Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Spine (Phila Pa 1976) ; 49(5): 349-355, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36856517

RESUMO

STUDY DESIGN: This was a retrospective cohort study. OBJECTIVE: There are preoperative characteristics that predict rod lengthening of magnetically controlled growing rods (MCGR). The lengthening of MCGR will lead to increased kyphosis. SUMMARY OF BACKGROUND DATA: The amount of length gained by MCGR is variable, and predictors are lacking. Similarly, sagittal plane changes over the MCGR lengthening period have not been investigated. MATERIALS AND METHODS: Patients with MCGR and a minimum 2-year follow-up were identified and those with previous spine surgery were excluded. Preimplantation, postimplantation, and last follow-up postlengthening radiographs were examined. Multiple linear regression analyses were used for rod length gain predictors. RESULTS: Fifty-six patients with early-onset scoliosis met inclusion criteria: nine idiopathic, five congenital, 14 neuromuscular, 20 syndromic, and eight skeletal dysplasia patients. No difference was seen between subtypes of early-onset scoliosis for rod length gain ( P =0.62). Shorter preoperative T1-T12 height and higher curve correction rate after implantation were significant predictors for rod length gain ( P <0.001). Preoperative major curve magnitude and kyphosis were not significant predictors. Flattening of the spine around the actuator and compensative increase in T1-T5 kyphosis were seen secondarily after MCGR implantation. Maximum sagittal kyphosis, T1-T5 kyphosis, and T5-T12 kyphosis did not change during lengthening. Lumbar lordosis significantly decreased postimplantation (first erect) but then increased during lengthening. Pelvic incidence and sacral slope both increased during lengthening, but this may be age related. CONCLUSION: Patients who gained the most rod length with MCGR were those with an initially shorter T1-T12 height and better initial curve correction at implantation, likely representing that implants work best in small patients with flexible curves. Diagnosis, preoperative curve magnitude, and thoracic kyphosis were not related to rod length gain. Thoracic kyphosis did not deteriorate over the lengthening phase. LEVEL OF EVIDENCE: Level III-retrospective cohort study.


Assuntos
Cifose , Escoliose , Humanos , Escoliose/cirurgia , Seguimentos , Estudos Retrospectivos , Cifose/cirurgia , Sacro , Resultado do Tratamento
2.
J Pediatr Orthop ; 43(6): e465-e470, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37026790

RESUMO

BACKGROUND: Osteogenesis imperfecta (OI) is a genetic disorder characterized by brittle bones and long bone deformity. Realignment and intramedullary rodding with telescopic rods are indicated for progressive deformity and can help prevent fractures. Rod bending is a reported complication of telescopic rods and a common indication for revision; however, the fate of bent lower extremity telescopic rods in the setting of OI has not been reported. METHODS: Patients with OI at a single institution who underwent lower extremity telescopic rod placement with at least 1-year follow-up were identified. Bent rods were identified, and for these bone segments, we collected the location and angle of bend, subsequent telescoping, refracture, increasing angulation of bend, and date of revision. RESULTS: One hundred sixty-eight telescopic rods in 43 patients were identified. Forty-six rods (27.4%) bent during follow-up, with an average angulation of 7.3 (range: 1 to 24) degrees. In patients with severe OI, 15.7% of rods bent compared with 35.7% in nonsevere OI ( P =0.003). The proportion of bent rods was different between independent and nonindependent ambulators (34.1% and 20.5%; P =0.035). Twenty-seven bent rods (58.7%) were revised, with 12 rods (26.0%) revised early (within 90 d). The angulation of rods that were revised early was significantly higher than rods not (14.6 and 4.3 degrees, P <0.001). Of the 34 bent rods not revised early, the average time to revision or final follow-up was 29.1 months. Twenty-five rods (73.5%) continued to telescope, 14 (41.2%) increased in angulation (average 3.2 degrees), and 10 bones (29.4%) refractured. None of the refractures required immediate rod revision. Two bones had multiple refractures. CONCLUSIONS: Bending is a common complication of telescopic rods in the lower extremities of patients with OI. It is more common in independent ambulators and patients with nonsevere OI, possibly because of the increased demand placed on the rods. Rods with a small bend and maintained fixation can telescope and need not be an indication for immediate revision. LEVEL OF EVIDENCE: Level III-Retrospective review.


