Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 140
Filtrar
1.
Cureus ; 16(6): e61640, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38966463

RESUMO

Atrial fibrillation (AF) is the most common cause of tachycardia-induced cardiomyopathy (TIC). A 75-year-old woman was referred to our hospital for catheter ablation for persistent AF. On admission, transthoracic echocardiography (TTE) revealed diffuse left ventricular (LV) hypokinesis, which was suspected to be due to TIC. Catheter ablation was performed on the fifth day of hospitalization, and Torsade de Pointes (TdP) appeared on the sixth day. The serum concentration of bepridil and potassium was below the reference level. An electrocardiogram revealed marked QT prolongation, giant-negative T waves, and T-wave alternans on the seventh day of hospitalization. Cardiac magnetic resonance imaging with no contrast indicated diffuse mild LV hypokinesis, mild prolonged native T1, and no evidence of myocardial edema at T2. Coronary angiography revealed normal coronary arteries, and the ergonovine stress test results were negative. The results for five long QT syndrome susceptibility genes, including the three major genes, were negative. Subsequently, QT prolongation, giant-negative T waves, and LV dysfunction improved without treatment. This case report highlights the importance of risk management for AF patients with TIC scheduled for catheter ablation and carefully evaluating the risks of QT prolongation. Moreover, patients with TIC can experience marked QT prolongation and TdP during the perioperative period of catheter ablation. Therefore, caution should be required.

2.
J Innov Card Rhythm Manag ; 15(7): 5936-5944, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39011460

RESUMO

The effect of irradiation during computed tomography (CT) imaging on implantable cardioverter-defibrillators (ICDs) has not been fully evaluated in various settings. The purposes of this study were to evaluate the occurrence of electromagnetic interference (EMI) during CT irradiation in various clinically available ICDs with phantom experiments and to determine the potential risks related to irradiation during CT imaging. Five types of clinically available ICDs from five manufacturers were tested. An ICD was combined with an electrocardiogram (ECG) simulator, mounted in a chest phantom, and subjected to CT imaging. Each ICD was irradiated at the maximal power level (tube voltage, 135 kVp; tube current, 510 mA; rotation time, 1.5 s). EMI was defined as oversensing, ventricular tachycardia/ventricular fibrillation (VT/VF) detection, noise, or shock delivery during CT imaging. For ICDs in which EMI was observed, EMI was then evaluated under 144 different irradiation conditions (tube voltage [four patterns from 80-135 kVp], tube current [six patterns from 50-550 mA], and rotation time [six patterns from 0.35-1.5 s]). Testing was also performed during irradiation at the typical doses in three clinical settings and in two settings with inappropriate irradiation of ICDs due to incorrect setup. Among the five ICDs, a shock was delivered by one ICD manufactured by Medtronic (Minneapolis, MN, USA) due to oversensing during irradiation, which occurred at the maximal power level. No oversensing was observed in other ICDs. In the malfunctioned ICD, oversensing was observed in 134 of 144 irradiation patterns, even at a low power in the ICD. The VF-detection criterion was fulfilled in 20 of 134 tests and was significantly associated with tube voltage, tube current, ration time, and tube voltage × rotation time interaction. Although oversensing was observed in three clinical settings (typical chest CT, CT coronary angiography after coronary artery bypass graft, and dynamic assessment for pleural tumors) and one situation during an incorrect scan range on the chest for head perfusion CT, they were not recognized as tachycardia beats. Oversensing was observed when scans were incorrectly set over the ICD during bolus tracking of contrast-enhanced CT. Maximal power CT imaging induced VT/VF detection and shock delivery in one model of ICD placed in a chest phantom. VT/VF detection was observed when tube voltages were high and irradiation times were longer. Oversensing can occur during inappropriate CT imaging, particularly when slices are positioned over the ICD.

