Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Front Neurol ; 14: 1247421, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37727579

RESUMO

Purpose: Given the inherent complexity of neurointerventional procedures and the associated risks of ionizing radiation exposure, it is crucial to prioritize ongoing training and improve safety protocols. The aim of this study is to assess a training and evaluation in-vitro environment using a vascular model of M1 stenosis, within a clinical angiography suite, without relying on animal models or X-ray radiation. Materials and methods: Using a transparent model replicating M1 stenosis, we conducted intracranial stenting procedures with four different setups (Gateway & Wingspan, Gateway & Enterprise, Neurospeed & Acclino, and Pharos Vitesse). A video camera was integrated with the angiography system's monitor for real-time visualization, while a foot switch was employed to simulate live fluoroscopy. Three neuroradiologists with varying levels of expertise performed each procedure for three times. The total duration of fluoroscopy as well as the time from passing the stenosis with the wire to completion of the procedure were recorded using a dedicated software designed for this experimental setup. Results: Compared to the Gateway & Wingspan procedure, the total fluoroscopy time reduced significantly with the Gateway & Enterprise, Neurospeed & Acclino, and Pharos Vitesse procedures by 51.56 s, 111.33 s, and 144.89 s, respectively (p < 0.001). Additionally, physicians with under 2 years and over 5 years of experience reduced FT by 62.83 s and 106.42 s, respectively, (p < 0.001), compared to a novice physician. Similar trends were noted for the time of wire distal to stenosis, with significant reductions for Neurospeed & Acclino and Pharos Vitesse compared to both Gateway & Wingspan as well as Gateway & Enterprise (all p < 0.001). Conclusion: Procedures requiring wire exchange maneuvers exhibited nearly twice the fluoroscopy time in comparison to balloon-mounted stenting or stent-placement via PTA balloon catheters. The more experienced neuroradiologist demonstrated significantly quicker performance in line with expectations in a real-life clinical setting, when compared to the less experienced interventionalist. This in-vitro setup allowed the evaluation of alternative technical approaches and differences in experience of operators without the use of animal models or X-ray. The setup combines advantages of simulators and silicone vessel models in a realistic working environment.

2.
ERJ Open Res ; 9(5)2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37753274

RESUMO

Background: Interstitial lung abnormalities (ILA) are incidental findings on chest computed tomography (CT). These patterns can present at an early stage of fibrotic lung disease. Our aim was to estimate the prevalence of ILA in the Swedish population, in particular in never-smokers, and find out its association with demographics, comorbidities and symptoms. Methods: Participants were recruited to the Swedish CArdioPulmonary BioImage Study (SCAPIS), a population-based survey including men and women aged 50-64 years performed at six university hospitals in Sweden. CT scan, spirometry and questionnaires were performed. ILA were defined as cysts, ground-glass opacities, reticular abnormality, bronchiectasis and honeycombing. Findings: Out of 29 521 participants, 14 487 were never-smokers and 14 380 were men. In the whole population, 2870 (9.7%) had ILA of which 134 (0.5%) were fibrotic. In never-smokers, the prevalence was 7.9% of which 0.3% were fibrotic. In the whole population, age, smoking history, chronic bronchitis, cancer, coronary artery calcium score and high-sensitive C-reactive protein were associated with ILA. Both ILA and fibrotic ILA were associated with restrictive spirometric pattern and impaired diffusing capacity of the lung for carbon monoxide. However, individuals with ILA did not report more symptoms compared with individuals without ILA. Interpretation: ILA are common in a middle-aged Swedish population including never-smokers. ILA may be at risk of being underdiagnosed among never-smokers since they are not a target for screening.

3.
PLoS One ; 17(9): e0274211, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36083986

RESUMO

PURPOSE: The increased demand for training of mechanical thrombectomy in ischemic stroke and development of new recanalization devices urges the creation of new simulation models both for training and device assessment. Clots properties have shown to play a role in procedural planning and thrombectomy device effectiveness. In this study, we analyzed the characteristics and applicability of completely synthetic, animal-free clots in the setting of an in-vitro model of mechanical thrombectomy for training and device assessment. METHODS: Synthetic clots based on agarose (n = 12) and silicone (n = 11) were evaluated in an in-vitro neurointervention simulation of mechanical thrombectomy with clot extraction devices. Calcified clots of mixed nature were simulated with addition of 3D printed structures. 9 clots were excluded due to insufficient vessel occlusion and failure to integrate with clot extraction device. Synthetic thrombi were characterized and compared using a categorical score-system on vessel occlusion, elasticity, fragmentation, adherence and device integration. RESULTS: Both agarose-based and silicone-based clots demonstrated relevant flow arrest and a good integration with the clot extraction device. Silicone-based clots scored higher on adherence to the vessel wall and elasticity. CONCLUSION: Selected synthetic clots can successfully be implemented in an in-vitro training environment of mechanical thrombectomy. The clots' different properties might serve to mimic fibrin-rich and red blood cell-rich human thrombi.


