Dement Geriatr Cogn Disord ; 31(3): 179-87, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21389719

RESUMO

BACKGROUND: Clock drawing is part of the Montreal Cognitive Assessment (MoCA) test but may have administration and scoring limitations. We assessed (1) the reliability of the MoCA clock criteria relative to a published error scoring approach, (2) whether command-only administration could distinguish dementia from cognitively intact individuals and (3) the value of adding a clock copy condition to the MoCA. METHODS: Three novice raters and clocks from dementia and control participants were used to assess the 3 aims. RESULTS: MoCA interrater and intrarater reliability were low (i.e. intraclass correlation coefficient = 0.12-0.31) and required repeat training. Clocks drawn to command classified dementia at chance. Inclusion of a copy condition demonstrated expected dementia subgroup patterns. CONCLUSION: Reliable clock scoring with MoCA criteria requires practice. Supplementing a clock copy to the standard MoCA test (takes <1 min) will improve dementia assessment.


Assuntos
Demência/diagnóstico , Programas de Rastreamento/métodos , Testes Neuropsicológicos/normas , Variações Dependentes do Observador , Desempenho Psicomotor , Idoso , Estudos de Casos e Controles , Competência Clínica , Demência/classificação , Demência/psicologia , Avaliação da Deficiência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade