Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
3.
Clin Res Cardiol ; 107(8): 670-678, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29582136

RESUMO

OBJECTIVE: Unexplained cardiac arrest (UCA) is often the first manifestation of an inherited arrhythmogenic disease. Genetic testing in UCA is challenging due to the complexities of variant interpretation in the absence of supporting cardiac phenotype. We aimed to investigate if a KCNQ1 variant [p.(Pro64_Pro70del)], previously reported as pathogenic, contributes to the long-QT syndrome phenotype, co-segregates with disease or affects KCNQ1 function in vitro. METHODS: DNA was extracted from peripheral blood of a 22-year-old male after resuscitation from UCA. Targeted exome sequencing was performed using the TruSight-One Sequencing Panel (Illumina). Variants in 190 clinically relevant cardiac genes with minor allele frequency < 1% were analyzed according to the guidelines of the American College of Medical Genetics. Functional characterization was performed using site-directed mutagenesis, expression in Xenopus laevis oocytes using the two-electrode voltage-clamp technique. RESULTS: The 12-lead ECG, transthoracic echocardiography and coronary angiography after resuscitation showed no specific abnormalities. Two variants were identified: c.190_210del in-frame deletion in KCNQ1 (p.Pro64_Pro70del), reported previously as pathogenic and c.2431C > A in PKP2 (p.Arg811Ser), classified as likely benign. Two asymptomatic family members with no evident phenotype hosted the KCNQ1 variant. Functional studies showed that the wild-type and mutant channels have no significant differences in current levels, conductance-voltage relationships, as well as activation and deactivation kinetics, in the absence and presence of the auxiliary subunit KCNE1. CONCLUSIONS: Based on our data and previous reports, available evidence is insufficient to consider the variant KCNQ1:c.190_210del as pathogenic. Our findings call for cautious interpretation of genetic tests in UCA in the absence of a clinical phenotype.


Assuntos
DNA/genética , Testes Genéticos/métodos , Parada Cardíaca/etiologia , Canal de Potássio KCNQ1/genética , Síndrome do QT Longo/complicações , Mutação , Análise Mutacional de DNA , Eletrocardiografia , Frequência do Gene , Parada Cardíaca/sangue , Parada Cardíaca/genética , Humanos , Canal de Potássio KCNQ1/metabolismo , Síndrome do QT Longo/sangue , Síndrome do QT Longo/genética , Masculino , Linhagem , Fenótipo , Adulto Jovem
5.
IEEE Trans Biomed Eng ; 65(2): 424-430, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29346109

RESUMO

OBJECTIVE: cardiac pacemakers require regular medical follow-ups to ensure proper functioning. However, device replacements due to battery depletion are common and account for ∼25% of all implantation procedures. Furthermore, conventional pacemakers require pacemaker leads which are prone to fractures, dislocations or isolation defects. The ensuing surgical interventions increase risks for the patients and costs that need to be avoided. METHODS: in this study, we present a method to harvest energy from endocardial heart motions. We developed a novel generator, which converts the heart's mechanical into electrical energy by electromagnetic induction. A mathematical model has been introduced to identify design parameters strongly related to the energy conversion efficiency of heart motions and fit the geometrical constraints for a miniaturized transcatheter deployable device. The implemented final design was tested on the bench and in vivo. RESULTS: the mathematical model proved an accurate method to estimate the harvested energy. For three previously recorded heart motions, the model predicted a mean output power of 14.5, 41.9, and 16.9 µW. During an animal experiment, the implanted device harvested a mean output power of 0.78 and 1.7 µW at a heart rate of 84 and 160 bpm, respectively. CONCLUSION: harvesting kinetic energy from endocardial motions seems feasible. Implanted at an energetically favorable location, such systems might become a welcome alternative to extend the lifetime of cardiac implantable electronic device. SIGNIFICANCE: the presented endocardial energy harvesting concept has the potential to turn pacemakers into battery- and leadless systems and thereby eliminate two major drawbacks of contemporary systems.


