Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
2.
Circ Cardiovasc Interv ; : e013903, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38934113

RESUMO

BACKGROUND: SAPIEN3 (S3) is a ubiquitous redo-transcatheter aortic valve (TAV) replacement alternative for degenerated Evolut valves, but S3 sizing for S3-in-Evolut remains unclear. We sought to compare the impact of in vivo computed tomography (CT)-sizing on redo-TAV feasibility for S3-in-Evolut with traditional bench-sizing. METHODS: CT scans of 290 patients treated using Evolut R/PRO/PRO+ between July 2015 and December 2021 were analyzed. S3-in-Evolut was simulated using S3 outflow/neoskirt plane (NSP) at node-6, -5, and -4. CT-sizing for S3 was determined by averaging 4 areas of the Evolut stent frame at NSP level and 3 nodes below. Redo-TAV was deemed feasible if the NSP was below the coronaries, or the narrowest valve (virtual S3)-to-aorta distance was >4 mm. Risk of prosthesis-patient mismatch was estimated using predicted indexed-effective orifice area. RESULTS: Compared with bench-sizing, CT-sizing yielded smaller S3 size in 82% at node-6, 81% at node-5, and 84% at node-4. Factors associated with CT-sizing less than bench-sizing were larger index Evolut size, underexpansion of index Evolut, and shallower implant depth (all P<0.05). CT-sizing increased redo-TAV feasibility by +8% at node-6, +10% at node-5, and +4% at node-4. Redo-TAV feasibility increased with annulus size, sinotubular junction dimensions, coronary heights, index Evolut size, deeper Evolut implant depth, and lower NSP levels (all P<0.05). CT-sizing had a slightly higher estimated risk of severe prosthesis-patient mismatch (9% at node-6, 7% at node-5, and 6% at node-4), which could be mitigated by changing the NSP. CONCLUSIONS: CT-sizing for S3-in-Evolut is associated with higher feasibility of redo-TAV compared with bench-sizing, potentially reducing the risk of excessive oversizing and S3 underexpansion. Further validation using real-world clinical data is necessary.

3.
JACC Case Rep ; 29(12): 102372, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38774636

RESUMO

The diagnostic approach toward the management of cardiac implantable electronic device-related tricuspid regurgitation is challenging and undefined. Functional cardiac computed tomography angiography provides a complementary role to echocardiography in the evaluation of lead-leaflet interaction which can help the clinical decision-making process, as presented in this case series.

4.
Struct Heart ; 8(3): 100276, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38799806

RESUMO

Background: Bioprosthetic valve fracture (BVF) during valve-in-valve TAVR (transcatheter aortic valve replacement) is a procedural adjunct designed to optimize the expansion of the transcatheter heart valve and reduce patient-prosthesis mismatch by using a high-pressure balloon to intentionally fracture the surgical heart valve (SHV). Methods: We performed bench testing on 15 bioprosthetic SHV to examine the optimal balloon size and pressure for BVF. We assessed morphological changes and expansion of SHV by computed tomography angiography. Successful BVF was defined as balloon waist disappearance on fluoroscopy and/or sudden pressure drop during balloon inflation. Results: Nine valves met the definition of BVF, 3 of which were confirmed by disruption of the stent frame. We classified surgical valves into 3 subsets: 1) fracturable with metal stent frame (MSF), 2) fracturable with polymer stent frame (PSF) and 3) nonfracturable. In general, valves with MSF were fractured using a balloon size = true internal diameter plus 3-5 mm inflated at high pressure (16-20 ATM) whereas valves with PSF could be fractured with a balloon size = true internal diameter plus 3-5 mm and lower balloon pressure (6-14 ATM). Gains in computed tomography angiography derived inflow area after BVF were 12.3% for MSF and 3.6% for PSF SHV. Conclusions: Gains in CT-determined valve area after BVF depend on the physical properties of the SHV, which in turn influences pressure thresholds and balloon sizing strategy for optimal BVF. Elastic recoil of PSF valves limits the gains in inflow area after BVF.

5.
J Pediatr Gastroenterol Nutr ; 78(3): 514-523, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38504406

RESUMO

OBJECTIVES: To holistically evaluate neurodevelopmental outcomes and quality of life (QOL) of Japanese patients with biliary atresia (BA) and to investigate the factors associated with the outcomes. METHODS: This study enrolled patients with BA aged 5-18 years who visited Osaka University Hospital in 2021. Neurodevelopmental assessments were performed to evaluate intellectual ability, cognitive functions and adaptive skill levels. Furthermore, emotional and behavioral issues, characteristics of attention deficit hyperactivity disorder, and QOL were concomitantly assessed in the same cohort. Biochemical and social factors associated with the results were examined. RESULTS: Fifty-three patients, with a median age of 11.2 years were included in the analyses. Patients with BA had a significantly lower Full-Scale Intelligence Quotient or developmental quotient (FSIQ/DQ) score and Vineland Adaptive Behavior Scale (VABS) composite score than the general Japanese population. Household education level and short stature were associated with low and borderline FSIQ/DQ and VABS composite scores, respectively. Among patients with low and borderline FSIQ/DQ scores, those with average or high VABS composite scores received significantly less neuroeducational care than those with low and borderline VABS composite scores. Despite the low FSIQ/DQ and VABS composite scores, the total QOL scores were higher than those of the general population. CONCLUSION: Patients with BA had intellectual and behavioral impairments. Notably, patients with intellectual impairments are overlooked and not followed up, especially if adaptive skills are maintained.


Assuntos
Atresia Biliar , Qualidade de Vida , Criança , Humanos , Atresia Biliar/complicações , Testes de Inteligência , Cognição
6.
J Cardiol ; 83(6): 351-358, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38432474

RESUMO

Transcatheter aortic valve replacement (TAVR) has emerged as a preferred treatment modality for aortic stenosis, marking a significant advancement in cardiac interventions. Transcatheter heart valves (THVs) have also received approval for treating failed bioprosthetic valves and rings across aortic, mitral, tricuspid, and pulmonic positions. Unlike surgically implanted valves, which are sewn into the annulus, THVs are anchored through relative oversizing. Although THVs are designed to function optimally in a fully expanded state, they exhibit a certain degree of tolerance to underexpansion. However, significant deformation beyond this tolerance can adversely affect the valve's hemodynamics and durability, ultimately impacting patient outcomes. Such post-implantation deviations from the valve's intended three-dimensional design are influenced by a variety of physiological and anatomical factors unique to each patient and procedure, leading to underexpansion, eccentric expansion, and vertical deformation. These deformation patterns increase leaflet stress and strain, potentially causing fatigue and damage. This review article delves into the extent of THV deformation, its impact on leaflet function, hypoattenuating leaflet thickening, and structural valve degeneration. It provides an in-depth analysis of deformation specifics in different procedural contexts, including TAVR in native aortic stenosis, aortic and mitral valve-in-valve procedures, and redo-TAVR. Additionally, the review discusses strategies to mitigate THV deformation during the procedure, offering insights into potential solutions to these challenges.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese
7.
Ann Thorac Surg ; 117(6): 1154-1162, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38382704

