Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
J Dairy Sci ; 104(4): 4904-4913, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33551159

RESUMO

The objective of this study was to identify the calf-level colostrum management practices associated with an adequate transfer of passive immunity (TPI; defined as serum Brix refractance ≥8.4% in the first week of life) in small-sized herds. A total of 818 calves from 61 commercial Holstein dairy farms were included in this observational cross-sectional study. For each calf, sex, colostrum delivery method, colostrum volume fed at first meal, and time to first feeding (delay between birth and first colostrum meal) were noted. Blood and colostrum samples were collected to estimate the serum and colostrum quality using Brix refractometry. To quantify the level of bacterial contamination in colostrum samples, total bacteria count and total coliform count (TCC) were measured using the Petrifilm (3M, St. Paul, MN) culture system. In this study, 68% of calves had an adequate TPI (≥8.4%). For data distribution, the 25th, 50th, and 75th percentiles were 1.3, 2.8, and 3.3 L for the colostrum volume fed at the first meal; 20.9, 23.5, and 26.5% Brix; and 1.1, 3.1, and 6.5 h for the time to first feeding of colostrum, respectively. The odds of adequate TPI were 2.6 times higher in calves receiving ≥2.5 L colostrum at their first meal, 2.9 times higher in calves receiving colostrum with ≥24.5% Brix, and 1.6 times higher in calves receiving colostrum within 3 h after birth, than in calves not meeting these criteria. In the present study, median bacterial contamination distribution (interquartile range) in the first colostrum meal was 14,000 cfu/mL (3,000-83,000 cfu/mL) for total bacteria count, and 0 cfu/mL (0-1,000 cfu/mL) for TCC. Total bacteria count and TCC were not associated with the odds of adequate TPI in the final model. Overall, these results suggest that specific calf-level colostrum management practices are associated with adequate TPI in small- to medium-sized dairy herds.


Assuntos
Colostro , Parto , Animais , Animais Recém-Nascidos , Bovinos , Fazendas , Feminino , Gravidez , Quebeque , Refratometria/veterinária
2.
J Dairy Sci ; 104(4): 4914-4922, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33516548

RESUMO

The objective of this study was to identify herd-level colostrum management factors associated with the adequate transfer of passive immunity (TPI; defined as serum Brix refractance ≥8.4% in the first week of life). A total of 59 commercial Holstein dairy farms were included in this observational cross-sectional study. In every participating herd, a minimum of 14 Holstein calves were sampled to measure their TPI using a digital Brix refractometer. Colostrum samples fed to each of these calves were collected to estimate IgG concentration (colostrum quality) using a digital Brix refractometer and bacterial contamination using the Petrifilm (3M, St. Paul, MN) culture system. Dairy producers completed a questionnaire on colostrum management to assess on-farm practices. The study outcome was the prevalence of adequate TPI calculated based on the proportion of adequate TPI (defined with an individual threshold ≥8.4% Brix) on the total samples tested within each herd. According to the threshold determined in a previous study investigating the influencing colostrum management factors to achieve adequate TPI at the calf level, the prevalence of an adequate colostrum volume fed at first meal (≥2.5 L), the prevalence of adequate colostrum quality (≥24.5% Brix), the prevalence of an adequate time to first feeding (delay between birth and the first colostrum meal, ≤3 h), the prevalence of low aerobic bacterial contamination (≤20,000 cfu/mL), the prevalence of low coliform contamination (≤1,000 cfu/mL), and the prevalence of females were calculated. The herd-level prevalence of adequate TPI ranged from 24% to 100%, with a median of 68%. The median herd prevalences of an adequate colostrum volume fed at first meal, of adequate colostrum quality, of an adequate time to first feeding, of low aerobic bacterial contamination, of low coliform contamination, and of females, were 71, 42, 41, 64, 88, and 61%, respectively. In the final model, the prevalence of adequate TPI was associated with the prevalence of an adequate colostrum volume fed at first meal and the prevalence of an adequate time to first feeding. In summary, management practices varied greatly between farms and influenced the prevalence of adequate TPI.


Assuntos
Colostro , Parto , Animais , Animais Recém-Nascidos , Bovinos , Fazendas , Feminino , Gravidez , Prevalência , Quebeque
3.
J Dairy Sci ; 104(4): 4923-4928, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33358819

RESUMO

The objective of this study was to validate the diagnostic accuracy of the Petrifilm culture system (3M, St. Paul, MN) for identifying colostrum with excessive bacterial contamination. An observational cross-sectional study was conducted between October 2015 and February 2016. Two colostrum aliquots were collected during the first meal of 332 calves (33 commercial Holstein dairy farms) in Quebec, Canada. One aliquot per calf was used to quantify the total bacteria count and the total coliform count using standard bacteriological laboratory testing (reference test). These results were dichotomized to identify colostrum with excessive bacterial contamination [aerobic count plate (AC) >100,000 cfu/mL; coliform count plate (CC) >10,000 cfu/mL]. The Petrifilm system was used to quantify both aerobic and coliform contamination of the other colostrum aliquot from each calf. As such, AC and CC were used according to the manufacturer's recommendations. The area under the curve of the receiver operating characteristic curve of AC and CC compared with the laboratory were 0.83, and 0.95, respectively. Using the optimal threshold of >24,000 cfu/mL for AC results, the Petrifilm system had a sensitivity (Se) of 69%, specificity (Sp) of 86%, and a kappa value of 0.54. Using the optimal threshold of >4,000 cfu/mL for CC results, the Petrifilm system had a Se of 93%, Sp of 90%, and kappa value of 0.64. Overall, these results suggest that the Petrifilm system is an appropriate alternative for identifying colostrum with excessive bacterial contamination.


Assuntos
Colostro , Animais , Canadá , Bovinos , Estudos Transversais , Fazendas , Feminino , Gravidez , Quebeque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...