Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Neurosurg Rev ; 46(1): 61, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36849823

RESUMO

Lateral mass screw (LMS) and cervical pedicle screw (CPS) fixation are among the most popular techniques for posterior fusion of the cervical spine. Early research prioritized the LMS approach as the trajectory resulted in fewer neurovascular complications; however, with the incorporation of navigation assistance, the CPS approach should be re-evaluated. Our objective was to report the findings of a meta-analysis focused on comparing the LMS and CPS techniques in terms of rate of various complications with inclusion of all levels from C2 to T1. We conducted a systematic review of PubMed and EMBASE databases with final inclusion criteria focused on identifying studies that reported outcomes and complications for either the CPS or LMS technique. These studies were then pooled, and statistical analyses were performed from the cumulative data. A total of 60 studies comprising 4165 participants and 16,669 screws placed within the C2-T1 levels were identified. Within these studies, the LMS group had a significantly increased odds for lateral mass fractures (odds ratio [OR] = 43.2, 95% confidence interval [CI] = 2.62-711.42), additional cervical surgeries (OR = 5.56, 95%CI = 2.95-10.48), and surgical site infections (SSI) (OR = 5.47, 95%CI = 1.65-18.16). No other significant differences between groups in terms of complications were identified. Within the subgroup analysis of navigation versus non-navigation-guided CPS placement, no significant differences were identified for individual complications, although collectively significantly fewer complications occurred with navigation (OR = 5.29, 95%CI = 2.03-13.78). The CPS group had significantly fewer lateral mass fractures, cervical revision surgeries, and SSIs. Furthermore, navigation-assisted CPS placement was associated with a significant reduction in complications overall.


Assuntos
Vértebras Cervicais , Parafusos Pediculares , Fusão Vertebral , Humanos , Vértebras Cervicais/cirurgia , Parafusos Pediculares/efeitos adversos , Reoperação , Infecção da Ferida Cirúrgica , Fusão Vertebral/efeitos adversos , Fusão Vertebral/instrumentação
2.
Interv Neuroradiol ; 29(5): 605-608, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35471853

RESUMO

We present a case of acute onset of blindness treated with venous sinus stenting in the hyperacute period (24-48 h). The patient had not been diagnosed previously with idiopathic intracranial hypertension and presented at an outside facility with a short history of headache, nausea, vomiting and visual deficits. Initial management included lumbar punctures for pressure relief. Unfortunately, the patient's condition deteriorated and she experienced the rapid onset of blindness. Within 24-48 h of blindness onset, she was transferred to our institution for emergent endovascular stenting of the venous sinuses. The intervention resulted in improvement of symptoms and recovery of visual acuity over a short-term follow-up period.


Assuntos
Hipertensão Intracraniana , Pseudotumor Cerebral , Feminino , Humanos , Pseudotumor Cerebral/complicações , Pseudotumor Cerebral/diagnóstico por imagem , Pseudotumor Cerebral/cirurgia , Cegueira/etiologia , Cegueira/terapia , Stents , Cavidades Cranianas/cirurgia , Hipertensão Intracraniana/diagnóstico por imagem , Hipertensão Intracraniana/etiologia , Hipertensão Intracraniana/terapia
3.
Global Spine J ; 13(7): 1992-2000, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35195035

RESUMO

STUDY DESIGN: Cadaver study. OBJECTIVES: Assess the feasibility of robot-assisted cervical pedicle screw (RA-CPS) placement and understand the anatomical considerations of this technique. METHODS: Four cadaver specimens free from bony pathology were acquired. Anatomical considerations, such as pedicle width (PW) and height (PH), transverse pedicle angle (TPA), and maximal screw length (MSL), were recorded from preoperative computational tomography (CT) scans. Intraoperative cone-beam CT was acquired and registered to the robotic system. After cervical levels were segmented, screw sizes and trajectories were planned, and RA-CPS were placed. Accuracy was assessed using Gertzbein and Robbin's classification on postoperative CT scans. RESULTS: Thirty-five RA-CPS were placed. Major breaches (≥Grade C) occurred in 28.57% screws. Grade A or B accuracy was found in 71.43% of screws, with the most common direction of breach being medial (81.3%). The greatest proportion of breach per level occurred in the upper subaxial levels, (C3:71.4%, C4 66.6%, C5:50%) which had the smallest PW (C3: 4.34 ± .96 mm, C4: 4.48 ± .60, C5: 5.76 ± 1.11). PH was greatest at C2 (8.14 ± 1.89 mm) and ranged subaxial from 6.36 mm (C3) to 7.48 mm (C7). The mean PW was 5.37 mm and increased caudally from 4.34 mm (C3) to 6.31 mm (C7). The mean TPA was 39.9° and decreased moving caudally 46.9°) to C7 (34.4°). The MSL was 37.1 mm and increased from C2 (26.3 mm) to C7 (41.0 mm). CONCLUSION: RA-CPS has the potential to be feasible, but technological and instrument modifications are necessary to increase the accuracy in the cervical region.

