Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mater Sci Eng C Mater Biol Appl ; 37: 332-41, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24582257

RESUMO

Nanostructured surface geometries have been the focus of a multitude of recent biomaterial research, and exciting findings have been published. However, only a few publications have directly compared nanostructures of various surface chemistries. The work herein directly compares the response of human osteoblast cells to surfaces of identical nanotube geometries with two well-known orthopedic biomaterials: titanium oxide (TiO2) and tantalum (Ta). The results reveal that the Ta surface chemistry on the nanotube architecture enhances alkaline phosphatase activity, and promotes a ~30% faster rate of matrix mineralization and bone-nodule formation when compared to results on bare TiO2 nanotubes. This study implies that unique combinations of surface chemistry and nanostructure may influence cell behavior due to distinctive physico-chemical properties. These findings are of paramount importance to the orthopedics field for understanding cell behavior in response to subtle alterations in nanostructure and surface chemistry, and will enable further insight into the complex manipulation of biomaterial surfaces. With increased focus in the field of orthopedic materials research on nanostructured surfaces, this study emphasizes the need for careful and systematic review of variations in surface chemistry in concurrence with nanotopographical changes.


Assuntos
Nanotubos/química , Osteoblastos/citologia , Tantálio/química , Titânio/química , Citoesqueleto de Actina/efeitos dos fármacos , Fosfatase Alcalina/metabolismo , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Diferenciação Celular/efeitos dos fármacos , Células Cultivadas , Humanos , Osteoblastos/metabolismo , Osteogênese/efeitos dos fármacos , Propriedades de Superfície
2.
Mater Sci Eng C Mater Biol Appl ; 33(3): 1460-6, 2013 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-23827596

RESUMO

Titanium oxide (TiO2) nanotube arrays were prepared by anodization of Ti/Au/Ti trilayer thin film DC sputtered onto forged and cast Co-28Cr-6Mo alloy substrate at 400 °C. Two different types of deposited film structures (Ti/Au/Ti trilayer and Ti monolayer), and two deposition temperatures (room temperature and 400 °C) were compared in this work. The concentrations of ammonium fluoride (NH4F) and H2O in glycerol electrolyte were varied to study their effect on the formation of TiO2 nanotube arrays on a forged and cast Co-28Cr-6Mo alloy. The results show that Ti/Au/Ti trilayer thin film and elevated temperature sputtered films are favorable for the formation of well-ordered nanotube arrays. The optimized electrolyte concentration for the growth of TiO2 nanotube arrays on forged and cast Co-28Cr-6Mo alloy was obtained. This work contains meaningful results for the application of a TiO2 nanotube coating to a CoCr alloy implant for potential next-generation orthopedic implant surface coatings with improved osseointegrative capabilities.


Assuntos
Teste de Materiais/métodos , Nanotubos/química , Titânio/farmacologia , Vitálio/farmacologia , Eletricidade , Eletrodos , Eletrólitos/química , Humanos , Nanotubos/ultraestrutura , Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Osteoblastos/ultraestrutura , Temperatura , Fatores de Tempo
3.
Int J Biomater ; 2013: 513680, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23710182

RESUMO

The complex mechanisms of the bone cell-surface interactions are yet to be completely understood, and researchers continue to strive to uncover the fully optimized implant material for perfect osseointegration. A particularly fascinating area of research involves the study of nanostructured surfaces, which are believed to enhance osteogenic behavior, possibly due to the mimicry of components of the extracellular matrix of bone. There is a growing body of data that emphasizes the promise of the titanium oxide (TiO2) nanotube architecture as an advanced orthopedic implant material. The review herein highlights findings regarding TiO2 nanotube surfaces for bone regeneration and the osteogenic effects of minute changes to the surface such as tube size and surface chemistry.

4.
Mater Sci Eng C Mater Biol Appl ; 33(5): 2752-6, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-23623092

RESUMO

Various approaches have been studied to engineer the implant surface to enhance bone in-growth properties, particularly using micro- and nano-topography. In this study, the behavior of osteoblast (bone) cells was analyzed in response to a titanium oxide (TiO2) nanotube-coated commercial zirconia femoral knee implant consisting of a combined surface structure of a micro-roughened surface with the nanotube coating. The osteoblast cells demonstrated high degrees of adhesion and integration into the surface of the nanotube-coated implant material, indicating preferential cell behavior on this surface when compared to the bare implant. The results of this brief study provide sufficient evidence to encourage future studies. The development of such hierarchical micro- and nano-topographical features, as demonstrated in this work, can provide insightful designs for advanced bone-inducing material coatings on ceramic orthopedic implant surfaces.


Assuntos
Osso e Ossos/citologia , Adesão Celular , Fêmur , Prótese de Quadril , Prótese do Joelho , Nanotubos , Titânio/química , Zircônio , Células 3T3 , Animais , Teste de Materiais , Camundongos , Microscopia Eletrônica de Varredura , Propriedades de Superfície
5.
Mater Sci Eng C Mater Biol Appl ; 33(1): 259-64, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25428070

RESUMO

Highly ordered TiO2 nanotube arrays with large diameter of 680-750 nm have been prepared by high voltage anodization in an electrolyte containing ethylene glycol at room temperature. To effectively suppress dielectric breakdown due to high voltage, pre-anodized TiO2 film was formed prior to the main anodizing process. Vertically aligned, large sized TiO2 nanotubes with double-wall structure have been demonstrated by SEM in detail under various anodizing voltages up to 225 V. The interface between the inner and outer walls in the double-wall configuration is porous. Surface topography of the large diameter TiO2 nanotube array is substantially improved and effective control of the growth of large diameter TiO2 nanotube array is achieved. Interestingly, the hemispherical barrier layer located at the bottom of TiO2 nanotubes formed in this work has crinkles analogous to the morphology of the brain cortex. These structures are potentially useful for orthopedic implants, storage of biological agents for controlled release, and solar cell applications.