Assuntos
Acidente Vascular Cerebral , Trombose , Humanos , Sefarose , Silicones , Acidente Vascular Cerebral/terapia , Trombectomia , Resultado do Tratamento
4.
Stroke ; 52(11): 3497-3504, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34496622

RESUMO

Background and Purpose: Mechanical thrombectomy is an established procedure for treatment of acute ischemic stroke. Mechanical thrombectomy success is commonly assessed by the Thrombolysis in Cerebral Infarction (TICI) score, assigned by visual inspection of X-ray digital subtraction angiography data. However, expert-based TICI scoring is highly observer-dependent. This represents a major obstacle for mechanical thrombectomy outcome comparison in, for instance, multicentric clinical studies. Focusing on occlusions of the M1 segment of the middle cerebral artery, the present study aimed to develop a deep learning (DL) solution to automated and, therefore, objective TICI scoring, to evaluate the agreement of DL- and expert-based scoring, and to compare corresponding numbers to published scoring variability of clinical experts. Methods: The study comprises 2 independent datasets. For DL system training and initial evaluation, an in-house dataset of 491 digital subtraction angiography series and modified TICI scores of 236 patients with M1 occlusions was collected. To test the model generalization capability, an independent external dataset with 95 digital subtraction angiography series was analyzed. Characteristics of the DL system were modeling TICI scoring as ordinal regression, explicit consideration of the temporal image information, integration of physiological knowledge, and modeling of inherent TICI scoring uncertainties. Results: For the in-house dataset, the DL system yields Cohen's kappa, overall accuracy, and specific agreement values of 0.61, 71%, and 63% to 84%, respectively, compared with the gold standard: the expert rating. Values slightly drop to 0.52/64%/43% to 87% when the model is, without changes, applied to the external dataset. After model updating, they increase to 0.65/74%/60% to 90%. Literature Cohen's kappa values for expert-based TICI scoring agreement are in the order of 0.6. Conclusions: The agreement of DL- and expert-based modified TICI scores in the range of published interobserver variability of clinical experts highlights the potential of the proposed DL solution to automated TICI scoring.


Assuntos
Infarto Cerebral/patologia , Aprendizado Profundo , Interpretação de Imagem Assistida por Computador/métodos , Neuroimagem/métodos , Angiografia Digital , Infarto Cerebral/terapia , Humanos , Estudo de Prova de Conceito , Trombectomia
5.
J Neurointerv Surg ; 13(8): 722-726, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32883781

RESUMO

BACKGROUND: In large vessel occlusionstroke, navigation of aspiration catheters (AC) can be impeded by vessel tortuosity and the ophthalmic artery origin. A novel tapered delivery catheter was designed to facilitate delivery without disturbing the embolus. We assessed AC deliverability in vitro and validated the observations in a first-in-human experience. METHODS: In a vascular model with three challenging craniocervical scenarios, two commercial AC were advanced from the carotid to the middle cerebral artery by four neurointerventionalists. Catheter deliverability with standard microwire and microcatheter (MC) combinations and the Tenzing 7 (T7) Delivery Catheter (Route 92 Medical, San Mateo, CA) were compared. Operators rated aspects of catheter deliverability on a 5-point scale. Results were compared with device delivery patterns at a neurovascular center before and after clinical introduction of T7. RESULTS: In vitro, success rate and speed were higher with T7 (96%; mean 30±10 s) than with MC (65%; 72±47 s, p<0.001 each), with fewer interactions with the occlusion site (T7: 54% vs MC: 77%, p=0.004). T7 received superior ratings regarding carotid artery deflection (T7: 2, IQR1-3 vs MC: 3, IQR2-3, p<0.001), guide catheter pushback (T7: 2, IQR1-3 vs MC: 3, IQR3-3, p<0.001) and ophthalmic artery passage (T7: 1.5, IQR1-2 vs MC: 4, IQR3-5, p<0.001). Before introduction of T7 at a single center, delivery of AC to a large vessel occlusion without crossing was achieved in 15/123 cases (12%). With T7, this rate was 28/31 patients (90.3%). CONCLUSION: Compared with microcatheter and microwire combinations, T7 improves aspiration catheter delivery in vitro, minimizing the need to cross the occlusion. Initial clinical experience appears to validate the model's observations.