4.
J Neurointerv Surg ; 15(10): 943-947, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36137743

RESUMO

BACKGROUND: Literature on volumetric resolution and recurrence over time between surgical evacuation alone (SEA) and standalone middle meningeal artery embolization (MMAE) in comparable chronic subdural hematoma (cSDH) patients is limited. METHODS: A retrospective database analysis of cSDH patients managed with either SEA or MMAE was conducted. Propensity-score matching was performed for axial and coronal lengths, maximum diameter, and midline shift. Volumetric measurements at multiple time intervals and recurrence were compared between the groups. RESULTS: 48 matched hematoma pairs in patients with similar demographics, comorbidities, medications, and symptoms were obtained. Median volume was significantly lower at 24 hours in the SEA group (12.6 mL vs 52.7 mL, p<0.001) but not at remaining intervals. Median volume reduction was significantly greater in the SEA group at 24 hours (39.1 mL vs 8.8 mL in the MMAE group, p<0.001) and at 3-12 weeks (50.8 mL vs 23.7 mL, p<0.001), but not at remaining intervals. The SEA group had a significantly greater median hematoma resolution rate at 24 hours (39.1 mL/day vs 8.8 mL/day, p<0.001) and 3-12 weeks (1 mL/day vs 0.4 mL/day, p<0.001), but not at remaining intervals. Near-complete resolution at 3-12 weeks and 12-60 weeks was not significantly different between groups. Overall, the recurrence rate was significantly higher in the SEA group (22.9% vs 4.2%, p=0.01). CONCLUSIONS: In comparable cSDH patients, SEA resulted in better volumetric outcomes in immediate postoperative and early follow-up periods, as expected. However, this difference was not significant at more distant follow-up intervals. Furthermore, surgical patients experienced a significantly higher rate of recurrence.


Assuntos
Embolização Terapêutica , Hematoma Subdural Crônico , Humanos , Estudos Retrospectivos , Hematoma Subdural Crônico/diagnóstico por imagem , Hematoma Subdural Crônico/cirurgia , Artérias Meníngeas/diagnóstico por imagem , Artérias Meníngeas/cirurgia , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos
5.
World Neurosurg ; 168: e376-e380, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36243361

RESUMO

BACKGROUND: Statins have been reported to reduce the rates of recurrence and improve the resolution of chronic subdural hematomas (cSDHs) treated surgically or conservatively. No studies have investigated the effect of statins in patients treated with middle meningeal artery embolization. METHODS: We performed a retrospective search of our cSDH database to identify patients treated with middle meningeal artery embolization alone. Only patients with at least 1 noncontrast computed tomography scan obtained 3-12 weeks after embolization were included. Hematoma volumes were measured at baseline and last noncontrast computed tomography available. The volumes, volume reduction, speed of resolution, and recurrence were compared between patients already receiving statin therapy when admitted and those who were not. RESULTS: Forty-six patients with 50 cSDHs were included (statins, 17 patients with 18 cSDHs vs. nonstatins, 29 patients with 32 cSDHs). The statin group had a significantly higher rate of hyperlipidemia (statin, 64.7% vs. nonstatin, 31%, P = 0.03) but similar demographics, remaining comorbidities, medications, and hematoma thickness, axial and coronal lengths, and baseline volumes. The time between procedure and last noncontrast computed tomography scan was similar between groups. There were no differences between the groups regarding volume reduction, final volume, speed of resolution, complete resolution, and recurrence. CONCLUSIONS: Patients treated with middle meningeal artery embolization alone who were on statin therapy had no differences in cSDH resolution or recurrence compared to those who were not on statin therapy. It is possible that the anti-inflammatory effects of statins may not be relevant when supply to the dura is interrupted by treatment with embolization.


