of standard invasive coronary angiographic imaging. The purpose of WIFI II (Wire-Free Functional Imaging II) was to evaluate the feasibility and diagnostic performance of QFR in unselected consecutive patients. METHODS AND RESULTS: WIFI II was a predefined substudy to the Dan-NICAD study (Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease), referring 362 consecutive patients with suspected coronary artery disease on coronary computed tomographic angiography for diagnostic invasive coronary angiography. Fractional flow reserve (FFR) was measured in all segments with 30% to 90% diameter stenosis. Blinded observers calculated QFR (Medis Medical Imaging bv, The Netherlands) for comparison with FFR. FFR was measured in 292 lesions from 191 patients. Ten (5%) and 9 patients (5%) were excluded because of FFR and angiographic core laboratory criteria, respectively. QFR was successfully computed in 240 out of 255 lesions (94%) with a mean diameter stenosis of 50±12%. Mean difference between FFR and QFR was 0.01±0.08. QFR correctly classified 83% of the lesions using FFR with cutoff at 0.80 as reference standard. The area under the receiver operating characteristic curve was 0.86 (95% confidence interval, 0.81-0.91) with a sensitivity, specificity, negative predictive value, and positive predictive value of 77%, 86%, 75%, and 87%, respectively. A QFR-FFR hybrid approach based on the present results enables wire-free and adenosine-free procedures in 68% of cases. CONCLUSIONS: Functional lesion evaluation by QFR assessment showed good agreement and diagnostic accuracy compared with FFR. Studies comparing clinical outcome after QFR- and FFR-based diagnostic strategies are required. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02264717.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Imageamento Tridimensional/métodos , Telemedicina/métodos , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...