Assuntos
Artérias Carótidas/cirurgia , Catéteres , Revascularização Cerebral , Desenho de Equipamento , Embolia Intracraniana , AVC Isquêmico , Artéria Cerebral Média/cirurgia , Trombectomia , Revascularização Cerebral/instrumentação , Revascularização Cerebral/métodos , Humanos , Embolia Intracraniana/complicações , Embolia Intracraniana/cirurgia , AVC Isquêmico/etiologia , AVC Isquêmico/cirurgia , Teste de Materiais/métodos , Estudos Retrospectivos , Trombectomia/instrumentação , Trombectomia/métodos , Resultado do Tratamento
6.
Clin Neuroradiol ; 31(1): 181-187, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31863121

RESUMO

PURPOSE: Stroke patients are excluded from expeditious thrombectomy in regions lacking neurointerventional specialists. An audiovisual online streaming system was tested, allowing a neurointerventional specialist located at a neurovascular center to supervise and instruct a thrombectomy performed at a distant hospital without being physically present (remote streaming support [RESS]). METHODS: In total, 36 thrombectomy procedures were performed on a Mentice endovascular simulator by six radiologists not specialized in neurointerventions. Each radiologist was challenged with six different endovascular simulation scenarios under alternating conventional local support (specialist inside the room [LOS]) and RESS, which was performed using an advanced live streaming platform. RESULTS: Both support modes led to a median of 2 attempts (interquartile range [IQR] 2.0-2.0 each) until successful recanalization. There was no statistically significant difference in time from first catheter insertion to recanalization between LOS (median 24.9 min, IQR 21.0-31.5 min) and RESS (23.9 min, IQR 21.7-28.7 min, p = 0.89). The percentage of thrombi covered by the stent-retriever and average speed when retrieving the stent-retriever (3.7 mm/s, IQR 3.25-5.35 mm/s vs. 3.6 mm/sec, IQR 2.5-4.7) were similar in both groups. Fluoroscopy time did not differ (19.0 min, IQR 16.9-23.5 min vs. 19.9 min, IQR 15.9-23.5 min) with a trend towards increased median amounts of contrast medium used under RESS (62.9 ml vs. 43.1 ml; p = 0.055). CONCLUSION: This study confirmed the feasibility of RESS for thrombectomy procedures in a simulated environment. This serves as basis for future studies planned to analyze the effectiveness of RESS in a real-world environment and to test if it improves the learning curve of interventionalists with limited thrombectomy experience in remote areas.


Assuntos
Isquemia Encefálica , Procedimentos Endovasculares , Acidente Vascular Cerebral , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/cirurgia , Humanos , Estudos Retrospectivos , Stents , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia , Resultado do Tratamento
7.
J Neurointerv Surg ; 13(7): 605-608, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32753556

RESUMO

BACKGROUND: A direct aspiration first pass technique (ADAPT) is an efficient, safe, cost-effective, and fast thrombectomy technique. OBJECTIVE: To evaluate anatomical and clot characteristics associated with success of the aspiration component as part of ADAPT. METHODS: 106 cases of acute carotid-T, basilar, and middle cerebral artery occlusion undergoing endovascular treatment with ADAPT were retrospectively assessed for successful catheter-clot contact and successful primary aspiration, defined as a Thrombolysis in Cerebral Infarction score ≥2b after primary aspiration with 5F or 6F aspiration catheters. Patient age, National Institutes of Health Stroke Scale (NIHSS) score, time from symptom onset to groin puncture, time from groin puncture to revascularization, aortic arch type, access vessel tortuosity, vessel diameter at the proximal end of the thrombus, catheter-to-vessel ratio (CVR), clot density, length, and perviousness were determined. RESULTS: Successful clot contact with the aspiration catheter was achieved in 76 cases (72%); these patients were younger (67.7±15.2 vs 73.7±11.4 years; p=0.05) and had less tortuous access vessels (1 vs 2 reverse curves; p=0.004) than those in whom clot contact failed. Successful primary aspiration occurred in 36 of these cases (47%) and was associated with significantly smaller vessel diameter at the proximal thrombus end (2.5±0.7 mm vs 3.1±1.3 mm; p=0.01) and higher CVR (CVR outer diameter: 0.85±0.2 vs 0.68±0.2; p=0.01 and CVR inner diameter: 0.72±0.2 vs 0.58±0.2; p<0.001). No significant differences were seen in aortic arch type, radiographic clot features, and NIHSS score. CONCLUSION: With ADAPT, patient age and vessel tortuosity affect the ability to deliver the aspiration catheter and achieve clot contact, whereas vessel diameter and CVR at the aspiration site seem to affect the effectiveness of clot aspiration. Strategies aimed at improving catheter deliverability and increasing CVR may increase the efficacy of ADAPT.