3.
Respirol Case Rep ; 12(6): e01407, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38860177

RESUMO

This case report describes a 78-year-old man initially treated for pneumonia and lung abscess who was resistant to antimicrobial treatment and was eventually diagnosed with ciliated adenocarcinoma. Ciliated adenocarcinoma, a rare non-terminal respiratory unit (TRU)-type lung adenocarcinoma, presents a unique diagnostic challenge because of its similarity to pneumonia and lung abscesses. Morphologically, the ciliated adenocarcinoma in this case appeared to be a non-TRU type adenocarcinoma, with partial mucous epithelium, no visible extracellular mucus, thyroid transcription factor (TTF)-1 negativity, and mucin (MUC) 5AC positivity on immunostaining. The patient was considered to have ciliated adenocarcinoma based on the fact that the mucous epithelium was partial and extracellular mucus was not prominent. This case emphasizes the importance of considering malignancy in patients with non-resolving pulmonary infections.

4.
J Cardiol Cases ; 29(6): 248-250, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38826768

RESUMO

Primary cardiac angiosarcoma is a high-grade aggressive tumor with a poor prognosis and low incidence. We describe a case of cardiac angiosarcoma, with pulmonary and adrenal metastases, diagnosed via fluorodeoxyglucose-positron emission tomography/computed tomography-guided adrenal biopsy. Learning objective: Cardiac angiosarcoma should be considered in a patient with a cardiac mass with no tumor cells in the pericardial fluid. Fluorodeoxyglucose-positron emission tomography/computed tomography could be useful in determining the biopsy site.

6.
Circulation ; 150(1): 7-18, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38808522

RESUMO

BACKGROUND: Current cardiovascular magnetic resonance sequences cannot discriminate between different myocardial extracellular space (ECSs), including collagen, noncollagen, and inflammation. We sought to investigate whether cardiovascular magnetic resonance radiomics analysis can distinguish between noncollagen and inflammation from collagen in dilated cardiomyopathy. METHODS: We identified data from 132 patients with dilated cardiomyopathy scheduled for an invasive septal biopsy who underwent cardiovascular magnetic resonance at 3 T. Cardiovascular magnetic resonance imaging protocol included native and postcontrast T1 mapping and late gadolinium enhancement (LGE). Radiomic features were computed from the midseptal myocardium, near the biopsy region, on native T1, extracellular volume (ECV) map, and LGE images. Principal component analysis was used to reduce the number of radiomic features to 5 principal radiomics. Moreover, a correlation analysis was conducted to identify radiomic features exhibiting a strong correlation (r>0.9) with the 5 principal radiomics. Biopsy samples were used to quantify ECS, myocardial fibrosis, and inflammation. RESULTS: Four histopathological phenotypes were identified: low collagen (n=20), noncollagenous ECS expansion (n=49), mild to moderate collagenous ECS expansion (n=42), and severe collagenous ECS expansion (n=21). Noncollagenous expansion was associated with the highest risk of myocardial inflammation (65%). Although native T1 and ECV provided high diagnostic performance in differentiating severe fibrosis (C statistic, 0.90 and 0.90, respectively), their performance in differentiating between noncollagen and mild to moderate collagenous expansion decreased (C statistic: 0.59 and 0.55, respectively). Integration of ECV principal radiomics provided better discrimination and reclassification between noncollagen and mild to moderate collagen (C statistic, 0.79; net reclassification index, 0.83 [95% CI, 0.45-1.22]; P<0.001). There was a similar trend in the addition of native T1 principal radiomics (C statistic, 0.75; net reclassification index, 0.93 [95% CI, 0.56-1.29]; P<0.001) and LGE principal radiomics (C statistic, 0.74; net reclassification index, 0.59 [95% CI, 0.19-0.98]; P=0.004). Five radiomic features per sequence were identified with correlation analysis. They showed a similar improvement in performance for differentiating between noncollagen and mild to moderate collagen (native T1, ECV, LGE C statistic, 0.75, 0.77, and 0.71, respectively). These improvements remained significant when confined to a single radiomic feature (native T1, ECV, LGE C statistic, 0.71, 0.70, and 0.64, respectively). CONCLUSIONS: Radiomic features extracted from native T1, ECV, and LGE provide incremental information that improves our capability to discriminate noncollagenous expansion from mild to moderate collagen and could be useful for detecting subtle chronic inflammation in patients with dilated cardiomyopathy.


