Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Catheter Cardiovasc Interv ; 101(4): 764-772, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36786488

RESUMO

OBJECTIVES: This study aimed to determine whether drug-coated balloon (DCB) angioplasty following intraplaque wiring and the use of modified balloons is safe and effective in the percutaneous treatment of coronary chronic total occlusions (CTOs). BACKGROUND: DCB is an alternative therapeutic option without the limitations of permanent vascular implants. However, its efficacy in CTOs has yet to be confirmed. The combination of modified balloons and DCB can be effectively applied when the intraplaque passage of the guidewire is achieved in CTOs. METHODS: Data from 124 consecutive CTO lesions (105 patients) treated at our hospital between February 2016 and December 2020 were screened for inclusion and retrospectively analyzed. Among the 118 lesions successfully recanalized, intraplaque wiring was achieved in 108, and 85 were treated by the DCB-only approach following cutting/scoring balloon dilatation. RESULTS: Follow-up data were available for 82 lesions (71 patients). The median occlusion length was 18.5 mm, and the J-CTO score was 1.7 ± 0.9. No in-hospital major adverse cardiac events occurred, including abrupt vessel closure. During the median 29-month follow-up period, target lesion revascularization was performed for 10 lesions. Follow-up coronary angiography (8.7 ± 3.9 months after the index procedure) was performed for 64 lesions, demonstrating late lumen loss of -0.15 mm (interquartile range -0.4 to 0.23 mm), binary restenosis (diameter stenosis ≥50%) in 12 lesions (18.8%), and late lumen enlargement in 37 (57.8%). CONCLUSION: The DCB-only approach following the use of modified balloons is a promising strategy for coronary CTOs when intraplaque wiring is achieved.


Assuntos
Oclusão Coronária , Reestenose Coronária , Intervenção Coronária Percutânea , Humanos , Oclusão Coronária/terapia , Vasos Coronários , Estudos Retrospectivos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Angiografia Coronária , Materiais Revestidos Biocompatíveis , Reestenose Coronária/etiologia
2.
Catheter Cardiovasc Interv ; 99(6): 1758-1765, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35253349

RESUMO

OBJECTIVES: This study aimed to examine whether the combination of excimer laser coronary atherectomy (ELCA) and drug-coated balloon (DCB) angioplasty can provide feasible clinical outcome in patients with ST-segment elevation myocardial infarction (STEMI) with 8-month and 2-year scheduled follow-up angiography. BACKGROUND: Intracoronary thrombus elevates the risk of interventional treatment in patients with STEMI and hampers drug absorption into the vasculature released from DCB. METHODS: Sixty-two patients with STEMI within 24 h after the onset of symptoms were enrolled in this prospective, single-center, single-arm study. RESULTS: The laser catheter was successfully crossed distal to the culprit lesion in all cases. No ELCA-related adverse events occurred. Bail-out stenting was required in two patients (3.2%) after adjunctive ballooning; thus, the remaining 60 patients were completed with DCB angioplasty without stenting. Scheduled angiography at 8 months and 2 years was completed in 100% and 85.2%, respectively, and minimal lumen diameters were 3.4 ± 0.5, 3.4 ± 0.6, and 3.4 ± 0.5 mm after the procedure, at 8 months and at 2 years, respectively. Binary restenosis was observed in five patients (8.1%) in whom target lesion revascularization was performed. The duration of dual antiplatelet therapy was 2.3 ± 2.2 months, and neither abrupt vessel closure, reinfarction, cardiac death nor major bleeding was observed. CONCLUSION: A combination of DCB angioplasty with ELCA is a feasible therapeutic option for STEMI.


Assuntos
Stents Farmacológicos , Terapia a Laser , Infarto do Miocárdio com Supradesnível do Segmento ST , Angiografia Coronária , Humanos , Lasers , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Resultado do Tratamento
3.
J Interv Cardiol ; 2021: 5590109, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34393666

RESUMO

OBJECTIVES: We evaluated the thrombus-vaporizing effect of excimer laser coronary angioplasty (ELCA) in patients with ST-segment elevation myocardial infarction (STEMI) by optical coherence tomography (OCT). BACKGROUND: Larger intracoronary thrombus elevates the risk of interventional treatment and mortality in patients with STEMI. METHODS: A total of 92 patients with STEMI who presented within 24 hours from the onset and underwent ELCA following manual aspiration thrombectomy (MT) were analyzed. RESULTS: The mean baseline thrombolysis in myocardial infarction flow grade was 0.4 ± 0.6, which subsequently improved to 2.3 ± 0.7 after MT (p < 0.0001) and 2.7 ± 0.5 after ELCA (p=0.0001). The median residual thrombus volume after MT was 65.7 mm3, which significantly reduced to 47.5 mm3 after ELCA (p < 0.0001). Plaque rupture was identified by OCT in only 22 cases (23.9%) after MT, but was distinguishable in 36 additional cases after ELCA (total: 58 cases; 63.0%). Ruptured lesions contained a higher proportion of red thrombus than nonruptured lesions (75.9% vs. 43.3%, p=0.001). Significantly larger thrombus burden after MT (69.6 mm3 vs. 56.3 mm3, p < 0.05) and greater thrombus reduction by ELCA (21.2 mm3 vs. 11.8 mm3, p < 0.01) were observed in ruptured lesions than nonruptured lesions. CONCLUSIONS: ELCA effectively vaporized intracoronary thrombus in patients with STEMI even after MT. Lesions with plaque rupture contained larger thrombus burden that was frequently characterized by red thrombus and more effectively reduced by ELCA.


Assuntos
Trombose Coronária , Terapia a Laser , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Idoso , Angiografia Coronária , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Trombectomia , Tomografia de Coerência Óptica , Resultado do Tratamento
4.
Ann Vasc Surg ; 58: 91-100, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30769058

RESUMO

BACKGROUND: Chronic total occlusion (CTO) of femoropopliteal artery (FP) continues to be a lesion subset where maintaining long-term patency after endovascular treatment is challenging. We evaluated the efficacy of cutting balloon angioplasty (CBA) for de novo FP-CTOs in patients with symptomatic lower limb ischemia. METHODS: Seventy-three limbs of 67 symptomatic patients with de novo FP-CTOs successfully recanalized using CBA alone were enrolled in this study. Primary patency was defined as the absence of recurrent symptoms and no deterioration of the ankle-brachial index (ABI) >0.10 from the immediate postinterventional value. RESULTS: The mean age was 73.5 ± 7.3 years, and 59.7% of patients had diabetes mellitus. Most lesions were classified as Trans-Atlantic Inter-Society Consensus II type C (n = 18; 24.7%) or type D (n = 44; 60.3%), with mean lesion and occluded lengths of 24.8 ± 11.4 and 17.8 ± 11.2 cm, respectively. No procedure-related adverse events occurred, except one distal embolization. The ABI significantly increased after intervention from 0.52 ± 0.12 to 0.80 ± 0.15 (P < 0.0001), with marked improvement in clinical symptoms (Rutherford stage: 2.7 ± 1.0 to 1.1 ± 1.2, P < 0.0001). The mean follow-up period was 31.2 ± 18.0 months, and the primary patency rates at 12 and 24 months were 75.3% and 60.6%, respectively. The independent predictive factors of failed patency were baseline hemoglobin A1c (P = 0.031, hazard radio [HR] 1.51 per 1%), occluded length ≥15 cm (P = 0.036, HR 2.90), and severe dissection (P = 0.033, HR 2.85). Vessel calcification and diameter did not affect primary patency. CONCLUSIONS: CBA is a feasible option for endovascular treatment of FP-CTOs. Diabetic status, occlusion length, and severe dissection after CBA are independent negative predictors of long-term patency.


Assuntos
Angioplastia com Balão/métodos , Artéria Femoral/cirurgia , Doença Arterial Periférica/cirurgia , Artéria Poplítea/cirurgia , Idoso , Idoso de 80 Anos ou mais , Angiografia , Angioplastia com Balão/efeitos adversos , Índice Tornozelo-Braço , Doença Crônica , Constrição Patológica , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Masculino , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Grau de Desobstrução Vascular
6.
J Cardiol ; 70(6): 584-590, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28527865

RESUMO

BACKGROUND: Functional mitral regurgitation (MR) can occur in patients with atrial fibrillation (AF) despite having preserved left ventricular (LV) systolic function. This MR is known as atrial functional MR. The aim of this study was to clarify the mechanism of atrial functional MR using real-time three-dimensional transesophageal echocardiography (3DTEE). METHODS: Sixty patients underwent transthoracic echocardiography and 3DTEE: 16 patients with AF and significant non-organic MR and preserved LV ejection fraction (>50%) constituted the AF-MR group, 20 patients with AF and no significant MR formed the AF-NSMR group, and 24 normal subjects comprised the control group. RESULTS: The left atrial volume index was significantly larger in the AF-MR group (95±41ml/m2) than in the AF-NSMR group (38±13ml/m2, p<0.05) or the control group (21±7ml/m2, p<0.05). The 3D annular circumference was significantly longer in the AF-MR group than in the AF-NSMR group. The annular-anterior leaflet coaptation angle was smaller in the AF-MR group than in the AF-NSMR group (11±6° vs. 18±9°, p<0.05). The annular-posterior leaflet coaptation angle was comparable between the two AF groups (26±12° vs. 28±10°), whereas the annular-posterior leaflet tip angle was larger in the AF-MR group than in the AF-NSMR group (59±13° vs. 44±11°, p<0.05). The posterior leaflet bending toward LV cavity was therefore significantly larger in the AF-MR group than in the AF-NSMR group (32±10° vs. 18±15°, p<0.05). CONCLUSIONS: In patients with AF and significant functional MR occurring despite their preserved LV systolic function, the left atrium and mitral annulus were dilated and the anterior leaflet was flattened along the mitral annular plane, whereas the posterior leaflet was bent toward the LV cavity.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Dilatação Patológica , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/patologia , Valva Mitral/fisiopatologia , Função Ventricular Esquerda
7.
Cardiovasc Diagn Ther ; 6(2): 172-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27054107

RESUMO

We report two cases of severe aortic stenosis (AS) where antegrade balloon aortic valvuloplasty (BAV) was performed under real-time transesophageal echocardiography (TEE) guidance. Real-time TEE can provide useful information for evaluating the aortic valve response to valvuloplasty during the procedure. It was led with the intentional wire-bias technique in order to compress the severely calcified leaflet, and consequently allowed the balloon to reach the largest possible size and achieve full expansion of the aortic annulus.

8.
J Atr Fibrillation ; 8(2): 1293, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-27957194

RESUMO

PURPOSE: In this study, we examined the hypothesis that the preferential conduction property along left lateral ridge (LLR) might affect the arrhythmogenicity of left pulmonary veins (LPVs). METHODS: The study population included 40 consecutive AF patients. Radiofrequency energy (RF) was sequentially delivered along the LLR from a lower to upper manner during postero-lateral CS pacing during an isoproterenol infusion. RESULTS: The conduction time during pacing from the CS was significantly prolonged during radiofrequency (RF) deliveries (before vs. after, upper; 91±26ms vs. 127±38ms, p<0.001, lower; 86±21ms vs. 103±22ms, p<0.001). Remarkable prolongation of more than 30ms was observed in 19 of 40 patients (48%) (both LPVs, 6; only the upper LPVs, 12; and only the lower LPV, 1). Sites with a remarkable prolongation were observed at the carina between the LPVs,[4] anterior site of the upper LPV carina,[10] anterior wall of the lower LPV,[3] and bottom of the lower LPVs [2] Thirty-three arrhythmogenic foci (AMF) from the LPVs were observed in 23/40 patients (56%). The conduction time during pacing from the LPVs during the RF delivery was significantly longer in the patients with AMF from the upper LPV than in those patients without (107±36ms vs. 146±40ms, p<0.01). CONCLUSION: The LLR includes the preferential conduction properties between the CS and LPVs, and the observation of the serial changes during the RF delivery could provide us information about the LPVs arrhythmogenicity.

