Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
BMC Cardiovasc Disord ; 19(1): 146, 2019 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-31208342

RESUMO

BACKGROUND: Little is known about the ICD performance using enhanced detection algorithms in unselected, non-trial patients. Performance of recent generation ICD equipped with SmartShock™ technology (SST) for detection and conversion of ventricular tachyarrhythmias (VTA) was investigated. METHODS: 4P was a prospective, multicenter, observational study conducted in 10 Swiss implanting centers. Patients with a Class I indication according to international guidelines were included and received an ICD with SST. ICD discrimination capability was assessed by evaluating SST performance; therapy efficacy was assessed by rate of VTA conversions by ATP and by rescue shocks. RESULTS: Overall, 196 patients were included in the analysis with a mean duration of follow-up of 27.7 months (452 patient-years of observation). Patient-specific rather than recommended programming was preferred. Device-detected episodes were frequent (5147 episodes in 146 patients, 74.5%). In 44 patients (22.4%), 1274 episodes were categorized as VTA; only 215 episodes were symptomatic. ATP was the first-line therapy and highly effective (99.9% success rate at the episode level, 100.0% at the patient level). Rescue shocks were rare (66 episodes in 28 patients); 7 shocks in 5 patients (2.6%) were inappropriate. Death and hospitalization rates were low. CONCLUSIONS: In a cohort of non-trial, unselected ICD patients, VTA episodes were frequent. The 4P results confirm the robustness of VTA detection by SST and the effectiveness of ATP treatment, hence limiting overall ICD shock burden.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Frequência Cardíaca , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Idoso , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Fatores de Risco , Suíça , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/fisiopatologia
2.
Europace ; 21(2): 275-280, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30202950

RESUMO

AIMS: Leadless pacemakers are implanted in Switzerland since June 2015. Large worldwide registries have shown high implant success, low complication rates, and good electrical parameters up to 12 months' follow-up. However, data are scarce outside the investigational setting. The purpose of this study is to assess the real-world experience regarding clinical safety and efficacy of Micra TPS (transcatheter pacing system) leadless pacemakers. METHODS AND RESULTS: Retrospective observational, multi-centre study designed to assess initial safety and efficacy of the Micra TPS in the Swiss Romande region. A total of 92 patients were included from four different centres with an implantation success rate of 97.8% (90 of 92). Thresholds were overall low at implantation (median 0.38 V/0.24 ms, ranging from 0.13 to 2.88 V/0.24 ms) and remained stable over 1-year follow-up. The perioperative serious adverse event rate was 6.5% in six patients which lead to prolonged hospitalization in five patients and death in one patient. In addition, three further major events (3.3%) occurred during an average follow-up of 1 year, requiring implantation of a standard transvenous pacemaker in two patients, and surgical explantation of the Micra TPS in one patient due to intractable ventricular tachycardia. CONCLUSION: Leadless pacemakers are a valuable adjunct for treating selected patients requiring single-chamber pacing. However, in this initial experience, major complication rates were high (9.8%). The implant procedure requires proper training and should be performed in an adequate setting.


Assuntos
Arritmias Cardíacas/terapia , Cateterismo Cardíaco , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Potenciais de Ação , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/mortalidade , Remoção de Dispositivo , Desenho de Equipamento , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Suíça , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
3.
J Cardiovasc Electrophysiol ; 25(4): 418-427, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24383960

RESUMO

INTRODUCTION: Paroxysmal atrial fibrillation (AF) may be triggered by intermittent atrial tachycardia, and ultimately lead to persistent AF. However, the mechanisms by which intermittent atrial tachycardia promotes sustained AF are not well understood. METHODS AND RESULTS: Eight sheep were chronically implanted with 2 pacemakers for the recording of broadband right atrial unipolar electrograms, and for the delivery of electrophysiological stimulation protocols and intermittent right atrial tachycardia. Right atrial kinetics of activation recovery interval (ARI) as a surrogate for action potential duration, of conduction time and velocity, and of repolarization alternans were analyzed at incremental pacing rates during the remodeling process induced by weeks of intermittent atrial tachycardia until the development of sustained AF. Intermittent atrial tachycardia decreased ARI and blunted its rate adaptation, facilitated atrial capture, and slowed conduction at high rates, and increased susceptibility to pacing-induced AF. In spite of blunted ARI rate adaptation, right atrial repolarization alternans was maintained during remodeling, and further increased in magnitude just before rapid pacing-induced AF. CONCLUSION: This study suggests that weeks of intermittent right atrial tachycardia result in a gradual electrical remodeling favorable for wavebreaks and reentry that may facilitate fibrillation.