Assuntos
Cardiomiopatia Dilatada , Matriz Extracelular , Humanos , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/patologia , Matriz Extracelular/patologia , Matriz Extracelular/metabolismo , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Colágeno/metabolismo , Miocárdio/patologia , Idoso , Fibrose , Imageamento por Ressonância Magnética/métodos , Biópsia , Análise de Componente Principal , Radiômica
9.
Stud Health Technol Inform ; 310: 1554-1555, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38269742

RESUMO

An online health-monitoring system for COVID-19-infected patients who are staying in hotels and homes was developed using geographical information systems. This system provides display functions for sending health observation forms to infected residents, scoring for medical risk assessment, and centralized management. More than 1,146,000 health observation records were registered in November 2022, and the system contributed to maintaining the functionality of the municipal health center in Sapporo, Japan.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Instalações de Saúde , Sistemas de Informação Geográfica , Japão/epidemiologia , Sistemas Computadorizados de Registros Médicos
11.
Biosci Biotechnol Biochem ; 88(1): 107-110, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-37881018

RESUMO

Hair loss is a commonly encountered problem. In this study, hair growth was enhanced by daily oral ingestion of salmon nasal cartilage proteoglycan (PG) in mice. Proteoglycan stimulated vesicular endothelial growth factor production in human follicle dermal papilla cells through insulin growth factor-1 receptor signaling, suggesting the possibility of hair loss improvement by PG ingestion.


Assuntos
Cartilagens Nasais , Proteoglicanas , Humanos , Animais , Camundongos , Proteoglicanas/farmacologia , Proteoglicanas/metabolismo , Salmão , Cabelo , Alopecia , Folículo Piloso , Células Cultivadas
14.
J Cardiol Cases ; 28(1): 16-20, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37360826

RESUMO

An 89-year-old man with an intermittent 2:1 second-degree atrioventricular block received a permanent pacemaker (Medtronic Azure XT DR; Medtronic Inc., Minneapolis, MN, USA). Reactive antitachycardia pacing (ATP) was engaged in all transmissions 3 weeks later. Intracardiac recordings revealed a far-field R wave (FFRW) oversensing, occurring between atrial waves and premature atrial contractions. This event triggered the delivery of reactive ATP, which induced atrial fibrillation. A 79-year-old man underwent permanent pacemaker implantation for an intermittent complete atrioventricular block. One month after implantation, reactive ATP was initiated. The atrial electrogram of intracardiac recordings revealed one being a spontaneous P wave and the other an oversensed R wave. The criterion for an atrial tachycardia was fulfilled, and the device initiated reactive ATP. As a result, atrial fibrillation was induced by inappropriate reactive ATP. It was difficult to completely avoid inappropriate reactive ATP. Finally, we discontinued reactive ATP. The two cases presented in this study demonstrate the possibility of inappropriate reactive ATP due to FFRW oversensing, with the inappropriate reactive ATP inducing atrial fibrillation. All patients treated with reactive ATP should be carefully assessed for the presence of FFRW oversensing during pacemaker implantation and during the follow-up period. Learning objective: We present two cases of inappropriate reactive ATP caused by far-field R-wave oversensing. Inappropriate reactive ATP has not been previously reported. Therefore, we suggest that all patients provided with a DDD pacemaker should be carefully assessed for the presence of FFRW oversensing during pacemaker implantation and during the follow-up period. Remote monitoring enables very early detection of inappropriate reactive ATP delivery for rapid implementation of preventive measures.

16.
Circ J ; 87(5): 629-639, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-36928102

RESUMO

BACKGROUND: The simple risk index recorded in the emergency room (ER-SRI), which is calculated using the formula (heart rate × [age / 10]2) / systolic blood pressure, was shown to be able to stratify the prognosis in ST-elevation myocardial infarction (STEMI) patients. However, the prognostic impact of the prehospital simple risk index (Pre-SRI) remains unknown.Methods and Results: This study enrolled 2,047 STEMI patients from the Mie Acute Coronary Syndrome (ACS) registry. Pre-SRI was calculated using prehospital data and ER-SRI was calculated using emergency room data. The primary endpoint was 30-day all-cause mortality. The cut-off values of Pre-SRI and ER-SRI for predicting 30-day mortality were 34.8 and 34.1, with accuracies of 0.816 and 0.826 based on receiver operating characteristic analyses (P<0.001 for both). There was no difference in the accuracy of the 2 indices. Multivariate Cox regression analysis demonstrated that a High Pre-SRI (≥34) was a significant independent predictor of 30-day mortality. With combined Pre-SRI and ER-SRI assessment, patients with High Pre-SRI/High ER-SRI showed significantly higher mortality than those with High Pre-SRI/Low ER-SRI, Low Pre-SRI/High ER-SRI, and Low Pre-SRI/Low ER-SRI (P<0.001). The addition of High Pre-SRI to High ER-SRI showed incremental prognostic value of the Pre-SRI. CONCLUSIONS: Pre-SRI can identify high-risk STEMI patients at an early stage and combined assessment with Pre-SRI and ER-SRI could be of incremental prognostic value for risk stratification in STEMI patients.


Assuntos
Síndrome Coronariana Aguda , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Criança , Prognóstico , Risco , Síndrome Coronariana Aguda/diagnóstico , Serviço Hospitalar de Emergência , Medição de Risco
18.
Int Heart J ; 64(1): 85-89, 2023 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-36682768

RESUMO

Coronavirus disease 2019 (COVID-19) associated myocardial injury was caused by various mechanisms. We herein describe 2 cases presenting different types of myocardial injury due to Omicron variant. In both patients, diffuse reduced left ventricular (LV) wall motion in transthoracic echocardiography, electrocardiographic abnormality, and elevated myocardial enzymes were demonstrated. In addition, cardiovascular magnetic resonance (CMR) findings fulfilled the 2018 Lake Louise Criteria (LLC) for myocarditis. However, histological findings in 1 patient showed inflammatory cell infiltration with myocyte degeneration, while those in the other showed interstitial edema without inflammatory cell infiltration. Histological findings were crucial for a differential diagnosis of myocardial injury due to Omicron variant.


Assuntos
COVID-19 , Traumatismos Cardíacos , Miocardite , Humanos , SARS-CoV-2 , COVID-19/complicações , Miocardite/diagnóstico , Miocardite/etiologia , Miocárdio/patologia
20.
J Cardiol ; 81(5): 476-484, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36503064

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) improved outcome of patients with severe aortic valve stenosis (AS). Myocardial fibrosis is associated with AS-related pathological left ventricular (LV) remodeling and predicts cardiovascular mortality after TAVI. The present study aimed to investigate the impact of preoperative extracellular volume (ECV) assessed by computed tomography (CT) on left ventricular mass (LVM) regression and clinical outcomes in severe AS patients after TAVI. METHODS: We examined 71 consecutive severe AS patients who underwent CT with ECV determination before TAVI. ECV was calculated as the ratio of the change in Hounsfield units in the myocardium and LV blood before and after contrast administration, multiplied by (1-hematocrit). Delayed scan was performed at 5 min after contrast injection. Echocardiography was performed before and 6 months after TAVI. The primary endpoint was heart failure (HF) hospitalization after TAVI. Patients were divided into two subgroups according to the median value of global ECV with 32 % (Low-ECV group: n = 35, and High-ECV group: n = 36). RESULTS: No significant differences were observed in background characteristics between the 2 groups. However, the preoperative LV ejection fraction and LVM index were similar between the 2 groups, the Low-ECV group had greater LVM index reduction than the High-CV group after 6 months (p < 0.001). Kaplan-Meier curves demonstrated that the High-ECV group had significantly higher rate of HF hospitalization than the Low-ECV group (p = 0.016). In addition, multivariate analyses identified high global ECV as an independent predictor of HF hospitalization (HR 10.8, 95 % confidence interval 1.36 to 84.8, p = 0.024). CONCLUSION: The low preoperative ECV assessed by CT is associated with the greater LVM regression, and predict better outcome in AS patients after TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Função Ventricular Esquerda , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Volume Sistólico , Tomografia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...