Assuntos
Engenharia Biomédica/métodos , Endocárdio , Marca-Passo Artificial , Próteses e Implantes , Animais , Simulação por Computador , Fontes de Energia Elétrica , Fenômenos Eletromagnéticos , Endocárdio/diagnóstico por imagem , Endocárdio/fisiologia , Endocárdio/cirurgia , Frequência Cardíaca , Desenho de Prótese , Processamento de Sinais Assistido por Computador , Suínos
6.
IEEE Trans Biomed Circuits Syst ; 11(1): 78-86, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27662683

RESUMO

Energy harvesting devices are widely discussed as an alternative power source for todays active implantable medical devices. Repeated battery replacement procedures can be avoided by extending the implants life span, which is the goal of energy harvesting concepts. This reduces the risk of complications for the patient and may even reduce device size. The continuous and powerful contractions of a human heart ideally qualify as a battery substitute. In particular, devices in close proximity to the heart such as pacemakers, defibrillators or bio signal (ECG) recorders would benefit from this alternative energy source. The clockwork of an automatic wristwatch was used to transform the hearts kinetic energy into electrical energy. In order to qualify as a continuous energy supply for the consuming device, the mechanism needs to demonstrate its harvesting capability under various conditions. Several in-vivo recorded heart motions were used as input of a mathematical model to optimize the clockworks original conversion efficiency with respect to myocardial contractions. The resulting design was implemented and tested during in-vitro and in-vivo experiments, which demonstrated the superior sensitivity of the new design for all tested heart motions.


Assuntos
Fontes de Energia Bioelétrica , Coração/fisiologia , Marca-Passo Artificial , Próteses e Implantes , Desenho de Equipamento , Humanos , Modelos Teóricos
8.
J Electrocardiol ; 49(4): 496-503, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27016257

RESUMO

PURPOSE: Paroxysmal atrial fibrillation (PAF) often remains undiagnosed. Long-term surface ECG is used for screening, but has limitations. Esophageal ECG (eECG) allows recording high quality atrial signals, which were used to identify markers for PAF. METHODS: In 50 patients (25 patients with PAF; 25 controls) an eECG and surface ECG was recorded simultaneously. Partially A-V blocked atrial runs (PBARs) were quantified, atrial signal duration in eECG was measured. RESULTS: eECG revealed 1.8‰ of atrial premature beats in patients with known PAF to be PBARs with a median duration of 853ms (interquartile range (IQR) 813-1836ms) and a median atrial cycle length of 366ms (IQR 282-432ms). Even during a short recording duration of 2.1h (IQR 1.2-17.2h), PBARs occurred in 20% of PAF patients but not in controls (p=0.05). Left atrial signal duration was predictive for PAF (72% sensitivity, 80% specificity). CONCLUSIONS: eECG reveals partially blocked atrial runs and prolonged left atrial signal duration - two novel surrogate markers for PAF.


Assuntos
Doenças Assintomáticas , Fibrilação Atrial/diagnóstico , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Idoso , Algoritmos , Biomarcadores , Esôfago , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Heart Rhythm ; 13(5): 1075-1082, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26738946

RESUMO

BACKGROUND: We observed a case of conductor externalization in a Biotronik Linox lead. OBJECTIVE: The purpose of this study was to investigate lead performance of the Linox lead and the identical Sorin Vigila lead and prevalence of conductor externalization. METHODS: We compared lead performance of all Linox and Vigila leads implanted at our center (BL group; n = 93) with that of all Boston Scientific Endotak Reliance leads (ER group; n = 190) and Medtronic Sprint Quattro leads (SQ group; n = 202) implanted during the same period. We screened all patients in the BL group for conductor externalization. RESULTS: We identified 8 cases of lead failures in the BL group (index case of conductor externalization, 6 cases of nonphysiological high-rate sensing, and 1 case of high-voltage conductor fracture). Prospective fluoroscopic screening of 98% of all active BL group cases revealed 1 additional case of conductor externalization. The median follow-up was 41, 27, and 29 months for the BL group, ER group, and SQ group, respectively; lead survival was 94.9%, 99.2%, and 100% at 3 years and 88%, 97.5%, and 100% at 5 years (P = .038 for BL group vs ER group and P = .007 for BL group vs SQ group using the log-rank test). Younger age at implant was an independent predictor of lead failure in the BL group (adjusted hazard ratio 0.85; 95% confidence interval 0.77-0.94; P = .001). CONCLUSION: At our center, survival of the Linox lead is 88% at 5 years and significantly worse than that of other leads. Conductor externalization is present in a minority of failed Linox leads. Younger age at implant is an independent predictor of Linox lead failure.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Falha de Prótese , Taquicardia Ventricular/terapia , Adulto , Fatores Etários , Idoso , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/classificação , Desenho de Equipamento , Análise de Falha de Equipamento/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Suíça
10.
Heart Rhythm ; 12(6): 1317-23, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25744612

RESUMO

BACKGROUND: Contemporary pacemakers (PMs) are powered by primary batteries with a limited energy-storing capacity. PM replacements because of battery depletion are common and unpleasant and bear the risk of complications. Batteryless PMs that harvest energy inside the body may overcome these limitations. OBJECTIVE: The goal of this study was to develop a batteryless PM powered by a solar module that converts transcutaneous light into electrical energy. METHODS: Ex vivo measurements were performed with solar modules placed under pig skin flaps exposed to different irradiation scenarios (direct sunlight, shade outdoors, and indoors). Subsequently, 2 sunlight-powered PMs featuring a 4.6-cm(2) solar module were implanted in vivo in a pig. One prototype, equipped with an energy buffer, was run in darkness for several weeks to simulate a worst-case scenario. RESULTS: Ex vivo, median output power of the solar module was 1963 µW/cm(2) (interquartile range [IQR] 1940-2107 µW/cm(2)) under direct sunlight exposure outdoors, 206 µW/cm(2) (IQR 194-233 µW/cm(2)) in shade outdoors, and 4 µW/cm(2) (IQR 3.6-4.3 µW/cm(2)) indoors (current PMs use approximately 10-20 µW). Median skin flap thickness was 4.8 mm. In vivo, prolonged SOO pacing was performed even with short irradiation periods. Our PM was able to pace continuously at a rate of 125 bpm (3.7 V at 0.6 ms) for 1½ months in darkness. CONCLUSION: Tomorrow's PMs might be batteryless and powered by sunlight. Because of the good skin penetrance of infrared light, a significant amount of energy can be harvested by a subcutaneous solar module even indoors. The use of an energy buffer allows periods of darkness to be overcome.


Assuntos
Marca-Passo Artificial , Energia Solar , Animais , Desenho de Equipamento , Luz , Implantação de Prótese/métodos , Luz Solar , Suínos
11.
PLoS One ; 10(3): e0119184, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25734640

RESUMO

Root turnover is an important carbon flux component in grassland ecosystems because it replenishes substantial parts of carbon lost from soil via heterotrophic respiration and leaching. Among the various methods to estimate root turnover, the root's radiocarbon signature has rarely been applied to grassland soils previously, although the value of this approach is known from studies in forest soils. In this paper, we utilize the root's radiocarbon signatures, at 25 plots, in mountain grasslands of the montane to alpine zone of Europe. We place the results in context of a global data base on root turnover and discuss driving factors. Root turnover rates were similar to those of a subsample of the global data, comprising a similar temperature range, but measured with different approaches, indicating that the radiocarbon method gives reliable, plausible and comparable results. Root turnover rates (0.06-1.0 y(-1)) scaled significantly and exponentially with mean annual temperatures. Root turnover rates indicated no trend with soil depth. The temperature sensitivity was significantly higher in mountain grassland, compared to the global data set, suggesting additional factors influencing root turnover. Information on management intensity from the 25 plots reveals that root turnover may be accelerated under intensive and moderate management compared to low intensity or semi-natural conditions. Because management intensity, in the studied ecosystems, co-varied with temperature, estimates on root turnover, based on mean annual temperature alone, may be biased. A greater recognition of management as a driver for root dynamics is warranted when effects of climatic change on belowground carbon dynamics are studied in mountain grasslands.


Assuntos
Ciclo do Carbono , Carbono/química , Modelos Estatísticos , Raízes de Plantas/metabolismo , Poaceae/metabolismo , Solo/química , Agricultura , Altitude , Radioisótopos de Carbono , Mudança Climática , Europa (Continente) , Pradaria , Humanos , Raízes de Plantas/química , Poaceae/química , Temperatura
12.
Europace ; 16(10): 1534-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24916431

RESUMO

AIMS: Today's cardiac pacemakers are powered by batteries with limited energy capacity. As the battery's lifetime ends, the pacemaker needs to be replaced. This surgical re-intervention is costly and bears the risk of complications. Thus, a pacemaker without primary batteries is desirable. The goal of this study was to test whether transcutaneous solar light could power a pacemaker. METHODS AND RESULTS: We used a three-step approach to investigate the feasibility of sunlight-powered cardiac pacing. First, the harvestable power was estimated. Theoretically, a subcutaneously implanted 1 cm(2) solar module may harvest ∼2500 µW from sunlight (3 mm implantation depth). Secondly, ex vivo measurements were performed with solar cells placed under pig skin flaps exposed to a solar simulator and real sunlight. Ex vivo measurements under real sunlight resulted in a median output power of 4941 µW/cm(2) [interquartile range (IQR) 3767-5598 µW/cm(2), median skin flap thickness 3.0 mm (IQR 2.7-3.3 mm)]. The output power strongly depended on implantation depth (ρSpearman = -0.86, P < 0.001). Finally, a batteryless single-chamber pacemaker powered by a 3.24 cm(2) solar module was implanted in vivo in a pig to measure output power and to pace. In vivo measurements showed a median output power of >3500 µW/cm(2) (skin flap thickness 2.8-3.84 mm). Successful batteryless VVI pacing using a subcutaneously implanted solar module was performed. CONCLUSION: Based on our results, we estimate that a few minutes of direct sunlight (irradiating an implanted solar module) allow powering a pacemaker for 24 h using a suitable energy storage. Thus, powering a pacemaker by sunlight is feasible and may be an alternative energy supply for tomorrow's pacemakers.