Assuntos
Nanotubos/química , Titânio/química , Eletricidade , Eletrólitos/química , Etilenoglicol/química , Microscopia Eletrônica de Varredura , Nanotubos/ultraestrutura , Porosidade , Temperatura
6.
Trends Biotechnol ; 30(6): 315-22, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22424819

RESUMO

Nanostructured materials are believed to play a fundamental role in orthopedic research because bone itself has a structural hierarchy at the first level in the nanometer regime. Here, we report on titanium oxide (TiO(2)) surface nanostructures utilized for orthopedic implant considerations. Specifically, the effects of TiO(2) nanotube surfaces for bone regeneration will be discussed. This unique 3D tube shaped nanostructure created by electrochemical anodization has profound effects on osteogenic cells and is stimulating new avenues for orthopedic material surface designs. There is a growing body of data elucidating the benefits of using TiO(2) nanotubes for enhanced orthopedic implant surfaces. The current trends discussed within foreshadow the great potential of TiO(2) nanotubes for clinical use.


Assuntos
Regeneração Óssea , Nanotubos , Titânio , Adesão Celular , Humanos , Teste de Materiais , Modelos Biológicos , Próteses e Implantes
7.
Acta Biomater ; 7(6): 2697-703, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21382531

RESUMO

Surface engineering approaches that alter the topological chemistry of a substrate could be used as an effective tool for directing cell interactions and their subsequent function. It is well known that the physical environment of nanotopography has positive effects on cell behavior, yet direct comparisons of nanotopographic surface chemistry have not been fully explored. Here we compare TiO(2) nanotubes with carbon-coated TiO(2) nanotubes, probing osteogenic cell behavior, including osteoblast (bone cells) and mesenchymal stem cell (MSC) (osteo-progenitor cells) interactions with the different surface chemistries (TiO(2) vs. carbon). The roles played by the material surface chemistry of the nanotubes did not have an effect on the adhesion, growth or morphology, but had a major influence on the alkaline phosphatase (ALP) activity of osteoblast cells, with the original TiO(2) chemistry having higher ALP levels. In addition, the different chemistries caused different levels of osteogenic differentiation in MSCs; however, it was the carbon-coated TiO(2) nanotubes that had the greater advantage, with higher levels of osteo-differentiation. It was observed in this study that: (a) chemistry plays a role in cell functionality, such as ALP activity and osteogenic protein gene expression (PCR); (b) different cell types may have different chemical preferences for optimal function. The ability to optimize cell behavior using surface chemistry factors has a profound effect on both orthopedic and tissue engineering in general. This study aims to highlight the importance of the chemistry of the carrier material in osteogenic tissue engineering schemes.


Assuntos
Nanotubos de Carbono , Osteoblastos/citologia , Células-Tronco/citologia , Titânio , Células 3T3 , Animais , Camundongos , Reação em Cadeia da Polimerase
8.
Acta Biomater ; 7(2): 683-90, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20863916

RESUMO

Surface engineering approaches that alter the physical topography of a substrate could be used as an effective tool and as an alternative to biochemical means of directing stem cell interactions and their subsequent differentiation. In this paper we compare hydrophobic micro- vs. nanopillar type fabrication techniques for probing mesenchymal stem cell (MSC) interaction with the surface physical environment. The roles played by the topography of the nanopillar in particular influenced MSC growth and allowed for regulatory control of the stem cell fate. The nanopillar induced large 3-D cell aggregates to form on the surface which had up-regulated osteogenic specific matrix components. The ability to control MSC differentiation, using only the topographical factors, has a profound effect on both MSC biology and tissue engineering. This study aims to highlight the importance of the physical material carrier in stem cell based tissue engineering schemes.


Assuntos
Diferenciação Celular , Interações Hidrofóbicas e Hidrofílicas , Células-Tronco Mesenquimais/citologia , Nanoestruturas/química , Osteogênese , Actinas/metabolismo , Animais , Agregação Celular , Linhagem da Célula , Sobrevivência Celular , Matriz Extracelular/metabolismo , Células-Tronco Mesenquimais/ultraestrutura , Nanoestruturas/ultraestrutura , Ratos , Coloração e Rotulagem
9.
J Phys Chem B ; 114(45): 14537-43, 2010 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-20527771

RESUMO

We have designed and constructed dye sensitized solar cells based on new, 3-D configurations of TiO(2) nanotubes. The overall efficiency of our best cells is 5.0% under standard air mass 1.5 global (AM 1.5 G) solar conditions, and the incident photon-to-current efficiency exceeds 60% over a broad part of the visible spectrum. Unlike prior nanotube-based cells where tubes are grown vertically in a 2-D array, the anodes of the present cells consist of tubes that extend radially in a 3-D array from a grid of fine titanium wires. The nanotubes are tens of micrometers in length, and the radial nature of the anode allows the photon absorption path length to exceed the electron transport distance (nanotube length). The cells are front-illuminated and do not require a transparent conductive oxide substrate at either the anode or cathode. The use of 3-D configured nanotubes and low-resistance titanium metal substrates are expected to enhance the performance and simplify the construction of large area dye-sensitized solar cells.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...