Assuntos
Fraturas Ósseas , Osteogênese Imperfeita , Criança , Humanos , Osteogênese Imperfeita/cirurgia , Osteogênese Imperfeita/complicações , Fixadores Internos , Fraturas Ósseas/cirurgia , Estudos Retrospectivos
4.
Hand (N Y) ; 16(6): 776-780, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-31795756

RESUMO

Background: The aim of this preliminary study was to evaluate the effectiveness of a J-tip needle-free injection system (JNFS) to reduce pain associated with corticosteroid injection of the tendon sheath for treatment of trigger finger. Methods: Thirty-four consecutive trigger fingers occurring in 28 unique patients who met inclusion/exclusion criteria were consented and enrolled into this double-blind randomized controlled study. Patients were randomly assigned to the control (JNFS loaded with sterile normal saline) or treatment group (JNFS loaded with buffered 1% lidocaine). Both the fellowship-trained hand surgeon and patient were blinded to the allocation group. Prior to each trigger finger injection, each patient rated pain associated with stubbing toe and papercut on the visual analog scale (VAS), in addition to a postprocedure VAS pain score. Results: A total of 28 patients and 34 digits were enrolled in this study. There was no difference in patient demographics or preintervention pain perception between the control and treatment groups. The use of JNFS demonstrated lower mean pain VAS score when comparing the control group (n = 17) with the treatment group (n = 17), with VAS pain scores of 49 (SD = 31) and 39 (SD = 36), respectively. However, this difference was not statistically significant (P = .389). Conclusions: The use of JNFS loaded with 1% buffered lidocaine may reduce pain associated with trigger finger injections, although our results did not find a statistically significant difference. We hypothesize that the pain caused by the acidity of lidocaine is the primary driver of pain and discomfort during injection, and the pain from the needle stick is secondary. As a result, any pain reduction from JNFS is masked by the most painful part of injection-the delivery of injectate. Based on the findings and experience obtained from this study, we hypothesize that a follow-up study using buffered lidocaine may be able to better reveal the benefits of JNFS.


Assuntos
Dedo em Gatilho , Anestésicos Locais/uso terapêutico , Seguimentos , Humanos , Injeções , Lidocaína , Dedo em Gatilho/tratamento farmacológico
5.
J Am Acad Orthop Surg Glob Res Rev ; 3(9): e037, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31773079

RESUMO

Hip pathology during pregnancy may include transient osteoporosis of the hip or osteonecrosis associated with pregnancy. Rarely, hip pathology during pregnancy may result in a fragility fracture or advanced collapse of the femoral head, necessitating surgical treatment. We present a case of a 32-year-old woman who postpartum was found to have a displaced right femoral neck fracture and an area of focal edema in the left femoral head with mild flattening of the articular surface. She was successfully treated with a total hip arthroplasty on the right, and a follow-up MRI of the left hip showed near-complete resolution of the edema in the femoral head. This case underlines the importance of maintaining a clinical suspicion for pathology of the hip during pregnancy and the subsequent consequences of a missed diagnosis.

6.
Knee Surg Sports Traumatol Arthrosc ; 25(10): 3134-3139, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27344549

RESUMO

PURPOSE: Injury to the anterolateral ligament (ALL) of the knee has recently received attention as a potential risk factor for failure of anterior cruciate ligament reconstruction. However, evaluation of the anterolateral ligament is currently difficult, and radiologic data are sparse with regard to the normal appearance of this ligament. The purpose of the present study was to determine whether the ALL could be identified and visualized using ultrasonography. METHODS: Ten non-paired, fresh-frozen cadaveric knees underwent ultrasound by an experienced musculoskeletal radiologist using a Siemens S2000 Acuson Ultrasound machine with a 14-MHz linear transducer. After first identifying anatomical landmarks by palpation, a thin band of tissue originating in the vicinity of the fibular collateral ligament (FCL) origin was identified and followed up distally. The tibia was held at 30° of flexion and internally rotated to verify tightening of the structure. Under ultrasound guidance, 25-gauge hypodermic needles were placed at what were sonographically determined to be the origin and insertion points of the ligament. One-tenth of a CC of aniline blue dye was injected. The specimens were then dissected to confirm the presence and location of the ALL. If an ALL was found, distances between the epicentre of the injected dye and the actual origin and insertion points were calculated. Additionally, ligament length based on dissection images and ultrasound images was calculated. RESULTS: Eight of ten specimens had an anterolateral structure that originated from the lateral femoral epicondyle just posterior and superior to the origin of the FCL and inserted on the lateral plateau approximately halfway between Gerdy's tubercle and the fibular head. The average length based on ultrasound was 3.8 cm (±.7; range 3.1-4.7) and 4.1 cm (±1.1; range 2.6-6.1) based on dissection. Length based on dissection and ultrasound had minimal agreement (ICC = .308; 95 % confidence interval .257-.382, p = .265). The average width of the structure on dissection was .8 cm (±.24; range .5-1.2). The mean distance from ultrasound-determined origin and insertion points to anatomical origin and insertion based on dissection was 10.9 mm (±2.9, range 7.0-15.8) and 12.5 mm (±5.7 range 3.2-19.3), respectively. Inter-observer reliability was excellent for all measurements based on dissection and ultrasound. CONCLUSION: Ultrasound was unable to reliably identify the anterolateral structure from its femoral to tibial attachment sites. Distinguishing it from the posterior IT band and anterolateral capsule was challenging, and it is possible that the structure is a thickened band of fascia rather than a true ligament. As a clinical diagnostic tool, ultrasound likely offers little utility in the evaluation of the ALL for injury. LEVEL OF EVIDENCE: IV.


Assuntos
Ligamento Cruzado Anterior/diagnóstico por imagem , Traumatismos do Joelho/diagnóstico por imagem , Ultrassonografia/métodos , Reconstrução do Ligamento Cruzado Anterior , Cadáver , Feminino , Humanos , Articulação do Joelho/patologia , Masculino , Amplitude de Movimento Articular , Reprodutibilidade dos Testes
7.
Arthroscopy ; 33(2): 355-361, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27625004

RESUMO

PURPOSE: To assess screw divergence when inserting an interference screw for a bone-patellar tendon-bone graft using an outside-in technique with a retrograde drill to create the femoral tunnel. METHODS: Ten cadaver specimens underwent anterior cruciate ligament reconstruction with a bone-patellar tendon-bone autograft, with 23-mm-deep tunnels created by a retrograde drill outside-in technique. Drilling angles were based on a previous study that established the optimal angles to recreate the anterior cruciate ligament footprint. To ensure that screw insertion angles matched the angle of socket drilling, a marking pen was used to transpose 2 lines on the skin of the anterior knee corresponding to the drill in both the coronal and axial planes with the knee held at 90° of flexion. The femoral-sided bone plug was affixed with a 7 × 23 mm interference screw through an anteromedial portal. Computed tomography scans were used to calculate coronal and sagittal screw-tunnel divergence. RESULTS: The median screw divergence in the coronal plane was 2.79°, with a range of 1.1° to 17.2°. Of 10 specimens, 8 had no divergence (0° to 5°), 0 screws were between 5° and 10°, 1 screw was between 10° and 15°, and 1 screw was between 15° and 20°. The 95% confidence interval was 3.73° to 11.69°. No screws had ≥20° of divergence. In the sagittal plane, the median screw divergence was 5.68°, with a range of 1.2° to 18.7°. Five specimens had no divergence (0° to 5°), 3 screws were between 5° and 10°, 0 screws were between 10° and 15°, and 2 screws were between 15° and 20° of divergence. The 95% confidence interval was 3.73° to 11.69°. No screws had ≥20° of divergence. CONCLUSIONS: The results of this study showed that 80% of screws diverted less than 5° in the coronal plane. In the sagittal plane, only 50% of screws were found to have divergence of 5° or less. No screw in either plane had divergence of greater than or equal to 20°. CLINICAL RELEVANCE: When using a retrograde drill, a skin marking technique is a useful aid in placing interference screws with acceptable angles of divergence when using an inside-out technique.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Parafusos Ósseos , Enxertos Osso-Tendão Patelar-Osso , Fenômenos Biomecânicos , Cadáver , Fêmur/cirurgia , Humanos , Patela/cirurgia , Amplitude de Movimento Articular , Tomografia Computadorizada por Raios X
8.
Arthrosc Tech ; 5(5): e953-e958, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27909660

RESUMO

Knee pain in young, active patients with meniscus-deficient knees and articular cartilage damage can present a challenge to treatment. Meniscal allograft transplantation (MAT) has shown good clinical results as treatment for meniscus deficiency; however, worse outcomes have been observed in patients with significant chondral damage. The development of chondral restorative techniques such as osteochondral allograft transplantation (OCA) has expanded the population of patients who may benefit from MAT. We present a case of proximal tibial osteochondral and lateral meniscal allograft transplant. This review includes a sample of patient examinations and imaging, followed by a detailed technical description of the case. The technique article concludes with a discussion on the niche combined MAT-OCA procedures occupy in the patient treatment realm.

9.
Arthrosc Tech ; 5(4): e821-e825, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27709043

RESUMO

Patients with gluteus minimus and medius tears that fail nonoperative management may be indicated for surgical repair; however, structural failure after gluteal tendon repair remains unacceptably high. This is likely related to the limited healing potential of tendinous tissue, which is poorly vascular and heals by formation of fibrocartilaginous scar tissue rather than histologically normal tendon. An emerging option to augment tendon healing is the use of a bioinductive implant that is designed to amplify the host healing response and induce the formation of healthy tendon tissue. Though it is rapidly being adopted for partial- and full-thickness rotator cuff tears, this implant has not yet been used in the hip. A detailed technical description and a discussion of the advantages and disadvantages of the technique are provided.

10.
JBJS Rev ; 4(6)2016 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-27486722

RESUMO

The poor intrinsic healing potential of tendon and ligamentous tissue has driven the search for biological agents that can improve healing, most notably platelet-rich plasma (PRP) and autologous stem cells. Current evidence best supports the use of PRP as treatment for chronic, degenerative tendinopathies such as lateral epicondylitis of the elbow or patellar tendinopathy. It does not support the use of PRP to promote tendon or ligament-to-bone healing in rotator cuff repair or anterior cruciate ligament (ACL) reconstruction. Clinical evidence regarding the use of autologous stem cells as treatment for tendon and ligament abnormalities is currently limited. However, the initial results appear to be promising, particularly following rotator cuff repair. A major limitation in the evaluation of current data is the lack of standardization in the preparation and composition of PRP, which are often not reported. Future investigators should make an effort to report the method of preparation and final composition of PRP used. Autologous stem cells were most often harvested from bone marrow aspirate but were occasionally derived from dermal tenocyte cells. Recent studies have explored new sources for stem cells, including adipose tissue, peripheral blood, and human amniotic tissue. We expect that clinical data evaluating these treatments will soon emerge.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Plasma Rico em Plaquetas , Tendinopatia/terapia , Humanos , Ligamentos , Lesões do Manguito Rotador , Traumatismos dos Tendões , Tendões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...