1.
CVIR Endovasc ; 7(1): 27, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38466503

RESUMO

BACKGROUND: Imipenem/cilastatin (IPM/CS) has long been administered intravenously as a carbapenem antibiotic. However, since this agent is poorly soluble in liquid, occasional reports have described its use as a short-acting, temporary embolic agent. The purpose of this study was to elucidate the characteristics of IPM/CS particles, which are thought to have pain-relieving effects against osteoarthritis-related pain, as an embolic agent. METHODS: Three aspects of IPM/CS as an embolic agent were evaluated in vitro: particle size; particle shape; and change in particle size over time. For particle size, the long diameter was measured. RESULTS: Mean particle size (n=244) was 29.2±12.0 µm (range, 1-60 µm). Shape (n=109) was round in 18.35%, elliptical in 11.93%, and polygonal in 69.72%, showing that most particles were polygonal. In observations of changes in particle size over time (n=9), particles had decreased to 75% of their original size at 82±10.7 min, 50% at 89.3±9.14 min, 25% at 91.3±8.74 min, complete dissolved at 91.8±9.02 min. A rapid shrinkage in diameter was seen in the final period. CONCLUSIONS: IPM/CS particles are ultrafine and the majority display a polygonal shape. This substance shows ultra-short embolic activity. This study revealed the characteristics of a substance that demonstrates an embolic effect not found in existing embolic materials.

2.
Gan To Kagaku Ryoho ; 50(4): 496-498, 2023 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-37066466

RESUMO

BACKGROUND: Generic oxaliplatin is widely used in colorectal cancer chemotherapy; however, studies on the adverse events of generic drugs are limited. We investigated the safety of brand-name and generic oxaliplatin used in capecitabine plus oxaliplatin(plus bevacizumab: Bmab)for colorectal cancer treatment. PARTICIPANTS AND METHODS: A total of 86 patients who newly started CAPOX(plus Bmab)between January 2018 and January 2022 were included in this retrospective study, excluding those who changed to generic from the brand-name drug during the chemotherapy course. RESULTS: Forty-seven patients(54.6%)were in the generic drug(GE)group, while 39 patients(45.4%)were in the brand drug(EP)group. No significant difference was observed in the patient characteristics between the GE and EP groups. The median number of oxaliplatin administrations were 4 and 5 cycles in the GE and EP groups, respectively. Neutropenia of Grade 2 or higher was observed in 51.1%(24 patients)and 33.3%(13 patients)in the GE and EP groups, respectively. Hypersensitivity was observed in 14.9%(7 patients)and 7.7%(3 patients)in the GE and EP groups, respectively. CONCLUSION: There were no statistically significant differences between generic and brand-name oxaliplatin in the frequency of adverse events.


Assuntos
Antineoplásicos , Neoplasias Colorretais , Oxaliplatina , Neoplasias Colorretais/tratamento farmacológico , Oxaliplatina/uso terapêutico , Antineoplásicos/uso terapêutico , Humanos , Capecitabina/uso terapêutico , Medicamentos Genéricos , Resultado do Tratamento , Estudos Retrospectivos
3.
Diagnostics (Basel) ; 13(4)2023 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-36832140

RESUMO

Catheterization of the right adrenal vein (rt.AdV) to obtain blood samples can often be difficult. The aim of the present study was to investigate whether blood sampling from the inferior vena cava (IVC) at its juncture with the rt.AdV can be an ancillary to sampling of blood directly from the rt.AdV. This study included 44 patients diagnosed with primary aldosteronism (PA) in whom AVS with adrenocorticotropic hormone (ACTH) was performed, resulting in a diagnosis of idiopathic hyperaldosteronism (IHA) (n = 24), and patients diagnosed with unilateral aldosterone-producing adenoma (APA) (n = 20; rt.APA = 8, lt.APA = 12). In addition to regular blood sampling, blood was also sampled from the IVC, as the substitute rt.AdV [S-rt.AdV]. Diagnostic performance with the conventional lateralized index (LI) and the modified LI using the S-rt.AdV were compared to examine the utility of the modified LI. The modified LI of the rt.APA (0.4 ± 0.4) was significantly lower than those of the IHA (1.4 ± 0.7) (p < 0.001) and the lt.APA (3.5 ± 2.0) (p < 0.001). The modified LI of the lt.APA was significantly higher than those of the IHA (p < 0.001) and rt.APA (p < 0.001). Likelihood ratios to diagnose rt.APA and lt.APA using the modified LI with threshold values of 0.3 and 3.1 were 27.0, and 18.6, respectively. The modified LI has the potential to be an ancillary method for rt.AdV sampling in cases in which rt.AdV sampling is difficult. Obtaining the modified LI is extremely simple, which might complement conventional AVS.