RESUMO

BACKGROUND: Selection of transcatheter valve size using preprocedural computed tomography (CT) is standardized and well established. However, valve sizing for surgical aortic valve replacement (SAVR) is currently performed intraoperatively by using sizers, which may result in variation among operators and risk for prosthesis-patient mismatch. This study evaluated the usefulness of CT annulus measurement for SAVR valve sizing. METHODS: This study included patients who underwent SAVR using Inspiris or Magna Ease and received preoperative electrocardiogram-gated CT imaging. Starting from June 2022, study investigators applied a CT sizing algorithm using CT-derived annulus size to guide minimum SAVR label size. The final decision of valve selection was left to the operating surgeon during SAVR. The study compared the appropriateness of valve selection (comparing implanted size with CT-predicted size) and prosthesis-patient mismatch rates without aortic root enlargement between 2 cohorts: 102 cases since June 2022 (CT sizing cohort) and 180 cases from 2020 to 2021 (conventional sizing cohort). RESULTS: Implanted size smaller than CT predicted size and severe prosthesis-patient mismatch were significantly lower by CT sizing than by conventional sizing (12% vs 31% [P = .001] and 0% vs 6% [P = .039], respectively). Interoperator variability was a factor associated with implanted size smaller than CT predicted with conventional sizing, whereas it became nonsignificant with CT sizing. CONCLUSIONS: Applying CT sizing to SAVR led to improved valve size selection, less prosthesis-patient mismatch, and less interoperator variability. CT sizing for SAVR could also be used to predict prosthesis-patient mismatch before SAVR and identify patients who need aortic root enlargement.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Tomografia Computadorizada por Raios X/métodos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Idoso , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Desenho de Prótese , Idoso de 80 Anos ou mais , Cuidados Pré-Operatórios/métodos , Implante de Prótese de Valva Cardíaca/métodos , Substituição da Valva Aórtica Transcateter/métodos
8.
JACC Cardiovasc Imaging ; 17(4): 396-407, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37921717

RESUMO

BACKGROUND: Quantification of myocardial changes in severe aortic stenosis (AS) is prognostically important. The potential for comprehensive myocardial assessment pre-transcatheter aortic valve replacement (TAVR) by computed tomography angiography (CTA) is unknown. OBJECTIVES: This study sought to evaluate whether quantification of left ventricular (LV) extracellular volume-a marker of myocardial fibrosis-and global longitudinal strain-a marker of myocardial deformation-at baseline CTA associate with post-TAVR outcomes. METHODS: Consecutive patients with symptomatic severe AS between January 2021 and June 2022 who underwent pre-TAVR CTA were included. Computed tomography extracellular volume (CT-ECV) was derived from septum tracing after generating the 3-dimensional CT-ECV map. Computed tomography global longitudinal strain (CT-GLS) used semi-automated feature tracking analysis. The clinical endpoint was the composite outcome of all-cause mortality and heart failure hospitalization. RESULTS: Among the 300 patients (80.0 ± 9.4 years of age, 45% female, median Society of Thoracic Surgeons Predicted Risk of Mortality score 2.80%), the left ventricular ejection fraction (LVEF) was 58% ± 12%, the median CT-ECV was 28.5% (IQR: 26.2%-32.1%), and the median CT-GLS was -20.1% (IQR: -23.8% to -16.3%). Over a median follow-up of 16 months (IQR: 12-22 months), 38 deaths and 70 composite outcomes occurred. Multivariable Cox proportional hazards model, accounting for clinical and echocardiographic variables, demonstrated that CT-ECV (HR: 1.09 [95% CI: 1.02-1.16]; P = 0.008) and CT-GLS (HR: 1.07 [95% CI: 1.01-1.13]; P = 0.017) associated with the composite outcome. In combination, elevated CT-ECV and CT-GLS (above median for each) showed a stronger association with the outcome (HR: 7.14 [95% CI: 2.63-19.36]; P < 0.001). CONCLUSIONS: Comprehensive myocardial quantification of CT-ECV and CT-GLS associated with post-TAVR outcomes in a contemporary low-risk cohort with mostly preserved LVEF. Whether these imaging biomarkers can be potentially used for the decision making including timing of AS intervention and post-TAVR follow-up will require integration into future clinical trials.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Função Ventricular Esquerda , Volume Sistólico , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Estudos Retrospectivos
10.
Circ Cardiovasc Interv ; 16(11): e012966, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37988437

