Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Omega ; 9(26): 28412-28421, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38973844

RESUMO

Metal organic frameworks based on zirconium nodes (Zr-MOFs) have impressive adsorption capacities, and many can rapidly hydrolyze toxic organophosphorus nerve agents. They could thus potentially replace commonly used adsorbents in respiratory filters. However, current test methodologies are poorly adapted to screen the large number of available MOFs, and data for nerve agent adsorption by MOFs are scarce. This paper presents a miniaturized method for assessing the capacity of Zr-MOFs for dynamic gas phase adsorption and degradation of sarin (GB) into the primary hydrolysis product isopropyl methyl phosphonic acid (IMPA). The method was validated by comparing the dynamic adsorption capacities of activated carbon (AC) and NU-1000 for GB under dry and humid conditions. Under dry conditions, unimpregnated AC had a greater capacity for GB uptake (0.68 ± 0.06 g/g) than pelletized NU-1000 (0.36 ± 0.03 g/g). At 55% relative humidity (RH), the capacity of AC was largely unchanged (0.72 ± 0.10 g/g) but that of NU-1000 increased slightly, to 0.46 ± 0.10 g/g. However, NU-1000 exhibited poor water retention at 55% RH. For both adsorbents, the degree of hydrolysis of GB into IMPA was significantly greater at 55% RH than under dry conditions, but the overall degree of hydrolysis was limited in both cases. Further tests at higher relative humidities are needed to fully evaluate the ability of NU-1000 to degrade GB after adsorption from the gas phase. The proposed experimental setup uses very small amounts of both adsorbent material (20 mg) and toxic agent, making it ideal for assessing new MOFs. However, future methodological challenges are reliable generation of sarin at higher RH and exploring sensitive methods to monitor degradation products from nerve agents in real-time.

2.
Appl Biosaf ; 26(2): 58-65, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36034689

RESUMO

Background: The SARS-CoV-2 pandemic put the entire healthcare sector under severe strain due to shortages of personal protection equipment. A large number of new filtering mask models were introduced on the market, claiming effectiveness that had undergone little or no objective and reliable verifications. Methods and Materials: Filter materials were tested against sodium chloride particles according to the EN149 §7.9.2 standard for particle penetration. Particle counters were used to measure the particle penetration of the filtering mask models, resolved over sizes in the range of 27-1000 nm. Results: We report on the results for 86 different filtering mask models. The majority of the tested models showed <3% penetration, whereas almost one third (i.e., 27 of 86) of the models performed poorly. Discussion: Interestingly, the poorest performing masks showed a tendency to have worse filtering effectiveness for larger particles than for smaller sized particles, following the opposite tendency of the best filtering masks. Conclusion: Almost one third of the filtering mask models tested failed the specified pass criteria as specified in the temporary EU COVID-19 standard. This fact, and the high health risks of COVID-19, highlights the need for independent testing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...