Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Acta Radiol ; 43(3): 269-74, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12100323

RESUMO

PURPOSE: To evaluate measurements of thyroid volume by two different US methods and CT in a blinded design. MATERIAL AND METHODS: Four observers evaluated 27 patients. Observer 1 used US and calculated thyroid volume based on recordings of cross-sections through the gland. Observer 2 used US and calculated the volume of each lobe as a rotation ellipsoid. Observers A and B used CT images and calculated thyroid volume based on recordings of cross-sections through the gland. All measurements were made twice. RESULTS: The median thyroid volume was 81 ml (range 7-470 ml) evaluated by CT. All three methods had fair reproducibility. When correlating the two different methods using US, an r of 0.837 was found. When correlating data from patients without intrathoracic goitre evaluated by US (Observer 1) and CT, r = 0.945. The method based on a rotation ellipsoid systematically produced smaller thyroid volumes than those of the cross-sectional method. Evaluation by US systematically produced smaller thyroid volumes than CT. CONCLUSION: Calculation of thyroid volume based on US recordings of cross-sectional areas is a reproducible method in patients without substernal goitre extension. The US method calculating thyroid volume as a rotation ellipsoid is less reproducible, especially in large goitres. Measurement of thyroid volume using CT should be preferred in goitres with substernal extension.


Assuntos
Glândula Tireoide/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Bócio/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Reprodutibilidade dos Testes , Rotação , Ultrassonografia
2.
Acad Radiol ; 5(6): 409-14, 1998 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9615150

RESUMO

RATIONALE AND OBJECTIVES: The authors attempted to determine whether the use of nonionic contrast media causes uptake of iodine by the thyroid to be blocked and whether use of these agents could cause iodine-induced hyperthyroidism. MATERIALS AND METHODS: Twenty-eight persons, including 22 with thyroid disease, were included in the study. Subjects underwent computed tomography (CT) of the thyroid after injection of 100 mL of iohexol. Thyroid function variables were measured before CT scanning and 1 week and 1 month later. In 16 subjects, uptake of iodine-131 by the thyroid was measured before and 1 week after CT. RESULTS: I-131 uptake was reduced to 53.4% at 1 week after the injection of iohexol but became normal within a few weeks (followed up in one patient). An accelerated escape of I-131 from the thyroid was seen during the 1st days after the iohexol administration. Eight of 22 patients with an underlying thyroid disease had a temporary change in thyroid function. In four patients, the serum thyrotropin level was increased 1 week after the iohexol administration. In four other patients, temporary hyperthyroidism developed during the following months. CONCLUSION: Iohexol can be used in patients with an underlying thyroid disease, but close monitoring in the following months is necessary.


Assuntos
Meios de Contraste/administração & dosagem , Radioisótopos do Iodo/farmacocinética , Iohexol/administração & dosagem , Doenças da Glândula Tireoide/metabolismo , Glândula Tireoide/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Hipertireoidismo/sangue , Hipertireoidismo/induzido quimicamente , Hipertireoidismo/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Cintilografia , Fatores de Risco , Doenças da Glândula Tireoide/diagnóstico por imagem , Testes de Função Tireóidea , Glândula Tireoide/diagnóstico por imagem , Tireotropina/sangue , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA