Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
RSBO (Impr.) ; 12(1): 61-67, Jan.-Mar. 2015.
Artigo em Inglês | LILACS | ID: lil-782786

RESUMO

Introduction:Stone casts are used in dentistry to allow the confection of indirect restorations. Thus, gypsum dimensional stability is fundamental in order to achieve a precise fit between dental structure and restorative material.Objective: The purpose of the present study was to evaluate the hygroscopic linear expansion of commercially available gypsum products. Material and methods: Fifteen dental stones were analyzed (4 type II, 5 type III, 4 type IV and 2 type V), with n = 5. One hundred grams of each gypsum product were mixed following the respective manufacturers' recommendations for powder/water ratio and poured into a V-shape mold, connected to an expansion-measuring device. The hygroscopic expansion was evaluated during 120 min and the collected data was converted into percentage and compared to initial dimensions of the specimen. Results: All type II and V dental stones showed expansion values compatible to the ADA and ISO recommendations. Considering type III stones, only Rutenium 3 was compatible with the recommendations. For type IV, only Durone IV showed expansion values higher than that recommended by ADA, but lower than that of ISO recommendations.Conclusion: The hygroscopic linear expansion of gypsum products should be periodically controlled in order to ensure their precision and reliability to dental practice.

2.
RSBO (Impr.) ; 8(3): 287-293, Jul.-Sep. 2011. ilus, tab
Artigo em Inglês | LILACS | ID: lil-720316

RESUMO

Introduction and objective: Glass ionomer cement, which was first introduced in Dentistry in 1972, presents good qualities such as aesthetics, fluoride release and adhesion to dental tissues. Because of its preventive characteristics regarding to dental caries, glass ionomer cement has been used for Atraumatic Restorative Treatment (ART), as reported by Frencken and Holmgren 6, meeting the principles announced by the World Health Organization (WHO) for application to large population groups without regular access to dental care. Material and methods: In this present study, the abrasive wear strength of two glass-ionomer cements (Vidrion R® and ChemFlex®) was evaluated through toothbrushing machine. Classic® toothbrushes with soft bristles and Sorriso® dentifrice were also used for the study. Results: Student-t test showed significant difference between both groups, with tobs value = 9.4411 at p < 0.05. Conclusion: It can be concluded that the wear rate caused by toothbrush/dentifrice was higher for Vidrion R® (52.00 mg) than ChemFlex® (5.57 mg).

3.
Bauru; s.n; 2011. 91 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-865836

RESUMO

Neste estudo, foi avaliada a resistência ao desgaste abrasivo de uma resina composta, através de três diferentes métodos: do disco retificado, por escovação e do nanodurômetro. Nos dois primeiros métodos, foram utilizados 20 espécimes da resina Filtek Z250 (10 da cor Incisal e 10 da cor C4, ambos fotopolimerizados por 30 segundos cada) e 10 de polimetilmetacrilato (PMMA), atuando estes últimos como padrão de referência. Para os ensaios com o nanodurômetro, foi utilizado apenas um espécime de cada cor, assim como um único de PMMA, em cujas superfícies planas foram efetuadas sete medições, o que foi considerado equivalente a sete espécimes. No método do disco retificado, cada espécime de resina composta era confeccionado diretamente numa cavidade semicircular, localizada na periferia de um disco-suporte; os espécimes de PMMA consistiam em discos constituídos exclusivamente por este material; o desgaste de cada espécime era promovido por um disco de porcelana e seu conseqüente deslocamento era detectado por um palpador; assim, a taxa de desgaste era estabelecida, expressa em milímetros cúbicos por newton por segundo (mm3/N.s). No método de escovação, cada espécime cilíndrico ficava preso numa placa metálica, a qual era fixada no interior da máquina de escovação; sua perda de massa (em miligramas) era verificada através de uma balança analítica. No método do nanodurômetro, existiu apenas um espécime ci líndrico para cada condição, em cuja face plana superior eram feitos sete sulcos (equivalentes a sete espécimes); o coeficiente de atrito permitia estabelecer a respectiva resistência ao desgaste. Para cada método utilizado, os dados foram tratados estatisticamente, através de análise de variância (ANOVA) e de teste de Tukey. Pôde-se concluir que, através do disco retificado, a taxa de desgaste (em mm3/N.s) dos materiais foi: Incisal (0,6807) > C4 (0,5012) > PMMA (0,1439); que, através da escovação, a taxa de desgaste (em mg) foi de 5,40 para...


