Front Hum Neurosci ; 17: 1270605, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37771350

RESUMO

Introduction: Magnetoencephalography (MEG) can measure weak magnetic fields produced by electrical brain activity. Transcranial direct current stimulation (tDCS) can affect such brain activities. The concurrent application of both, however, is challenging because tDCS presents artifacts on the MEG signal. If brain activity during tDCS can be elucidated by MEG, mechanisms of plasticity-inducing and other effects of tDCS would be more comprehensively understood. We tested the technical feasibility of MEG during tDCS using a phantom that produces an artificial current dipole simulating focal brain activity. An earlier study investigated estimation of a single oscillating phantom dipole during tDCS, and we systematically tested multiple dipole locations with a different MEG device. Methods: A phantom provided by the manufacturer was used to produce current dipoles from 32 locations. For the 32 dipoles, MEG was recorded with and without tDCS. Temporally extended signal space separation (tSSS) was applied for artifact rejection. Current dipole sources were estimated as equivalent current dipoles (ECDs). The ECD modeling quality was assessed using localization error, amplitude error, and goodness of fit (GOF). The ECD modeling performance with and without tDCS, and with and without tSSS was assessed. Results: Mean localization errors of the 32 dipoles were 1.70 ± 0.72 mm (tDCS off, tSSS off, mean ± standard deviation), 6.13 ± 3.32 mm (tDCS on, tSSS off), 1.78 ± 0.83 mm (tDCS off, tSSS on), and 5.73 ± 1.60 mm (tDCS on, tSSS on). Mean GOF findings were, respectively, 92.3, 87.4, 97.5, and 96.7%. Modeling was affected by tDCS and restored by tSSS, but improvement of the localization error was marginal, even with tSSS. Also, the quality was dependent on the dipole location. Discussion: Concurrent tDCS-MEG recording is feasible, especially when tSSS is applied for artifact rejection and when the assumed location of the source of activity is favorable for modeling. More technical studies must be conducted to confirm its feasibility with different source modeling methods and stimulation protocols. Recovery of single-trial activity under tDCS warrants further research.

2.
IEEE Trans Med Imaging ; 41(6): 1400-1409, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34968176

RESUMO

Magnetic resonance electrical properties tomography (MREPT) noninvasively reconstructs high-resolution electrical property (EP) maps using MRI scanners and is useful for diagnosing cancerous tissues. However, conventional MREPT methods have limitations: sensitivity to noise in the numerical Laplacian operation, difficulty in reconstructing three-dimensional (3D) EPs and convergence not guaranteed in the iterative process. We propose a novel, iterative 3D reconstruction MREPT method without a numerical Laplacian operation. We derive an integral representation of the electric field using its Helmholtz decomposition with Maxwell's equations, under the assumption that the EPs are known on the boundary of the region of interest with the approximation that the unmeasurable magnetic field components are zero. Then, we solve the simultaneous equations composed of the integral representation and Ampere's law using a convex projection algorithm whose convergence is theoretically guaranteed. The efficacy of the proposed method was validated through numerical simulations and a phantom experiment. The results showed that this method is effective in reconstructing 3D EPs and is robust to noise. It was also shown that our proposed method with the unmeasurable component H- enhances the accuracy of the EPs in a background and that with all the components of the magnetic field reduces the artifacts at the center of the slices except when all the components of the electric field are close to zero.


Assuntos
Imageamento por Ressonância Magnética , Tomografia , Algoritmos , Artefatos , Condutividade Elétrica , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Tomografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...