Assuntos
Embolização Terapêutica , Hematoma Subdural Crônico , Inibidores de Hidroximetilglutaril-CoA Redutases , Humanos , Artérias Meníngeas/diagnóstico por imagem , Hematoma Subdural Crônico/diagnóstico por imagem , Hematoma Subdural Crônico/terapia , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Estudos Retrospectivos , Embolização Terapêutica/métodos , Hematoma/terapia
6.
Neurosurg Rev ; 45(3): 1941-1950, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35138485

RESUMO

Lateral mass screw (LMS) fixation for the treatment of subaxial cervical spine instability or deformity has been traditionally associated with few neurovascular complications. However, cervical pedicle screw (CPS) fixation has recently increased in popularity, especially with navigation assistance, because of the higher pullout strength of the pedicle screws. To their knowledge, the authors conducted the first meta-analysis comparing the complication rates during and/or after CPS and LMS placement for different pathologies causing cervical spine instability. A systematic literature search of PubMed and Embase from inception to January 12, 2021 was performed to identify studies reporting CPS and/or LMS-related complications. Complications were categorized into intraoperative and early postoperative (within 30 days of surgery) and late postoperative (after 30 days from surgery) complications. All studies that met the prespecified inclusion criteria were pooled and cumulatively analyzed. A total of 24 studies were conducted during the time frame of the search and comprising 1768 participants and 8636 subaxially placed screws met the inclusion criteria. The CPS group experienced significantly more postoperative C5 palsy (odds ratio [OR] = 3.48, 95% confidence interval [CI] = 1.27-9.53, p < 0.05). Otherwise, there were no significant differences between the LMS and CPS groups. There were no significant differences between the CPS and LMS groups in terms of neurovascular procedure-related complications other than significantly more C5 palsy in the CPS group.


Assuntos
Parafusos Pediculares , Doenças da Coluna Vertebral , Fusão Vertebral , Vértebras Cervicais/cirurgia , Humanos , Paralisia , Parafusos Pediculares/efeitos adversos , Doenças da Coluna Vertebral/cirurgia , Fusão Vertebral/efeitos adversos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
World Neurosurg ; 146: e6-e13, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32956893

RESUMO

BACKGROUND: Lumbar spine fusion surgery is traditionally performed with rigid fixation. Because the rigidity is often supraphysiologic, semirigid rods were developed. To the best of our knowledge, a comprehensive evaluation of rod material type on surgical outcomes has yet to be conducted. METHODS: A systematic review based on PRISMA guidelines was conducted across 3 electronic databases. After examination for inclusion and exclusion criteria, data were extracted from the studies. RESULTS: Seventeen studies, including 1399 patients, were included in this review. The mean rigid rod fusion rate is 92.2% and 95.5% for semirigid rods (P = 0.129). The mean improvement in back pain was 60.6% in rigid rods and 71.6% in semirigid rods. The improvement in leg pain was 81.9% and 77.2%, respectively. There were no differences in visual analog scale back pain score (P = 0.098), visual analog scale leg pain score (P = 0.136), or in functional improvement between rigid and semirigid rods (P = 0.143). There was no difference (P = 0.209) in the reoperation rate between rigid rods (13.1%) and semirigid rods (6.5%). There was a comparable incidence of adjacent segment disease (3%), screw fracture (1.7%), and wound infection (1.9%) between rod material types. CONCLUSIONS: There is a moderate level of evidence supporting that surgical intervention results in high fusion rates regardless of rod material type. Surgical intervention improves back pain, leg pain, and function, with neither material type showing clear superiority. There are comparable rates of reoperation, development of adjacent segment disease, development of mechanical complications, and incidence of infection in both rigid and semirigid rods. Further studies regarding rod material type are warranted.


Assuntos
Dor nas Costas/cirurgia , Parafusos Ósseos , Vértebras Lombares/cirurgia , Fusão Vertebral , Parafusos Ósseos/efeitos adversos , Humanos , Polietilenoglicóis/uso terapêutico , Fusão Vertebral/métodos , Resultado do Tratamento
8.
J Pathol ; 248(3): 339-351, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30883742

RESUMO

Exon skipping is a promising genetic therapeutic strategy for restoring dystrophin expression in the treatment of Duchenne muscular dystrophy (DMD). The potential for newly synthesized dystrophin to trigger an immune response in DMD patients, however, is not well established. We have evaluated the effect of chronic phosphorodiamidate morpholino oligomer (PMO) treatment on skeletal muscle pathology and asked whether sustained dystrophin expression elicits a dystrophin-specific autoimmune response. Here, two independent cohorts of dystrophic mdx mice were treated chronically with either 800 mg/kg/month PMO for 6 months (n = 8) or 100 mg/kg/week PMO for 12 weeks (n = 11). We found that significant muscle inflammation persisted after exon skipping in skeletal muscle. Evaluation of humoral responses showed serum-circulating antibodies directed against de novo dystrophin in a subset of mice, as assessed both by Western blotting and immunofluorescent staining; however, no dystrophin-specific antibodies were observed in the control saline-treated mdx cohorts (n = 8) or in aged (12-month-old) mdx mice with expanded 'revertant' dystrophin-expressing fibers. Reactive antibodies recognized both full-length and truncated exon-skipped dystrophin isoforms in mouse skeletal muscle. We found more antigen-specific T-cell cytokine responses (e.g. IFN-g, IL-2) in dystrophin antibody-positive mice than in dystrophin antibody-negative mice. We also found expression of major histocompatibility complex class I on some of the dystrophin-expressing fibers along with CD8+ and perforin-positive T cells in the vicinity, suggesting an activation of cell-mediated damage had occurred in the muscle. Evaluation of complement membrane attack complex (MAC) deposition on the muscle fibers further revealed lower MAC deposition on muscle fibers of dystrophin antibody-negative mice than on those of dystrophin antibody-positive mice. Our results indicate that de novo dystrophin expression after exon skipping can trigger both cell-mediated and humoral immune responses in mdx mice. Our data highlights the need to further investigate the autoimmune response and its long-term consequences after exon-skipping therapy. Copyright © 2019 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.