RESUMO

Transcatheter aortic valve replacement (TAVR) is increasingly being performed in younger and lower surgical risk patients. Reintervention for failed transcatheter heart valves will likely increase in the future as younger patients are expected to outlive the initial bioprosthesis. While redo-TAVR has emerged as an attractive and less invasive alternative to surgical explantation (TAVR-explant) to treat transcatheter heart valve failure, it may not be feasible in all patients due to the risk of coronary obstruction and impaired coronary access. Conversely, TAVR-explant can be offered to most patients who are surgical candidates, but the reported outcomes have shown high mortality and morbidity. This review provides the latest evidence, current challenges, and future directions on redo-TAVR and TAVR-explant for transcatheter heart valve failure, to guide aortic valve reintervention and facilitate patients' lifetime management of aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos
11.
Circ Cardiovasc Interv ; 16(11): e013497, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37988440

RESUMO

BACKGROUND: Our aim was to assess the feasibility of repeat transcatheter aortic valve (TAV) replacement for degenerated Sapien3 (S3) prostheses by simulating subsequent implantation of S3 or Evolut, using in vivo computed tomography-based sizing and the impact on coronary and patient-prosthesis mismatch risks. METHODS: Computed tomography scans from 356 patients with prior S3 TAV replacement implantation were analyzed. The in vivo sizing for second TAV based on averaged area of 3 levels of outflow, mid (narrowest) and inflow, was compared with in vitro recommendations, that is, same size as index S3 for second S3 and 1 size larger for Evolut. Risks of coronary obstruction and patient-prosthesis mismatch were determined by valve-to-aorta distance and estimated effective orifice area, respectively. RESULTS: Overall, the majority of patients (n=328; 92.1%) had underexpanded index S3 with an expansion area of 94% (91%-97%), leading to significant differences in size selection of the second TAV between in vivo and in vitro sizing strategies. Expansion area <89% served as a threshold, resulting in 1 size smaller than the in vitro recommendations were selected in 45 patients (13%) for S3-in-S3 and 13 (4%) for Evolut-in-S3, while the remaining patients followed in vitro recommendations (P<0.01, in vivo versus in vitro sizing). Overall, 57% of total patients for S3-in-S3 simulation and 60% for Evolut-in-S3 were considered low risk for coronary complications. Deep index S3 implantation (odds ratio, 0.76 [interquartile range, 0.67-0.87]; P<0.001) and selecting Evolut as the second TAV (11% risk reduction in intermediate- or high-risk patients) reduced coronary risk. Estimated moderate or severe patient-prosthesis mismatch risk was 21% for S3-in-S3 and 1% for Evolut-in-S3, assuming optimal expansion of the second TAV. CONCLUSIONS: Redo-TAV replacement with S3-in-S3 and Evolut-in-S3 could be feasible with low risk to coronaries in ≈60% of patients, while the remaining 40% will be at intermediate or high risk. The feasibility of redo-TAV replacement is influenced by sizing strategy, type of second TAV, native annular anatomy, and implant depth.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos de Viabilidade , Resultado do Tratamento , Desenho de Prótese , Tomografia Computadorizada por Raios X
12.
EuroIntervention ; 19(11): e937-e947, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-37899719

