Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-34690392

RESUMO

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a 'Switchillator', that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

2.
Rev Sci Instrum ; 91(5): 053105, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32486706

RESUMO

We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCP-PMT) using the "air-transfer" assembly process developed with single LAPPDTM modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside the vacuum tube and of hermetically sealing the large-perimeter window-body interface. We have also synthesized a photocathode in a large-area low-aspect-ratio volume and have shown that the micro-channel plates recover their functionality after cathode synthesis. These steps inform a design for a multi-module batch facility employing dual nested low-vacuum and ultra-high-vacuum systems in a small-footprint. The facility design provides full access to multiple MCP-PMT modules prior to hermetic pinch-off for leak-checking and real-time photocathode optimization.

3.
Proc Natl Acad Sci U S A ; 90(21): 9754-7, 1993 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-11607432

RESUMO

In a colliding beam accelerator such as Fermilab or the Superconducting Supercollider (SSC) protons, or antiprotons, collide at a rate between 10(5) (Fermilab) and 10(8) (SSC) collisions per second. In real time experimentalists have to select those events which are candidates for exploring the limit of known phenomena at a much lower rate, 1-100 per second, for recording on permanent media. The rate of events from new physics sources is expected to be much lower, as low as a few per year. This is a severe problem in pattern recognition: with an input data stream of up to 10(15) potential bits per second in its images, we have to pick out those images that are potentially interesting in real time at a discrimination level of 1 part in 10(6), with a known efficiency. I will describe the overall filtering strategies and the custom hardware to do this event selection (a.k.a. pattern recognition).

4.
Zentralbl Chir ; 117(6): 348-50, 1992.
Artigo em Alemão | MEDLINE | ID: mdl-1519394

RESUMO

In 500 mamma needle biopsies that were cytologically examined we found a precision of 87.4%, with 2.6% false negative, and 6.2% false positive results. In 19 cases a cytological diagnosis was not possible resulting in a sensitivity of 0.94 and a specificity of 0.86. False positive findings were due to misinterpretations of the cytological pictures, as were also false negative findings. In the latter cases sampling mistakes could also be the reason. Cytological diagnostic should only be made using triple diagnostic technique since the methods are complementary to each other in respect to their diagnostic security. Practical experience in the puncturing technique as well as an experienced cytologist are prerequisites using this method successfully as a diagnostic tool.


Assuntos
Neoplasias da Mama/patologia , Doença da Mama Fibrocística/patologia , Lesões Pré-Cancerosas/patologia , Biópsia por Agulha , Mama/patologia , Diagnóstico Diferencial , Feminino , Humanos , Mamografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...