1.
Sensors (Basel) ; 22(9)2022 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-35591198

RESUMO

This study was conducted with the aim of developing a circuit system that enables the measurement of the moisture content and ion concentration with a simple circuit configuration. Our previous studies have shown that soil can be represented by an equivalent circuit of a parallel circuit of resistors and capacitors. We designed a circuit that can convert the voltage transient characteristics of the soil when a current is applied to it into a square wave and output frequency information and developed an algorithm to analyze the two types of square waves and calculate R and C. Normal operation was confirmed in the range of 10 kΩ-1 MΩ for the designed circuit, and the calculation algorithm matched within a maximum error of 5%, thus confirming the validity of the program. These successfully confirmed the changes in the water content and ionic concentration. The soil moisture content measurement succeeded in measuring a maximum error of about 10%, except at one point, and the soil ion concentration measurement succeeded in measuring a maximum error of 6.6%. A new, simple, noise-resistant moisture content and ion concentration measurement circuit system with square wave output has been realized.


Assuntos
Solo , Água , Impedância Elétrica , Água/análise
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 2374-2377, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28268802

RESUMO

It is well known that an earlobe crease (ELC) is related with cardiovascular disease. However evaluation of ELC has been carried out subjectively. We propose a novel system for objective and quantitative evaluation of ELC characteristics. The outline of earlobe was detected using the Canny edge detector. The number of ELCs and the ratio of the ELC length for the lobule from photographs of bilateral earlobes were calculated from the extracted outline of earlobes. Our system's validity for ELCs detection was compared with doctors' diagnosis using sensitivity and specificity analysis. The result showed that the validity of our system was equal to the diagnosis of the medical doctors (kappa coefficient: 0.93). It was thus concluded that the proposed system is useful to predict atherosclerotic disease.


Assuntos
Arteriosclerose/diagnóstico , Orelha Externa , Processamento de Imagem Assistida por Computador , Doenças Cardiovasculares , Humanos , Fatores de Risco , Sensibilidade e Especificidade
3.
Sensors (Basel) ; 12(6): 8338-54, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22969403

RESUMO

Making several simultaneous measurements with different kinds of sensors at the same location in a solution is difficult because of crosstalk between the sensors. In addition, because the conditions at different locations in plant beds differ, in situ measurements in agriculture need to be done in small localized areas. We have fabricated a multimodal sensor on a small Si chip in which a pH sensor was integrated with electrical conductivity (EC) and temperature sensors. An ISFET with a Si(3)N(4) membrane was used for the pH sensor. For the EC sensor, the electrical conductivity between platinum electrodes was measured, and the temperature sensor was a p-n junction diode. These are some of the most important measurements required for controlling the conditions in plant beds. The multimodal sensor can be inserted into a plant bed for in situ monitoring. To confirm the absence of crosstalk between the sensors, we made simultaneous measurements of pH, EC, and temperature of a pH buffer solution in a plant bed. When the solution was diluted with hot or cold water, the real time measurements showed changes to the EC and temperature, but no change in pH. We also demonstrated that our sensor was capable of simultaneous in situ measurements in rock wool without being affected by crosstalk.


Assuntos
Agricultura/instrumentação , Técnicas Biossensoriais/instrumentação , Condutividade Elétrica , Miniaturização/instrumentação , Temperatura , Soluções Tampão , Sedimentos Geológicos , Concentração de Íons de Hidrogênio , Solanum lycopersicum/crescimento & desenvolvimento , Processamento de Sinais Assistido por Computador , Soluções
SELEÇÃO DE REFERÊNCIAS