9.
Heart Rhythm ; 12(3): 470-476, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25433142

RESUMO

BACKGROUND: The features of intrinsic ganglionated plexi (GP) in both atria after extensive pulmonary vein isolation (PVI) and their clinical implications have not been clarified in patients with atrial fibrillation (AF). OBJECTIVE: The purpose of this study was to assess the features of GP response after extensive PVI and to evaluate the relationship between GP responses and subsequent AF episodes. METHODS: The study population consisted of 216 consecutive AF patients (104 persistent AF) who underwent an initial ablation. We searched for the GP sites in both atria after an extensive PVI. RESULTS: GP responses were determined in 186 of 216 patients (85.6%). In the left atrium, GP responses were observed around the right inferior GP in 116 of 216 patients (53.7%) and around the left inferior GP in 57 of 216 (26.4%). In the right atrium, GP responses were observed around the posteroseptal area: inside the CS in 64 of 216 patients (29.6%), at the CS ostium in 150 of 216 (69.4%), and in the lower right atrium in 45 of 216 (20.8%). The presence of a positive GP response was an independent risk factor for AF recurrence (hazard ratio 4.04, confidence interval 1.48-11.0) in patients with paroxysmal, but not persistent, AF. The incidence of recurrent atrial tachyarrhythmias in patients with paroxysmal AF with a positive GP response was 51% vs 8% in those without a GP response (P = .002). CONCLUSION: The presence of GP responses after extensive PVI was significantly associated with increased AF recurrence after ablation in patients with paroxysmal AF.


Assuntos
Fibrilação Atrial/cirurgia , Denervação Autônoma/métodos , Ablação por Cateter/métodos , Gânglios Autônomos/cirurgia , Átrios do Coração/inervação , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Feminino , Gânglios Autônomos/fisiopatologia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 84(3): 426-35, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-24497466

RESUMO

OBJECTIVES: To evaluate the feasibility and safety of a virtual 3-Fr system [5-Fr sheathless-guiding catheter (GC)] for percutaneous coronary intervention (PCI). BACKGROUND: The use of miniaturized devices for PCI is gaining popularity because of increased patient comfort and decreased risk of access site complications. METHODS: From July 2010 to December 2012, consecutive patients who underwent elective PCI (planned or ad hoc PCI) at our hospital were enrolled. PCI using the virtual 3-Fr system was attempted as our initial strategy, unless a 6-Fr or larger GC was considered to be suitable [lesions with heavy calcification, large (>2 mm) side branches, or chronic total occlusion]. RESULTS: Five hundred sixty-six patients underwent elective PCI during the study period, and 132 patients who met the criteria underwent PCI using the virtual 3-Fr system. Procedures using the virtual 3-Fr system were successful in 126 patients (95%); 111 (84%) were performed using the transradial approach, 110 (83%) were ad hoc procedures, and 45 (31%) were complex coronary lesions (type B2 or C). Six patients required conversion to a conventional 5- or 6-Fr sheath and catheter system. No intraoperative complications occurred, and radial artery patency was achieved in all patients who underwent transradial procedures. CONCLUSIONS: PCI using the virtual 3-Fr system is a feasible and viable alternative to conventional procedures that use a sheath and GC in appropriately selected patients. This small-caliber system may minimize endovascular trauma, particularly during transradial coronary procedures.


Assuntos
Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/instrumentação , Interface Usuário-Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Artéria Radial , Estudos Retrospectivos , Resultado do Tratamento
11.
J Invasive Cardiol ; 24(11): E283-8, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23117322

RESUMO

A large thrombus load on the culprit coronary artery of patients with acute myocardial infarction (MI) is associated with increased procedural complications and adverse coronary events following angioplasty. This case series describes effective removal of large, occlusive thrombi in acute MI via direct aspiration using a standard 6 Fr guide catheter, following failed conventional catheter aspiration. This procedure is a simple and rapid alternative for challenging thrombi-containing coronary lesions when current thrombectomy catheters fail.


Assuntos
Cateterismo Cardíaco/métodos , Cateteres Cardíacos , Trombose Coronária/complicações , Trombose Coronária/cirurgia , Infarto do Miocárdio/etiologia , Artéria Radial , Trombectomia/métodos , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/instrumentação , Angiografia Coronária , Trombose Coronária/diagnóstico por imagem , Eletrocardiografia , Desenho de Equipamento , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Sucção/instrumentação , Sucção/métodos , Trombectomia/instrumentação , Resultado do Tratamento
12.
J Endovasc Ther ; 19(5): 620-6, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23046327

RESUMO

PURPOSE: To describe a novel technique using an antegrade wire in a retrograde microcatheter advanced through a transcollateral vessel for recanalization of challenging infrapopliteal chronic total occlusions. TECHNIQUE: A 75-year-old diabetic man presented with critical limb ischemia manifested as nonhealing ulcers on the toes. Baseline angiography revealed a blunt, long, total occlusion of the anterior tibial artery. A retrograde microcatheter was advanced over a guidewire tracking the collateral channel from the planter artery. Antegrade and retrograde microcatheters were aligned inside the occluded lesion. An antegrade wire was then advanced further down through the retrograde microcatheter. Final angiography of the anterior tibial artery following balloon dilation demonstrated a satisfactory result, without evidence of significant residual stenoses or flow-limiting dissections. Complete wound healing was achieved at 3 weeks. CONCLUSION: This alternative wire method may be useful when traditional interventional approaches are unfeasible.


Assuntos
Angioplastia com Balão/métodos , Arteriopatias Oclusivas/terapia , Circulação Colateral , Isquemia/terapia , Artérias da Tíbia/fisiopatologia , Idoso , Angioplastia com Balão/instrumentação , Arteriopatias Oclusivas/complicações , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/fisiopatologia , Doença Crônica , Constrição Patológica , Pé Diabético/etiologia , Pé Diabético/fisiopatologia , Pé Diabético/terapia , Desenho de Equipamento , Humanos , Isquemia/etiologia , Isquemia/fisiopatologia , Masculino , Miniaturização , Radiografia , Fluxo Sanguíneo Regional , Artérias da Tíbia/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento , Dispositivos de Acesso Vascular , Cicatrização
13.
Circ J ; 72(1): 51-5, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18159099

RESUMO

BACKGROUND: Asymptomatic acute ischemic stroke (aAIS) following primary percutaneous coronary intervention (p-PCI) in patients with acute coronary syndrome (ACS) has not been studied in detail. METHODS AND RESULTS: Of 75 patients who underwent p-PCI, 26 (34.7%) developed aAIS as determined by diffusion-weighted magnetic resonance imaging (MRI). Including the approach to the coronary artery (via lower limb or right upper limb), 23 factors were compared between patients with (n=26) and without (n=49) aAIS. Age, hypertension, smoking, plasma glucose levels, Killip grade, right coronary artery (RCA) as culprit vessel, percutaneous coronary intervention (PCI) time, and the frequency of device insertion into the coronary artery differed in a statistically significant manner. However, multivariate analysis showed that the RCA (odds ratio 3.477) and the frequency of device insertion (1.375) were independent factors linked to the incidence of aAIS. Moreover, anterior or posterior location and left or right cerebral circulation of aAIS were equivalent in both approaches. CONCLUSIONS: Cranial MRI images following emergency PCI revealed that 34.7% of the patients with ACS had aAIS that might be caused by manipulating the catheter or devices in the ascending aorta, micro-air bubble embolism during injection, or micro-thrombus embolism derived from the ACS lesions during the PCI procedure.


Assuntos
Síndrome Coronariana Aguda/complicações , Angioplastia Coronária com Balão/efeitos adversos , Acidente Vascular Cerebral/etiologia , Síndrome Coronariana Aguda/terapia , Idoso , Estudos de Casos e Controles , Cateterismo/efeitos adversos , Vasos Coronários , Embolia Aérea/complicações , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Tromboembolia/complicações
15.
Hypertens Res ; 30(4): 349-57, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17541214