Assuntos
Fontes de Energia Elétrica , Marca-Passo Artificial , Luz Solar , Animais , Desenho de Equipamento , Estudos de Viabilidade , Teste de Materiais , Suínos
13.
Heart Rhythm ; 11(6): 933-8, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24632179

RESUMO

BACKGROUND: Atrial fibrillation (AF) is common and may have severe consequences. Continuous long-term electrocardiogram (ECG) is widely used for AF screening. Recently, commercial ECG analysis software was launched, which automatically detects AF in long-term ECGs. It has been claimed that such tools offer reliable AF screening and save time for ECG analysis. However, this has not been investigated in a real-life patient cohort. OBJECTIVE: To investigate the performance of automatic software-based screening for AF in long-term ECGs. METHODS: Two independent physicians manually screened 22,601 hours of continuous long-term ECGs from 150 patients for AF. Presence, number, and duration of AF episodes were registered. Subsequently, the recordings were screened for AF by an established ECG analysis software (Pathfinder SL), and its performance was validated against the thorough manual analysis (gold standard). RESULTS: Sensitivity and specificity for AF detection was 98.5% (95% confidence interval 91.72%-99.96%) and 80.21% (95% confidence interval 70.83%-87.64%), respectively. Software-based AF detection was inferior to manual analysis by physicians (P < .0001). Median AF duration was underestimated (19.4 hours vs 22.1 hours; P < .001) and median number of AF episodes was overestimated (32 episodes vs 2 episodes; P < .001) by the software. In comparison to extensive quantitative manual ECG analysis, software-based analysis saved time (2 minutes vs 19 minutes; P < .001). CONCLUSION: Owing to its high sensitivity and ability to save time, software-based ECG analysis may be used as a screening tool for AF. An additional manual confirmatory analysis may be required to reduce the number of false-positive findings.


Assuntos
Fibrilação Atrial/diagnóstico , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Sensibilidade e Especificidade , Software
14.
J Electrocardiol ; 46(2): 158-65, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23305907

RESUMO

BACKGROUND: Diagnosing supraventricular arrhythmias by conventional long-term ECG can be cumbersome because of poor p-waves. Esophageal long-term electrocardiography (eECG) has an excellent sensitivity for atrial signals and may overcome this limitation. However, the optimal lead insertion depth (OLID) is not known. METHODS: We registered eECGs at different lead insertion depths in 27 patients and analyzed 199,716 atrial complexes with respect to signal amplitude and slope. Correlation and regression analyses were used to find a criterion for OLID. RESULTS: Atrial signal amplitudes and slopes significantly depend on lead insertion depth. OLID correlates with body height (rSpearman=0.71) and can be estimated by OLID [cm]=0.25*body height[cm]-7cm. At this insertion depth, we recorded the largest esophageal atrial signal amplitudes (1.27±0.86mV), which were much larger compared to conventional surface lead II (0.19±0.10mV, p<0.0001). CONCLUSION: The OLID depends on body height and can be calculated by a simple regression formula.


Assuntos
Fibrilação Atrial/diagnóstico , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Eletrodos Implantados , Esôfago/cirurgia , Adulto , Feminino , Humanos , Masculino , Implantação de Prótese/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Pacing Clin Electrophysiol ; 32(5): 622-6, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19422583

RESUMO

BACKGROUND: Atrial fibrillation (AF) ablation is less frequently performed in women than in men. Although the prevalence of AF is slightly higher in men, this does not fully account for the lower number of AF ablations performed in women. This study sought to examine the effect of gender on referral for AF and subsequent AF management. METHODS: Consecutive patients referred to our tertiary arrhythmia outpatient clinic for AF management were retrospectively analyzed. RESULTS: Of 264 patients referred, only 27% were women. Women were older than men (63 +/- 9 vs 58 +/- 11 years, P = 0.002), more often had paroxysmal AF (78% vs 63% in men, P = 0.022), and women more frequently complained about palpitations (71% vs 49%, P = 0.002). In addition, they had more often experienced amiodarone side effects than men (56% vs 36%, P = 0.046). In this referred population, there was no difference in the proportion of women and men undergoing AF ablation immediately following the initial evaluation (21% vs 25%, P = ns), at any time during the follow-up (38% vs 44%, P = ns), and there was no difference in the proportion of patients undergoing atrioventricular node ablation in both sexes (6% of women vs 3% of men, P = ns). CONCLUSIONS: There is an important difference in the proportion of men and women referred for management of AF in a specialized outpatient arrhythmia clinic, with women being referred three times less often than men. However, there is no gender-related difference in the subsequent treatment decisions. These findings emphasize the importance of focusing on management of symptomatic AF in women.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/prevenção & controle , Ablação por Cateter/estatística & dados numéricos , Encaminhamento e Consulta/estatística & dados numéricos , Feminino , Humanos , Incidência , Indústrias/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Medição de Risco/métodos , Fatores de Risco , Distribuição por Sexo , Suíça/epidemiologia
16.
Cardiology ; 103(1): 30-6, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15528898

RESUMO

BACKGROUND: Idiopathic ventricular tachycardia (VT) often originates from the right ventricular outflow tract (RVOT), but foci deep to the endocardium, in the epicardium, or in the left ventricle are not uncommon. Although these extra-RVOT foci can be targeted with ablation, risks involved are higher and success rates lower. Simple electrocardiographic (ECG) criteria allowing (1) discrimination of RVOT foci from extra-RVOT foci and (2) assessment of the chance of success of a right heart ablation procedure are desirable. METHODS: Twenty-five consecutive patients referred for radiofrequency (RF) ablation of idiopathic VT or severely symptomatic idiopathic ventricular premature contractions were included. Localization of VT origin and success rates of VT ablation in the RVOT were analyzed according to the ECG pattern. RESULTS: The analysis of the R wave in V2 was the strongest single predictor of whether the VT had an RVOT or an extra-RVOT origin. An R wave amplitude < or =30% of the QRS amplitude designated the VT focus in the RVOT with positive and negative predictive values of 95 and 100%, respectively. Analysis of R wave duration in V2 had similar predictive values, whereas the R/S transition zone in precordial leads had slightly lower predictive values. Seventeen of 20 arrhythmias (85%) with an R wave amplitude < or =30% of the QRS amplitude in V2 could be successfully abolished by an exclusively right heart procedure. CONCLUSIONS: The analysis of ECG pattern makes it possible to guide the management of patients with idiopathic VT in predicting the arrhythmias that can be safely targeted with RF ablation from the RVOT with high success rates.


Assuntos
Ablação por Cateter/métodos , Eletrocardiografia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Adulto , Idoso , Estimulação Cardíaca Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
17.
Heart Rhythm ; 1(3): 268-75, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15851168

RESUMO

OBJECTIVES: The aim of this study was to evaluate irrigated-tip catheter for ablation of intraatrial reentrant tachycardias late after surgical repair of congenital heart disease. BACKGROUND: In congenital heart disease patients, the right atrium can be markedly enlarged with areas of low blood flow. Radiofrequency (RF) lesion creation may be hampered by insufficient electrode cooling at sites with low blood flow. METHODS: Thirty-six consecutive patients with intraatrial reentrant tachycardia refractory to antiarrhythmic therapy from two centers were included in the study. Entrainment pacing and electroanatomic mapping (CARTO) were used to delineate reentrant circuits and critical isthmus sites. RF ablation was performed using an irrigated-tip catheter (Navistar Thermocool). RESULTS: Fifty-two intraatrial reentrant tachycardia circuits were identified, and 48 were targeted with RF ablation. RF ablation was performed using a mean of 13 +/- 11 irrigated RF applications per tachycardia isthmus with a mean power of 36 +/- 8 W. In a historical control group of congenital heart disease patients managed with conventional catheter ablation, the number of lesions per isthmus was higher (23 +/- 11) and mean power was lower (27 +/- 14 W). Acute success was achieved in 45 intraatrial reentrant tachycardias (94% of targeted tachycardias and 87% of all tachycardias). After a mean follow-up of 17 +/- 7 months, 33 (92%) of 36 patients were free of recurrence. Five patients (14%) developed paroxysmal atrial fibrillation. CONCLUSIONS: The combination of modern techniques including electroanatomic mapping and catheter irrigation allows safe and highly effective ablation of intraatrial reentrant tachycardia in patients with surgically repaired congenital heart disease.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/instrumentação , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Irrigação Terapêutica/instrumentação , Adolescente , Adulto , Idoso , Flutter Atrial/etiologia , Flutter Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Criança , Eletrocardiografia , Feminino , Átrios do Coração/fisiopatologia , Cardiopatias Congênitas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia por Reentrada no Nó Atrioventricular/etiologia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...