Assuntos
Distrofina/farmacologia , Éxons/efeitos dos fármacos , Morfolinos/farmacologia , Distrofia Muscular de Duchenne/tratamento farmacológico , Animais , Modelos Animais de Doenças , Distrofina/genética , Éxons/genética , Terapia Genética/métodos , Masculino , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos mdx , Camundongos Transgênicos , Fibras Musculares Esqueléticas/efeitos dos fármacos , Fibras Musculares Esqueléticas/metabolismo , Músculo Esquelético/efeitos dos fármacos , Músculo Esquelético/patologia , Distrofia Muscular de Duchenne/genética
9.
Skelet Muscle ; 8(1): 13, 2018 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-29625576

RESUMO

BACKGROUND: Fukutin-related protein (FKRP) mutations are the most common cause of dystroglycanopathies known to cause both limb girdle and congenital muscular dystrophy. The P448Lneo- mouse model has a knock-in mutation in the FKRP gene and develops skeletal, respiratory, and cardiac muscle disease. METHODS: We studied the natural history of the P448Lneo- mouse model over 9 months and the effects of twice weekly treadmill running. Forelimb and hindlimb grip strength (Columbus Instruments) and overall activity (Omnitech Electronics) assessed skeletal muscle function. Echocardiography was performed using VisualSonics Vevo 770 (FujiFilm VisualSonics). Plethysmography was performed using whole body system (ADInstruments). Histological evaluations included quantification of inflammation, fibrosis, central nucleation, and fiber size variation. RESULTS: P448Lneo- mice had significantly increased normalized tissue weights compared to controls at 9 months of age for the heart, gastrocnemius, soleus, tibialis anterior, quadriceps, and triceps. There were no significant differences seen in forelimb or hindlimb grip strength or activity monitoring in P448Lneo- mice with or without exercise compared to controls. Skeletal muscles demonstrated increased inflammation, fibrosis, central nucleation, and variation in fiber size compared to controls (p < 0.05) and worsened with exercise. Plethysmography showed significant differences in respiratory rates and decreased tidal and minute volumes in P448Lneo- mice (p < 0.01). There was increased fibrosis in the diaphragm compared to controls (p < 0.01). Echocardiography demonstrated decreased systolic function in 9-month-old mutant mice (p < 0.01). There was increased myocardial wall thickness and mass (p < 0.001) with increased fibrosis in 9-month-old P448Lneo- mice compared to controls (p < 0.05). mRNA expression for natriuretic peptide type A (Nppa) was significantly increased in P448Lneo- mice compared to controls at 6 months (p < 0.05) and for natriuretic peptide type B (Nppb) at 6 and 9 months of age (p < 0.05). CONCLUSIONS: FKRP-deficient P448Lneo- mice demonstrate significant deficits in cardiac and respiratory functions compared to control mice, and this is associated with increased inflammation and fibrosis. This study provides new functional outcome measures for preclinical trials of FKRP-related muscular dystrophies.


Assuntos
Coração/fisiopatologia , Músculo Esquelético/fisiopatologia , Distrofia Muscular Animal/fisiopatologia , Proteínas/fisiologia , Animais , Peso Corporal/fisiologia , Modelos Animais de Doenças , Ecocardiografia , Fibrose , Força da Mão/fisiologia , Masculino , Camundongos Mutantes , Fibras Musculares Esqueléticas/patologia , Músculo Esquelético/patologia , Distrofia Muscular Animal/genética , Distrofia Muscular Animal/patologia , Miocárdio/patologia , Miosite/genética , Miosite/patologia , Miosite/fisiopatologia , Tamanho do Órgão/fisiologia , Pentosiltransferases , Condicionamento Físico Animal , Pletismografia Total/métodos , Proteínas/genética , Músculos Respiratórios/patologia , Músculos Respiratórios/fisiopatologia , Transferases
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...