Abrasive wear of a composite resin, using three different methods (ground disc, toothbrushing and nanodurometer). The aim at this study was to evaluate the resistance to abrasive wear of a composite resin, using three different methods: ground disc, toothbrushing and nanodurometer. At the first two methods were employed 20 specimens of Filtek Z250 composite resin (10 of Incisal and 10 of C4, both the colors cured for 30 seconds each one) and 10 of polymethylmethacrylate (PMMA), the latter acting as a reference standard. For the tests with the nanodurometer it was used only one specimen of each color, as well as just one of PMMA, in whose flat surfaces seven measurements were made, what was considered equivalent to seven specimens. At the ground disc method, each composite resin specimen was directly made on a semicircular cavity located on the periphery of a supporting disc; PMMA specimens consisted of discs made up exclusively with this material; the wear of each specimen was promoted by a ceramic disc and its consequent displacement was detected by a sensor; thus, the wear rate was established, expressed in cubic millimeters per newton per second (mm3/N.s). At the toothbrushing method, each cylindrical specimen was trapped in a metal plate, which was fixed inside the machine brushing; its weight loss (in milligrams) was verified by an analytical balance. At the nanodurometer method, there was only one cylindrical specimen for each condition, in whose flat upper face seven grooves were made (what was equivalent to seven specimens); the coefficient of friction was used to establish its wear resistance. For each method, data were statistically analyzed by ANOVA and Tukey's test. It could be concluded that, by ground disc method, materials wear rate (in mm3/N.s) was Incisal (0.6807) > C4 (0.5012) > PMMA (0.1439); by brushing method, materials wear rate (in mg) was 5.40 for Incisal, 9.35 for C4 and 5.88 for PMMA, without significant difference...


Assuntos
Abrasão Dentária/etiologia , Escovação Dentária/efeitos adversos , Resinas Compostas/química , Testes de Dureza , Teste de Materiais , Polimerização , Propriedades de Superfície , Fatores de Tempo
4.
Innov. implant. j., biomater. esthet. (Impr.) ; 5(3): 13-18, set.-dez. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-588541

RESUMO

Neste trabalho de resistência à tração foi avaliada a eficiência de 4 agentes cimentantes (fosfato de zinco S. S. White, ionômero de vidro Ketac Cem Easymix, resina composta/ionômero de vidro RelyX Luting 2 e resina acrílica especial Panavia 21 TC) usados para fixar coroas totais de NiCr a munhões tronco-cônicos, usinados em liga de Ti-6Al-4V. Foram utilizados 40 munhões, distribuídos em grupos de 10, para cada material. Os ensaios mecânicos foram realizados em uma máquina universal MTS 810, na velocidade de 0,5 mm/min. A respectiva Análise de Variância (ANOVA) apontou existir diferença significante entre os grupos e o teste de Tukey (p < 0,05) também mostrou diferenças significantes entre eles, exceto nas comparações fosfato versus RelyX e fosfato versus Ketac Cem. O melhor desempenho foi apresentado pela resina Panavia 21 (1.127,996 N); a resina composta/ionômero de vidro RelyX (478,197 N) mostrou comportamento similar apenas ao do fosfato (430,662 N), o qual apresentou desempenho semelhante ao ionômero de vidro Ketac Cem (227,705 N).


In this work of tensile strength was evaluated the efficacy of 4 cements (S. S. White zinc phoshate, Ketac Cem Easymix glass ionomer, RelyX Luting 2 composite resin/glass ionomer and Panavia 21 TC special acrylic resin) used to fix NiCr crowns to usinated titanium alloy abutments. Were used 40 abutments distributed in groups of 10 elements, to each material. The mechanical essays were developed at a MTS 810 universal machine, adjusted to a 0.5 mm/m velocity. The ANOVA applied to data pointed out the existence of significant differences between groups; the subsequent Tukeyïs test (p<0.05) also detected significant differences, except at comparisons of phosphate versus RelyX and phosphate versus Ketac Cem. The better performance was presented by Panavia 21 (1,127.996 N); RelyX (478.197 N) showed itself similar only to phosphate (430.662 N), wich had a performance similar to that of Ketac Cem (227.705 N).


Assuntos
Cimentação , Implantes Dentários , Resistência à Tração
5.
Innov. implant. j., biomater. esthet. (Impr.) ; 5(2): 35-39, maio-ago. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-581345

RESUMO

Por meio de tração, coroas totais de NiCr foram removidas de munhões pré-fabricados, compostos por uma liga de Ti6Al-4V. Num total de 20 munhões, 10 foram usados com sua superfície original e 10 com sua superfície modificada por laser, ambos cimentados com fosfato do zinco. O teste mecânico foi executado em uma máquina universal MTS 810 ajustada a uma velocidade de 0,5 mm/min. A análise estatística foi feita pelo teste de Levene, o qual mostrou homogeneidade de variâncias entre os grupos (F = 2,21; p < 0,1). O subsequente teste "t" de Student mostrou haver diferenças significantes entre os grupos. A modificação da superfície dos munhões através do laser causou um aumento na resistência à tração das coroas cimentadas com fosfato de zinco, de 430,66 para 1.514,87 N.


By means of tensile strength, NiCr total crowns were removed from machine-made conical abutments composed by an Ti-6Al-4V alloy. In a total of 20 abutments, 10 were used with it surface presenting high smoothness and 10 abutments had its surfaces modified by laser both cemented with zinc phosphate. The mechanical test was performed at a MTS 810 universal machine adjusted to a speed of 0.5 mm/m. The statistical analysis was done by Levene's test, which showed homogeneity of variances among groups (F =2.21; p < 0.1). "Student t test" showed that significant differences were found between groups. The modification of the abutment surface through laser caused an increase in pull-out resistance of crowns cemented with zinc phosphate from 430.66 N to 1.514,87 N.


Assuntos
Cimentação , Implantes Dentários , Resistência à Tração
6.
Rev. Fac. Odontol. Lins (Impr.) ; 21(1): 7-14, jan.-jun. 2009. ilus, graf, tab
Artigo em Português | BBO - Odontologia | ID: biblio-856494

RESUMO

O cisalhamento por puncionamento é um método simples e eficaz para avaliar a resistência de um material por meio de uma carga axial aplicada para deslocar um ou vários materiais entre si. Dessa forma, o objetivo deste trabalho foi avaliar três agentes cimentantes (fosfato de zinco, ionômero de vidro e cimento resinoso), em relação ás resistências ao cisalhamento por puncionamento. Para o ensaio, foram confeccionados espécimes em uma matriz em forma de anel com dimensões de 14 mm de diâmentro interno de 1,5 mm de altura, que permitia obter um corpo de prova em formato de disco. Um conjunto matriz-cimento foi posicionado num dispositivo próprio para o teste. Dez espécimes de cada material foram avaliados em dois períodos de uma hora e 24 horas. Os resultados foram tratados estatisticamente com Análise de Variância a dois critérios (ANOVA), seguida do teste comparativo de Tukey, em nível de significância de 5 por cento. Dentre os agentes cimentantes avaliados nos dois períodos, o cimento resinoso apresentou os maiores valores de resistência ao puncionamento, e o cimento de ionômero de vidro, os menores


Assuntos
Cimentos Dentários , Materiais Dentários , Restauração Dentária Permanente , Resistência ao Cisalhamento
7.
J. appl. oral sci ; 16(1): 7-11, Jan.-Feb. 2008. ilus, tab
Artigo em Inglês | LILACS | ID: lil-472682

RESUMO

The purpose of this study was to evaluate the accuracy of the respective dies after polyether elastomeric procedure in the presence or absence of cervical contact of the acrylic resin shell with the cervical region, establishing a comparison to dies obtained with stock trays. This study consisted of three groups with 10 specimens each: 1) acrylic copings without cervical contact, (cn); 2) acrylic copings with cervical contact (cc); 3) perforated stock tray, (st). The accuracy of the resulting dies was verified with the aid of a master crown, precisely fit to the master steel die. ANOVA test found statistically significant differences among groups (p<0.001). Tukey's test found that the smallest discrepancy occurred in group cn, followed by cc, while the st group presented the highest difference (cc x cn: p=0.007; st x cn: p<0.001; st x cc: p<0.001).


Assuntos
Humanos , Resinas Acrílicas/química , Coroas , Sulfato de Cálcio/química , Dente Suporte , Modelos Dentários , Planejamento de Prótese Dentária , Reembasamento de Dentadura , Materiais para Moldagem Odontológica/química , Materiais Dentários/química , Elastômeros/química , Ligas de Cromo/química , Técnica de Moldagem Odontológica/instrumentação , Teste de Materiais , Metilmetacrilatos/química , Resinas Sintéticas/química , Propriedades de Superfície , Aço Inoxidável/química , Preparo Prostodôntico do Dente/classificação
8.
Rev. Odontol. Araçatuba (Impr.) ; 28(3): 16-23, set.-dez. 2007. tab
Artigo em Português | BBO - Odontologia | ID: biblio-856810

RESUMO

A dureza é um importante aspecto dentre as características dos materiais, sendo indicativa de algumas outras propriedades mecânicas, inclusive para as resinas compostas. No presente trabalho, foi avaliada a dureza Vickers de 29 compósitos, nos quais a fotoativação sempre foi de 80 segundos. Em cada um dos 3 corpos-de- prova de cada material, a dureza denominada inicial era aquela verificada na idade de 15 minutos; a dureza final era determinada após aquele mesmo espécime ter sido armazenado em água desionizada, a 37ºC, durante 168 horas. O tratamento estatístico dos dados permitiu constatar que a dureza final foi maior que a inicial apenas em 20 das resinas analisadas. Os maiores valores de dureza final foram detectados nas resinas Filtek Z-100 e Filtek P-60, que apresentaram valores estatisticamente semelhantes entre si, enquanto os menores foram observados nas resinas Helioprogress, Amelogen Micro Fill, Durafill VS, Heliomolar e Silux Plus, também de comportamento estatisticamente semelhante


Between the characteristics of materials, surface hardness is an important factor, presumably indicative of some others properties, inclusively for composite resins. At this paper, Vickers hardness of 29 composite resins was determined, always after a polymerization time of 80 seconds. At each one of the 3 specimens from each material, hardness denominated initial was that measured at the age of 15 minutes; final hardness was that measured after that same specimen stay immersed in deionized water, at 37ºC by 168 hours. Statistical treatment of data showed that final hardness was greater than initial only in 20 of the studied resins. The largest values of final hardness were detected to Filtek Z-100 and Filtek P-60, with statistically similar values between themself, while the smallest were obtained with Helioprogress, Amelogen Micro Fill, Durafill VS, Heliomolar and Silux Plus, equally with similar values


Assuntos
Materiais Dentários , Resinas Compostas , Testes de Dureza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...