4.
J Neurosurg Case Lessons ; 4(5)2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-36088559

RESUMO

BACKGROUND: Aneurysmal subarachnoid hemorrhage (SAH) is one of the most severe neurosurgical diseases in which systemic management is important from the acute phase to the chronic phase. The authors reported a case of aneurysmal SAH associated with intra-abdominal hemorrhage possibly caused by segmental arterial mediolysis (SAM). OBSERVATIONS: A 60-year-old woman collapsed suddenly at home. On arrival at our hospital, she was comatose and her head computed tomography (CT) showed SAH, probably from an anterior cerebral artery aneurysm. Simultaneous body CT to screen for pneumonia associated with COVID-19 incidentally detected an intra-abdominal hematoma and the bleeding point. Emergent ventriculostomy was conducted first. Because abdominal angiography detected a ruptured pseudoaneurysm of an ovarian artery, emergency embolization was subsequently performed for hemostasis. However, she deteriorated again, and her pupils became fully dilated. The patient died on day 3 of hospitalization. LESSONS: Patients with aneurysmal SAH rarely have intra-abdominal hemorrhage in the acute stage and may have a fatal outcome. Intra-abdominal hemorrhage should be suspected in the setting of unstable vital signs, and prompt treatment is necessary.

5.
Br J Radiol ; 95(1131): 20210465, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34558293

RESUMO

OBJECTIVE: High b-value diffusion-weighted imaging (hDWI) with a b-value of 2000 s/mm2 provides insufficient image contrast between benign and malignant tissues and an overlap of apparent diffusion coefficient (ADC) between Gleason grades (GG) in prostate cancer (PC). We compared image quality, PC detectability, and discrimination ability for PC aggressiveness between ultra-high b-value DWI (uhDWI) of 3000 s/mm2 and hDWI. METHODS: The subjects were 49 patients with PC who underwent 3T multiparametric MRI. Single-shot echo-planar DWI was acquired with b-values of 0, 2000, and 3000 s/mm2. Anatomical distortion of prostate (AD), signal intensity of benign prostate (PSI), and lesion conspicuity score (LCS) were assessed using a 4-point scale; and signal-to-noise ratio, contrast-to-noise ratio, and mean ADC (×10-3 mm2/s) of lesion (lADC) and surrounding benign region (bADC) were measured. RESULTS: PSI was significantly lower in uhDWI than in hDWI (p < 0.001). AD, LCS, signal-to-noise ratio, and contrast-to-noise ratio were comparable between uhDWI and hDWI (all p > 0.05). In contrast, lADC was significantly lower than bADC in both uhDWI and hDWI (both p < 0.001). In comparison of lADC between tumors of ≤GG2 and those of ≥GG3, both uhDWI and hDWI showed significant difference (p = 0.007 and p = 0.021, respectively). AUC for separating tumors of ≤GG2 from those of ≥GG3 was 0.731 in hDWI and 0.699 in uhDWI (p = 0.161). CONCLUSION: uhDWI suppressed background signal better than hDWI, but did not contribute to increased diagnostic performance in PC. ADVANCES IN KNOWLEDGE: Compared with hDWI, uhDWI could not contribute to increased diagnostic performance in PC.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Imagem Ecoplanar , Humanos , Masculino , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética Multiparamétrica , Gradação de Tumores , Neoplasias da Próstata/patologia , Estudos Retrospectivos
6.
Magn Reson Imaging ; 83: 152-159, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34454006

