Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
BMC Microbiol ; 19(1): 81, 2019 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-31023224

RESUMO

BACKGROUND: Concern exists that frequent use of topically-applied fusidic acid (FA) and chlorhexidine (CHX) for canine pyoderma is driving clinically relevant resistance, despite rare description of FA and CHX genetic resistance determinants in canine-derived staphylococci. This study aimed to determine minimum inhibitory concentrations (MICs) and investigate presence of putative resistance determinants for FA and CHX in canine-derived methicillin-resistant (MR) and -susceptible (MS) staphylococci. Plasmid-mediated resistance genes (fusB, fusC, fusD, qacA/B, smr; PCR) and MICs (agar dilution) of FA and CHX were investigated in 578 staphylococci (50 MR S. aureus [SA], 50 MSSA, 259 MR S. pseudintermedius [SP], 219 MSSP) from Finland, U.S.A., North (NUK) and South-East U.K. (SEUK) and Germany. In all isolates with FA MIC ≥64 mg/L (n = 27) fusA and fusE were amplified and sequenced. RESULTS: FA resistance determinants (fusA mutations n = 24, fusB n = 2, fusC n = 36) were found in isolates from all countries bar U.S.A. and correlated with higher MICs (≥1 mg/L), although 4 SP isolates had MICs of 0.06 mg/L despite carrying fusC. CHX MICs did not correlate with qacA/B (n = 2) and smr (n = 5), which were found in SEUK SA, and SP from NUK and U.S.A. CONCLUSIONS: Increased FA MICs were frequently associated with fusA mutations and fusC, and this is the first account of fusB in SP. Despite novel description of qacA/B in SP, gene presence did not correlate with CHX MIC. Selection pressure from clinical use might increase prevalence of these genetic determinants, but clinical significance remains uncertain in relation to high skin concentrations achieved by topical therapy.


Assuntos
Clorexidina/farmacologia , Farmacorresistência Bacteriana Múltipla/genética , Ácido Fusídico/farmacologia , Staphylococcus/efeitos dos fármacos , Staphylococcus/genética , Animais , Antibacterianos/farmacologia , Proteínas de Bactérias/genética , Desinfetantes/farmacologia , Cães/microbiologia , Finlândia , Alemanha , Resistência a Meticilina/genética , Testes de Sensibilidade Microbiana , Fator G para Elongação de Peptídeos/genética , Pioderma/microbiologia , Pioderma/veterinária , Fatores R , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/genética , Estados Unidos
2.
Neurology ; 77(3): 250-6, 2011 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-21734183

RESUMO

OBJECTIVE: The aim of the study was to assess different outcome measures in a cohort of ambulant boys with Duchenne muscular dystrophy (DMD) over 12 months in order to establish the spectrum of possible changes in relation to age and steroid treatment. METHODS: The study is a longitudinal multicentric cohort study. A total of 106 ambulant patients with DMD were assessed using the 6-minute walk test (6MWT) and North Star Ambulatory Assessment (NSAA) at baseline and 12 months. Clinical data including age and steroid treatment were collected. RESULTS: During the 12 months of the study, we observed a mean decline of 25.8 meters in the 6MWT with a SD of 74.3 meters. On NSAA, the mean decline was 2.2 points with a SD of 3.7. Not all the boys with DMD in our cohort showed a decline over the 12 months, with young boys showing some improvement in their 6MWT and NSAA scores up to the age of 7. NSAA and the 6MWT had the highest correlation (r = 0.52, p < 0.001). CONCLUSIONS: This study provides longitudinal data of NSAA and 6MWT over a 12-month period. These data can be useful when designing a clinical trial.