Assuntos
Catéteres , Infarto da Artéria Cerebral Média/terapia , Trombectomia/instrumentação , Trombectomia/métodos , Dispositivos de Acesso Vascular , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/terapia , Feminino , Humanos , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Resultado do Tratamento
8.
Clin Chem Lab Med ; 59(2): 383-392, 2020 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-32866112

RESUMO

Objectives: Dual platelet inhibition is commonly used for prevention of cardiovascular events in patients undergoing neuroendovascular procedures. Non-responsiveness to platelet inhibitors may be associated with adverse outcomes. The aim of this study was to evaluate the reliability of the platelet function analyzer PFA-100® in comparison to light transmittance aggregometry (LTA) for monitoring clopidogrel and acetylsalicylic acid (ASA) non-responsiveness in a cohort of patients treated for intracranial aneurysm or cranial artery stenosis. Methods: Non-responsiveness to clopidogrel and ASA was assessed by LTA using adenosine diphosphate (ADP) and arachidonic acid and by PFA-100® with the ADP/prostaglandin E1 (PGE1) and collagen/epinephrine cartridges, respectively. Results: A total of 203 patients (145 females; median age, 57 years) were analyzed. Agreement between the two tests was poor for clopidogrel non-responsiveness (ƙ=0.19) and not better than chance for ASA non-responsiveness (ƙ=0.01). Clopidogrel non-responsiveness by LTA and PFA-100® was associated with higher von Willebrand factor antigen and activity levels. ADP-induced platelet disaggregation was lower in patients with clopidogrel non-responsiveness as assessed by PFA-100®. Clopidogrel non-responsiveness by LTA was associated with a higher prevalence of diabetes and a higher body mass index (BMI). Adverse outcomes (death, thromboembolism, or in-stent thrombosis) occurred in 13% (n=26) of all patients independently of ASA and clopidogrel non-responsiveness as assessed by both devices. Conclusions: Our results show that LTA and PFA-100® are not interchangeable in the assessment of ASA and clopidogrel non-responsiveness in patients undergoing neuroendovascular interventions.


Assuntos
Aspirina/análise , Testes de Coagulação Sanguínea/métodos , Clopidogrel/análise , Inibidores da Agregação Plaquetária/análise , Difosfato de Adenosina/metabolismo , Idoso , Alprostadil/metabolismo , Plaquetas/metabolismo , Colágeno/metabolismo , Epinefrina/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Agregação Plaquetária , Valores de Referência , Reprodutibilidade dos Testes , Stents , Avaliação da Tecnologia Biomédica , Trombose/metabolismo , Fatores de Tempo
9.
PLoS One ; 15(9): e0238952, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32941466

RESUMO

OBJECTIVE: To meet increasing demands to train neuroendovascular techniques, we developed a dedicated simulator applying individualized three-dimensional intracranial aneurysm models ('HANNES'; Hamburg Anatomic Neurointerventional Endovascular Simulator). We hypothesized that HANNES provides a realistic and reproducible training environment to practice coil embolization and to exemplify disparities between neurointerventionalists, thus objectively benchmarking operators at different levels of experience. METHODS: Six physicians with different degrees of neurointerventional procedural experience were recruited into a standardized training protocol comprising catheterization of two internal carotid artery (ICA) aneurysms and one basilar tip aneurysm, followed by introduction of one framing coil into each aneurysm and finally complete coil embolization of one determined ICA aneurysm. The level of difficulty increased with every aneurysm. Fluoroscopy was recorded and assessed for procedural characteristics and adverse events. RESULTS: Physicians were divided into inexperienced and experienced operators, depending on their experience with microcatheter handling. Mean overall catheterization times increased with difficulty of the aneurysm model. Inexperienced operators showed longer catheterization times (median; IQR: 47; 30-84s) than experienced operators (21; 13-58s, p = 0.011) and became significantly faster during the course of the attempts (rho = -0.493, p = 0.009) than the experienced physicians (rho = -0.318, p = 0.106). Number of dangerous maneuvers throughout all attempts was significantly higher for inexperienced operators (median; IQR: 1.0; 0.0-1.5) as compared to experienced operators (0.0; 0.0-1.0, p = 0.014). CONCLUSION: HANNES represents a modular neurointerventional training environment for practicing aneurysm coil embolization in vitro. Objective procedural metrics correlate with operator experience, suggesting that the system could be useful for assessing operator proficiency.


Assuntos
Educação Médica/métodos , Embolização Terapêutica/métodos , Treinamento por Simulação/métodos , Adulto , Prótese Vascular , Cateterismo/métodos , Angiografia Cerebral/métodos , Simulação por Computador , Estudos de Viabilidade , Feminino , Humanos , Aneurisma Intracraniano/terapia , Masculino , Pessoa de Meia-Idade , Modelos Biológicos
10.
Eur Respir J ; 56(2)2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32341107

RESUMO

The Global Lung Function Initiative (GLI) has recently published international reference values for diffusing capacity of the lung for carbon monoxide (D LCO). Lower limit of normal (LLN), i.e. the 5th percentile, usually defines impaired D LCO We examined if the GLI LLN for D LCO differs from the LLN in a Swedish population of healthy, never-smoking individuals and how any such differences affect identification of subjects with respiratory burden.Spirometry, D LCO, chest high-resolution computed tomography (HRCT) and questionnaires were obtained from the first 15 040 participants, aged 50-64 years, of the Swedish CArdioPulmonary bioImage Study (SCAPIS). Both GLI reference values and the lambda-mu-sigma (LMS) method were used to define the LLN in asymptomatic never-smokers without respiratory disease (n=4903, of which 2329 were women).Both the median and LLN for D LCO from SCAPIS were above the median and LLN from the GLI (p<0.05). The prevalence of D LCO GLI LLN but GLI LLN but GLI LLN and >SCAPIS LLN). No differences were found with regard to physician-diagnosed asthma.The GLI LLN for D LCO is lower than the estimated LLN in healthy, never-smoking, middle-aged Swedish adults. Individuals with D LCO above the GLI LLN but below the SCAPIS LLN had, to a larger extent, an increased respiratory burden. This suggests clinical implications for choosing an adequate LLN for studied populations.


Assuntos
Pulmão , Adulto , Feminino , Volume Expiratório Forçado , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Valores de Referência , Espirometria , Suécia/epidemiologia , Capacidade Vital
11.
Cardiovasc Intervent Radiol ; 43(2): 322-330, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31529176

RESUMO

PURPOSE: Magnetic particle imaging (MPI) is a novel tomographic radiation-free imaging technique that combines high spatial resolution and real-time capabilities, making it a promising tool to guide vascular interventions. Immediate availability of 3D image data is a major advantage over the presently used digital subtraction angiography (DSA), but new methods for real-time image analysis and visualization are also required to take full advantage of the MPI properties. This laboratory study illustrates respective techniques by means of three different patient-specific 3D vascular flow models. MATERIAL AND METHODS: The selected models corresponded to typical anatomical intervention sites. Routine patient cases and image data were selected, relevant vascular territories segmented, 3D models generated and then 3D-printed. Printed models were used to perform case-specific MPI imaging. The resulting MPI images, direct volume rendering (DVR)-based fast 3D visualization options, and their suitability to advance vascular interventions were evaluated and compared to conventional DSA. RESULTS: The experiments illustrated the feasibility and potential to enhance image interpretation during interventions by using MPI real-time volumetric imaging and problem-tailored DVR-based fast (approximately 30 frames/s) 3D visualization options. These options included automated viewpoint selection and cutaway views. The image enhancement potential is especially relevant for complex geometries (e.g., in the presence of superposed vessels). CONCLUSION: The unique features of the as-yet preclinical imaging modality MPI render it promising for guidance of vascular interventions. Advanced fast DVR could help to fulfill this promise by intuitive visualization of the 3D intervention scene in real time.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Nanopartículas de Magnetita , Radiologia Intervencionista/métodos , Tomografia/métodos , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/cirurgia , Estudos de Viabilidade , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/cirurgia , Humanos , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/cirurgia , Modelos Biológicos
12.
J Neurointerv Surg ; 12(2): 214-219, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31320551

RESUMO

BACKGROUND: Rapid development in endovascular aneurysm therapy continuously drives demand for suitable neurointerventional training opportunities. OBJECTIVE: To investigate the value of an integrated modular neurovascular training environment for aneurysm embolization using additively manufactured vascular models. METHODS: A large portfolio of 30 patient-specific aneurysm models derived from different treatment settings (eg, coiling, flow diversion, flow disruption) was fabricated using additive manufacturing. Models were integrated into a customizable neurointerventional simulator with interchangeable intracranial and cervical vessel segments and physiological circuit conditions ('HANNES'; Hamburg ANatomic Neurointerventional Endovascular Simulator). Multiple training courses were performed and participant feedback was obtained using a questionnaire. RESULTS: Training for aneurysm embolization could be reliably performed using HANNES. Case-specific clinical difficulties, such as difficult aneurysm access or coil dislocation, could be reproduced. During a training session, models could be easily exchanged owing to standardized connectors in order to switch to a different treatment situation or to change from 'treated' back to 'untreated' condition. Among 23 participants evaluating hands-on courses using a five-point scale from 1 (strongly agree) to 5 (strongly disagree), HANNES was mostly rated as 'highly suitable for practicing aneurysm coil embolization' (1.78±0.79). CONCLUSION: HANNES offers a wide variability and flexibility for case-specific hands-on training of intracranial aneurysm treatment, providing equal training conditions for each situation. The high degree of standardization offered may be valuable for analysis of device behavior or assessment of physician skills. Moreover, it has the ability to reduce the need for animal experiments.


