Despite an increase of literature data on Legionella spp. presence in private water systems, epidemiological reports assert a continuing high incidence of Legionnaires' disease infection in Italy. In this study, we report a survey on Legionella spp. colonization in 58 buildings with solar thermal systems for hot water production (TB). In all buildings, Legionella spp. presence was enumerated in hot and cold water samples. Microbiological potability standards of cold water were also evaluated. Legionella spp. was detected in 40% of the buildings. Moreover, we detected correlations between the count of Legionella spp. and the presence of the optimal temperature for the microorganism growth (less than 40 °C). Our results showed that cold water was free from microbiological hazards, but Legionella spp., was detected when the mean cold water temperature was 19.1 ± 2.2 °C. This may considered close to the suboptimal value for the Legionella growth (more then 20 °C). In conclusion, we observed the presence of a Legionnaires' disease risk and the need of some strategies aimed to reduce it, such as the application of training programs for all the workers involved in water systems maintenance.


Assuntos
Temperatura Alta , Legionella/isolamento & purificação , Doença dos Legionários/prevenção & controle , Água/parasitologia , Humanos , Itália/epidemiologia , Legionella/classificação , Legionella pneumophila , Temperatura , Microbiologia da Água , Abastecimento de Água
2.
Ig Sanita Pubbl ; 75(4): 303-312, 2019.
Artigo em Italiano | MEDLINE | ID: mdl-31887736

RESUMO

The term asbestos refers to six unique fibrous minerals mostly used in the production of asbestos cement sheets and pipes. According to the World Health Organization and the International Agency for Research on Cancer (IARC), there exists at least "sufficient evidence" that all types of asbestos may cause cancer in humans (mesothelioma, lung cancer, laryngeal tumor and ovarian cancer). The only asbestos limit in drinking water is 7 million fiber/liter. This study is a narrative synthesis about the possible hazards to human health related to the presence of asbestos in drinking water. The various scientific studies and epidemiological reports examined highlight that there is an ongoing debate on the possible carcinogenic risk associated with asbestos exposure through ingestion. Nevertheless, considering the latency with which diseases caused by asbestos may emerge, control measures should be adopted.


Assuntos
Amianto/efeitos adversos , Água Potável/análise , Exposição Ambiental/efeitos adversos , Poluentes Químicos da Água/toxicidade , Amianto/toxicidade , Carcinógenos , Humanos , Neoplasias Pulmonares/etiologia , Neoplasias Pulmonares/prevenção & controle , Mesotelioma/etiologia , Mesotelioma/prevenção & controle
3.
J Water Health ; 17(3): 490-498, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31095523

RESUMO

Although in Europe the quality of swimming pools (SPs) is dictated by regulations, microbiological and chemical hazards are described in the literature. Environmental bacteria or toxic disinfection by-product (DBP) compounds may indeed be recovered in waters even after disinfection. We evaluated the water quality from 26 outdoor seasonal SPs of the Versilia district, according to requirements of Regional Decree 54R/2015. In spring 2017, supply and reinstatement waters were collected after shock hyperchlorination (10 mg/L) while in summertime, a second sampling of waters before entering the pools, as well as in the pools, was performed after SPs were open to the public. In all samples, microbiological and chemical parameters were determined as defined by Directive 98/83/EC and the Italian Health Ministry. Microbiological data were within suggested limits. The first chemical analyses showed that in 35% of the feeding-pool seawater samples, the halogenated organic compounds were higher than the maximum permissible concentrations (30 µg/L). Pool waters were then dechlorinated and re-treated with hydrogen peroxide (10 mg/L) to ensure the abatement of DBPs (from 164 ± 107 to 0.9 ± 0.8 µg/L; p = 0.002). Results highlighted the need of self-controlled procedures for the SPs waters to prevent waterborne diseases and suggested hydrogen peroxide as the most appropriate disinfection method.


Assuntos
Desinfetantes/análise , Piscinas/estatística & dados numéricos , Poluentes Químicos da Água/análise , Desinfecção , Itália , Estações do Ano
4.
Pathogens ; 8(1)2019 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-30650590

RESUMO

International literature data report that the increase of infectious risk may be due to heating, ventilation and air conditioning (HVAC) systems contaminated by airborne pathogens. Moreover, the presence of complex rotating dehumidification wheels (RDWs) may complicate the cleaning and disinfection procedures of the HVAC systems. We evaluated the efficacy of a disinfection strategy applied to the RDW of two hospitals' HVAC systems. Hospitals have four RDW systems related to the surgical areas (SA1 and SA2) and to the intensive and sub-intensive care (IC and sIC) units. Microbiological air and surface analyses were performed in HVAC systems, before and after the disinfection treatment. Hydrogen peroxide (12%) with silver ions (10 mg/L) was aerosolized in all the air sampling points, located close to the RDW device. After the air disinfection procedure, reductions of total microbial counts at 22 °C and molds were achieved in SA2 and IC HVAC systems. An Aspergillus fumigatus contamination (6 CFU/500 L), detected in one air sample collected in the IC HVAC system, was eradicated after the disinfection. The surface samples proved to be of good microbiological quality. The results suggest the need for a disinfection procedure to improve the microbiological quality of the complex HVAC systems, mostly in surgical and intensive care areas.

5.
Ig Sanita Pubbl ; 74(1): 71-86, 2018.
Artigo em Italiano | MEDLINE | ID: mdl-29734324

RESUMO

In this paper we describe the laws and rules applying to swimming pools. Authorization activity title for recreational swimming pools is regulated according to articles 80 and 86 of the TULPS R.D.n°773/1931. In Regione Toscana periodic management of the hygienic requirements for swimming pools is regulated by Regional Decree 54R/2015. It requires the evaluation of physical-chemical and microbiological indicators. The law applies to structural and organizational requirements of swimming pools as well as defines responsabilities of managers.


Assuntos
Higiene , Saúde Pública , Piscinas/legislação & jurisprudência , Piscinas/normas , Qualidade da Água/normas , Humanos , Higiene/legislação & jurisprudência , Água/análise , Microbiologia da Água
6.
Artigo em Inglês | MEDLINE | ID: mdl-29072607

RESUMO

Although the European reports highlight an increase in community-acquired Legionnaires' disease cases, the risk of Legionella spp. in private houses is underestimated. In Pisa (Italy) we performed a three-year survey on Legionella presence in 121 buildings with an independent hot water production (IB); 64 buildings with a central hot water production (CB); and 35 buildings with a solar thermal system for hot water production (TB). From all the 220 buildings Legionella spp. was researched in two hot water samples collected either at the recirculation point or on the first floor and on the last floor, while the potable water quality was analysed in three cold water samples collected at the inlet from the aqueduct network, at the exit from the autoclave, and at the most remote tap. Legionella pneumophila sg1, Legionella pneumophila sg2-16, and non-pneumophila Legionella species were detected in 26% of the hot water networks, mostly in CB and TB. In these buildings we detected correlations between the presence of Legionella and the total chlorine concentration decrease and/or the increase of the temperature. Cold water resulted free from microbiological hazards, with the exception of Serratia liquefaciens and Enterobacter cloacae isolated at the exit from two different autoclaves. We observed an increase in total microbial counts at 22 °C and 37 °C between the samples collected at the most remote taps compared to the ones collected at the inlet from the aqueduct. The study highlights a condition of potential risk for susceptible categories of population and supports the need for measures of risk assessment and control.


Assuntos
Habitação , Legionella/isolamento & purificação , Poluentes da Água/isolamento & purificação , Abastecimento de Água , Cloro/análise , Desinfetantes/análise , Água Potável/microbiologia , Monitoramento Ambiental , Temperatura Alta , Itália , Esterilização , Microbiologia da Água