Assuntos
Distrofia Muscular de Duchenne/fisiopatologia , Adolescente , Anti-Inflamatórios/uso terapêutico , Criança , Pré-Escolar , Estudos de Coortes , Estudos Transversais , Progressão da Doença , Feminino , Humanos , Masculino , Distrofia Muscular de Duchenne/tratamento farmacológico , Prednisolona/uso terapêutico , Pregnenodionas/uso terapêutico , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Estatística como Assunto , Caminhada/fisiologia
3.
Neuromuscul Disord ; 19(7): 458-61, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19553120

RESUMO

The aim of this study was to investigate the suitability of the North Star Ambulatory Assessment as a possible outcome measure in multicentric clinical trials. More specifically we wished to investigate the level of training needed for achieving a good interobserver reliability in a multicentric setting. The scale was specifically designed for ambulant children with Duchenne Muscular Dystrophy and includes 17 items that are relevant for this cohort. Thirteen Italian centers participated in the study. In the first phase of the study we provided two training videos and an example of the scale performed on a child. After the first session of training, all the 13 examiners were asked to send a video with an assessment performed in their centre and to score all the videos collected. There were no difficulties in performing the items and in obtaining adequate videos with a hand held camera but the results showed a poor interobserver reliability (<.5). After a second training session with review and discussion of the videos previously scored, the same examiners were asked to score three new videos. The results of this session had an excellent interobserver reliability (.995). The level of agreement was maintained even when the same videos were rescored after a month, showing a significant intra-observer reliability (.95). Our results suggest that the NSAA is a test that can be easily performed, completed in 10 min and can be used in a multicentric setting, providing that adequate training is administered.


Assuntos
Avaliação da Deficiência , Limitação da Mobilidade , Distrofia Muscular de Duchenne/diagnóstico , Distrofia Muscular de Duchenne/reabilitação , Avaliação de Resultados em Cuidados de Saúde/métodos , Caminhada/fisiologia , Criança , Pré-Escolar , Estudos de Coortes , Interpretação Estatística de Dados , Terapia por Exercício/métodos , Tolerância ao Exercício/fisiologia , Humanos , Itália , Perna (Membro)/fisiopatologia , Masculino , Músculo Esquelético/fisiopatologia , Variações Dependentes do Observador , Modalidades de Fisioterapia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Gravação em Vídeo
4.
Strabismus ; 9(2): 71-7, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11458295

RESUMO

PURPOSE: The purpose of this study was to investigate the evolution of refraction and visual function in patients with myopic anisometropia. DESIGN: A retrospective study on a selected population. METHODS: Forty-six anisomyopic patients underwent a complete ophthalmologic examination (cycloplegic refraction, visual acuity, ocular movement and fundus examination). RESULTS: The results show two different patterns of changes in refraction between the two eyes; in the same patient, the less myopic eye tends to get more myopic, while the more ametropic eye shows a more stable refraction. Furthermore, a recovery of binocular vision and amblyopia can be obtained by occlusion and full-time refractive correction. CONCLUSIONS: The evolution of refraction seems to be different in eyes with anisometropia and it is still to be understood whether it is fixation or reduced fixation that leads to a myopic shift.


Assuntos
Anisometropia/fisiopatologia , Miopia/fisiopatologia , Refração Ocular/fisiologia , Criança , Pré-Escolar , Movimentos Oculares , Humanos , Lactente , Midriáticos/administração & dosagem , Pupila/efeitos dos fármacos , Estudos Retrospectivos , Visão Binocular/fisiologia , Acuidade Visual/fisiologia
5.
G Ital Med Lav Ergon ; 23(1): 21-4, 2001.
Artigo em Italiano | MEDLINE | ID: mdl-11386182

RESUMO

A correct evaluation of the colour vision is important to make decisions concerning the recruitment in numerous occupations that require colour discrimination. In order to identify valid pre-employment colour vision testing methods, tests actually used and in particular the Ishihara test are considered. After a careful examination we conclude that candidates who pass the Ishihara test have sufficient colour perception to meet ordinary needs and further trade test are not necessary. Nevertheless we do not consider sufficient to rely on the Ishihara test alone to reject a candidate. The diagnostic algorihm proposed is recommended in pre-employment medical examinations for distinguishing people with normal colour vision, slight or sever colour deficiency.


Assuntos
Defeitos da Visão Cromática/diagnóstico , Avaliação da Capacidade de Trabalho , Algoritmos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...