Assuntos
Prótese Vascular/normas , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/normas , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Animais , Implante de Prótese Vascular/métodos , Embolização Terapêutica/métodos , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
13.
Malar J ; 18(1): 74, 2019 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-30871543

RESUMO

BACKGROUND: Previous studies have documented a spectrum of brain magnetic resonance imaging (MRI) abnormalities in patients with cerebral malaria, but little is known about the prevalence of such abnormalities in patients with non-cerebral malaria. The aim of this study was to assess the frequency of brain MRI findings in returning travellers with non-cerebral malaria. METHODS: A total of 17 inpatients with microscopically confirmed Plasmodium falciparum non-cerebral malaria underwent structural brain MRI at 3.0 Tesla, including susceptibility-weighted imaging (SWI). Presence of imaging findings was recorded and correlated with clinical findings and parasitaemia. RESULTS: Structural brain abnormalities included a hyperintense lesion of the splenium on T2-weighted imaging (n = 3) accompanied by visible diffusion restriction (n = 2). Isolated brain microhaemorrhage was detected in 3 patients. T2-hyperintense signal abnormalities of the white matter ranged from absent to diffuse (n = 10 had 0-5 lesions, n = 5 had 5-20 lesions and 2 patients had more than 50 lesions). Imaging findings were not associated with parasitaemia or HRP2 levels. CONCLUSION: Brain MRI reveals a considerable frequency of T2-hyperintense splenial lesions in returning travellers with non-cerebral malaria, which appears to be independent of parasitaemia.


Assuntos
Encefalopatias/diagnóstico por imagem , Encefalopatias/patologia , Doenças Transmissíveis Importadas/patologia , Imageamento por Ressonância Magnética , Malária Falciparum/patologia , Adulto , Encefalopatias/epidemiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Adulto Jovem
14.
J Neurointerv Surg ; 11(3): 283-289, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30049799

RESUMO

PURPOSE: Several different training environments for practicing neurointerventional procedures have been realized in silico, in vitro, and in vivo. We seek to replace animal-based training with suitable alternatives. In an effort to determine present training model distribution and preferences, we interviewed interventional neuroradiologists from 25 different countries about their experience in distinct training environments. METHODS: A voluntary online survey comprising 24 questions concerning the different training facilities was designed and electronically conducted with the members of the European Society for Minimally Invasive Neurological Therapy. RESULTS: Seventy-one physicians with an average experience of 11.8 (±8.7) years completed the survey. The majority of participants had experience with animal-based training (eg, stroke intervention: 36; 50.7%). Overall, animal-based training was rated as the most suitable environment to practice coil embolization (20 (±6)), flow diverter placement (13 (±7)), and stroke intervention (13.5 (±9)). In-vitro training before using a new device in patients was supported by most participants (35; 49.3%). Additionally, preference for certain training models was related to the years of experience. CONCLUSION: This survey discloses the preferred training modalities in European neurointerventional centers with the majority of physicians supporting the general concept of in-vitro training, concomitantly lacking a standardized curriculum for educating neurointerventional physicians. Most suitable training modalities appeared to be dependent on procedure and experience. As animal-based training is still common, alternate artificial environments meeting these demands must be further developed.


Assuntos
Competência Clínica/normas , Modelos Animais , Neuronavegação/educação , Neuronavegação/normas , Médicos/normas , Inquéritos e Questionários , Animais , Currículo/normas , Feminino , Humanos , Masculino , Neurologia/educação , Neurologia/normas
15.
J Neurointerv Surg ; 11(5): 479-484, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30514734

RESUMO

BACKGROUND AND PURPOSE: To evaluate factors influencing the confidence of management recommendation for unruptured intracranial aneurysms (UIAs) and to assess the ability of neurointerventionalists to predict procedure-related neurological complications compared with a 3-point risk score. MATERIALS AND METHODS: Twenty-eight neurointerventionalists were asked to evaluate digital subtraction angiographies examinations of patients with UIAs by determining the best management approach, their level of confidence in their management recommendation, and estimating the risk of procedure-related neurological complications. Knowledge and experience in interventional neuroradiology (INR) of each participant were assessed. RESULTS: Reliability was moderate regarding any treatment recommendation (ICC=0.49) and low regarding the estimation of risk of complications (ICC=0.38). The recommendation of clipping was less likely with more experience in INR (OR=0.6) and more likely with increasing knowledge (OR=1.7). Odds of recommending WEB device were lower with more experience in INR (OR=0.6), higher in patients with multiple aneurysms (OR=3.6) and increasing neck width (OR=2.7). The recommendation of stent-assisted coiling was more likely with increasing neck width (OR=2.4) and when cerebral ischemic comorbidities were present (OR=2.9). The participants were significantly worse than the risk score (mean area under the curve of 0.53) and not better than random guess in predicting complications. Neither knowledge nor experience in INR was significantly associated with the participants' ability to predict neurological complications. CONCLUSIONS: Our study shows a moderate interrater reliability of treatment recommendations of UIAs. Confidence in treatment recommendation varied significantly according to recommended treatments. Overall performance in predicting neurological complications was worse than the risk score and not better than random guess.


