Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
2.
Clin Orthop Surg ; 16(1): 23-33, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38304207

RESUMO

Background: While cementless short stems have become popular in total hip arthroplasty (THA), Metha is a relatively recent development that differs from other short stems in its initial fixation concept of partial collum-sparing metaphyseal anchorage. The purpose of this study was to quantify the contact state between Metha and the femur. Additionally, we investigated the difference in contact points between Meta and Fitmore, which is one of the more popular curved short stems. Methods: We conducted a retrospective review of 42 hips that underwent THA using Metha and 41 hips using Fitmore. Stem-to-femur contact was evaluated by density mapping using a three-dimensional digital template system to quantify the contact condition according to the modified Gruen zone. The criterion for the stem-to-bone contact boundary was defined as a computed tomography value of 543 Hounsfield. Results: Quantitative evaluation of Metha according to the modified Gruen zones showed the ratio of surface area with high cortical contact in each zone. The results were 4.6% ± 5.7% in zone 1, 0.9% ± 2.3% in zone 2, 19.1% ± 12.9% in zone 3, 1.4% ± 3.2% in zone 5, 29.6% ± 16.4% in zone 6, and 25.1% ± 17.7% in zones 7. Evaluation of Fitmore for the same zones was as follows: 1.6% ± 2.4%, 18.5% ± 16.9%, 20.8% ± 17.4%, 12.7% ± 12.8%, 3.7% ± 5.8%, and 13.3% ± 10.3%. Comparing the two groups, the contact area was significantly greater for Metha in zones 1, 6 and 7 and Fitmore in zones 2 and 5 (p < 0.05). Conclusions: It is possible for Metha to achieve metaphyseal anchoring by contacting the cortical bone at the proximal femur, thus avoiding proximal offloading. To the best of our knowledge, no previous studies have quantitatively reported stem-to-cortical bone contact conditions in curved short stems.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Tomografia Computadorizada por Raios X , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Software , Desenho de Prótese
3.
J Arthroplasty ; 38(11): 2386-2392, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37321519

RESUMO

BACKGROUND: Anterior quadratus lumborum block (AQLB) is one of the compartment blocks and has recently attracted attention as a new method of analgesia for postoperative hip surgery analgesia. This study aimed to compare the analgesic efficacy of AQLB in patients undergoing primary total hip arthroplasty (THA). METHODS: There were 120 patients undergoing primary THA under general anesthesia randomly allocated to receive a femoral nerve block (FNB) or an AQLB. The primary outcome was total morphine consumption over the initial 24-hour postoperative period. Secondary outcomes included the pain score evaluation while at rest and during active and passive motion over the 2 days following surgery and the manual muscle testing of the quadriceps femoris. The numerical rating scale (NRS) score was used for evaluating the postoperative pain score. RESULTS: There were no significant differences between the 2 groups concerning morphine consumption within 24 hours after surgery (P = .72). The NRS score at rest and passive motion were similar at all-time points (P > .05). However, there was a statistically significant difference in pain reported during the active motion for the FNB group compared to the AQLB (P = .04). No significant differences were found between the 2 groups concerning muscle weakness incidence. CONCLUSION: Both AQLB and FNB demonstrated adequate efficacy for postoperative analgesia at rest in THA. However, based on our study, whether AQLB is inferior or noninferior to FNB as an analgesic method for THA was inconclusive.


Assuntos
Artroplastia de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Analgésicos Opioides/uso terapêutico , Analgésicos , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Morfina/uso terapêutico , Anestésicos Locais
4.
Case Rep Orthop ; 2023: 8656265, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37292174

RESUMO

Background: Metal hypersensitivity is a rare complication after total hip arthroplasty (THA), and no reliable diagnostic method for metal hypersensitivity to orthopedic metal implants has yet been established. Case report. A 57-year-old woman underwent hemiarthroplasty using a metal implant despite a skin allergy to metal jewelry. Two years after surgery, the patient developed early hemiarthroplasty failure and refractory erythema. Although the patient was clinically suspected to have a hypersensitivity to metal, the preoperative screening test was negative, and patient underwent revision surgery with cemented THA. Postoperatively, the erythema as well as her hip pain disappeared completely. Conclusion: Patients with clinically suspected metal hypersensitivity should undergo primary and revision total hip arthroplasty using hypoallergenic implants regardless of preoperative screening results.

5.
Case Rep Orthop ; 2022: 3930806, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36106153

RESUMO

Case. A 20-year-old woman with severe subluxation of the hip displayed a leg length discrepancy of approximately 20 mm. The proposed treatment was a spherical periacetabular osteotomy (SPO) for joint preservation and postoperative leg length maintenance. SPO is a novel periacetabular osteotomy procedure. At her 3-year follow-up, the patient had functional, pain-free motion and high satisfaction. In this case, the SPO technique was able to achieve satisfactory clinical results without further exacerbating the leg length discrepancy after surgery.

6.
Arch Orthop Trauma Surg ; 142(12): 3987-3993, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34817670

RESUMO

PURPOSE: The purpose of the present study was to investigate the results of total hip arthroplasty (THA) using the Bicontact D stem with a minimum 10 year follow-up that focused on patients with developmental dysplasia of the hip (DDH). METHODS: One hundred five patients with osteoarthritis due to DDH who underwent primary THA were included in this study. The mean final follow-up period was 12.7 ± 1.2 years (range 10-15 years). All cases were evaluated both clinically and radiographically, and Kaplan-Meier survivorship was determined as stem revision for any reason as the end point. RESULTS: Modified Harris hip score averaged 89.0 ± 1.1 (range 60-98) at the final follow-up. The survivorship was 99.0% (95% confidence interval 93.4-99.9%) at 15.0 years, and only one hip with a well-fixed stem required stem revision due to recurrent dislocations. Cortical hypertrophy (CH) was observed in 40 of 105 hips (38.1%), and stress shielding (SS) progressed to grade 3 or 4 in six hips (6 of 105 hips: 5.7%) during the study period. Among the six hips with progressed SS, Dorr type C proximal femoral geometry was seen in five hips. CONCLUSION: This study of 105 THAs using the Bicontact D stem that focused on DDH patients with a minimum 10 year follow-up period achieved satisfactory clinical and radiological outcomes. Dorr type C proximal femoral geometry could be considered a risk factor for progressed SS.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteoartrite , Humanos , Seguimentos , Resultado do Tratamento , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Desenho de Prótese , Reoperação
7.
Case Rep Orthop ; 2021: 9970975, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34513103

RESUMO

BACKGROUND: Posttraumatic patellar dislocation is rare, and consistent surgical strategy therefore has not been defined due to multifactorial factor. In this case study, we treated a case of a patellar dislocation with hip osteoarthritis and increased femoral anteversion by performing a two-staged surgery. In the first stage, total hip arthroplasty was performed, and in the second stage, simultaneous patellofemoral arthroplasty and medial patellofemoral ligament reconstruction using semitendinosus tendon autograft were performed. Case Report. A 56-year-old female patient who previously had right hip osteoarthritis complained of right knee pain after a fall. Radiographic examination showed lateral dislocation of the patella with osteoarthritic (OA) change in the patellofemoral joint and an excessive femoral anteversion with OA change on the right hip joint. Total hip arthroplasty was performed firstly to decrease femoral anteversion. Then, simultaneous patellofemoral arthroplasty and medial patellofemoral ligament reconstruction was performed for residual patellar dislocation and patellofemoral OA without tibiofemoral joint OA. At the time of the 5-year follow-up after surgery, the patient was able to walk with a wheelbarrow without any complications. CONCLUSION: To the best of our knowledge, this is the first case of a patellar dislocation with an increased femoral anteversion and patellofemoral OA treated by a combination of total hip arthroplasty, patellofemoral arthroplasty, and medial patellofemoral ligament reconstruction. The clinical outcome improved at 5 years after these surgeries. Therefore, these surgical options can be considered to be useful.

8.
Arthroplast Today ; 11: 32-37, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34458531

RESUMO

An 84-year-old woman who underwent bilateral cementless total hip arthroplasty (THA) for dysplastic osteoarthritis 22 years ago was subjected to analysis. A huge soft-tissue mass was revealed in her left medial thigh. Plain radiographs of the left hip joint revealed severe osteolysis around the stem, cup, and ischium. Magnetic resonance imaging showed a 25 × 14-cm multilobulated mass with a thick-walled pseudocapsule. Two-stage surgery was performed with resection of the mass followed by a subsequent revision THA. The mass was diagnosed as a chronic expanding hematoma through gross and histologic findings. Two years after the revision THA, there was no recurrence of a hematoma. Two-stage revision THA was useful for definitive diagnosis, and good functional recovery was obtained after surgery.

