Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Laryngol Otol ; 135(3): 196-205, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33666152

RESUMO

OBJECTIVE: Chronic rhinosinusitis patients with biofilms cultured from their sinonasal cavity have greater symptom burden and risk of recalcitrant disease. A number of non-antibiotic, 'anti-biofilm' treatments exist which show anti-biofilm properties in preclinical studies. There is little evidence evaluating their impact on clinical symptom scores in chronic rhinosinusitis. METHOD: A systematic review was performed to assess the literature regarding the efficacy of non-steroid, non-antibiotic, anti-biofilm specific topical therapies in the treatment of chronic rhinosinusitis. The primary outcome assessed was change in validated patient reported outcome measures before and after anti-biofilm treatment. RESULTS: Thirteen studies assessing the effect of anti-biofilm therapies in chronic rhinosinusitis through validated patient-reported outcome measures were included. Seven different anti-biofilm specific therapies for chronic rhinosinusitis were identified. None of the seven anti-biofilm therapies was identified as being confidently efficacious beyond placebo. Only one therapy (intranasal xylitol) showed a statistically significant reduction in symptom scores compared with placebo in more than one trial. CONCLUSION: Robust evidence supporting the use of various anti-biofilm therapies in chronic rhinosinusitis is lacking. Further high quality, human, in vivo trials studying the effect of anti-biofilm therapies in chronic rhinosinusitis are needed to address the deficiencies of the current evidence base.


Assuntos
Anti-Infecciosos Locais/uso terapêutico , Biofilmes/efeitos dos fármacos , Rinite/tratamento farmacológico , Sinusite/tratamento farmacológico , Administração Tópica , Adulto , Doença Crônica , Ensaios Clínicos como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cavidade Nasal/microbiologia , Medidas de Resultados Relatados pelo Paciente , Rinite/microbiologia , Sinusite/microbiologia , Resultado do Tratamento
2.
J Laryngol Otol ; 134(6): 558-561, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32618525

RESUMO

BACKGROUND: Pyriform aperture stenosis is a rare form of congenital nasal obstruction; it poses a management dilemma for otolaryngologists and physicians alike. It can result in poor weight gain and potentially life-threatening airflow obstruction. The challenge lies in the difficulty to predict which patients will require invasive operative management versus conservative therapy alone. CASE REPORT: This case demonstrates the successful use of high-flow nasal cannula therapy in a young child with pyriform aperture stenosis.


Assuntos
Cânula/efeitos adversos , Constrição Patológica/terapia , Obstrução Nasal/congênito , Doenças Nasais/congênito , Assistência ao Convalescente , Cânula/estatística & dados numéricos , Criança , Tratamento Conservador/métodos , Constrição Patológica/etiologia , Humanos , Masculino , Obstrução Nasal/diagnóstico por imagem , Obstrução Nasal/patologia , Doenças Nasais/complicações , Doenças Nasais/patologia , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
3.
Rev Sci Instrum ; 89(5): 056105, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29864798

RESUMO

A neutron polarizer using four successive reflections on m = 2.5 supermirrors was built and installed at the GINA neutron reflectometer at the Budapest Neutron Centre. This simple setup exhibits 99.6% polarizing efficiency with 80% transmitted intensity of the selected polarization state. Due to the geometry, the higher harmonics in the incident beam are filtered out, while the optical axis of the beam remains intact for easy mounting and dismounting the device in an existing experimental setup.

4.
Rev Sci Instrum ; 84(1): 015112, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23387700

RESUMO

The setup, capabilities, and operation parameters of the neutron reflectometer GINA, the recently installed "Grazing Incidence Neutron Apparatus" at the Budapest Neutron Centre, are introduced. GINA, a dance-floor-type, constant-energy, angle-dispersive reflectometer is equipped with a 2D position-sensitive detector to study specular and off-specular scattering. Wavelength options between 3.2 and 5.7 Å are available for unpolarized and polarized neutrons. Spin polarization and analysis are achieved by magnetized transmission supermirrors and radio-frequency adiabatic spin flippers. As a result of vertical focusing by a five-element pyrolytic graphite monochromator, the reflected intensity from a 20 × 20 mm(2) sample has been doubled. GINA is dedicated to studies of magnetic films and heterostructures, but unpolarized options for non-magnetic films, membranes, and other surfaces are also provided. Shortly after its startup, reflectivity values as low as 3 × 10(-5) have been measured by the instrument. The instrument capabilities are demonstrated by a non-polarized and a polarized reflectivity experiment on a Si wafer and on a magnetic film of [(62)Ni/(nat)Ni](5) isotope-periodic layer composition. The facility is now open for the international user community. Its further development is underway establishing new sample environment options and spin analysis of off-specularly scattered radiation as well as further decreasing the background.

5.
Rev Sci Instrum ; 83(8): 081301, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22938267

RESUMO

This review presents the implementation and full characterization of the polarization equipment of the time-of-flight neutron reflectometer PLATYPUS at the Australian Nuclear Science and Technology Organisation (ANSTO). The functionality and efficiency of individual components are evaluated and found to maintain a high neutron beam polarization with a maximum of 99.3% through polarizing Fe/Si supermirrors. Neutron spin-flippers with efficiencies of 99.7% give full control over the incident and scattered neutron spin direction over the whole wavelength spectrum available in the instrument. The first scientific experiments illustrate data correction mechanisms for finite polarizations and reveal an extraordinarily high reproducibility for measuring magnetic thin film samples. The setup is now fully commissioned and available for users through the neutron beam proposal system of the Bragg Institute at ANSTO.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...