RESUMO

In this study, we investigated the effect of a specific chymase inhibitor, NK3201, in the progression of abdominal aortic aneurysm in a dog experimental model. Abdominal aortic aneurysms were induced in dogs by injecting elastase into the abdominal aorta. NK3201 (1 mg/kg per day, p.o.) or a placebo was started 3 days before elastase injection and continued for 8 weeks after the injection. On abdominal ultrasound, the aortic diameter was seen to gradually expand in the placebo-treated group, but not in the NK3201-treated group. Eight weeks after elastase injection, the ratio of the medial area to the total area in the placebo-treated group was significantly smaller than that in the normal group, but it was significantly larger than that in the NK3201-treated group. In addition to chymase activity, angiotensin II-forming and matrix metalloproteinase-9 activities were significantly higher in the placebo-treated group than in the normal group; in the NK3201-treated group, all of these activities were significantly decreased. On immunohistochemical analyses, there was a significantly greater number of chymase-positive cells in the placebo-treated group than in the normal group, but the number was significantly smaller in the NK3201-treated group than in the placebo-treated group. Thus, chymase inhibition may become a useful strategy for preventing abdominal aortic aneurysms.


Assuntos
Acetamidas/farmacologia , Aorta Abdominal/enzimologia , Aneurisma da Aorta Abdominal/etiologia , Aneurisma da Aorta Abdominal/fisiopatologia , Quimases/fisiologia , Pirimidinas/farmacologia , Angiotensina II/fisiologia , Animais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/efeitos dos fármacos , Aneurisma da Aorta Abdominal/prevenção & controle , Contagem de Células , Quimases/antagonistas & inibidores , Modelos Animais de Doenças , Progressão da Doença , Cães , Masculino , Metaloproteinase 9 da Matriz/fisiologia , Inibidores de Metaloproteinases de Matriz , Neutrófilos/efeitos dos fármacos , Neutrófilos/patologia , Túnica Média/efeitos dos fármacos , Túnica Média/patologia , Ultrassonografia
16.
Circ J ; 70(12): 1598-601, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17127806

RESUMO

BACKGROUND: Previous reports indicate that D-dimer testing (DT) for acute aortic dissection (AAD) has a sensitivity of 100%, but each study comprised less than 30 patients. The aim of this study was to evaluate the positive rate and factors related to the results of DT for AAD in a larger population. METHODS AND RESULTS: DT (cutoff; upper normal limit) was performed for 113 consecutive AAD patients within 24 h of symptom onset. In total, 104 (92%) patients exhibited positive DT. The positive rate of DT showed a low tendency in patients aged less than 70 years and for a time interval from symptom onset to admission within 120 min, and there were significant differences between those with and without a thrombosed false lumen (TFL) (86.4% (n=59) vs 98.1% (n=54), p=0.033), complete TFL (excluding patients with ulcer-like projection (ULP) from those with a TFL) (81.1% (n=37) vs 97.4% (n=76), p=0.005) and length score (1 (n=28); 78.6%, 2 (n=40); 95.0%, 3 (n=45); 97.8%, p=0.005). Multivariate analysis demonstrated age (odds ratio =1.164, p=0.013), complete TFL (0.048, 0.030) and length score (6.271, 0.033) as independent factors. CONCLUSIONS: Physicians should be aware that younger patients with short dissection length and a TFL without ULP are liable to have false-negative DT results.


Assuntos
Antifibrinolíticos , Aorta/patologia , Doenças da Aorta/diagnóstico , Produtos de Degradação da Fibrina e do Fibrinogênio , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Doenças da Aorta/patologia , Reações Falso-Negativas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
18.
Circ J ; 70(7): 827-31, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16799233

RESUMO

BACKGROUND: Public access defibrillation has been introduced to improve the outcome of patients experiencing out-of-hospital cardiac arrest (OHCA). The aim of this study was to examine the best location for automated external defibrillators (AED). METHODS AND RESULTS: All patients who were resuscitated after OHCA by emergency medical technicians in Takatsuki City over 6 years were enrolled. The annual incidence of OHCA and the number of 1-year survivors with good neurological outcome in each of 21 sub-location categories were investigated, as well as the ratio of ventricular fibrillation (VF) as the initial rhythm to the total OHCA in each of 5 location categories. In total, there were 1,112 patients with OHCA, 62 (5.6%) with VF and 14 (1.3%) with good neurological outcome. The annual incidence of cardiac arrest (CA) per site was the highest in railway stations (0.3000), followed by hospitals (0.1802), homes for the aged (0.1115), playgrounds (0.0769) and golf courses (0.0667). However, none of the patients experiencing CA at railway stations, homes for the aged and golf courses had a good neurological outcome. The ratio of VF to total CA was the highest in the workplace (35.3%). CONCLUSIONS: The 6 locations, including workplace, are recommended as appropriate locations for AED.