Assuntos
Fibrilação Atrial/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia Atrial Ectópica/fisiopatologia , Animais , Remodelamento Atrial/fisiologia , Estimulação Cardíaca Artificial , Modelos Animais de Doenças , Eletrocardiografia , Cinética , Masculino , Período Refratário Eletrofisiológico , Ovinos
4.
J Cardiovasc Electrophysiol ; 23(9): 1003-12, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22554055

RESUMO

UNLABELLED: Kinetics of Atrial Repolarization Alternans. INTRODUCTION: Repolarization alternans (Re-ALT), a beat-to-beat alternation in action potential repolarization, promotes dispersion of repolarization, wavebreaks, and reentry. Recently, Re-ALT has been shown to play an important role in the transition from rapid pacing to atrial fibrillation (AF) in humans. The detailed kinetics of atrial Re-ALT, however, has not been reported so far. We developed a chronic free-behaving ovine pacing model to study the kinetics of atrial Re-ALT as a function of pacing rate. METHODS: Thirteen sheep were chronically implanted with 2 pacemakers for the recording of broadband right atrial unipolar electrograms and delivery of rapid pacing protocols. Beat-to-beat differences in the atrial T-wave apex amplitude as a measure of Re-ALT and activation time were analyzed at incremental pacing rates until the effective refractory period (ERP) defined as stable 2:1 capture. RESULTS: Atrial Re-ALT appeared intermittently but without periodicity, and increased in amplitude as a function of pacing rate until ERP. Intermittent 2:1 atrial capture was observed at pacing cycle lengths 40 ms above ERP, and increased in duration as a function of pacing rate. Episodes of rapid pacing-induced AF were rare, and were preceded by Re-ALT or complex oscillations of atrial repolarization, but without intermittent capture. CONCLUSION: We show in vivo that atrial Re-ALT developed and increased in magnitude with rate until stable 2:1 capture. In rare instances where capture failure did not occur, Re-ALT and complex oscillations of repolarization surged and preceded AF initiation. (J Cardiovasc Electrophysiol, Vol. 23, pp. 1003-1012, September 2012).


Assuntos
Fibrilação Atrial/fisiopatologia , Átrios do Coração/fisiopatologia , Potenciais de Ação , Animais , Estimulação Cardíaca Artificial , Cinética , Masculino , Modelos Animais , Período Refratário Eletrofisiológico , Ovinos
5.
Chest ; 138(2): 422-5, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20682531

RESUMO

Ablation strategies for the treatment of atrial fibrillation (AF) are associated with several potential complications. During electro-anatomic mapping of the left atrium (LA) before ablation, the ablation catheter was entrapped in the right inferior pulmonary vein (RIPV). After multiple unsuccessful gentle tractions, stronger maneuvers with rotation of the catheter slowly allowed its retrieval. Examination of the catheter showed a thin, translucent membrane covering its tip, suggesting complete stripping of a vein branch. Occlusion of the superior branch of the RIPV was confirmed by LA angiogram. During the following days, no pericardial effusion was noted, but the patient complained of light chest pain and mild hemoptysis, spontaneously resolving within 48 h. This case shows that catheter entrapment and mechanical disruption of a PV branch can be a rare potential complication of AF ablation. In this case, the outcome was spontaneously favorable and symptoms only included transient mild hemoptysis.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Veias Pulmonares , Cateterismo/efeitos adversos , Feminino , Humanos , Pessoa de Meia-Idade
6.
Rev Med Suisse ; 6(251): 1140, 1142-5, 2010 Jun 02.
Artigo em Francês | MEDLINE | ID: mdl-20572358

RESUMO

Idiopathic premature ventricular complexes originating from the ventricular outflow tract: evaluation, prognosis and management The prognosis of ventricular premature complexes (VPC) in the absence of heart disease is considered benign. VPC usually originate from the right or, less commonly, left ventricular outflow tract. QRS complexes therefore usually assume a left bundle branch block and inferior axis morphology. These VPC, particularly if very frequent (> 20,000 per day), may adversely affect left ventricular function and their suppression can restore normal function. Moreover, there is a clinical overlap with arrhythmogenic right ventricular dysplasia and this diagnosis should be considered when facing a left bundle branch block shaped VPC. However, the prognosis of outflow tract VPC is good for appropriately selected patients with normal left ventricular function, absence of syncope or ventricular tachycardia, and no evidence of cardiac disease.


Assuntos
Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/terapia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia , Humanos , Prognóstico , Síncope/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/terapia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/mortalidade , Complexos Ventriculares Prematuros/cirurgia
7.
Europace ; 11(12): 1639-46, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19864312

RESUMO

AIMS: Estimates of the left ventricular ejection fraction (LVEF) in patients with life-threatening ventricular arrhythmias related to coronary artery disease (CAD) have rarely been reported despite it has become the basis for determining patient's eligibility for prophylactic defibrillator. We aimed to determine the extent and distribution of reduced LVEF in patients with sustained ventricular tachycardia or ventricular fibrillation. METHODS AND RESULTS: 252 patients admitted for ventricular arrhythmia related to CAD were included: 149 had acute myocardial infarction (MI) (Group I, 59%), 54 had significant chronic obstructive CAD suggestive of an ischaemic arrhythmic trigger (Group II, 21%) and 49 patients had an old MI without residual ischaemia (Group III, 19%). 34% of the patients with scar-related arrhythmias had an LVEF > or =40%. Based on pre-event LVEF evaluation, it can be estimated that less than one quarter of the whole study population had a known chronic MI with severely reduced LVEF. In Group III, the proportion of inferior MI was significantly higher than anterior MI (81 vs. 19%; absolute difference, -62; 95% confidence interval, -45 to -79; P < or = 0.0001), though median LVEF was higher in inferior MI (0.37 +/- 10 vs. 0.29 +/- 10; P = 0.0499). CONCLUSION: Patients included in defibrillator trials represent only a minority of the patients at risk of sudden cardiac death. By applying the current risk stratification strategy based on LVEF, more than one third of the patients with old MI would not have qualified for a prophylactic defibrillator. Our study also suggests that inferior scars may be more prone to ventricular arrhythmia compared to anterior scars.


Assuntos
Doença da Artéria Coronariana/epidemiologia , Infarto do Miocárdio/epidemiologia , Volume Sistólico , Disfunção Ventricular Esquerda/epidemiologia , Fibrilação Ventricular/epidemiologia , Idoso , Comorbidade , Doença da Artéria Coronariana/diagnóstico , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Medição de Risco , Fatores de Risco , Suíça/epidemiologia , Disfunção Ventricular Esquerda/diagnóstico , Fibrilação Ventricular/diagnóstico
8.
Pacing Clin Electrophysiol ; 32 Suppl 1: S202-6, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19250095

RESUMO

BACKGROUND: Up to 60% of syncopal episodes remain unexplained. We report the results of a standardized, stepwise evaluation of patients referred to an ambulatory clinic for unexplained syncope. METHODS AND RESULTS: We studied 939 consecutive patients referred for unexplained syncope, who underwent a standardized evaluation, including history, physical examination, electrocardiogram, head-up tilt testing (HUTT), carotid sinus massage (CSM) and hyperventilation testing (HYV). Echocardiogram and stress test were performed when underlying heart disease was initially suspected. Electrophysiological study (EPS) and implantable loop recorder (ILR) were used only in patients with underlying structural heart disease or major unexplained syncope. We identified a cause of syncope in 66% of patients, including 27% vasovagal, 14% psychogenic, 6% arrhythmias, and 6% hypotension. Noninvasive testing identified 92% and invasive testing an additional 8% of the causes. HUTT yielded 38%, CSM 28%, HYV 49%, EPS 22%, and ILR 56% of diagnoses. On average, patients with arrhythmic causes were older, had a lower functional capacity, longer P-wave duration, and presented with fewer prodromes than patients with vasovagal or psychogenic syncope. CONCLUSIONS: A standardized stepwise evaluation emphasizing noninvasive tests yielded 2/3 of causes in patients referred to an ambulatory clinic for unexplained syncope. Neurally mediated and psychogenic mechanisms were behind >50% of episodes, while cardiac arrhythmias were uncommon. Sudden syncope, particularly in older patients with functional limitations or a prolonged P-wave, suggests an arrhythmic cause.


