Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Sci ; 32(6): 673-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27302589

RESUMO

A portable-type surface plasmon resonance (SPR) sensor, composed from a new optical system for multi-sensing, has been developed to apply to environment analysis, clinical diagnosis etc., where many samples are desired to be analyzed at high throughput. The optical system of the sensor consists of a light-emitting diode, a pair of cylindrical lenses, a pair of collimator lenses, a correction lens, a prism, a polarizer and a linear CCD sensor with 2048 pixels. Reflected light from a sensor chip of the width of 6 mm at a certain incident angle was detected by ca. 618 pixels of the linear CCD sensor as an SPR sensor signal. An SPR sensor signal at a specified incident angle is controllable for optimization by adjusting the position of the CCD sensor. A sensor chip having a 30-stripe linear pattern (100 µm width/stripe) was prepared. The spatial resolution as well as the performance of the sensor were evaluated by using sucrose solutions. As a result, the acquisition of SPR sensor signals from 30 sensing points was successfully achieved with a spatial resolution of 100 µm (distance between 2 sensing points). A lower detection limit of ca. 3.2 - 5.5 × 10(-5) RIU with a standard deviation of ±4.5% was obtained by averaging the signals from 6 - 7 pixels of the CCD sensor per one sensing stripe.

2.
Anal Chim Acta ; 576(1): 77-83, 2006 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-17723617

RESUMO

The use of a surface plasmon resonance immunosensor for the analysis of histamine (beta-imidazole ethylamine) is described. The method is based on an indirect competitive reaction of an anti-histamine antibody in a sample solution with histamine immobilized on a sensor chip and with histamine in the sample solution. A sensor chip immobilized with histamine was prepared using a self-assembly monolayer of 11-mercaptoundecanoic acid (11-MUA) as an anchor membrane, followed by an amino-coupling reaction with histamine after activation of the 11-MUA layer on the sensor chip by treatment with 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide and N-hydroxysuccinimide. The sensor chip can be reused, after regeneration with a 10mM HCl solution, which dissociates the anti-histamine antibody complex from histamine on the sensor chip. The affinity constants for the immunocomplex of the anti-histamine antibody with histamine in the solution and for that of the anti-histamine antibody with histamine immobilized on the sensor chip were calculated to be 1.5 x 10(7) and 7.2 x 10(5) M(-1), respectively, by assuming a Langmuir-type adsorption of the anti-histamine antibody to histamine immobilized on the sensor chip. The detection limit of the method was determined to be 3ppb.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...