Assuntos
Área Programática de Saúde , Desfibriladores , Serviços Médicos de Emergência , Parada Cardíaca/terapia , Feminino , Hospitais , Humanos , Japão , Masculino , Estudos Retrospectivos
19.
Circ J ; 69(8): 958-61, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16041166

RESUMO

BACKGROUND: Patients with aortic dissection (AD) often demonstrate positive heart-type fatty acid-binding protein (H-FABP), but its significance is unclear. METHODS AND RESULTS: In 63 of 64 consecutive AD patients, the serum H-FABP concentration was measured and the H-FABP positive rate calculated (cutoff value: 6.2 ng/ml) for each of following factors: (1) with or without dissection of the ascending aorta; and (2) a thrombosed false lumen; (3) length score; (4) presence of shock; (5) malperfusion of limbs; (6) ST elevation and/or depression on electrocardiogram; and (7) renal dysfunction. In total 36 AD patients had a positive H-FABP test. Statistically significant differences in the H-FABP positive rate were observed between those with and without ascending AD (76.7% vs 39.4%, p = 0.003), and in the length score (p < 0.001). Multivariate logistic regression test demonstrated that the most significant factor was the length score (odds ratio: 2.239 (95% confidence interval: 1.119-4.481), p = 0.023). Moreover, a significant correlation was observed between length score and absolute H-FABP value (r = 0.420, p = 0.001). CONCLUSIONS: In patients with AD, an increased serum H-FABP concentration is caused by the protein being released not only from the cardiac muscle but also from skeletal muscle, or possibly the aortic wall. Physicians using H-FABP for detection of myocardial injury need to be aware that patients with a long or ascending AD will show an elevation of H-FABP.


Assuntos
Ruptura Aórtica/sangue , Proteínas de Transporte/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta/fisiopatologia , Ruptura Aórtica/patologia , Biomarcadores/sangue , Proteínas de Ligação a Ácido Graxo , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/fisiopatologia , Valor Preditivo dos Testes
20.
Circ J ; 69(6): 677-82, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15914945

RESUMO

BACKGROUND: It is important to rapidly distinguish patients with acute aortic dissection of the ascending aorta (AADa) from those with acute myocardial infarction (AMI), because minimizing the time to initiation of reperfusion therapy leads to maximum benefits for AMI and erroneous reperfusion therapy for AADa can produce harmful outcomes. The aim of this study was to find a simple test to distinguish such patients. METHODS AND RESULTS: Data were collected from 29 consecutive patients with AADa and 49 consecutive patients with AMI who were admitted within 4 h of the onset of symptoms. The D-dimer concentration and the ratio of the maximum upper mediastinal diameter to the maximum thoracic diameter on plain chest radiograph (M-ratio) in the emergency room were studied retrospectively. Setting the cutoff values of the D-dimer concentration and the M-ratio to 0.8 or 0.9 microg/ml and 0.309, respectively, gave a sensitivity of 93.1% and 93.1% for AADa, respectively, and a sensitivity of 91.8% and 85.7% for AMI, respectively. CONCLUSIONS: The D-dimer value and the M-ratio, with appropriate cutoff values, have potential as tests that can be routinely used to exclude AADa patients from patients diagnosed with AMI prior to reperfusion therapy.


Assuntos
Aneurisma da Aorta Torácica/sangue , Aneurisma da Aorta Torácica/diagnóstico por imagem , Dissecção Aórtica/sangue , Dissecção Aórtica/diagnóstico por imagem , Isquemia Miocárdica/sangue , Isquemia Miocárdica/diagnóstico por imagem , Idoso , Biomarcadores/análise , Serviços Médicos de Emergência , Feminino , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...