9.
Case Rep Orthop ; 2021: 5560581, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34123448

RESUMO

BACKGROUND: Ballet dance involves extreme range of motion (ROM) in the hip joint. This ROM can cause injuries including labral strain, tears, and subluxation episodes. Case Presentation. A 69-year-old female classical ballet dance instructor presented bilateral hip pain. The plain radiograph showed end-stage osteoarthritic change in the bilateral hip. She could neither dance nor perform daily activities. Bilateral hybrid total hip arthroplasty (THA) was performed. After surgery, she was able to demonstrate the split position on the floor as an active classical ballerina. The plain radiograph was taken in the split position, and the radiograph did not show any characteristics of impingement or subluxation of the femoral head. CONCLUSION: She was able to continue working as a classical ballet instructor after bilateral THA. Additionally, any characteristics of impingement or subluxation of the femoral head were not revealed in the postoperative radiograph in the split position.

10.
Biochem Biophys Rep ; 25: 100898, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33490647

RESUMO

Circulating lymphocytes infiltrate into local foci at the inflammatory phase of acute wound healing for activation of the immune system and express an immune checkpoint protein programmed cell death 1 (PD-1) at the resolution phase for inactivation of the immune system. Conversely, the PD-1 expression was still found even on circulating lymphocytes of the elder patients with chronic tonsillitis at the palliative stage. Recently, an adhesion G protein coupled receptor 56 (GPR56) was reported to at least work as a proliferation factor for infiltrated lymphocytes into local foci at the resolution phase of acute wound healing. To preliminary examine a similar role of PD-1 and GPR56 at local foci at chronic inflammation, palate tonsils were prepared from small amounts of patients with chronic tonsillitis and tonsillar hypertrophy. A positive relationship of RNA expression might be observed between PD-1 and GPR56 in the elder patients with chronic tonsillitis. In regard to immunohistopathological findings, there were huge and small amounts of PD-1 and GPR56 expression at the marginal zone of lymphoid follicles of palate tonsils with chronic tonsillitis. Moreover, the positive relationship of RNA expression between PD-1 and GPR56 confirmed in large numbers of the elder patients with chronic tonsillitis. Probably, GPR56 participates in a supplement of PD-1+ lymphocytes to circulating bloods of the elder patients with chronic tonsillitis through a lymphocyte cell maintenance system at the marginal zone of the lymphoid follicles of palate tonsils.

11.
Arthroplast Today ; 6(4): 894-900, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33204784

RESUMO

BACKGROUND: Unloading of the proximal medial femoral cortex is usually associated with an increased bone strain at the distal part of the prosthesis, which may cause distal femoral cortical hypertrophy (CH). The objective of this study was to determine the factors that may be considered a predisposition to distal femoral CH and its effect on the stress shielding (SS) or durability of the fixation of the stem. METHODS: A total of 240 total hip arthroplasties were performed between January 2006 and December 2016, with all hips implanted with a Bicontact stem. The minimum follow-up period was more than 2 years, and the mean follow-up period was 7.2 years. The radiographic outcome was assessed on an anteroposterior hip radiograph. CH and SS were assessed on postoperative radiographs in the Gruen zone. We defined CH that appeared in zone 3 or 5 as 'the focal type' and defined CH that appeared in zones 2, 3, 4, 5, and 6 as 'the diffuse type.' SS followed the procedures from the Engh classification. RESULTS: CH was found in 72 hips (30% of the 240 hips), the focal type was found in 23 hips (9.6% of the 240 hips), and the diffuse type was found in 49 hips (20.4% of the 240 hips). SS was found in 41 hips (17.1% of 240 hips), including 32 hips with SS, which was found after the development of CH. One hip was from the focal-type CH and 31 hips were from the diffuse-type CH. SS, which is typically found in Engh classification types 1 and 2 developed in 13 hips, and SS, which is widely seen in Engh classification types 3 and 4 developed in 19 hips. All 19 hips with progressed SS were found after the diffuse-type CH had developed. In addition, among the 19 hips with progressed SS, Dorr type A was found in 0 hips, Dorr type B in 8 hips, and Dorr type C in 11 hips. CONCLUSIONS: According to the results of our radiological evaluation, development of the diffuse-type CH after total hip arthroplasty using Bicontact stems is one of the critical causes of the later development of SS and could be predicted to progress to SS. To prevent the development of the diffuse-type CH, the indication to choose a Bicontact stem for a Dorr type C with osteoporotic bone should be considered.

12.
Eur J Orthop Surg Traumatol ; 30(8): 1505-1514, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32638123

RESUMO

PURPOSE: Combined anteversion (CA) technique (stem-first procedure) has become generally accepted as an ideal means to achieve optimal CA value in THA. However, we hypothesized that CA technique for patients with various native femoral anteversions could pose a risk of anterior or posterior cup protrusion. In the present study, we examined whether it is possible to use the taper wedge stem to change the stem version to achieve optimal CA while avoiding cup protrusions with the cup-first procedure through minimally invasive (MIS) antero-lateral approach. METHODS: Eighty-one patients underwent cup-first THA with a taper wedge stem. The acetabular cup was placed following the preoperative planning of the cup alignment to avoid anterior cup protrusions using CT-based navigation. Following the CA theory, anteversion of the taper wedge stem was changed to the target anteversion from the patient's native femoral anteversion. The native femoral anteversion, the change in version angle of the stem, postoperative CA and the length of anterior cup protrusions were evaluated in postoperative CT measurements. RESULTS: The native femoral anteversion averaged 25.7° ± 8.9° (range 8°-45°). Cases with increased and decreased stem anteversion were observed in 42 hips (51.8%) and 33 hips (40.7%), respectively. The amount of increased and decreased version angles averaged 7.7° ± 4.8° (range 2°-21°) and 7.8° ± 5.1° (range 2°-20°), respectively. Postoperative CA values averaged 36.7° ± 3.4° (range 29.4°-44.2°) and anterior cup protrusion length averaged 2.0 mm ± 2.6 mm (0 ~ 8.8 mm) in axial view and 0.4 mm ± 1.0 mm (0 ~ 3.6 mm) in sagittal view. Anterior cup protrusion of more than 10 mm was not observed in any hips. CONCLUSION: This procedure can be considered as an option to achieve optimal CA anteversion while avoiding anterior cup protrusion in THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Desenho de Prótese
13.
Eur J Orthop Surg Traumatol ; 30(3): 465-472, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31705402

RESUMO

PURPOSE: Combined anteversion (CA) technique (stem-first procedure) is generally accepted as the optimal technique to attain an appropriate CA value in total hip arthroplasty (THA). However, cup anteversion is strongly influenced by the native femoral anteversion. Accordingly, anterior protrusion of the cup in the acetabulum might occur. The purpose of the present study is to investigate the achievement of the optimal CA while avoiding anterior cup protrusion and examine the significance of our new CA technique with cup-first procedure in hybrid THA. METHODS: Seventy-nine hybrid THAs with the cup-first procedure used a CT-based navigation system for cup positioning. In the preoperative planning, cup anteversion was aimed at approximately 20°. However, in actuality, sufficient cup coverage in the original acetabulum based on individual anatomy is given priority over cup placement based on CT-based planning to ensure adequate cup coverage. The target stem anteversion was determined following Widmer's mathematical formula (37.3 = femoral stem anteversion × 0.7 + cup anteversion). Cemented stem was inserted according to the target stem anteversion angle. RESULTS: Regarding the assessment of overall alignment, the calculated Widmer's CA values during surgery and postoperative CT evaluation were 34.1° ± 6.0° (range 20.7°-51.2°) and 35.1° ± 6.7° (range 21.6°-50.7°). There were 72 hips (91.1%) within 25°-50° of CA. Cup protrusion length averaged 2.0 mm ± 2.6 mm (0-8.8 mm) in the axial view and 0.4 mm ± 1.0 mm (0-3.6 mm) in the sagittal view. Cup protrusion length of more than 5 mm was indicated in 10 hips, and no hips observed more than 10 mm. CONCLUSION: Our new CA technique (cup-first procedure) with hybrid THA was able to achieve optimal CA value while avoiding anterior cup protrusion.