RESUMO

BACKGROUND: The use of oversizing in mitral valve-in-valve (MViV) procedures can lead to non-uniform expansion of transcatheter heart valves (THV). This may have implications for THV durability. AIMS: The objective of this study was to assess the extent and predictors of THV deformation in MViV procedures. METHODS: We examined 33 patients who underwent MViV with SAPIEN prostheses. The extent of THV deformation (deformation index, eccentricity, neosinus volume, asymmetric leaflet expansion and vertical deformation) and hypoattenuating leaflet thickening (HALT) were assessed using cardiac computed tomography (CT), performed prospectively at 30 days post-procedure. For descriptive purposes, the THV deformation index was calculated, with values >1.00 representing a more hourglass shape. RESULTS: Non-uniform underexpansion of THV was common after MViV implantation, with a median expansion area of 74.0% (interquartile range 68.1-84.1) at the narrowest level and a THV deformation index of 1.21 (1.13-1.29), but circularity was maintained with eccentricity ranging from 0.24 to 0.28. The degree of oversizing was a key factor associated with greater underexpansion and a higher deformation index (ß=-0.634; p<0.001; ß=0.594; p<0.001, respectively). Overall, the incidence of HALT on the 30-day postprocedural CT was 27.3% (9 of 33). Most patients (32 of 33) were on anticoagulation therapy, but the prothrombin time and international normalised ratio (PT-INR) at the time of the CT scan was <2.5 in 23 of 32 patients. Among patients with a PT-INR of <2.5, HALT was predominantly observed with a high THV deformation index of ≥1.18. CONCLUSIONS: THV deformation, i.e., underexpansion and an hourglass shape, commonly occurs after MViV implantation and is negatively affected by excessive oversizing. Optimising THV expansion during MViV could potentially prevent HALT.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Desenho de Prótese , Valva Aórtica/cirurgia
13.
J Cardiovasc Comput Tomogr ; 17(3): 222-225, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36922309

RESUMO

BACKGROUND: Computed tomography angiography (CTA) assessment of myocardial extracellular volume fraction (CT-ECV) is feasible, although the protocols for imaging acquisition and post-processing methodology have varied. We aimed to identify a pragmatic protocol for CT-ECV assessment encompassing both imaging acquisition and post-processing methodologies to facilitate its clinical implementation. METHODS: We evaluated consecutive patients with severe aortic stenosis undergoing evaluation for transcatheter aortic valve replacement (TAVR). Pre-contrast and 3-min-delayed CTA were obtained in systole using either helical prospective-ECG-triggered (high-pitch) or axial sequential-ECG-gated acquisition, adding to standard TAVR CTA protocol. Using a dedicated software for co-registration of CTA datasets, three methodologies for ECV measurement were evaluated: (1) mid-septum region of interest (Septal ECV), (2) averaged-global ECV (Global ECV) encompassing 16-AHA segments, and (3) average of septal and lateral segments (Averaged ECVsep and Averaged ECVlat). RESULTS: Among the 142 patients enrolled (median â€‹= â€‹81 years, 44% females), 8 were excluded due to significant imaging artifacts precluding Global ECV assessment. High-pitch scan mode was performed in 68 patients (48%). Suboptimal image quality for Global ECV assessment was associated with high-pitch scan mode (odds ratio: OR â€‹= â€‹2.26, p â€‹= â€‹0.036), along with the presence of intracardiac leads (OR â€‹= â€‹4.91, p â€‹= â€‹0.002), and BMI≥35 â€‹kg/m2 (OR â€‹= â€‹2.80, p â€‹= â€‹0.026). Septal ECV [median â€‹= â€‹29.4%] and Averaged ECVsep [29.0%] were similar (p â€‹= â€‹0.108), while Averaged ECVlat [27.5%] was lower than Averaged ECVsep (p â€‹< â€‹0.001), resulting in lower Global ECV [28.6%]. CONCLUSIONS: Myocardial CT-ECV assessment is feasible using a systolic sequential acquisition pre-contrast, and similar additional 3-min delayed scan. Septal ECV measurement provides similar values to Global ECV and is equally reproducible.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Masculino , Estudos Prospectivos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
14.
JACC Cardiovasc Interv ; 16(5): 515-526, 2023 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-36922036

RESUMO

BACKGROUND: Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) may be associated with adverse hemodynamics, which might affect clinical outcomes. OBJECTIVES: This study sought to evaluate the extent and predictors of transcatheter heart valve (THV) deformity in ViV TAVR and the relation to postprocedural hemodynamics. METHODS: We examined 53 patients who underwent ViV TAVR in surgical heart valves with self-expanding Evolut prostheses. THV deformation was examined using cardiac computed tomography prospectively performed 30 days after ViV TAVR, and correlated with 30-day echocardiographic hemodynamic data. RESULTS: Near complete expansion of the functional portion of the implanted ViV prostheses (ie, >90%) was observed in 16 (30.2%) patients. Factors related to greater expansion of the functional portion and consequently larger neosinus volume were absence of polymer surgical frame, higher implantation and use of balloon aortic valvuloplasty or bioprosthetic valve fracture during the procedure (all P < 0.05). Underexpansion of the functional portion, but not the valve inflow frame, was closely associated with mean gradient and effective orifice area at 30 days on echocardiography, with and without adjustment for the sizes of the THV and surgical heart valve. CONCLUSIONS: Underexpansion of the functional portion of THV prostheses is common during ViV TAVR, occurs more frequently with deep implantation and the presence of a polymer surgical stent frame, and is associated with worse postprocedural hemodynamics. Procedural techniques, such as higher implantation and balloon postdilatation, may be used to help overcome problems with THV underexpansion and improve clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia
15.
medRxiv ; 2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36824921

RESUMO

Background: Diffuse myocardial fibrosis (DMF) quantified by extracellular volume (ECV) may represent a vulnerable phenotype and associate with life threatening ventricular arrhythmias more than focal myocardial fibrosis. This principle remains important because 1) risk stratification for implantable cardioverter defibrillators (ICD) remains challenging, and 2) DMF may respond to current or emerging medical therapies (reversible substrate). Objectives: To evaluate the association between quantified by ECV in myocardium without focal fibrosis by late gadolinium enhancement (LGE) with time from ICD implantation to 1) appropriate shock, or 2) shock or anti-tachycardia pacing. Methods: Among patients referred for cardiovascular magnetic resonance (CMR) without congenital disease, hypertrophic cardiomyopathy, or amyloidosis who received ICDs (n=215), we used Cox regression to associate ECV with incident ICD therapy. Results: After a median of 2.9 (IQR 1.5-4.2) years, 25 surviving patients experienced ICD shock and 44 experienced shock or anti-tachycardia pacing. ECV ranged from 20.2% to 39.4%. No patient with ECV<25% experienced an ICD shock. ECV associated with both endpoints, e.g., hazard ratio 2.17 (95%CI 1.17-4.00) for every 5% increase in ECV, p=0.014 in a stepwise model for ICD shock adjusting for ICD indication, age, smoking, atrial fibrillation, and myocardial infarction, whereas focal fibrosis by LGE and global longitudinal strain (GLS) did not. Conclusions: DMF measured by ECV associates with ventricular arrhythmias requiring ICD therapy in a dose-response fashion, even adjusting for potential confounding variables, focal fibrosis by LGE, and GLS. ECV-based risk stratification and DMF representing a therapeutic target to prevent ventricular arrhythmia warrant further investigation.

16.
Circ Cardiovasc Interv ; 16(2): e012486, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36802803

RESUMO

BACKGROUND: Consensus-driven criteria have recently been proposed for prediction of mitral transcatheter edge-to-edge repair outcomes, yet validation for response to therapy is needed. We examined the relation between contemporary criteria and outcomes with mitral transcatheter edge-to-edge repair therapy. METHODS: Mitral transcatheter edge-to-edge repair patients were classified according to anatomic and clinical criteria (1) Heart Valve Collaboratory criteria for nonsuitability; (2) commercial indications (suitable); and (3) neither (ie, intermediate). Analyses for Mitral Valve Academic Research Consortium-defined outcomes of reduction in mitral regurgitation and survival were performed. RESULTS: Among 386 patients (median age, 82 years; 48% women), the most common classification was intermediate (46%), with 138 patients (36%) and 70 patients (18%) in the suitable and nonsuitable categories, respectively. Nonsuitable classification was related to prior valve surgery, smaller mitral valve area, type IIIa morphology, larger coaptation depth, and shorter posterior leaflet. Nonsuitable classification was associated with less technical success (P<0.001) and survival free of mortality, heart failure hospitalization, and mitral surgery (P<0.001). Among the nonsuitable patients, technical failure or any 30-day major adverse cardiac event occurred in 25.7%. Nevertheless, in these patients, acceptable mitral regurgitation reduction without adverse events still occurred in 69%, and their 1-year survival with mild or no symptoms was 52%. CONCLUSIONS: Contemporary classification criteria identify patients less suitable for mitral transcatheter edge-to-edge repair with respect to acute procedural success and survival, though patients most commonly fit an intermediate category. In experienced centers, sufficient mitral regurgitation reduction can be achieved safely in the selected patients even with challenging anatomy.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Feminino , Idoso de 80 Anos ou mais , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Cateterismo Cardíaco/efeitos adversos
17.
J Am Soc Echocardiogr ; 36(1): 87-95, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36049594

RESUMO

BACKGROUND: Spontaneous echocardiographic contrast (SEC) in the left atrium can occur with transcatheter edge-to-edge repair (TEER), but the clinical significance is unknown. METHODS: The authors examined the clinical association of the procedural appearance of SEC in 316 patients (median age, 82 years; interquartile range, 76-86 years; 43.4% women) undergoing TEER with the MitraClip for mitral regurgitation. Acute, 30-day, and 2-year clinical outcomes were analyzed. RESULTS: SEC was common, occurring following device implantation in 106 patients (34%). Although the occurrence of SEC was not related to clinical characteristics, such as atrial fibrillation, anticoagulant use, or left ventricular function, there was a strong relation to beneficial outcomes with TEER. The frequency of optimal reduction in mitral regurgitation was higher in patients who had SEC (99.1% vs 72.9%, P < .001). Survival was greater, with a 2-year estimate for freedom from all-cause mortality of 88.4% versus 71.5% (log-rank P = .004). Importantly, the higher survival observed in patients with SEC was present without increased rates of procedural complications or stroke and remained significant in multivariate analyses that adjusted for baseline clinical and echocardiographic variables (P = .01). CONCLUSIONS: The occurrence of SEC in patients with TEER is associated with beneficial acute and intermediate-term outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Feminino , Idoso de 80 Anos ou mais , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Valva Mitral/diagnóstico por imagem , Resultado do Tratamento , Ecocardiografia/efeitos adversos , Fatores de Risco , Meios de Contraste , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco
18.
JACC Cardiovasc Interv ; 15(17): 1697-1707, 2022 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-36075641

RESUMO

BACKGROUND: Prediction of the clinical response to transcatheter edge-to-edge repair (TEER) remains a vexing challenge. OBJECTIVES: This study sought to examine the relation between hemodynamic profiles and outcomes following mitral TEER. METHODS: Among 378 patients (median age 82 years; 43.9% women), 3 hemodynamic profiles using residual left atrial pressure (LAP) and mitral regurgitation (MR) were defined: type I (optimal), grade ≤1 MR and mean LAP (mLAP) ≤15 mm Hg; type II (mixed), MR grade >1 or mLAP >15 mm Hg; and type III (poor), MR grade >1 and mLAP >15 mm Hg. The discrimination of these profiles for predicting outcomes was examined. A positive clinical response to TEER was defined as improvement in New York Heart Association functional class ≥I grade at 1 year without heart failure rehospitalization or death. RESULTS: There were 148 (39.0%) patients classified as optimal (type I), 187 (49.0%) patients as mixed (type II), and 43 (11.0%) patients as poor (type III). For all-cause mortality, survival at 1 year was 91.6%, 82.6%, and 67.9% for types I, II, and III, respectively (HR: 2.13; 95% CI: 1.44-3.15; P < 0.001). For the composite endpoint of all-cause mortality and rehospitalization for heart failure, event-free survival at 1 year was 84.1%, 70.7%, and 53.2% for types I, II, and III, respectively (HR: 1.93; 95% CI: 1.41-2.65; P < 0.001). Hemodynamic profiling was strongly associated with a positive response to TEER, occurring in 73.9%, 57.0%, 35.0%, for types I, II, and III, respectively (P < 0.001). CONCLUSIONS: In patients undergoing mitral TEER, hemodynamic profiling is prognostic, with superior survival occurring among patients with optimal reduction in MR and normal postprocedural LAP.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Recuperação de Função Fisiológica , Fatores de Risco , Resultado do Tratamento
19.
Pediatr Int ; 64(1): e15298, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36134643

RESUMO

BACKGROUND: We aimed to compare the profile of the Wechsler Intelligence Scale for Children Fourth Edition (WISC-IV) between Japanese schoolchildren born very preterm (VP) and with very low birthweight (VLBW) and those with attention deficit hyperactivity disorder (ADHD), and to identify the specific neurocognitive characteristics of VLBW/VP children. METHODS: The VLBW/VP group in the present study included 50 (19 male, 31 female) first- to third-grade elementary school children born between January 2008 and February 2013 at Osaka Medical and Pharmaceutical University Hospital and Saiseikai Suita Hospital with birthweights <1,500 g and <32 gestational weeks. The ADHD group included 18 (13 male, 5 female) first- to third-grade elementary school children who visited Osaka Medical and Pharmaceutical University Hospital between January 2019 and October 2021. Full-scale intelligence quotient scores, four indices, and 12 subtests of the WISC-IV were calculated for all participants and compared between the VLBW/VP and ADHD groups. We assessed whether the patients' clinical history was associated with a low score on the cancellation task in the VLBW/VP group. RESULTS: The WISC-IV profiles showed similar between-group patterns, and the VLBW/VP group had lower cancellation task scores than the ADHD group. CONCLUSIONS: This is the first study to compare WISC-IV profiles between VLBW/VP children and those with ADHD. Further investigation is needed on the association between academic performance and the score of the cancellation task, and the neural mechanism of low performance for cancellation tasks in VLBW/VP children.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade , Transtorno do Deficit de Atenção com Hiperatividade/diagnóstico , Transtorno do Deficit de Atenção com Hiperatividade/psicologia , Peso ao Nascer , Criança , Feminino , Humanos , Recém-Nascido , Recém-Nascido de muito Baixo Peso , Masculino , Preparações Farmacêuticas , Escalas de Wechsler
20.
Pediatr Int ; 64(1): e15131, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35895494

RESUMO

BACKGROUND: This study investigated the impact of coronavirus disease 2019 pandemic school closures on the mental health of school students with chronic diseases. METHODS: Questionnaires were distributed to students from 4th-9th grade diagnosed with chronic diseases at Osaka Medical College Hospital and their parents or caregivers. Questionnaires from 286 families were returned by mail after the schools reopened. The students were divided into the "psychosomatic disorder" group (group P, n = 42), the "developmental disorder" group (group D, n = 89), and the "other disease" group (group O, n = 155). Using students' self-reports on the Questionnaire for Triage and Assessment with 30 items, we assessed the proportion of students with a high risk of psychosomatic disorder in three groups. We investigated how the students requiring the support of somatic symptom (SS) felt about school during school closure. Further, using parents' and caregivers' answers, SS scores were calculated before and during school closure and after school reopening. RESULTS: The proportion of students with a high risk of developing psychosomatic disorder increased in all groups. For the students in Group P, the response "I did not want to think about school" indicated an increase in SS scores, and for the students in Group O, "I wanted to get back to school soon" indicated a decrease. Furthermore, especially in Group P students, SS scores decreased transiently during school closure and increased after school reopening. CONCLUSIONS: The impact of school closure on mental health differed depending on students' diagnoses and feelings about school during school closures.


Assuntos
COVID-19/epidemiologia , Saúde Mental/estatística & dados numéricos , Instituições Acadêmicas , COVID-19/prevenção & controle , Criança , Doença Crônica , Deficiências do Desenvolvimento/epidemiologia , Humanos , Japão/epidemiologia , Pandemias , Transtornos Psicofisiológicos/epidemiologia , Fatores de Risco , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...