Assuntos
Monitorização Ambulatorial/estatística & dados numéricos , Síncope/diagnóstico , Síncope/epidemiologia , Causalidade , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suíça/epidemiologia
9.
Rev Med Suisse ; 4(168): 1836-40, 2008 Aug 27.
Artigo em Francês | MEDLINE | ID: mdl-18814770

RESUMO

Placement of automated external defibrillators (AED) in public facilities and training of the lay persons in basic life support-defibrillation (BLS-D) was recommended by the American Heart Association for the treatment of out-of-hospital cardiac arrest (OHCA). Immediate use of AED result in increase of survival to hospital discharge. Many observation and much less randomized trials describe clinical efficacy of this approach. However, "negative" trials have also been published and some recent data suggest that public access defibrillation (PAD) will have a minimal impact on population survival. In this article various PAD strategies were briefly reviewed. In our opinion installation of AED in public places should be based on the long-term study of local OHCA demography and preceded by widespread BLS training of lay population.


Assuntos
Participação da Comunidade , Desfibriladores , Parada Cardíaca/terapia , Logradouros Públicos , Política de Saúde , Humanos
12.
Europace ; 9 Suppl 6: vi83-8, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17959698

RESUMO

AIMS: Experimental models have reported conflicting results regarding the role of dispersion of repolarization in promoting atrial fibrillation (AF). Repolarization alternans, a beat-to-beat alternation in action potential duration, enhances dispersion of repolarization when propagation velocity is involved. METHODS AND RESULTS: In this work, original electrophysiological parameters were analysed to study AF susceptibility in a chronic sheep model of pacing-induced AF. Two pacemakers were implanted, each with a single right atrial lead. Right atrial depolarization and repolarization waves were documented at 2-week intervals. A significant and gradual decrease in the propagation velocity at all pacing rates and in the right atrial effective refractory period (ERP) was observed during the weeks of burst pacing before sustained AF developed when compared with baseline conditions. Right atrial repolarization alternans was observed, but because of the development of 2/1 atrioventricular block with far-field ventricular interference, its threshold could not be precisely measured. Non-sustained AF was not observed at baseline, but appeared during the electrical remodelling in association with a decrease in both ERP and propagation velocity. CONCLUSION: We report here on the feasibility of measuring ERP, atrial repolarization alternans, and propagation velocity kinetics and their potential in predicting susceptibility to AF in a free-behaving model of pacing-induced AF using the standard pacemaker technology.


Assuntos
Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial , Modelos Animais de Doenças , Potenciais de Ação/fisiologia , Animais , Sistema de Condução Cardíaco/fisiopatologia , Cinética , Condução Nervosa/fisiologia , Marca-Passo Artificial , Ovinos
15.
Rev Med Suisse ; 3(138): 2914-8, 2007 Dec 19.
Artigo em Francês | MEDLINE | ID: mdl-18277768

RESUMO

The implantable loop recorder developed by Medtronic (Reveal plus) is a small device inserted subcutaneously under local anesthesia in patients with syncope of unexplained origin. This device enables a single lead-ECG recording and has autonomy of two years. Memories are activated during episodes of bradycardia or tachycardia, either automatically or manually. Several studies have shown a high diagnostic rate reaching 50% and demonstrated its cost-effectiveness. There is also a significant reduction in syncopal episodes and a higher quality of life score in patients with syncope of unexplained origin.


Assuntos
Próteses e Implantes , Síncope/diagnóstico , Eletrocardiografia Ambulatorial/instrumentação , Humanos , Síncope/etiologia
17.
J Am Coll Cardiol ; 48(5): e247-346, 2006 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-16949478
18.
Eur Heart J ; 27(17): 2099-140, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16923744
19.
Europace ; 8(9): 746-837, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16935866
20.
Circulation ; 114(10): e385-484, 2006 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-16935995
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...