Assuntos
Artroplastia de Quadril/métodos , Radiografia Intervencionista , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X
14.
Medicine (Baltimore) ; 98(27): e16090, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31277106

RESUMO

Kerboull-type acetabular support rings (KT) and allogenic bone graft were used for severe periacetabular bone loss with primary and revision total hip arthroplasty (THA). The purpose of this case-control study is to evaluate the risk factors related to poor outcomes of surgery.Sixty patients underwent primary THA and revision THA using allogenic bone graft with KT for large acetabular deficiency. These patients were retrospectively evaluated postoperatively and followed-up by radiograph. The minimum follow-up period was 4 years and averaged 7 years. A radiological failure was defined by the following criteria:Expected risk factors were defined as female, age >75 years, body mass index (BMI) >25%, medical history of hypertension, renal failure, liver steatosis, diabetes, hyperlipidemia, cardiac infarction, smoking, American Academy of Orthopedic Surgery (AAOS) classification III or IV, bleeding>500 mL, time of surgery >3hours, high hip center-type KT, inclination of KT >45 degrees, screw angle >25 degrees, morselized bone graft, Kawanabe's classification stage 3 or 4 and revision surgery. Nineteen hips (31.6%) revealed radiological failure according to our criteria, and revision THA was performed in 2 hips (3.3%). In the statistical analysis, morselized bone graft and high hip center-type KT were identified as factors of poor outcomes of surgery.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Prótese de Quadril/efeitos adversos , Falha de Prótese/etiologia , Reoperação/instrumentação , Acetábulo/diagnóstico por imagem , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Transplante Ósseo/efeitos adversos , Estudos de Casos e Controles , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais
15.
Orthop Surg ; 11(3): 438-442, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31148364

RESUMO

OBJECTIVE: To evaluate the impact of spinopelvic parameters and hip contracture on change in the pelvic tilt (PT) after Total hip arthroplasty (THA). METHODS: One hundred patients (15 male and 85 female) who underwent THA were included in this prospective study. Radiographic data were obtained preoperatively and 1 year after THA. Radiographic parameters included sagittal anterior pelvic plane (APP), sagittal vertical axis (SVA), sacral slope (SS), pelvic inclination (PI), and lumbar lordosis angle (LL). The APP was defined as the angle between the anterior pelvic plane and the vertical plane. A positive value indicates pelvic retroversion. Postoperative changes in PT were divided into three groups: the PA group (pelvic anteversion, ΔAPP < -5°), the PR group (pelvic retroversion, ΔAPP > 5°), and the PT group (minimal change, ΔAPP ≤ ± 5°). The Kruskal-Wallis test and the Steel-Dwass test were used to compare the preoperative and postoperative spinopelvic parameters among the three groups. The Spearman's rank correlation coefficient was used to evaluate the correlation between ΔAPP and spinopelvic parameters. RESULTS: Minimal change in pelvic tilt was observed in 59% of patients, while pelvic anteversion was observed in 16% of patients and pelvic retroversion was observed in 25% of patients. There were no significant changes in the spinopelvic parameters, including TK, LL, SVA, LL, SS, and APP after THA. The Femoral angle (FA) was significantly decreased after THA (P < 0.001). Preoperative APP was significantly more retroverted in the PA group than the PR group, and the PT group (6.8 ± 12.2, 0.2 ± 9.9, -8.3 ± 8.3, P < 0.001). Preoperative SS, PI-LL, and PI were significantly smaller in the PA group than the PT group and the PR group. A significant negative correlation was identified between preoperative APP and ΔAPP (r = -0.418, P < 0.001). CONCLUSION: Approximately 60% of the patients did not have any marked change in PT after THA. Preoperative APP was the only predictive factor associated with marked anterior or posterior change in PT.


Assuntos
Artroplastia de Quadril , Mau Alinhamento Ósseo/etiologia , Vértebras Lombares/fisiopatologia , Pelve/fisiopatologia , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Mau Alinhamento Ósseo/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Lordose/diagnóstico por imagem , Lordose/etiologia , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Pelve/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Prospectivos , Radiografia
16.
J Arthroplasty ; 34(6): 1155-1161, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30898388

RESUMO

BACKGROUND: Postoperative pain is a significant concern of patients before surgery. Multimodal pain management is an effective method of pain control after major orthopedic surgery. Acetaminophen is the most commonly used analgesic for the management of pain. It was hypothesized that 1000 mg of intravenous acetaminophen (IA) dosed every 6 hours would significantly reduce the postoperative pain score at rest and the opioid consumption volume in patients who would undergo total hip arthroplasty (THA) when compared to a control group. METHODS: A single-center, prospective, open-label randomized control study was conducted. A total of 97 patients undergoing unilateral primary THA were divided into 2 groups: the study group (IA) (n = 45) and the control group (n = 52). The study group received administered IA after surgery, while the control group received only a standard pain control. Both groups received a preoperative femoral nerve block and postoperative intravenous fentanyl citrate. The primary outcome was the evaluation of the pain score at rest 24 hours after surgery. The pain score was measured using the Numerical Rating Scale. The primary outcome of this study was analyzed using generalized estimating equation. RESULTS: The IA group had a significant improvement in Numerical Rating Scale score at rest 24 hours after THA compared to the control group (-0.91, 95% confidence interval -1.56 to -0.26, P = .006), suggesting a positive effect of IA usage for pain relief. The total fentanyl citrate consumption after surgery for 24 hours was significantly lower in the IA group than those of the control group (52.07 ± 7.64 vs 57.83 ± 12.44 mg, P < .001). CONCLUSION: Postoperative administration of IA significantly reduced the postoperative pain score and opioid consumption volume after primary THA. IA was useful as one role of multimodal pain management after THA. LEVEL OF EVIDENCE: Level 2.


Assuntos
Acetaminofen/administração & dosagem , Analgesia/métodos , Analgésicos não Narcóticos/administração & dosagem , Artroplastia de Quadril/métodos , Manejo da Dor/métodos , Administração Intravenosa , Adulto , Idoso , Idoso de 80 Anos ou mais , Analgésicos Opioides/uso terapêutico , Feminino , Nervo Femoral/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória , Estudos Prospectivos
17.
Eur J Orthop Surg Traumatol ; 29(4): 807-812, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30656429

RESUMO

PURPOSE: In the combined anteversion (CA) technique for total hip arthroplasty (THA) with a cementless stem, cup anteversion is strongly influenced by the native femoral anteversion. It is hypothesized that in cases with large native femoral anteversion, cup anteversion can be decreased, and anterior cup protrusion from the anterior edge of the acetabulum could occur due to the achievement of optimal CA. In this study, the accuracy of CA in THA with the CA technique using imageless navigation and the relationship between the protrusion of the anterior edge of cup and optimum CA was retrospectively evaluated. METHODS: Ninety-seven patients (104 hips) who underwent primary THA by the CA technique using image-free navigation were enrolled in the study. The femoral stem was placed following the individual femoral anteversion so that the target cup anteversion could be determined following a mathematical formula (37 = femoral stem anteversion × 0.7 + cup anteversion). Results The resulting CA values effectively achieved accurate CA with 39.49 ± 5.03° postoperatively. On the other hand, anterior cup protrusion was measured by computed tomography image. A cup protrusion length of more than 3 mm was indicated for 60 cases (57.7%). All included patients were divided into two groups: Group 1 as protrusion positive and Group 2 as protrusion negative. In Group 1, preoperative femoral anteversion and postoperative stem anteversion were significantly higher, while postoperative cup anteversion was significantly lower. However, the postoperative CA value indicated no significant difference between the groups. CONCLUSIONS: The CA (stem-first) technique with image-free navigated THA could effectively achieve accurate CA. On the other hand, a large number of cases revealed anterior cup protrusion due to the low cup anteversion.


Assuntos
Artroplastia de Quadril/métodos , Cabeça do Fêmur/diagnóstico por imagem , Prótese de Quadril , Cirurgia Assistida por Computador/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Cabeça do Fêmur/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/cirurgia , Osteonecrose/diagnóstico por imagem , Osteonecrose/cirurgia , Complicações Pós-Operatórias , Ajuste de Prótese , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada Espiral , Adulto Jovem
18.
Case Rep Orthop ; 2019: 8654194, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31915559

RESUMO

A 64-year-old woman with a spontaneous fused hip sustained a left femoral neck fracture. It was revealed that her left hip joint had a long-standing spontaneous hip fusion due to end-stage osteoarthritis. Additionally, she sustained an ipsilateral femoral intertrochanteric fracture and underwent osteosynthesis using a dynamic hip screw 8 years ago. The one-stage THA was successfully treated with no major complications and good functional recovery was obtained. The hip range of motion improved remarkably at one year after surgery. The Modified Harris Hip Score improved from an estimated 70 points before fracture to 95 points at final follow-up.

19.
Eur J Orthop Surg Traumatol ; 29(3): 675-681, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30350020

RESUMO

PURPOSE: To investigate intraoperative kinematics during passive flexion using a surgical navigation system for knees undergoing posterior stabilized (PS) total knee arthroplasty (TKA) with an asymmetric helical post-cam design using navigation system. METHODS: In total, 45 knees with both pre- and postoperative kinematic data available were included in the study. Intraoperative kinematic measurements were performed during the course of surgery using the software incorporated in the navigation system. Measurements were performed at the following two time points: (1) before TKA procedure and (2) after TKA implantation. Among the kinematic parameters studied, anterior/posterior translation and axial rotation during flexion were subjected to the analysis. RESULTS: Before surgery, physiologic anterior/posterior translational pattern of the tibia during flexion (rollback of the femur) was found in only 15.6% of the knees. After TKA implantation, postoperative kinematic measurement showed no significant change in the tibial translational during knee flexion. Similarly, with regard to rotation, non-physiologic external tibial rotation in early flexion was observed in the majority of the knees before surgery, and this abnormal kinematic pattern remained after the TKA procedure. CONCLUSIONS: The intraoperative three-dimensional motion analysis using a navigation system showed that the physiologic kinematic pattern (anterior translation and internal rotation of the tibia during flexion) of the knee was distorted in osteoarthritic knees undergoing TKA. The abnormal kinematic pattern before surgery was not fully corrected even after implantation of the PS TKA designed to induce natural knee motion; however, no clear relationship between the intraoperative kinematic pattern and knee flexion angle at one year was demonstrated, and the effect of knee kinematics on postoperative knee function and patient's satisfaction is still unclear.


Assuntos
Artroplastia do Joelho/instrumentação , Articulação do Joelho/fisiopatologia , Prótese do Joelho , Osteoartrite do Joelho/fisiopatologia , Desenho de Prótese , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Rotação
20.
Medicine (Baltimore) ; 97(48): e13519, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30508981

RESUMO

RATIONALE: Curved periacetabular osteotomy (CPO) is a procedure with excellent surgical outcome that has been proposed for patients with development dysplasia of the hip (DDH). However, the surgical outcomes depend on the surgeon's experience and proficiency. PATIENT CONCERNS: A 38-year-old female indicated she was experiencing left hip pain while walking. DIAGNOSES: The patient was diagnosed with early-stage hip osteoarthritis due to DDH. INTERVENTIONS: The patient underwent CPO while a 3-dimensional flat-panel C-arm (Artis zeego; Sciemens Healthcare, Forchheim, Germany) was used to confirm the real-time 3-dimensional computed tomography (CT) images during surgery. It was possible to confirm the accurate osteotomy curve using CT images twice during surgery: at the time of the ischial osteotomy and the quadrilateral surface osteotomy. OUTCOMES: An ideal C-shaped osteotomy line was created as shown on the postoperative CT images. In addition, neither posterior column fracture nor intra-articular osteotomy was confirmed. LESSONS: The CPO using Artis zeego resulted is a satisfactory outcome, and this is the 1st report in the world to discuss the benefits of Artis zeego in pelvic osteotomy.


Assuntos
Imageamento Tridimensional/métodos , Osteoartrite do Quadril/cirurgia , Osteotomia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Tomografia Computadorizada por Raios X/métodos , Acetábulo/cirurgia , Adulto , Feminino , Luxação Congênita de Quadril/complicações , Humanos , Período Intraoperatório , Osteoartrite do Quadril/congênito
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...