RESUMO

PURPOSE: To compare diffusion-weighted imaging (DWI) and dynamic contrast-enhanced MR imaging (DCE-MRI) for characterization of prostate cancer (PC). METHODS: 104 PC patients who underwent prostate multiparametric MRI at 3T including DWI and DCE-MRI before MRI-guided biopsy or radical prostatectomy. Apparent diffusion coefficient (ADC) with histogram analysis (mean, 0-25th percentile, skewness, and kurtosis), intravoxel incoherent motion model including D and f; stretched exponential model including distributed diffusion coefficient (DDC) and a; and permeability parameters including Ktrans, Kep, and Ve were obtained from a region of interest placed on the dominant tumor of each patient. RESULTS: ADCmean, ADC0-25, D, DDC, and Ve were significantly lower and Kep was significantly higher in GS ≥ 3 + 4 tumors (n = 89) than in GS = 3 + 3 tumors (n = 15), and also in GS ≥ 4 + 3 tumors (n = 57) than in GS ≤ 3 + 4 tumors (n = 47) (P < 0.001 to P = 0.040). f was significantly lower in GS ≥ 4 + 3 tumors than in GS ≤ 3 + 4 tumors (P = 0.022), but there was no significant difference between GS = 3 + 3 tumors and GS ≥ 3 + 4 tumors, or between the remaining metrics in both comparisons. In metrics with area under the curve (AUC) >0.80, there was a significant difference in AUC between ADC0-25 and D, and DDC for separating GS ≤ 3 + 4 tumors from GS ≥ 4 + 3 tumors (P = 0.040 and P = 0.022, respectively). There were no significant differences between metrics with AUC > 0.80 for separating GS = 3 + 3 tumors from GS ≥ 3 + 4 tumors. ADC0-25 had the highest correlation with Gleason grade (ρ = -0.625, P < 0.001). CONCLUSIONS: DWI and DCE-MRI showed no apparent clinical superiority of non-Gaussian models or permeability MRI over the mono-exponential model for assessment of tumor aggressiveness in PC.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias da Próstata , Humanos , Imageamento por Ressonância Magnética , Masculino , Gradação de Tumores , Neoplasias da Próstata/diagnóstico por imagem , Estudos Retrospectivos
7.
Magn Reson Imaging ; 74: 213-222, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32858180

RESUMO

PURPOSE: To evaluate the influence of cholecystectomy on the flow dynamic pattern of bile in the extrahepatic bile duct by using cine-dynamic MRCP with spatially-selective inversion-recovery (IR) pulse non-invasively. MATERIALS AND METHODS: 56 patients with cholecystectomy and 48 control subjects without cholecystectomy who underwent cine-dynamic MRCP with spatially-selective IR pulse at 1.5 T or 3 T (TR/TE, 4000 msec/500 msec; echo train spacing, 6.5 msec; echo train length, 172; section thickness, 50 mm; matrix, 320 × 320; field of view, 320 × 320 mm; bandwidth, 488 Hz; and inversion time, 2200 msec). In cine-dynamic MRCP, IR pulse with 20 mm width was placed on the common bile duct (CBD) to evaluate the movement of bile (antegrade and reversed bile flow). Cine-dynamic MRCP imaging was scanned every 15 s (imaging, 4 s; rest, 11 s) during 5 min to acquire a series of single-shot images (a total of 20 images). The frequency that antegrade or reversed bile flow was observed in the extrahepatic bile duct, and 5-point grading score based on the moving distance of antegrade or reversed bile flow were compared between the groups. Both groups were compared using the χ2 and Mann-Whitney U tests (P < 0.05 considered significant). RESULTS: Antegrade bile flow was observed more frequently in the cholecystectomy group than in the non-cholecystectomy group (5.1 times vs. 2.8 times, P = 0.008). Mean grading score of antegrade bile flow was significantly greater in the cholecystectomy group than in the non-cholecystectomy group (mean grade, 0.33 vs 0.21; P = 0.014). Regarding reversed bile flow, there were no significant differences in the frequency and grading score between cholecystectomy group and non-cholecystectomy group. CONCLUSION: Antegrade bile flow was observed more frequently and predominantly in patients after cholecystectomy in cine-dynamic MRCP with spatially-selective IR pulse while reversed bile flow was observed equivalently.


Assuntos
Ductos Biliares Extra-Hepáticos/diagnóstico por imagem , Ductos Biliares Extra-Hepáticos/metabolismo , Bile/metabolismo , Colangiopancreatografia por Ressonância Magnética , Colecistectomia , Adulto , Idoso , Ductos Biliares Extra-Hepáticos/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade