Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 44(8): 3932-3938, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28513855

RESUMO

PURPOSE: The protective effects of induced or even accidental hypothermia on the human body are widespread with several medical uses currently under active research. In vitro experiments using human cell lines have shown hypothermia provides a radioprotective effect that becomes more pronounced at large, single-fraction doses common to stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS) treatments. This work describes the development of a system to evaluate local hypothermia for a radioprotective effect of the rat rectum during a large dose of radiation relevant to prostate SBRT. This includes the evaluation of a 3D-printed small animal rectal cooling device and the integration with a small animal irradiator. METHODS: A 3-cm long, dual-lumen rectal temperature control apparatus (RTCA) was designed in SOLIDWORKS CAD for 3D printing. The RTCA was capable of recirculating flow in a device small enough for insertion into the rat rectum, with a metal support rod for strength as well as visibility during radiation treatment planning. The outer walls of the RTCA comprised of thin heat shrink plastic, achieving efficient heat transfer into adjacent tissues. Following leak-proof testing, fiber optic temperature probes were used to evaluate the temperature over time when placed adjacent to the cooling device within the rat rectum. MRI thermometry characterized the relative temperature distribution in concentric ROIs surrounding the probe. Integration with an image-guided small animal irradiator and associated treatment planning system included evaluation for imaging artifacts and effect of brass tubing on dose calculation. RESULTS: The rectal temperature adjacent to the cooling device decreased from body temperature to 15°C within 10-20 min from device insertion and was maintained at 15 ± 3°C during active cooling for the evaluated time of one hour. MR thermometry revealed a steep temperature gradient with increasing distance from the cooling device with the desired temperature range maintained within the surrounding few millimeters. CONCLUSIONS: A 3D-printed rectal cooling device was fabricated for the purpose of inducing local hypothermia in the rat rectum. The RTCA was simply integrated with an image-guided small animal irradiator and Monte Carlo-based treatment planning system to facilitate an in vivo investigation of the radioprotective effect of hypothermia for late rectal toxicity following a single large dose of radiation.


Assuntos
Hipotermia Induzida , Lesões por Radiação/prevenção & controle , Reto/efeitos da radiação , Animais , Temperatura Corporal , Modelos Animais de Doenças , Humanos , Hipotermia , Masculino , Ratos
2.
Invest Radiol ; 52(9): 507-513, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28379863

RESUMO

OBJECTIVES: The aim of this study was to compare the anatomical registration of preoperative magnetic resonance imaging (MRI) and prostate whole-mount obtained with 3D-printed, patient-specific, MRI-derived molds (PSM) versus conventional whole-mount sectioning (WMS). MATERIALS AND METHODS: Based on an a priori power analysis, this institutional review board-approved study prospectively included 50 consecutive men who underwent 3 T multiparametric prostate MRI followed by radical prostatectomy. Two blinded and independent readers (R1 and R2) outlined the contours of the prostate, tumor, peripheral, and transition zones in the MRI scans using regions of interest. These were compared with the corresponding regions of interest from the whole-mounted histopathology, the reference standard, using PSM whole-mount results obtained in the study group (n = 25) or conventional WMS in the control group (n = 25). The spatial overlap across the MRI and histology data sets was calculated using the Dice similarity coefficient (DSC) for the prostate overall (DSCprostate), tumor (DSCtumor), peripheral (DSCPZ), and transition (DSCTZ) zone. Results in the study and control groups were compared using Wilcoxon rank sum test. RESULTS: The MRI histopathology anatomical registration for the prostate gland overall, tumor, peripheral, and transition zones were significantly superior with the use of PSMs (DSCs for R1: 0.95, 0.86, 0.84, and 0.89; for R2: 0.93, 0.75, 0.78, and 0.85, respectively) than with the use of standard WMS (R1: 0.85, 0.46, 0.66, and 0.69; R2: 0.85, 0.46, 0.66, and 0.69) (P < 0.0001). CONCLUSIONS: The use of PSMs for prostate specimen whole-mount sectioning provides significantly superior anatomical registration of in vivo multiparametric MRI and ex vivo prostate whole-mounts than conventional WMS.


Assuntos
Imageamento por Ressonância Magnética/métodos , Modelos Anatômicos , Impressão Tridimensional , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios/métodos , Estudos Prospectivos , Próstata/diagnóstico por imagem , Próstata/patologia , Prostatectomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...