Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nano Lett ; 19(1): 54-60, 2019 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-30241437

RESUMO

Point defects such as oxygen vacancies cause emergent phenomena such as resistive switching in transition-metal oxides, but their influence on the electron-transport properties is far from being understood. Here, we employ direct mapping of the electronic structure of a memristive device by spectromicroscopy. We find that oxygen vacancies result in in-gap states that we use as input for single-band transport simulations. Because the in-gap states are situated below the Fermi level, they do not contribute to the current directly but impact the shape of the conduction band. Accordingly, we can describe our devices with band-like transport and tunneling across the Schottky barrier at the interface.

2.
ACS Appl Mater Interfaces ; 10(35): 29766-29778, 2018 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-30088755

RESUMO

Redox-type resistive random access memories based on transition-metal oxides are studied as adjustable two-terminal devices for integrated network applications beyond von Neumann computing. The prevailing, so-called, counter-eight-wise (c8w) polarity of the switching hysteresis in filamentary-type valence change mechanism devices originates from a temperature- and field-controlled drift-diffusion process of mobile ions, predominantly oxygen vacancies in the switching oxide. Recently, a bipolar resistive switching (BRS) process with opposite polarity, so-called, eight-wise (8w) switching, has been reported that, especially for TiO2 cells, is still not completely understood. Here, we report on nanosized (<0.01 µm2) asymmetric memristive cells from 3 to 6 nm thick TiO2 films by atomic layer deposition, which reveal a coexistence of c8w and 8w switching in the same cell. As important characteristics for the studied Pt/TiO2/Ti/Pt devices, the resistance states of both modes are nonvolatile and share one common state; i.e., the high-resistance state of the c8w mode equals the low-resistance state of the 8w-mode. A transition between the opposite hysteresis loops is possible by voltage control. Specifically, 8w BRS in the TiO2 cells is a self-limited low-energy nonvolatile switching process. Additionally, the 8w reset process enables the programming of multilevel high-resistance states. Combining the experimental results with data from simulation studies allows to propose a model, which explains 8w BRS by an oxygen transfer process across the Pt/TiO2 Schottky interface at the position of the c8w filament. Therefore, the coexistence of c8w and 8w BRS in the nanoscale asymmetric Pt/TiO2/Ti/Pt cells is understood from a competition between drift/diffusion of oxygen vacancies in the oxide layer and an oxygen exchange reaction across the Pt/TiO2 interface.

3.
Magn Reson Med ; 79(5): 2752-2758, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28940621

RESUMO

PURPOSE: To characterize the diffusion coefficient of human blood for accurate results in intravoxel incoherent motion imaging. METHODS: Diffusion-weighted MRI of blood samples from 10 healthy volunteers was acquired with a single-shot echo-planar-imaging sequence at body temperature. Effects of gradient profile (monopolar or flow-compensated), diffusion time (40-100 ms), and echo time (60-200 ms) were investigated. RESULTS: Although measured apparent diffusion coefficients of blood were larger for flow-compensated than for monopolar gradients, no dependence of the apparent diffusion coefficient on the diffusion time was found. Large differences between individual samples were observed, with results ranging from 1.26 to 1.66 µm2 /ms for flow-compensated and 0.94 to 1.52 µm2 /ms for monopolar gradients. Statistical analysis indicates correlations of the flow-compensated apparent diffusion coefficient with hematocrit (P = 0.007) and hemoglobin (P = 0.017), but not with mean corpuscular volume (P = 0.64). Results of Monte-Carlo simulations support the experimental observations. CONCLUSIONS: Measured blood apparent diffusion coefficient values depend on hematocrit/hemoglobin concentration and applied gradient profile due to non-Gaussian diffusion. Because in vivo measurement is delicate, an estimation based on blood count results could be an alternative. For intravoxel incoherent motion modeling, the use of a blood self-diffusion constant Db = 1.54 ± 0.12 µm2 /ms for flow-compensated and Db = 1.30 ± 0.18 µm2 /ms for monopolar encoding is suggested. Magn Reson Med 79:2752-2758, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Assuntos
Sangue/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Difusão por Ressonância Magnética/métodos , Imagens de Fantasmas , Fenômenos Fisiológicos Sanguíneos , Difusão , Desenho de Equipamento , Feminino , Humanos , Masculino , Modelos Biológicos
4.
Phys Med Biol ; 62(16): 6486-6496, 2017 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-28632499

RESUMO

The detection of spherical markers in x-ray projections is an important task in a variety of applications, e.g. geometric calibration and detector distortion correction. Therein, the projection of the sphere center on the detector is of particular interest as the used spherical beads are no ideal point-like objects. Only few methods have been proposed to estimate this respective position on the detector with sufficient accuracy and surrogate positions, e.g. the center of gravity, are used, impairing the results of subsequent algorithms. We propose to estimate the projection of the sphere center on the detector using a simulation-based method matching an artificial projection to the actual measurement. The proposed algorithm intrinsically corrects for all polychromatic effects included in the measurement and absent in the simulation by a polynomial which is estimated simultaneously. Furthermore, neither the acquisition geometry nor any object properties besides the fact that the object is of spherical shape need to be known to find the center of the bead. It is shown by simulations that the algorithm estimates the center projection with an error of less than [Formula: see text] of the detector pixel size in case of realistic noise levels and that the method is robust to the sphere material, sphere size, and acquisition parameters. A comparison to three reference methods using simulations and measurements indicates that the proposed method is an order of magnitude more accurate compared to these algorithms. The proposed method is an accurate algorithm to estimate the center of spherical markers in CT projections in the presence of polychromatic effects and noise.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Radiografia/métodos , Calibragem , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...