Assuntos
Tomada de Decisão Clínica , Aneurisma Intracraniano/terapia , Doenças do Sistema Nervoso/etiologia , Procedimentos Neurocirúrgicos/métodos , Complicações Pós-Operatórias/terapia , Medição de Risco , Adulto , Idoso , Angiografia Digital , Feminino , Humanos , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Doenças do Sistema Nervoso/diagnóstico por imagem , Procedimentos Neurocirúrgicos/efeitos adversos , Radiologia Intervencionista , Stents , Resultado do Tratamento
16.
J Neurointerv Surg ; 11(4): 425-430, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30327387

RESUMO

BACKGROUND AND PURPOSE: Evidence on how to select microcatheters to facilitate aneurysm catheterization during coil embolization is sparse. We developed a new method to define microcatheter tip location inside a patient-specific aneurysm model as a 3-dimensional probability map. We hypothesized that precision and accuracy of microcatheter tip positioning depend on catheter tip shape and aneurysmal geometry. MATERIALS AND METHODS: Under fluoroscopic guidance two to three operators introduced differently shaped microcatheters (straight, 45°, 90°) into eight aneurysm models targeting the anatomic center of the aneurysm. Each microcatheter position was recorded with flat-panel CT, and 3-dimensional probability maps of the microcatheter tip positions were generated. Maps were assessed with histogram analyses and compared between tip shapes, aneurysm locations and operators. RESULTS: Among a total of 530 microcatheter insertions, the precision (mean distance between catheter positions) and accuracy (mean distance to target position) were significantly higher for the 45° tip (1.10±0.64 mm, 3.81±1.41 mm, respectively) than for the 90° tip (1.27±0.57 mm, p=0.010; 4.21±1.60 mm p=0.014, respectively). Accuracy was significantly higher in posterior communicating artery aneurysms (3.38±1.20 mm) than in aneurysms of the internal carotid artery (4.56±1.54 mm, p<0.001). CONCLUSION: Our method can be used tostatistically describe statistically microcatheter behavior in patient-specific anatomy, which may improve the available evidence guiding microcatheter shape selection. Experience increases the ability to reach the intended position with a microcatheter (accuracy) that is also dependent on the aneurysm location, whereas catheter tip choice determines the variability of catheter tip placements versus each other (precision). Clinical validation is required.


Assuntos
Cateterismo/instrumentação , Catéteres , Angiografia Cerebral/instrumentação , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Artéria Carótida Interna/diagnóstico por imagem , Cateterismo/métodos , Catéteres/tendências , Angiografia Cerebral/tendências , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Feminino , Fluoroscopia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
17.
Sci Rep ; 8(1): 15999, 2018 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-30375473

RESUMO

Hemodynamic properties and deformation of vessel structures are assumed to be correlated to the initiation, development, and rupture of cerebral aneurysms. Therefore, precise quantification of wall motion is essential. However, using standard-of-care imaging data, approaches for patient-specific estimation of pulsatile deformation are prone to uncertainties due to, e.g., contrast agent inflow-related intensity changes and small deformation compared to the image resolution. A ground truth dataset that allows evaluating and finetuning algorithms for deformation estimation is lacking. We designed a flow phantom with deformable structures that resemble cerebral vessels and exhibit physiologically plausible deformation. The deformation was simultaneously recorded using a flat panel CT and a video camera, yielding video data with higher resolution and SNR, which was used to compute 'ground truth' structure deformation measures. The dataset was further applied to evaluate registration-based deformation estimation. The results illustrate that registration approaches can be used to estimate deformation with adequate precision. Yet, the accuracy depended on the registration parameters, illustrating the need to evaluate and finetune deformation estimation approaches by ground truth data. To fill the existing gap, the acquired benchmark dataset is provided freely available as the CAPUT (Cerebral Aneurysm PUlsation Testing) dataset, accessible at https://www.github.com/IPMI-ICNS-UKE/CAPUT .


Assuntos
Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/patologia , Neuroimagem , Algoritmos , Biomarcadores , Análise de Dados , Bases de Dados Factuais , Humanos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Neuroimagem/métodos , Neuroimagem/normas , Imagens de Fantasmas , Reprodutibilidade dos Testes
18.
Sci Rep ; 8(1): 11004, 2018 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-30030483

RESUMO

Cardiac-cycle related pulsatile aneurysm motion and deformation is assumed to provide valuable information for assessing cerebral aneurysm rupture risk. Accordingly, numerous studies addressed quantification of cerebral aneurysm wall motion and deformation. Most of them utilized in vivo imaging data, but image-based aneurysm deformation quantification is subject to pronounced uncertainties: unknown ground-truth deformation; image resolution in the order of the expected deformation; direct interplay between contrast agent inflow and image intensity. To analyze the impact of the uncertainties on deformation quantification, a multi-imaging modality ground-truth phantom study is performed. A physical flow phantom was designed that allowed simulating pulsatile flow through a variety of modeled cerebral vascular structures. The phantom was imaged using different modalities [MRI, CT, 3D-RA] and mimicking physiologically realistic flow conditions. Resulting image data was analyzed by an established registration-based approach for automated wall motion quantification. The data reveals severe dependency between contrast media inflow-related image intensity changes and the extent of estimated wall deformation. The study illustrates that imaging-related uncertainties affect the accuracy of cerebral aneurysm deformation quantification, suggesting that in vivo imaging studies have to be accompanied by ground-truth phantom experiments to foster data interpretation and to prove plausibility of the applied image analysis algorithms.


Assuntos
Aneurisma Intracraniano/patologia , Movimento (Física) , Imagens de Fantasmas , Fluxo Pulsátil/fisiologia , Incerteza , Algoritmos , Aneurisma Roto/diagnóstico por imagem , Vasos Sanguíneos/diagnóstico por imagem , Vasos Sanguíneos/patologia , Vasos Sanguíneos/fisiopatologia , Circulação Cerebrovascular/fisiologia , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Modelos Biológicos , Imagem Multimodal
19.
J Neurointerv Surg ; 10(10): 988-994, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29440326

RESUMO

OBJECTIVE: To evaluate multiparametric MRI including non-contrast and contrast-enhanced morphological and angiographic techniques for intracranial aneurysms treated with the single-layer Woven EndoBridge (WEB) embolization system applying simultaneous digital subtraction angiography (DSA) as the reference of standard. MATERIALS AND METHODS: We retrospectively identified all patients with incidental and acute ruptured intracranial aneurysms treated with a WEB device (WEB SL and WEB SLS) between March 2014 and June 2016 in our neurovascular center with early (within 7 days) postinterventional multiparametric MRI as well as mid-term (5-8 months) follow-up MRI and DSA available. Occlusion rates were recorded both in DSA and MR angiography (MRA). In MRI, signal intensities within the WEB as well as in the occluded dome distal to the WEB, if present, were measured by region-of-interest (ROI) analysis. RESULTS: Twenty-five patients fulfilled the inclusion criteria. Rates of complete/adequate occlusion at mid-term follow-up were 84% with both MRA and DSA. A strong signal loss within the WEB was observed in all MR sequences at initial and follow-up examinations. ROI analysis did not reveal significant differences in non-contrast (P=0.946) and contrast-enhanced imaging (P=0.377). A T1-hyperintense thrombus in the non-WEB-carrying dome was a frequent observation. CONCLUSIONS: Signal intensity measurements in multiparametric MRI suggest that neither contrast-enhanced MRA nor morphological sequences are capable of revealing reliable information on the WEB lumen, presumably due to radio frequency shielding. MRI is therefore not suitable for confirming complete thrombus formation within the WEB.


Assuntos
Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/terapia , Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Angiografia Digital/métodos , Embolização Terapêutica/métodos , Feminino , Seguimentos , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
20.
PLoS One ; 13(2): e0191975, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29408857

RESUMO

BACKGROUND AND PURPOSE: Flow disruption achieved by braided intrasaccular implants is a novel treatment strategy for cerebrovascular aneurysms. We hypothesized that the degree of intra-aneurysmal flow disruption can be quantified in vitro and is influenced by device position across the aneurysm neck. We tested this hypothesis using the Medina® Embolization Device (MED). METHODS: Ten different patient-specific elastic vascular models were manufactured. Models were connected to a pulsatile flow circuit, filled with a blood-mimicking fluid and treated by two operators using a single MED. Intra-aneurysmal flow velocity was measured using conventional and high-frequency digital subtraction angiography (HF-DSA) before and after each deployment. Aneurysm neck coverage by the implanted devices was assessed with flat detector computed tomography on a three-point Likert scale. RESULTS: A total of 80 individual MED deployments were performed by the two operators. The mean intra-aneurysmal flow velocity reduction after MED implantation was 33.6% (27.5-39.7%). No significant differences in neck coverage (p = 0.99) or flow disruption (p = 0.84) were observed between operators. The degree of flow disruption significantly correlated with neck coverage (ρ = 0.42, 95% CI: 0.21-0.59, p = 0.002) as well as with neck area (ρ = -0,35, 95% CI: -0.54 --0.13, p = 0.024). On multiple regression analysis, both neck coverage and total neck area were independent predictors of flow disruption. CONCLUSIONS: The degree of intra-aneurysmal flow disruption after MED implantation can be quantified in vitro and varies considerably between different aneurysms and different device configurations. Optimal device coverage across the aneurysm neck improves flow disruption and may thus contribute to aneurysm occlusion.


Assuntos
Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/cirurgia , Próteses e Implantes , Angiografia Digital , Circulação Cerebrovascular , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/fisiopatologia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...